OMNIREL OM1915N2M, OM1905N2M, OM1912N2M Datasheet

3.5 - 49
3.5
LCC 20, Fixed Voltage, Precision Negative Regulators In Hermetic Surface Mount Package
4 11 R0
HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWING
FEATURES
• Hermetic Surface Mount Package
• Output Voltages: -5V, -12V, -15V
• Output Voltages Set Internally To ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Product Is Available Hi-Rel Screened
DESCRIPTION
These negative regulators are supplied in a hermetically sealed surface mount package. All protective features are designed into the circuit including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over .5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, and -15V. These units are ideally suited for Military applications where a hermetic surface mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8874601 2X OM1905N2M 5962-8874701 2X OM1912N2M 5962-8874801 2X OM1915N2M
OM1915N2MOM1905N2M
OM1912N2M
3.5 - 50
OM1905N2M - OM1915N2M
3.5
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2W
TA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1040 mW
Thermal Resistance θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25°C/W
θJA.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
ELECTRICAL CHARACTERISTICS -5 Volt V
IN
= -10V, Io= 100mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -4.95 -5.05 V
V
IN
= -7.5V to -20V -4.85 -5.15 V
I
O
= 5 mA to 500 mA, P < 2W
Line Regulation V
RLINE
VIN= -7.5V to -20V 12 mV
(Note 1)
25 mV
(Note 4) V
IN
= -8.0V to -12V 5 mV
12 mV
Load Regulation V
RLOAD
IO = 5mA to 500 mA 25 mV
(Note 1)
50 mV
Standby Current Drain I
SCD
2.5 mA
3.0 mA
Standby Current Drain ∆I
SCD
VIN= -7.0V to -20V 0.4 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 500 mA 0.4 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=500 mA 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 0.5 1.7 A
Short Circuit Current I
DS
VIN= -35V .7 A
(Note 2)
2.0 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 63 dB
V
OUT
(Note 3) 60 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5 - 51
OM1905N2M - OM1915N2M
3.5
ELECTRICAL CHARACTERISTICS -12 Volt V
IN
= -19V, Io= 100 mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -11.88 -12.12 V
V
IN
= -14.5V to -27V -11.64 -12.36 V
I
O
= 5mA to 500 mA, PD< 2 W
Line Regulation V
RLINE
VIN= -14.5V to -27V 20 mV
(Note 1)
50 mV
(Note 4) V
IN
= -16V to -22V 10 mV
30 mV
Load Regulation V
RLOAD
IO = 5 mA to 500 mA 32 mV
(Note 1)
60 mV
Standby Current Drain I
SCD
3.5 mA
4.0 mA
Standby Current Drain ∆I
SCD
VIN= -14.5V to -27V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 500 mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=500 mA 1.8 V
Peak Output Current I
O (pk)
TA= 25°C, IO= 5 mA to 1A 0.5 1.7 A
Short Circuit Current I
DS
V
IN
= -35V .7 A
(Note 2)
2.0 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 56 dB
V
OUT
(Note 3) 53 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100 KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 120 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
.075 (±.010) TYP.
.040.020 X45°
REF.
.040 X45°
REF (3 PL)
.010
.160 SQ. REF.
.065
.009 R. 20 PLCS.
3
1
19
18
14
4
13
9
.003
.050
TYP.
.050
(±.005)
TYP.
.085
.025 SQ.
TYP.
(±.003)
.025
TYP.
MECHANICAL OUTLINE
Terminal Number
1NC 2V
INput
3NC 4V
OUTput
5V
OUTput
6NC 7V
OUTput
8NC
9NC 10 NC 11 NC 12 NC 13 NC 14 NC 15 Ground 16 NC 17 Ground 18 NC 19 NC 20 V
INput
Note: The input pins (2 and 20) are to be connected together, the output pins (4,5, and 7) are to be connected together and the ground pins (15 and 17) are to be connected together for operation.
PIN CONNECTION
OM1905N2M - OM1915N2M
3.5
ELECTRICAL CHARACTERISTICS -15 Volt V
IN
= -23V, Io= 100mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -14.85 -15.15 V
V
IN
= -17.5V to -30V -14.55 -15.45 V
I
O
= 5 mA to 500 m A, PD < 2 W
Line Regulation V
RLINE
VIN= -17.5V to -30V 25 mV
(Note 1)
50 mV
(Note 4) V
IN
= -20V to -26V 15 mV
25 mV
Load Regulation V
RLOAD
IO = 5mA to 500 mA 50 mV
(Note 1)
90 mV
Standby Current Drain I
SCD
6.0 mA
6.5 mA
Standby Current Drain ∆I
SCD
VIN= -17.5V to -30V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 500 mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=500 mA 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 0.5 1.7 A
Short Circuit Current I
DS
VIN= -35V 0.7 A
(Note 2)
2.0 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 53 dB
V
OUT
(Note 3) 50 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 150 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
Loading...