InstallatIon InstructIons
1. Your meter should be installed with the arrow pointed in the direction of flow. You can rotate the computer electronics 180 degrees before you install the computer.
2. Check that the batteries are secure in the back of the
computer.
4. Check meter accuracy before using. Make sure there is no air in the system by starting the flow until it runs steadily. Then stop the flow using a valve or nozzle.
5. Hold down DISPLAY button for three seconds to zero the meter’s Batch Total. When zeroes appear, release the button.
6. Meter an exact known volume into an accurate container. For best results, meter with one continuous full stream.
7. Check the readout. If the amount metered is accurate, field calibration is not necessary. If not, refer to the Calibration
Section in your Owner’s Manual.
This Kit includes:
• Replacement Computer Assembly with Two Lithium Batteries
• Four Screws
• One O-Ring
Use with Kits:
FTB691-CK
FTB692-CK
FTB693-CK
FTB694-CK
FTB695-CK