Omega Products DR910 User Manual

Passive Loop Powered Isolator
0–20mA
0–20mA
0–20mA max. 50mA max. 50mA max. 30V
max. 27.5V
IN
0–20mA
LOAD
TEST VOLTAGE
–3dB FREQUENCY
ACCURACY
TEMPERATUR E
<0.1% +<0.02% / 100
1000
70Hz
500V
˜
–20 ... + 65°C – 4 ... + 145°F
M3862X
US> 2.UL+UV+UB; UV < 2,5V
R
B
=
U
B
20mA
20mA
U
S
–2UL–2,5V
U
L
U
V
R
L
R
B
U
S
U
S
U
L
LoadSignal
OUT
Passive Loop Powered Isolator
I+
I–
OUT
IN
I+
I–
5 6
1 2
M3863X
IN
OUT
25
20
15
10
5
0
200
400
600
800
1000
U
V
= 1.7V
U
E
/ V
R
B
/
Extended Warranty
Program
SM
DR910
$
215
Loop PoweredIsolated0 to 20 mA and 4 to 20 mA RangesDIN Rail Mountable
The DR910 passive isolator is used for the electrical isolation and processing of analog 0 to 20 mA or 4 to 20 mA standard current signals. The DR910 provides electrical isolation between the control electronics and process I/O. In addition, interference signals above 75 Hz are effectively suppressed. Input and output circuit do not require separate auxiliary power. The DR910 obtains power from the input signal. The modules are snapped onto symmetrical DIN rails in accordance with EN 50 022.
Voltage Drop (V)
Voltage Drop at Input
Load Resistance (Ω)
93.1 (3.66)
DR910, loop powered isolator, $215, shown smaller than actual size.
RAIL-35-2 DIN rail, $15 sold separately, shown smaller than actual size.
Dimensions: mm (in)
6.2
(0.24)
When using the DR910, ensure that the current-driving voltage of the measuring transducer is sufficient for driving the maximum current of 20 mA, with a power loss of 1.7V (1.7V + (20 mA * RLOAD). Voltage drop across the input is
102.5 (4)
calculated by determining the load resistance of the output loop, drawing a vertical line to the curve (see diagram), then horizontally to the voltage drop. The energy for the supply on the input side is taken from the analog input signal. Due to the dynamic input resistance, a power loss of approximately 1.7V drops at the module input.
Temperature Coefficient:
Specifications
Input Range: 0 to 20 mA, 4 to 20 mA Maximum Input Current/Voltage:
40 mA/18 Vdc
Input Resistance@ 20 mA:
Voltage Drop at Input: See chart Max Input Frequency: <75 Hz Response Time: 5 msec max Output Signal: 0 to 20 mA,
4 to 20 mA
Max Load Resistance:
600 @ 20 mA
Isolation Voltage:
1.5 kV, 50 Hz, for 1 minute
Accuracy: 0.1% of full scale Operating Temperature:
-20 to 65°C
To Order, Call or Shop Online at omega.com
0.002%/K of the measured value
Enclosure: Case body is black, polyester PBT Mounting: Standard DIN style rail, including top hat (T) profile rail according to EN50022—35 x 7.5 Weight: 56 g (2 oz)
AVAILABLE FOR FAST DELIVERY!
To Order
Model No. Price Description
DR910 $215 Passive loop powered isolator RAIL-35-1 10 35 mm (1.4") DIN rail, 1 m (3.3') length RAIL-35-2 15 35 mm (1.4") DIN rail, 2 m (6.6') length
Comes complete with operator’s manual. Ordering Example: DR910, passive loop powered isolator and OCW-1, OMEGACARESM1 year extended warranty for DR910 (adds 1 year to standard 1 year warranty), $215 + 22 = $237.
(Specify Model Number)
OMEGACARESMextended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE covers parts, labor and equivalent loaners.
SM
SM
XX
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...