M-118
M
Specifications
Input Types: J, K, T, E, R, S, B,
Pt100 RTD and thermistor
[2252 Ω @ 25°C (77°F)], 4 to 20 mA,
0 to 100 mV, 0 to 10 Vdc
Cold-Junction Compensation Error:
±1°C max [10 to 40°C (50 to 104°F)]
Open Thermocouple Indication:
“HELP” displayed.
Custom Inputs Available:
Consult Engineering
Scan Rate:
Fixed—2 channels per second
Channel Interval:
Programmable from 1 to 999 seconds
Reliability/Accuracy:
Calibration:
NIST traceable (temperature)
Resolution: 1°C or F
Thermistor: 0.1°C/0.2°F
Process: 9999, 999.9, 99.99, 9.999
Selectable Temperature Units:
Celsius or Fahrenheit
Analog-to-Digital Conversion:
20,000 count A/D converter;
dual-slope integrating converter
Conversion Rate:
7 conversions per second (typical)
Display: Red 7-segment LED display,
7 digits, 20 mm (0.8") high; negative
polarity indication
Over-Range Indication: “HELP”
Display Test: Briefly indicates
8.8.8.8.8.8.8 on power-up
Elapsed Time: Displayed in hours,
minutes and seconds
Format: HH.MM.SS
Power Options:
120 Vac—60 Hz (standard)
220 Vac—50/60 Hz (optional)
8 to 15 Vdc @ 900 mA (optional)
Relay/Open-Collector
Output (Optional):
Relays: SPST, 1 A @ 28 Vdc
or 0.5 A @ 120 Vac
Open Collector Output:
50 mA max (internal 5 Vdc source)
Dimensions/Enclosure:
Case: 192 W x 160 H x 103 mm D
(7.55 x 6.29 x 4.05")
Material: Polystyrene with
crystal-clear polycarbonate lid
Ingress Protection:
Up to IP65 (DIN standard)
Weight: 1.4 kg (3 lb)
To Order
(Specify Model Number)
Model No. Price Description
DPS3304-(*) $595 Dedicated input 4-zone scanner
DPS3307-(*) 695 Dedicated input 7-zone scanner
DPS3314-(*) 695 Programmable input 4-zone scanner
DPS3317-(*) 795 Programmable input 7-zone scanner
Comes with watertight connectors (2) and complete operator’s manual.
Ordering Example: DPS3304-TC-1-5, dedicated input 7-zone scanner, thermocouple input,
240 Vac, with 4 relay outputs, $595 + 100 = $695.
MOST POPULAR MODELS HIGHLIGHTED!
Type Range Accuracy
-200 to 1190°C (-328 to 2174°F) ±1°C ±1 cnt (±2°F ±1 cnt)
-170 to 1365°C (-274 to 2489°F) ±1°C ±1 cnt (±2°F ±1 cnt)
-155 to 400°C (-247 to 752°F) ±1°C ±1 cnt (±2°F ±1 cnt)
-185 to 915°C (-300 to 1675°F) ±1°C ±1 cnt (±2°F ±1 cnt)
0 to 1600°C (32 to 2900°F) ±3°C ±1 cnt (±6°F ±1 cnt)
0 to 1600°C (32 to 2900°F) ±3°C ±1 cnt (±6°F ±1 cnt)
470 to 1800°C (900 to 3300°F) ±3°C ±1 cnt (±6°F ±1 cnt)
RTD-385 (2-Wire) -200 to 800°C (-328 to 1472°F) ±1°C ±1 cnt (±2°F ±1 cnt)
RTD-392 (2-Wire) -100 to 450°C (-148 to 842°F) ±1°C ±1 cnt (±2°F ±1 cnt)
Thermistor -8 to 100°C (17 to 212°F) ±0.5°C ±1 cnt (±1°F ±1 cnt)
Current 1 to 30,000 counts 0.05% ±1 cnt
Millivolt 1 to 30,000 counts 0.05% ±1 cnt
Voltage 1 to 30,000 counts 0.05% ±1 cnt
Ordering Suffix Price Description
-1 N/A 240 Vac
-2 $25 8 to 15 Vdc
Model No. Price Description
RELAY-URM-400 $145 Universal 15 A mechanical 4-relay module
RELAY-URM-800 195 Universal 15 A mechanical 8-relay module
EE-1319 70 Reference Book: Grounding and
Shielding Techniques
Input Code* Programmable Inputs Dedicated Inputs
TC J, K, T, E, 4 to 20 mA, 0 to 10 Vdc J, K, T, E
RTD RTD, 4 to 20 mA, 0 to 10 Vdc RTD
TH Thermistor, 4 to 20 mA, 0 to 10 Vdc Thermistor
R R T/C, 4 to 20 mA, 0 to 10 Vdc R thermocouple
S S T/C, 4 to 20 mA, 0 to 10 Vdc S thermocouple
B B T/C, 4 to 20 mA, 0 to 10 Vdc B thermocouple
MV — 0 to 100 mV
P 100 mV, 4 to 20 mA, 0 to 10 Vdc —
V — 0 to 10 Vdc
C — 4 to 20 mA
Note: Select input code from table below.
Power Options
Accessories
Input Codes
Ordering Suffix Price Description
-3 $175 7 relay outputs (7-channel units)
-4 175 7 open-collector outputs (7-channel units)
-5 100 4 relay outputs (4-channel units)
-6 100 4 open-collector outputs (4-channel units)
Output Options
*Select one input code.