Omega Products DPF5100 User Manual

1
8 DIN MULTI-FUNCTION METER
For Rate, Batch Control And Totalization
DPF6100 Series
U Fast Low-Frequency
Measurement
U Offset from
-99,999 to 999,999 (Any Decimal Point)
Control or Alarm
U Front Panel or RS232
Programming Standard
U Sensor Excitation
Standard
U HI, LO, GO 150 mA
Open-Collector Output Standard
The DPF6000 microprocessor­based, 6-digit, 1⁄8 DIN panel instruments can be configured by front-panel keys or by a PC as a frequency meter/tachometer, frequency-ratio meter, period/ period-average meter, time interval/ time-interval-average meter, reset stopwatch, and cumulative timer or totalizer/1-stage batch controller. Units are available with two signal inputs to provide frequency ratio or time-interval measurements. Five operating modes.
In the frequency meter, the minimum display update rate is equal to 1 period of the frequency input. Thus, very low frequency measurements are displayed and updated faster than most conventional frequency meters. Only two sensors are required to measure the rate of a moving object. The DPF6000 can be set-up as frequency-ratio meter, ideal for monitoring flow ratios.
DPF6100
The DPF6000 can be set-up as an up or down totalizer/1-stage batch controller at rates up to 7 MHz. The display capacity is -99,999 to 999,999 counts with exponential format up to 9.99 E9. Upon AC
To Order Visit omega.com/dpf6000 for Pricing and Details
Model No. Description DPF6100 Dual TTL/CMOS level pulse inputs DPF6200 Non-isolated signal conditioner with excitation DPF6300 Isolated signal conditioner with excitation DPF6400 Dual isolated signal conditioners with excitation DPF6500 Isolated analog-to-frequency signal conditioner
Options
Order Suffix Description
-A Analog output*
-BCD BCD output, isolated, tri-state parallel*
-R Dual 8A form “C” SPDT relays*
-10/32VDC 9.5 to 32 Vdc power
-230VAC 230 Vac power
A, BCD and R options are mutually exclusive; only one may be ordered.
*
Accessories
Model No. Description
DPP-5 ¹⁄₈ DIN panel punch DPF6D Menu-driven PC setup software; download from omega.com SPC18 Clear splash guard, NEMA 4 (IP65) protection
Comes complete with operator’s manual.
Ordering Examples: DPF6100, dual TTL input meter. DPF6300-R, isolated input meter with optional dual relays.
M-7M-7
1
DIN shown larger than actual size.
8
power loss, the latest reading is automatically saved in non-volatile RAM and is restored upon return of power. See next page for complete specifications.
1
8 DIN MULTI-FUNCTION METER
DPF5100/DPF6100 Series-Common Specifications
COMMON SPECIFICATIONS
COMMON (ALL INPUT TYPES)
Update Rate: 60 msec to 99.99 sec,
field programmable Programmable Functions: Frequency,
period, time interval A to B, frequency ratio B/A, totalize
Scale Factor: -99999 to 999999 with a choice of six decimal point positions (9.9.9.9.9.9.), multiply or divide
Offset: -99999 to 999999 with a choice of six decimal point positions (9.9.9.9.9.9.)
Power: 115 Vac; 230 Vac, 10 to 32 Vdc AC Frequency: 49 to 440 Hz Power Consumption, Typical:
7.5 W max Battery Backup: User-supplied
6 to 12 Vdc, 60 mA to maintain operation, 400 mA with display
Dimensions: 48 H x 96 W x 150 mm D (1.9 x 3.8 x 5.9")
Cutout: 45 x 92 mm (1.772 x 3.622")
DISPLAY
Type: 7-segment, orange LED Digit Height: 14.2 mm (0.56") Symbols: -.8.8.8.8.8. and 8.8.8.8.8.8. Decimal Point: Six positions;
programmable; fixed or auto-ranging Leading Zeros: Blank or displayed;
programmable Overflow Indication: Display in
exponential format to 9.99 E9 Update Time: Averaging time + (10 to
40 milliseconds) + communication time Brightness: 100%, 50%, 25%;
programmable Displayed Value: (Measurement scale
factor) + offset Indicator Lights: GATE LED; Low and
High alarm LEDs
Decimal Format: -99999 or 999999 Exponential Format: -9.9 x 10
9.99 x 10
9
9
or
OUTPUT CHARACTERISTICS
Lo, Hi and Go Alarm Outputs: Open-
collectors, active low, 150 mA at 1V
Digit 6: High Level: = 3.5V at 100 µA Low Level: = 0.4V at 1.6 mA Frequency: = 400 Hz + 0.1%
DPF5100 actual size with FP7002 paddlewheel flow sensor, sold separately. Visit omega.com/fp7000
TIME BASE
Internal Clock Reference: 11.059 MHz Stability: +50 ppm over
0 to 60°C range Fine-Calibration Method:
Programmable calibration value Calibration Accuracy at 25°C:
+2 ppm
COMMUNICATION
RS232 OUT, IN and RTS: RS232C
compatible with transmit handshake line (RTS)
Levels: +5V Transmitted Data: Alarm + 6 digits +
decimal point + CR (9 characters) or alarm + 6 digits + decimal point + space + units of measurement + CR (12 characters)
Baud Rate: 1200 or 9600 baud, programmable
Received Data: Complete set-up parameters, no handshake
0 to 20 mA ASCII Out: Open collector (data the same as RS232 OUT)
OPERATION MODES
Frequency/Tachometer Mode– Frequency Range: 10
7 MHz Accuracy at 25°C (Squarewave): ±0.0002% (+2 ppm)
Totalizer Display–Offset (Preset):
-99,999 to 999,999
TTL Input (DPF5100/5200/5300/5400)
Speed and Protection Levels (Jumper Selectable):
7 MHz, 0 to 5V; 100 kHz,
-20 to +25V; 3 kHz, -20 to +25V
1
DIN shown smaller than
8
-6
Hz to
M-8M-8
Isolated Input Sensitivity (Square­Wave Input) (DPF5300/5400 Only):
±10 mV, 0 to 1 kHz; ±25 mV, 0 to 1 kHz; ±50 mV at 100 kHz
NPN or PNP Open-Collector Sensor Excitation Output: 12.4V at 20 mA
ISOLATED ANALOG INPUT (DPF5500)
Ranges: 4 to 20 mA, 0 to 1 mA, 0 to
5V, 1 to 5V, 0 to 10V; user selectable
Accuracy: Better than 99.9% Non-Linearity: 0.05% FS Isolation: 350 Vdc between output
and input
ON/OFF CONTROL AND ALARM OUTPUTS
Standard: Three open-collector
transistors, rated 150 mA sink, 30V Optional BCD Output: 32-bits, display
and alarm data; approx 10 msec to transmit data
Optional Relays: Two, form C (SPDT), rated 8 A, 30 Vdc, or 240 Vac, resistive load; for rate alarm or batch control
Optional Analog Output: Isolated, scalable, internally powered and field selectable for 0 to 10V, 4 to 20 mA, or 0 to 20 mA. Rangeable over 4 left most or right most digits, suitable for rate or total display; 500V isolation from analog output to ground
Min Impedance for 10V: 500 Ω Max External Impedance for 20 mA:
600 Ω
Note: Specifications for DPF6000 units match the equivalent DPF5000 model.