Omega Products OMB-DBK7 User Manual

Programmable from 1 Hz
to 950 kHz Per Channel
Frequency Resolution
to 0.00025 Hz
Provides Per-Channel,
User-Configurable Low-Pass Filters
The OMB-DBK7 frequency-input card provides OMB-LOGBOOK and OMB-DAQBOARD-2000 Series data acquisition systems with four channels of frequency­measurement capability. The card measures the input signal’s frequency and converts the frequency to a voltage, which can then be measured by the data acquisition system. The OMB-DBK7’s output is read by the data acquisition system along with any other analog channels included in the analog scan group, allowing easy correlation of readings from the OMB-DBK7 with other test parameters. As many as as sixty­four OMB-DBK7’s can be connected to one OMB-LOGBOOK and OMB-DAQBOARD-2000 series acquisition system, for a total of up to 256 channels.
Analog Inputs
The OMB-DBK7 accepts AC-coupled analog inputs up to 80 V p-p. Each of its channels is equipped with a low-pass input filter that is jumper selectable for 100 kHz, 300 Hz, or 30 Hz.
OMB-DBK7
4-Channel Frequency-Input Card for OMB-DAQBOARD-2000 Series and OMB-LOGBOOK
OMB-DBK7, 749, frequency-input card, shown smaller than actual size
The card can accommodate 1 Hz to 100 kHz measurement of signals from 50 mV to 80 V p-p.
Digital Inputs
The OMB-DBK7’s digital inputs, which can measure signals from
0.001 Hz to 950 kHz, feature TTL Schmitt-trigger levels and can accept DC-coupled signals from -15 V to +15 V. The OMB-DBK7’s digital inputs are equipped with pull-up resistors for use with relays or switches.
Frequency Range
The OMB-DBK7 provides 12-bit resolution at any frequency from 1 Hz to 950 kHz.
Update Rates
For ranges from 1 Hz to the user­defined maximum upper range boundary, the voltage conversion update will occur every 2 to 4 ms or the period of the input frequency, whichever is greater. With a range of 0 to 10 kHz, the OMB-DBK7 will update every 2 to 4 ms. If the range is 0 to 60 Hz, the output will update every cycle or 16.6 ms.
Specifications
Connector: DB37 male, mates
with P1 connector on the OMB-LOGBOOK and OMB­DAQBOARD-2000 Series; BNC connectors for signal inputs
Number of Channels per Card: 4 Maximum Cards per System: 64 Frequency-to-Voltage Ranges:
Programmable from 1 Hz to 950 kHz
Accuracy: 0.1% Low-Pass Filters: 300 Hz & 30 Hz Debouncing: off 0.6, 2.5, & 10 ms Input Characteristics Low-Level Analog Signals
Minimum: 100 mV guaranteed Maximum: 80 V p-p sine wave Minimum Slew: 5 V/s Hysteresis: 15 mV Impedance: AC-coupled (0.33 µF),
in series with 20 Kto ground
High-Level Analog Signals
Minimum: 1.25 V guaranteed Maximum: 80 V p-p sine wave Minimum Slew: 50 V/s Hysteresis: 250 mV Impedance: AC-coupled (0.33 µF),
in series with 20 Kto ground
Digital Signals
Input Voltage: -15 V to +15 V Threshold Voltage (low):
0.8 V typ, 0.5 V min
Threshold Voltage (high):
1.6 V typ, 2.1 V max
Hysteresis: 400 mV min Pulse Width: 520 ns min Input Impedance: 27 Kpull-up
to +5 V in parallel with 50 pF
Power Consumption: 420 mW
Ordering Example: OMB-DBK7 4-channel frequency-input card, $749.
To Order (Specify Model Number)
Model Number Price Description
OMB-DBK7 $749 4-Channel Frequency-Input Card
H-61
Model OMB-DBK7
$
749
AVAILABLE FOR FAST DELIVERY!
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...