Omega Products FTB2001-C User Manual

78
10
Economical Flow RatE SEnSoRS
Both shown larger
FTB2000 Series
U Low Cost U High Accuracy
(±3% of Reading)
U Measures Low
Liquid Flow Rates of 0.13 to 7.9 GPM
U FDA-Approved
Materials
U Lightweight Plastic
Design Permits Mounting in Any Position
The FTB2000 Series hall-effect turbine flow rate sensors are ideal for OEM applications involving low-flow liquid monitoring. The low cost, coupled with ¹⁄₂% repeatability, makes it suitable for replacing dispensing timer systems. Unlike traditional timing systems, turbine technology is not influenced by changes in system pressure caused by aging filters. The sensor’s standard power and output specifications make it easy to retrofit to existing controllers.
SPECIFICATIONS
Wetted Materials
Body: Nylon 12 Turbine: Nylon 12 composite Accuracy: ±3% of reading Repeatability: 0.5% FS Bearings: PTFE/15% graphite Operating Pressure: 200 psig Operating Temperature:
-20 to 100°C (-4 to 212°F) Viscosity: 32 to 81 SSU (0.8 to 16 centistokes)
Filter: <50 microns Input Power: 5 to 24 Vdc @ 8 mA Output: NPN sinking open collector
@ 50 mA maximum (1 to 2.2 kΩ pull-up resistor required) (Hz output) Electrical Connection: Spade terminals 2.8/6.3 x 0.8 mm (0.110/0.248 x 0.031")
Inlet/Outlet Ports: Cable: 1 m (3') (-C models)
3
8 MNPT
22 (87)
(0.118)
To Order Visit omega.com/ftb2000 for Pricing and Details
³⁄₈ NPT Flow Range Pulses per Model No. Model No. GPM LPM Gallon Liter
FTB2001 FTB2001-C 0.13 to 1.3 0.5 to 5 26200 6900 58 to 575 Hz FTB2002 FTB2002-C 0.26 to 2.7 1 to 10 12500 3300 55 to 550 Hz FTB2003 FTB2003-C 0.13 to 2.0 0.5 to 7.5 17400 4600 38 to 575 Hz FTB2004 FTB2004-C 0.26 to 4.0 1 to 15 8300 2200 37 to 550 Hz FTB2005 FTB2005-C 0.26 to 6.6 1 to 25 3800 1000 16.7 to 416 Hz
FTB2006 FTB2006-C 0.53 to 9.2 2 to 35 2840 750 25 to 437 Hz
Accessories (For units without integral cable)
Model No. Description FTB173941 Mating connector with 0.9 m (3'), 3-conductor, PVC pigtail leads FTB173942 Mating connector with 3 m (10'), 3-conductor, PVC pigtail leads
Comes complete with operator’s manual. Ordering Example: FTB2002, turbine meter, plus FTB173942, mating connector with
3 m (10') cable.
than actual size.
FTB2001
Dimensions: mm (inch)
0.67 (17)
30
(0.20)
5
Wiring
FL O W
13.3
(0.52)
(2.17)
55
F-83
(11)
White
Bla c k
Red
2.8
6.3
(0.25)
3/8 NPT
1 to 2.2k Ω
CUS T OME R SUPPLIED
(-)
(+)
(0.39)
(0.20)
17
(0.70)
Output O Vdc
5 to 24 Vdc
5
8
(0.31)
DPF700 Series compatible meter, shown smaller than actual size. Visit omega.com/dpf700
Pressure Drop—Typical
18
16
14
12
10
8
6
4
2
0
0 0.25 0.50 122.5 3456
Tests conducted with water at 20°C (68°F)
FTB2001-C
A
B
Flow Rate-GPM
A) All Others B) FTB2004, FTB2005
Frequency
Output
Loading...