H-67
@ minimum ac supply
Supply and Load Variation
Effect: < 0.03% for full
change
Output Ripple: better
than 0.1% of span RMS
Frequency: 40-500 Hz
Output: 4-20 mA
Zero Adjust: ±35% min
Span Adjust: ±25% min
Operating Ambient: 32
to 158°F (0 to 70°C); 5 to
95% RH, noncondensing
Storage Temperature:
-13 to 185°F (-25 to 85°C)
Enclosure:
polycarbonate
Mounting: standard 35
mm DIN rail or wall mount
Dimensions: 2.87" H x
1.77" W x 4.69" D (73 x
45 x 119 mm)
Weight: 0.9 lb (0.4 kg)
DRA-ACT-4I SERIES
(AC CURRENT INPUT)
Input: 0-1 Aac, 0-5 Aac
Input Power
Consumption: 0.26 VA
at 5 Aac input
Isolation: Current Input:
2.5 KV RMS/1 min; Power
Input: 4 KV RMS/1 min
Inrush Current: 40 Aac
RMS max for 8 sec every
10 min; 75 Aac RMS max for 1 sec
every 10 min
DRA-ACT-4V (AC VOLTAGE
INPUT)
Input: 0-150 Vac, 0-250 Vac,
To Order
(Specify Model Number)
DRA-ACT-4I ac current input models*
Model No. Price Description
DRA-ACT-4I-1 $220 0 to 1 A ac input, 4 to 20 mA output
DRA-ACT-4I-2 220 0 to 5 A ac input, 4 to 20 mA output
DRA-ACT-4V ac voltage input models*
DRA-ACT-4V-1 220 0 to 150 Vac input, 4 to 20 mA output
DRA-ACT-4V-2 220 0 to 250 Vac input, 4 to 20 mA output
DRA-ACT-4V-3 220 0 to 400 Vac input, 4 to 20 mA output
DRA-ACT-4I Series AC
Current Input
DRA-ACT-4V Series AC
Voltage Input
U ± 0.1% Accuracy
U Isolated
U 4-20 mA Output
U Low Profile Enclosure
* Standard power is 115 Vac, 50/60 Hz. To order unit configured for 230 Vac, 50/60 Hz power,
add suffix “-230” to model no., no additional charge.
Comes with complete operators manual.
Ordering Example: DRA-ACT-4V-2, ac voltage signal conditioner, 0 to 250 Vac input,
4 to 20 mA output, $220.
$
220
Basic Unit
The DRA-ACT-4I AND
DRA-ACT-4V Series are isolated
4-wire ac current and ac voltage
input DIN rail mount signal
conditioners that convert the
measured input into a proportional,
linear and highly accurate 4-20 mA
output current. The DRA-ACT-4I
Series of ac current input models
includes models for 0-1 Aac and
0-5 Aac inputs with a 4-20 mA
output. The DRA-ACT-4V Series of
ac voltage input models includes
models for 0-150 Vac, 0-250 Vac
and 0-400 Vac inputs again with a
4-20 mA output. Standard
instrument power is 115 Vac, 50/60
Hz. Units can also be configured for
optional 230 Vac, 50/60 Hz power.
For complete safety, an internal
transformer isolates the signal
conditioner input from the output
thus enabling these units to
withstand large momentary inputs.
Complete input to output isolation,
high surge current capacity and high
output signal-to-noise ratio make
these signal conditioners highly
immune to ground loop signals and
RFI. Zero and span trimmers
accessible from the front panel of
these units facilitate fine tuning.
Specifications
GENERAL
Accuracy: ±0.1% of span typical
(2-100% of span) for pure
sinusoidal input
Temperature Stability: 0.02%/1°C
CMR: 122 dB typical; 117 dB min
Response Time: 220 msec
(0-98%)
Power Supply: 115 Vac ± 15%,
50/60 Hz standard; 230 Vac ± 15%,
50/60 Hz optional
Power Consumption: 1.9 VA
Loop Resistance: 750 Ohms @
nominal ac supply; 600 Ohms
DRA-ACT-4 DIN Rail Mount AC
Voltage/Current Signal Conditioners
4-Wire AC Powered Design
0-400 Vac
Input Power Consumption: 0.3 VA
at 120 Vac input; 1.4 VA at
230 Vac input
Isolation: 4 KV RMS/1 minute
OMEGA
CARE
Extended Warranty
Program
SM
A/IN

One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement
Force Sensors, Instrumentation for Pressure and Strain
Measurements, Load Cells, Pressure Gauges, Pressure
Reference Section, Pressure Switches, Pressure Transducers,
Proximity Transducers, Regulators,
Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page