⻬ Programmable from 1 Hz
to 950 kHz Per Channel
⻬ Frequency Resolution
to 0.00025 Hz
⻬ Provides Per-Channel,
User-Configurable
Low-Pass Filters
The OMB-DBK7 frequency-input
card provides OMB-LOGBOOK
and OMB-DAQBOARD-2000
Series data acquisition systems
with four channels of frequencymeasurement capability. The
card measures the input signal’s
frequency and converts the
frequency to a voltage, which
can then be measured by the
data acquisition system. The
OMB-DBK7’s output is read by the
data acquisition system along with
any other analog channels included
in the analog scan group, allowing
easy correlation of readings from
the OMB-DBK7 with other test
parameters. As many as as sixtyfour OMB-DBK7’s can be connected
to one OMB-LOGBOOK and
OMB-DAQBOARD-2000 series
acquisition system, for a total of
up to 256 channels.
Analog Inputs
The OMB-DBK7 accepts
AC-coupled analog inputs up to
80 V p-p. Each of its channels is
equipped with a low-pass input filter
that is jumper selectable for 100
kHz, 300 Hz, or 30 Hz.
OMB-DBK7
4-Channel Frequency-Input Card for
OMB-DAQBOARD-2000 Series and OMB-LOGBOOK
OMB-DBK7, 749,
frequency-input
card, shown
smaller than
actual size
The card can accommodate 1 Hz to
100 kHz measurement of signals
from 50 mV to 80 V p-p.
Digital Inputs
The OMB-DBK7’s digital inputs,
which can measure signals from
0.001 Hz to 950 kHz, feature TTL
Schmitt-trigger levels and can accept
DC-coupled signals from -15 V to
+15 V. The OMB-DBK7’s digital
inputs are equipped with
pull-up resistors for use with relays
or switches.
Frequency Range
The OMB-DBK7 provides 12-bit
resolution at any frequency from
1 Hz to 950 kHz.
Update Rates
For ranges from 1 Hz to the userdefined maximum upper range
boundary, the voltage conversion
update will occur every 2 to 4 ms
or the period of the input frequency,
whichever is greater. With a range
of 0 to 10 kHz, the OMB-DBK7 will
update every 2 to 4 ms. If the range
is 0 to 60 Hz, the output will update
every cycle or 16.6 ms.
Specifications
Connector: DB37 male, mates
with P1 connector on the
OMB-LOGBOOK and OMBDAQBOARD-2000 Series; BNC
connectors for signal inputs
Number of Channels per Card: 4
Maximum Cards per System: 64
Frequency-to-Voltage Ranges:
Programmable from 1 Hz to 950 kHz
Accuracy: 0.1%
Low-Pass Filters: 300 Hz & 30 Hz
Debouncing: off 0.6, 2.5, & 10 ms
Input Characteristics
Low-Level Analog Signals
Minimum: 100 mV guaranteed
Maximum: 80 V p-p sine wave
Minimum Slew: 5 V/s
Hysteresis: 15 mV
Impedance: AC-coupled (0.33 µF),
in series with 20 KΩ to ground
High-Level Analog Signals
Minimum: 1.25 V guaranteed
Maximum: 80 V p-p sine wave
Minimum Slew: 50 V/s
Hysteresis: 250 mV
Impedance: AC-coupled (0.33 µF),
in series with 20 KΩ to ground
Digital Signals
Input Voltage: -15 V to +15 V
Threshold Voltage (low):
0.8 V typ, 0.5 V min
Threshold Voltage (high):
1.6 V typ, 2.1 V max
Hysteresis: 400 mV min
Pulse Width: 520 ns min
Input Impedance: 27 KΩ pull-up
to +5 V in parallel with 50 pF
Power Consumption: 420 mW
Ordering Example: OMB-DBK7 4-channel frequency-input card, $749.
To Order (Specify Model Number)
Model Number Price Description
OMB-DBK7 $749 4-Channel Frequency-Input Card
H-61
Model OMB-DBK7
$
749
AVAILABLE FOR FAST DELIVERY!
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement
Force Sensors, Instrumentation for Pressure and Strain
Measurements, Load Cells, Pressure Gauges, Pressure
Reference Section, Pressure Switches, Pressure Transducers,
Proximity Transducers, Regulators,
Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page