ECONOMICAL BALL BEARING
GAS TURBINE FLOWMETERS
with Male NPT Fittings
FTB-930/940
Series
U
±1% of Reading Accuracy
U Ball Bearing Design
for Economy
U 440C Bearing Retainers
for Durability
U Ball Bearings Field
Replaceable Without
Loss of Calibration
U Deflector Cones Stabilize
Low-Mass Rotor for
Increased Bearing Life
U NIST Certificate
Supplied Standard
The OMEGA® FTB-930 and
FTB-940 Series turbine meters
have male NPT end fittings for easy
connections. They are suitable
for use with gases with a minimum
density of 0.025 lb/ft
is 0.0752 lb/ft
supplied with a mating 2-wire
connector and can be supplied with
integrally mounted FLSC-60 Series
signal conditioners to provide
4 to 20 mA, 0 to 5V, or amplified
pulse outputs. These turbine gas
meters are intended for clean
service only; where there is any
doubt about the fluid, strainers are
recommended.
3
3
(air at STP
).These units come
Standard
OMEGA® precision turbine gas
flowmeters are designed to measure
actual cubic feet or actual volume
passing through the meter. Before
sizing a flowmeter, it is necessary to
convert flow units (i.e., SCFM, LPM,
etc.) to actual units. To convert to
actual measured volume (ACFM)
from standard volume (SCFM), use
the following formula:
ACFM = SCFM x 14.7/Pa x Ta/530
where:
ACFM = Actual cubic feet per
minute of measured gas flow
SCFM = Standard cubic feet per
minute gas flow
Pa = Operating pressure
(psia) in = (psig + 14.7)
Ta = Temperature in degrees
Rankine = (°F + 460)
SPECIFICATIONS
Accuracy: ±1.0% of reading
Repeatability: ±0.25%
Materials of Construction:
Body: 304/316 stainless steel
Rotor: 17-4 PH SS
Bearings: 440C stainless steel
Output: 30 mV p-p sinewave min
FTB-939 turbine
shown with
FLSC-61 signal
conditioner. Visit
omega.com/flsc60
Compatible Meters: DPF701, DPF402,
DPF70 with FLSC-AMP, DPF10, FC21, 22
Visit omega.com/meters
Electrical: 2-wire connector included
Maximum Temp. Range:
-267 to 232°C (-450 to 450°F)
Maximum Pressure Drop:
Gas density in lb/ft
3
x 4 (psid)
F
To Order Visit omega.com/ftb930 for Pricing and Details
Maximum Nominal Operating End Approx
Linear Range K-Factor Pressure Length Connections Weight
Model No.
FTB-931B 0.35 to 3.5 24,200 5000 76 (3) ¹⁄₂ 1 (2)
FTB-932 0.75 to 5 14,890 5000 76 (3) ¹⁄₂ 1 (2)
FTB-933 1 to 10 14,580 5000 76 (3) ¹⁄₂ 1 (2)
FTB-934 2 to 20 8790 5000 76 (3) ¹⁄₂ 1 (2)
FTB-935 2.5 to 28 3660 4000 83 (3.25) ³⁄₄ 2 (4)
FTB-936 4 to 60 880 3000 89 (3.50) 1 2.5 (5)
FTB-937 6 to 100 720 2500 98 (3.88) 1¹⁄₄ 3 (7)
FTB-938 8 to 130 430 2000 111 (4.38) 1¹⁄₂ 3.5 (8)
FTB-939 15 to 250 230 1500 121 (4.75) 2 6 (13)
FTB-940 25 to 450 135 1500 154 (6.06) 2¹⁄₂ 8 (18)
FTB-941 40 to 650 74 1250 254 (10) 3 8.5 (19)
FTB-942 70 to 1200 4.6 1000 305 (12) 4 16 (36)
Comes complete with mating connector, operator’s manual and NIST certificate for air.
Ordering Examples: To order a scaled system that includes signal conditioner, turbine meter with MNPT end fittings, specify model number.
SYS/FTB-931B/FLSC-61, FTB-931B flowmeter with 0.35 to 3.5 ACFM range, and FLSC-61, 0 to 5V/10V signal conditioner.
SYS/FTB-939/FLSC-62A, FTB-939 flowmeter with 15 to 250 ACFM range, and FLSC-62A, 4 to 20 mA signal conditioner.
(ACFM) (p/ACF) (psi) mm (inch) MNPT (inch) kg (lb)