Omega Products FTB-932 User Manual

ECONOMICAL BALL BEARING GAS TURBINE FLOWMETERS
with Male NPT Fittings
FTB-930/940
Series
U
±1% of Reading Accuracy
U Ball Bearing Design
for Economy
U 440C Bearing Retainers
for Durability
U Ball Bearings Field
Replaceable Without Loss of Calibration
U Deflector Cones Stabilize
Low-Mass Rotor for Increased Bearing Life
U NIST Certificate
Supplied Standard
The OMEGA® FTB-930 and FTB-940 Series turbine meters have male NPT end fittings for easy connections. They are suitable for use with gases with a minimum density of 0.025 lb/ft is 0.0752 lb/ft supplied with a mating 2-wire connector and can be supplied with integrally mounted FLSC-60 Series signal conditioners to provide 4 to 20 mA, 0 to 5V, or amplified pulse outputs. These turbine gas meters are intended for clean service only; where there is any doubt about the fluid, strainers are recommended.
3
3
(air at STP
).These units come
Standard
OMEGA® precision turbine gas flowmeters are designed to measure actual cubic feet or actual volume passing through the meter. Before sizing a flowmeter, it is necessary to convert flow units (i.e., SCFM, LPM, etc.) to actual units. To convert to actual measured volume (ACFM) from standard volume (SCFM), use the following formula:
ACFM = SCFM x 14.7/Pa x Ta/530
where:
ACFM = Actual cubic feet per minute of measured gas flow
SCFM = Standard cubic feet per minute gas flow
Pa = Operating pressure (psia) in = (psig + 14.7)
Ta = Temperature in degrees Rankine = (°F + 460)
SPECIFICATIONS
Accuracy: ±1.0% of reading Repeatability: ±0.25% Materials of Construction:
Body: 304/316 stainless steel Rotor: 17-4 PH SS
Bearings: 440C stainless steel Output: 30 mV p-p sinewave min
FTB-939 turbine shown with FLSC-61 signal conditioner. Visit omega.com/flsc60
Compatible Meters: DPF701, DPF402,
DPF70 with FLSC-AMP, DPF10, FC21, 22
Visit omega.com/meters
Electrical: 2-wire connector included Maximum Temp. Range:
-267 to 232°C (-450 to 450°F) Maximum Pressure Drop:
Gas density in lb/ft
3
x 4 (psid)
F
To Order Visit omega.com/ftb930 for Pricing and Details
Maximum Nominal Operating End Approx Linear Range K-Factor Pressure Length Connections Weight
Model No.
FTB-931B 0.35 to 3.5 24,200 5000 76 (3) ¹⁄₂ 1 (2) FTB-932 0.75 to 5 14,890 5000 76 (3) ¹⁄₂ 1 (2) FTB-933 1 to 10 14,580 5000 76 (3) ¹⁄₂ 1 (2) FTB-934 2 to 20 8790 5000 76 (3) ¹⁄₂ 1 (2) FTB-935 2.5 to 28 3660 4000 83 (3.25) ³⁄₄ 2 (4) FTB-936 4 to 60 880 3000 89 (3.50) 1 2.5 (5) FTB-937 6 to 100 720 2500 98 (3.88) 1¹⁄₄ 3 (7) FTB-938 8 to 130 430 2000 111 (4.38) 1¹⁄₂ 3.5 (8) FTB-939 15 to 250 230 1500 121 (4.75) 2 6 (13) FTB-940 25 to 450 135 1500 154 (6.06) 2¹⁄₂ 8 (18) FTB-941 40 to 650 74 1250 254 (10) 3 8.5 (19) FTB-942 70 to 1200 4.6 1000 305 (12) 4 16 (36)
Comes complete with mating connector, operator’s manual and NIST certificate for air.
Ordering Examples: To order a scaled system that includes signal conditioner, turbine meter with MNPT end fittings, specify model number. SYS/FTB-931B/FLSC-61, FTB-931B flowmeter with 0.35 to 3.5 ACFM range, and FLSC-61, 0 to 5V/10V signal conditioner. SYS/FTB-939/FLSC-62A, FTB-939 flowmeter with 15 to 250 ACFM range, and FLSC-62A, 4 to 20 mA signal conditioner.
(ACFM) (p/ACF) (psi) mm (inch) MNPT (inch) kg (lb)