OMNIREL OM1912NMM, OM1905NMM, OM1915NMM Datasheet

3.5 - 53
3.5
Three Terminal, Fixed Voltage, 1.5 Amp Precision Negative Regulators In Hermetic Surface Mount Package
4 11 R0
HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWINGS
FEATURES
• Hermetic Surface Mount Package
• Output Voltages: -5V, -12V, -15V
• Output Voltages Set Internally To ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Product Is Available Hi-Rel Screened
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed surface mount package. All protective features are designed into the circuit including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, and
-15V. These units are ideally suited for Military applications where a hermetic surface mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8874601 NX OM1905NMM 5962-8874701 NX OM1912NMM 5962-8874801 NX OM1915NMM
OM1915NMMOM1905NMM
OM1912NMM
3.5 - 54
OM1905NMM - OM1915NMM
3.5
ELECTRICAL CHARACTERISTICS -5 Volt V
IN
= -10V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -4.95 -5.05 V
V
IN
= -7.5V to -20V -4.85 -5.15 V
I
O
= 5mA to 1.0 A, P < 15W
Line Regulation V
RLINE
VIN= -7.5V to -20V 12 mV
(Note 1)
25mV
(Note 4) V
IN
= -8.0V to -12V 5 mV
12 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 20 mV
(Note 1)
25mV
I
O
= 250mA to 750 mA 15 mV
30 mV
Standby Current Drain I
SCD
2.5 mA
3.0 mA
Standby Current Drain ∆I
SCD
VIN= -7.0V to -20V 0.4 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA 0.4 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= -35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 63 dB
V
OUT
(Note 3) 60 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W aa
θJA.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
3.5 - 55
OM1905NMM - OM1915NMM
3.5
ELECTRICAL CHARACTERISTICS -12 Volt V
IN
= -19V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -11.88 -12.12 V
V
IN
= -14.5V to -27V -11.64 -12.36 V
I
O
= 5mA to 1.0 A, P < 15W
Line Regulation V
RLINE
VIN= -14.5V to -27V 20 mV
(Note 1)
50 mV
(Note 4) V
IN
= -16V to -22V 10 mV
30 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 32 mV
(Note 1)
60 mV
I
O
= 250mA to 750 mA 16 mV
30 mV
Standby Current Drain I
SCD
3.5 mA
4.0 mA
Standby Current Drain ∆I
SCD
VIN= -14.5V to -27V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=1.0A 1.8 V
Peak Output Current I
O (pk)
TA= 25°C, IO= 5mA to 1A 1.5 3.3 A
Short Circuit Current I
DS
V
IN
= -35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 56 dB
V
OUT
(Note 3) 53 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 120 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5 mA.
CONNECTION DIAGRAM
Pin 1 Ground Pin 2 Output Pin 3 Input
.140
.415
.157
.015
.140
.140
.075
.075
.062
.375
.030 MIN.
MECHANICAL OUTLINE
3
1
2
OM1905NMM - OM1915NMM
3.5
ELECTRICAL CHARACTERISTICS -15 Volt V
IN
= -23V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -14.85 -15.15 V
V
IN
= -17.5V to -30V -14.55 -15.45 V
I
O
= 5mA to 1.0 A, P < 15W
Line Regulation V
RLINE
VIN= -17.5V to -30V 25 mV
(Note 1)
50 mV
(Note 4) V
IN
= -20V to -26V 15 mV
25mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 35 mV
(Note 1)
75 mV
I
O
= 250mA to 750 mA 21 mV
45 mV
Standby Current Drain I
SCD
6.0 mA
6.5 mA
Standby Current Drain ∆I
SCD
VIN= -17.5V to -30V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000 mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= -35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 53 dB
V
OUT
(Note 3) 50 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 150 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
3.5
3
2.5
2
1.5
1
0.5
0 5 10 15 20 25 30 35
PEAK OUTPUT
V
OUT
= 100mV
Tj= -55°C
Tj= 25°C
Tj= 150°C
Input To Output Differential (V)
2.5
2
1.5
1
0.5
0
-75-50 -25 0 2 5 5 0 7 5 10 0 1 2 51 50
DROPOUT VOLTAGE
V
OUT
= 100MV
I
OUT
= 0A
I
OUT
= 500mA
I
OUT
= 1A
Junction Temperature (°C)
100
80
60
40
20
0
10 100 1k 10k
RIPPLE REJECTION
V
OUT
= 5V
V
IN
- V = 8V
DC
+3.5V
rms
I
OUT
= 1A
Tj= 25°C
Frequency (Hz)
TYPICAL PERFORMANCE CHARACTERISTICS
Output Current (A)
Output Current (A)
Ripple Rejection (dB)
Loading...