DC VOLTMETER, AMMETER INDICATOR/
CONTROLLER
1
⁄8 DIN
DP2000-AB Series
U ±1999 or ±9999 Count
Display Span
U ±200 mV to ±200V or ±100 mV to
±100V Ranges
U ±20 µA to ±2 A or ±10 µA to
±1 A Ranges
U 1 or 0.1 mV/Count Analog Output
U Front-Panel Accessible
Adjustments
U LED or LCD Display
U Automatic Polarity
U Display Hold and Test
U Screw-Terminal Barrier Strip
INSTRUMENTATION
The DP2000/9000A and DP2000/9000B are a
high-quality ±1999 or ±9999 count DC voltmeter
and ammeter, respectively. The base meters are
digital indicators for use in electrically-noisy industrial
environments. With the addition of analog and control
outputs, these meters can provide two-wire currentloop signals to a central control room and provide local
alarm or control. A
signal and power is standard. A wide range of options
are available.
POWER AND DISPLAY OPTIONS
Six types of power supplies are available: 120 Vac,
240 Vac, 24 Vac, 5 Vdc, isolated 9 to 32 Vdc and
isolated 26 to 56 Vdc. An LED display is standard, an
LCD display is optional and is recommended for viewing
in bright ambient light. A NEMA 4 (IP65) splash-proof
lens cover is available.
Signal input and power connections are made via a
rear barrier terminal strip. The motherboard rear edge
connector provides access to hold and test, polarity,
clock, and the standard analog output and optional
analog outputs. Decimal point positions can be selected
by jumpers.
ANALOG OUTPUT OPTIONS
A 1 mV/count (±2V full-scale) or 0.1 mV/count (±1V fullscale) analog output is standard and is ideal for driving
a strip-chart recorder. An additional analog output
can be provided by an optional vertical plug-in board.
Available output signals are 0 to 5 Vdc, 0 to 10 Vdc,
0 to 1 mA (source or sink) and 4 to 20 mA (source or
sink). The top and bottom of each output range can be
scaled to fit a user-selected display span.
1
DIN case with screw terminals for
⁄
8
DP2000-A4 shown
actual size.
CONTROL OUTPUT OPTIONS
Additional outputs can be provided by a horizontal
upper board. Available options include single-setpoint
control with one 10 A relay, dual-setpoint control
with two 10 A relays, 4 to 20 mA proportional control
(source or sink), time-proportional 2 A solid-state
relay control, and isolated, parallel BCD output.
SPECIFICATIONS
Input Configuration
Configuration: Bipolar, single-ended
Polarity: Automatic
Span Adjustment: ±4%
Conversion
Technique: Auto-zero, dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Voltages: 120, 240 or 24 Vac 10%/-15%
AC Frequency: 49 to 440 Hz
DC Voltages: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc,
isolated to 300 Vp; 5 Vdc ±5%, non-isolated
Power Consumption: 8 W maximum
D-1
D
DC VOLTAGE INPUTS A SERIES
Common Mode
Voltage: 1500 Vp test (354 Vp per IEC spacing)
Rejection (DC to 60 Hz): 120 dB
NMR 50/60 Hz: 75 dB (DP2), 130 dB (DP9)
Environmental
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Relative Humidity: 95% at 40°C (non-condensing)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94V-0 UL-rated polycarbonate
DP2000
CODE*
RANGE
A1
±199.9 mV ±99.99 mV 1 GΩ 0.1 mV 0.01 mV
A2
±1.999 V ±999.9 mV 1 MΩ 1 mV 0.1 mV
A3
±19.99 V ±9.999 V 1 MΩ 10 mV 1 mV
A4
±199.9 V ±99.99 V 1 MΩ 100 mV 10 mV
DC CURRENT INPUTS B SERIES
CODE*
Ordering Example: DP2000-B3, LED 120 Vac, 1 µA/count, DC
current between -1.999 mA and 1.999 mA.
DP2000
RANGE
B1
±19.99 µA ±9.999 µA 10 kΩ 0.01 µA 1 nA
B2
±199.9 µA ±99.99 µA 1 kΩ 0.1 µA 10 nA
B3
±1.999 mA ±999.9 µA 100 Ω 1 µA 100 nA
B4
±19.99 mA ±9.999 mA 10 Ω 10 µA 1 µA
B5
±199.9 mA ±99.99 mA 1 Ω 100 µA 10 µA
B6
±1.999 A ±999.9 mA 0.1 Ω 1 mA 100 µA
DP9000
RANGE
DP9000
RANGE
To Order Visit omega.com/dp2000-ab for Pricing and Details
MODEL NO. DESCRIPTION
DP2
DP9
* Refer to chart above for code options.
Accessory
MODEL NO. DESCRIPTION
DPP-5
Comes complete with operator’s manual.
Ordering Example: DP2000-A2, LED 120 Vac, 1 mV/count, DC voltage between -1.999V and 1.999V.
3½-DIGIT FOR ±1999 COUNT
4-DIGIT FOR ±9999 COUNT
0 0 0 -X A. POWER AND DISPLAY
0
1
2
3
4
5
6
7
8
9
A
B
1
DIN panel punch
⁄
8
0
1
2
3
4
5
6
0
1
2
3
4
5
(*)
-A
(*)
-B
-G
LED; 120 Vac (50/60 Hz)
LCD; 120 Vac (50/60 Hz) (DP2000 only)
LED; 240 Vac (50/60 Hz)
LCD; 240 Vac (50/60 Hz) (DP2000 only)
LED; 9 to 32 Vdc, isolated
LCD; 9 to 32 Vdc, isolated (DP2000 only)
LED; 5 Vdc
LCD; 5 Vdc (DP2000 only)
LED; 24 Vac
LCD; 24 Vac (DP2000 only)
LED; 26 to 56 Vdc, isolated
LCD; 26 to 56 Vdc, isolated (DP2000 only)
B. ANALOG OUTPUTS
1 mV/count (supplied on all units)
0 to 5 Vdc
0 to 10 Vdc
0 to 1 mA (internally driven)
4 to 20 mA (internally driven)
4 to 20 mA (externally driven)
4 to 20 mA (isolated)
C. CONTROL OUTPUTS
None
Dual setpoint, 10 A relay (SPDT)
Proportional 4 to 20 mA
Proportional/time proportioning, 2 A relay
Parallel BCD, isolated
Single setpoint, 10 A relay (SPDT)
D. SIGNAL CONDITIONER INPUTS
DC voltage
DC current
ADDITIONAL OPTIONS
Green LED display
D-2
INPUT
IMPED
INPUT
IMPED
DP2000
RES
DP2000
RES
DP9000
RES
DP9000
RES
ACC
@25°C
±0.05%
of Rdg
±1 (DP2)
±2 (DP9)
counts
ACC
@25°C
±0.05%
of Rdg
±1 (DP2)
±2 (DP9)
counts