DIN Rail Mount AC Voltage/Current 
Signal Conditioners
2-Wire Loop Powered Design
H-66
H
To Order 
(Specify Model Number)
Model No. Price Description
DRA-ACT-2I-1 $130 ac current, 0 to 1 A ac input, 4 to 20 mA output 
DRA-ACT-2I-2 130 ac current, 0 to 5 A ac input, 4 to 20 mA output 
DRA-ACT-2V-1 130 ac voltage, 0 to 150 Vac input, 4 to 20 mA output 
DRA-ACT-2V-2 130 ac voltage, 0 to 250 Vac input, 4 to 20 mA output 
DRA-ACT-2V-3 130 ac voltage, 0 to 400 Vac input, 4 to 20 mA output 
DRN-PS-1000 150 Power supply, 95-240 Vac input, 24 Vdc 
@ 1 A output
Comes with complete operator’s manual. 
Ordering Example: DRA-ACT-2I-1, ac current signal conditioner, 0 to1 Aac input, 
4 to 20 mA output, with DRN-PS-1000 power supply, $130 + 150 = $280
$
130
Basic Unit
The DRA-ACT-2I AND 
DRA-ACT-2V Series are isolated 
2-wire loop-powered ac current and 
ac voltage input DIN rail mount 
signal conditioners that convert the 
measured input into a proportional, 
linear and highly accurate 4-20 mA 
output current. The DRA-ACT-2I 
Series of ac current input models 
includes models for 0 to1 Aac and 
0 to5 Aac inputs with 4 to20 mA 
output. The DRA-ACT-2V Series of 
ac voltage input models includes 
models for 0 to150 Vac, 0 to250 Vac 
and 0 to400 Vac inputs again with 
4 to 20 mA output.
For complete safety, an internal 
transformer isolates the signal 
conditioner input from the output 
thus enabling these units to 
withstand large momentary inputs. 
Complete input to output isolation, 
high surge current capacity and high 
output signal-to-noise ratio make 
these signal conditioners highly 
immune to ground loop signals and 
RFI. These transmitters are also 
equipped with a “test” terminal 
which facilitates monitoring of the 
output current by measuring the 
voltage drop across an internal 
10 Ohm resistor without disturbing 
the 4 to 20 mA process loop.
DRA-ACT-2I Series AC 
Current Input
DRA-ACT-2V Series AC 
Voltage Input
U ± 0.1% Accuracy 
U Isolated 
U High Noise Immunity 
U Low Profile Enclosure
Specifications
GENERAL 
Accuracy: ±0.1% of span typical
(2-100% of span) for pure 
sinusoidal input
Temperature Stability: ±0.015% of 
span /1°C
CMR: 122 dB typical; 117 dB min 
Response Time: 220 msec (0-98%) 
Power Supply: 10-32 Vdc 
Loop Resistance: Rmax (ohms) =
(Vsupply 10)/0.02
SUPPLY AND LOAD 
Variation Effect: < 0.03% for full
change 
Test Terminal: 40 to 200 mV
represents 4 to 20 mA 
Output Ripple: better than 0.1% of
span RMS
Frequency: 40 to 500 Hz 
Output: 4 to 20 mA 
Zero Adjust: ±35% min 
Span Adjust: ±25% min 
Operating Ambient:
32 to 158°F (0 to 70°C); 5 to 95% 
RH, noncondensing
Storage Temperature:
-13 to 185°F (-25 to 85°C)
Enclosure: polycarbonate  
Mounting: standard 35 mm DIN rail
or wall mount
Dimensions: 2.87" H x 1.28" W x
4.49" D (73 x 32.5 x 114 mm)
Weight: 0.5 lb (0.2 kg) 
DRA-ACT-2I SERIES 
(AC CURRENT INPUT) 
Input: 0 to 1 Aac, 0 to 5 Aac  
Input Power Consumption: 0.26
VA at 5 Aac input 
Inrush Current: 40 Aac RMS max
for 8 sec every 10 min; 75 Aac RMS 
max for 1 sec every 10 min
DRA-ACT-2V 
(AC VOLTAGE INPUT)
Input: 0 to 150 Vac, 0 to 250 Vac. 
0 to 400 Vac 
Input Power Consumption: 0.3 VA
at 120 Vac input; 1.4 VA at 
230 Vac input 
Isolation: 2.5 KV RMS for one 
minute
A/IN
A/OUT
SM
OMEGA
CARE
Extended Warranty 
    Program

One Omega Drive | Stamford, CT 06907 |  1-888-TC-OMEGA (1-888-826-6342) |  info@omega.com 
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec) 
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 
0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement 
Instruments, Glass Bulb Thermometers, Handheld Instruments 
for Temperature Measurement, Ice Point References, 
Indicating Labels, Crayons, Cements and Lacquers, Infrared 
Temperature Measurement Instruments, Recorders Relative 
Humidity Measurement Instruments, RTD Probes, Elements 
and Assemblies, Temperature & Process Meters, Timers and 
Counters, Temperature and Process Controllers and Power 
Switching Devices, Thermistor Elements, Probes and 
Assemblies,Thermocouples Thermowells and Head and Well 
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level 
Measurement, Magnetic Flowmeters, Mass Flowmeters, 
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel 
Flowmeters, Ultrasonic Flowmeters,  Valves, Variable Area 
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen 
Instrumentation,  Environmental Instrumentation, pH 
Electrodes and Instruments, Water and Soil Analysis 
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, 
Communication Products and Converters, Data 
Acquisition and Analysis Software, Data Loggers 
Plug-in Cards, Signal Conditioners, USB, RS232, RS485 
and Parallel Port Data Acquisition Systems, Wireless 
Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement 
Force Sensors, Instrumentation for Pressure and Strain 
Measurements, Load Cells, Pressure Gauges, Pressure 
Reference Section, Pressure Switches, Pressure Transducers, 
Proximity Transducers, Regulators,  
Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters,  
Comfort Heaters, Controllers, Meters and Switching 
Devices, Flexible Heaters, General Test and Measurement 
Instruments, Heater Hook-up Wire, Heating Cable 
Systems, Immersion Heaters, Process Air and Duct,  
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page