Omega Products OMB-DBK82 User Manual

H-55
OMB-DBK81, OMB-DBK82, OMB-DBK83, OMB-DBK84 7 & 14 Channel Low-Noise, High Accuracy,
Thermocouple and mV Expansion Options for the OMB-LOGBOOK & OMB-DAQBOARD-2000 Series
Measures Type J, K, T, E,
R, S, B & N Thermocouples as well as Voltage up to ±100mV
Low Noise, High Accuracy,
High Stability 100 kHz Maximum Scan Rate, Compatible with all OMB-LOGBOOK and OMB-DAQBOARD-2000 Series Operating at Maximum Sampling Rates
High Noise ImmunityOpen Thermocouple
Detection Per Channel
Over-Voltage Protection
Available in Four Different Form-Factors:
7 Channel Card with
On-Board Screw-Terminals, Model OMB-DBK81
Model OMB-DBK81
$
549
The new OMB-DBK81/82/83/84 are designed to provide very low noise thermocouple and milli-volt measurements, with high accuracy and very close tracking between channels. These new models provide thermocouple accuracy of better than
0.5°C, and noise that is typically less than 0.2°C p-p, with no digital averaging required.
The performance of these new OMB-DBK cards is enabled through their use of very low-noise amplifiers on every channel. Built-in cold junction
The OMB-DBK81 provides 7 differential thermocouple/mV inputs, and installs into any OMB-LOGBOOK and OMB-DBK enclosure. The OMB-DBK81 provides on-board screw-terminals for connection of thermocouple/ mV signals directly to the card.
The OMB-DBK82 provides 14 differential channels of thermocouple/mV inputs, and is physically taller than other OMB-DBK cards. The OMB-DBK82 installs into an OMB-DBK60 where it can be wired directly to the mini-thermocouple connector panels. Note that the OMB­DBK82 will not install into a single-height slot in the OMB-DBK10. Further, the OMB-DBK82 consumes two expansion slots in the OMB-DBK41 10-slot enclosure.
compensation and software-based linearization automatically provides you with quiet and stable temperature measurements, with no need to deal with the usual complexities associated with thermocouple measurements.
All software that supports the OMB-DAQBOARD-2000 Series and OMB-LOGBOOK also support these new OMB-DBK options, providing you with accurate and stable temperature readings on every channel. Four different models are offered so you can choose the one that best fits your application.
14 Channel Card with
On-Board Screw-Terminals, Model OMB-DBK82
14 Channel Card with
External Signal Connection "Pod" with Removable Screw-Terminals, Model OMB-DBK83
14 Channel Module
(Metal Housing with Mini-Thermocouple Connections)
OMB-DBK81, $549, shown
smaller than actual size
OMEGACARESMextended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE
SM
covers parts, labor and equivalent loaners.
H-56
H
The OMB-DBK83 provides 14 differential channels of input (like the OMB-DBK82), but instead of on-board screw-terminals, it includes an external thermocouple/mV connection pod with removable screw-terminals. This allows the OMB-DBK83 to install into single-slot housings, including the OMB-DBK10 and the OMB-DBK41. The OMB-DBK83 also allows thermocouple connections to reside away from the OMB-LOGBOOK or OMB-DAQBOARD-2000, reducing the length of thermocouple wire required. The OMB-DBK83 also makes it easy to remove all signal connections by disconnecting one cable from the pod, or by removing the 15-pin screw-terminal connection. A 1 meter (3ft) cable is included with the OMB-DBK83.
The OMB-DBK84 is a 14-channel module with built-in mini-thermocouple connectors. The OMB-DBK84 can mechanically attach directly to any OMB-LOGBOOK or OMB-DBK modules or enclosures. The OMB-DBK84 is best suited for applications where mini-thermocouple connectors are in use, and where quick attachment and removal of thermocouples is desired.
Specifications
System Connector: All OMB-DBK options
have a DB37 male, which mates with P1 on the OMB-DAQBOARD-2000 or OMB-LOGBOOK or other OMB-DBK options.
Thermocouple/mV Connector: OMB-DBK81: Board-mounted screw-terminals OMB-DBK82: Board-mounted screw-terminals OMB-DBK83: External pod-mounted
removable screw-terminals
OMB-DBK84: Mini-thermocouple connectors Input Types: thermocouple types J, K, T, E, R,
S, B, N; x100 (voltage)
Inputs: OMB-DBK81: 7 differential
thermocouple/mV inputs OMB-DBK82/83/84: 14 differential thermocouple/mV inputs
Input Voltage Range: ±100mV* Input Impedance: 40M(differential);
20M(single-ended)
Input Bandwidth: 4 Hz Input Bias Current: 10nA typ CMRR: 100dB typ Maximum Working Voltage (signal + common mode): ±10V Over-Voltage Protection: ±40V Power Requirements: OMB-DBK81: 35mA max from ±15V;
2mA max from ±5V OMB-DBK82: 60mA max from ±15V; 2mA max from ±5V OMB-DBK83: 60mA max from ±15V; 2mA max from ±5V OMB-DBK84: 60mA max from ±15V; 2mA max from ±5V Operating Temperature: 0 to 50°C (32 to 122°F)
Voltage Accuracy: ±(0.2% of rdg + 50 mV) Minimum Resolution: 0.1°C for all
thermocouple types Thermocouple Accuracy: Valid for one year, 18 to 28°C (see table)
* ±100mV with an OMB-LOGBOOK; ±50mV with an OMB-DAQBOOK or DAQBOARD **Accuracy conditions: using a DAQBOARD calibrated within 1 year; accuracy numbers reflect total system absolute accuracies, including accuracy of the CJC and DAQBOARD; exclusive of thermocouple errors; exclusive of noise; VCM=0
To Order
(Specify Model Number)
Model No. Price Description
OMB-DBK81 $549 7-channel thermocouple/mV card with
screw-terminal connections
OMB-DBK82 849 14-channel thermocouple/mV card with
screw-terminal connections
OMB-DBK83 999 14-channel thermocouple/mV card with external
screw-terminal pod and 1 m (3') cable
OMB-DBK84 1099 14-channel thermocouple/mV module with mini
thermocouple input connectors
OMB-POD-1 199 Extra screw-terminal pod for OMB-DBK83 OMB-CA-239 41 Extra 1 m (3') cable for OMB-DBK83
Ordering Example: OMB-DBK82 14-channel thermocouple/mV card with screw-
terminal connections and OMEGACARESM1-year extended warranty for OMB-DBK82 (adds 1 year to standard 1-year warranty), $849 + 83 = $932.
Type Min Max -100 100 300
J -200 760 0.6 0.5 0.6 K -200 1200 0.7 0.6 0.7 T -200 400 0.7 0.6 0.6 E -270 650 0.6 0.5 0.5 S -50 1768 1.8 1.5 R -50 1768 1.6 1.5 B 50 1780 3.7
N28 -270 400 0.9 0.7 0.7 N14 0 1300 0.7 0.7
Type 500 700 900 1100 1400
J 0.7 0.7 – K 0.8 0.8 0.9 1.0 – T––––– E 0.6 – S 1.5 1.4 1.5 1.6 1.6 R 1.4 1.4 1.3 1.4 1.5 N 2.4 2.1 1.8 1.7 1.5
N28 – N14 0.8 0.8 0.9 1.0
Thermocouple Accuracy at Measurement Temperature in °C (±°C)
OMB-DBK82, $849,
OMB-DBK83, $999
OMB-DBK84, $1099,
AVAILABLE FOR FAST DELIVERY!