Omega Products CN9110A User Manual

1
16 DIN Autotune
Temperature Controllers
CN9000A Series
US
115 V Models
Only
U User Selectable Input
from 9 Thermocouple Types or RTD Input
U Clear 3
High-Brightness Green LED
U 0.1° Resolution to 200° U Constant Setpoint
Deviation Indication
U Auto/Manual Output
Control
U User Select from
Autotune PID, PI, PD, P or On/Off Control
U Independent Second
Setpoint and Output Models
U Comprehensive Alarm
Features Deviation, Full Scale, Loop Break with Latching Option
U Fault Indication for Sensor
Burnout, Sensor Short, Heater Break and Process Diagnostics
U Min/Max Data Storage
and Autotune Diagnostics Eliminates Need for Chart Recorder
U Optional 24 Vac Power U Field Replaceable
Output Modules
The CN9000A digital temperature controllers feature high accuracy and reliability, and the sophisticated PID with approach control for optimal control during start-up and steady-state operation. These units are well suited for a broad range of applications, and are easy to install and operate. The unique, sophisticated autotune algorithm will calculate the optimum PID values, and additionally recommends the best value for cycle time.
1
2 Digit
For most applications, the user need only select the desired input type, simply by using the front pushbuttons. The autotune parameters can be changed by the operator at any time, allowing the operator to fine tune the controller to an individual process.
The microprocessor holds all data in non-volatile memory, with the ability to retain data for 10 years with no power. The CN9000A has a large, 31⁄2 digit green LED readout, with auxiliary indicators for each output, and 3 LED’s to indicate deviation from setpoint.
Selection of all operational controls is made through the keys on the front panel, with the display prompting the user through each step. After the parameters have been set, they can be locked in, simply by removing a jumper located behind the front bezel. The user can select the control mode and parameters, display resolution (1 or 0.1°), and units (°F/°C). The operator can also utilize the ranging feature, which limits the range in which the setpoint may be chosen, or lock out a user from changing the setpoint. The new single setpoint controller has rear termination. The optional second setpoint and output of the CN9000A model can be set for proportional, on-off or latching limit control, and can be set as either a tracking or non-tracking setpoint. Cycle time, proportional band and on-off deadband are all set independently of the primary setpoint.
P-39
Specifications
Accuracy: ±0.25% FS
±1°C (0.5°C in 0.1° resolution mode); 30 min warm-up; see also linearized tolerance from range chart
Control Stability: ±0.15% FS, typical Sample Rate: 3 per second Auto Calibration: Every 5 s, with
re-zero of cold junction compensation Temperature Coefficient: Less than 150 ppm/°C max
External Resistance: 100Ω max Cold Junction Compensation:
0.05 degrees/degree ambient typical Burnout Protection: Fault display, upscale/downscale selectable Display: 3 (0.4") high; 1 or 0.1° resolution; error indication, 3 deviation from setpoint indicators Setpoint 1: Selectable between autotune PID, PDPI, PD or on-off Setpoint 2 (Optional): Deviation alarm high or low, “out of limits,” or not used; proportional or on-off control; set as up to ±127° deviation from setpoint 1 or full scale (independent PV); high or low process alarm; control output for cooling alarm can be latching for limit control
Panel punches
available,
visit omega.com/
panelpunches
CN9111A with KMTSS-125G-6 thermocouple sold separately, visit omega.com/jmtss for details. Shown actual size.
1
⁄2 digit green LED; 10 mm
Companion controller CN9500 Series,
1
32 DIN. Visit omega.com/cn9500
Cycle Time: 0.3, 1, 2, 3, 5, 7, 10, 14, 20,
30, 45, or 60 sec; setpoint 1 or 2 Auto-Tuning: Unit determines proportional band, integral and derivative values, and suggests optimal cycle time (setpoint 1 only) Proportional Band: 0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8, 10, 14, 20 or 100% of span (setpoint 1 or 2) Derivative (Rate): Off, 1, 2, 3, 5, 10, 15, 20, 25, 35, 50, 75, 100, or 200 s; AT value Integral (Auto Reset): Off, 0.2, 0.5, 1, 2, 3, 5, 7, 10, 13, 18, 25, 33, 43, or 600 min Approach Control: Off, 0.5, 1, 1.5, 2, 2.5, 3, 4, or 5 times proportional band Manual Reset: PD, proportional and on-off control; set as degrees deviation from setpoint 1 On-Off Deadband: 0.25, 0.5, 0.75, 1,
1.25, 1.5, 2, 2.5, 3, 4, 5, 7, 10 or 50% FS (setpoint 1 or 2) Power: 24 Vac, 115 Vac, 230 Vac, ±15%, 50 to 60 Hz
Power Consumption: 6 VA Output 1 Relay: SPDT relay,
5 A @ 250 Vac Output 2 Relay: SPDT relay, 3 A @ 250 Vac
dc Pulse Output: Non-isolated 5 Vdc pulse for driving external DC solid state relay
Common Mode Noise Rejection: 140 dB, 240 Vac, 50/60 Hz Normal Mode Noise Rejection: 60 dB, 50 Hz Ambient Operating Range: 4 to 50°C (40 to 122°F)
Dimensions:
48 H x 48 W x 13 mm D bezel (1.89 x 1.89 x 0.5"); 115 mm (4.5") depth behind panel; 154 mm (6.1") with triac voltage or current output Panel Cutout: 45 mm square (1.772");
1
DIN
16
Weight: 0.38 kg (0.84 lb)
OMEGACARESM extended
SM
warranty program is available for models shown on this page. Ask your sales representative for full
Extended Warranty
Program
details when placing an order. OMEGACARESM covers parts, labor, and equivalent loaners.
Input Types and Ranges
Input Linearized Range Linearized Preset Type (Units are °F/°C Switchable) Tolerance Span*
32 to 1470°F 0 to 800°C 1°C/2°F 400°C 32 to 1999°F 0 to 1200°C 1°C/2°F 400°C
-199 to 500°F -199 to 250°C 2°C/4°F 250°C 32 to 1100°F 0 to 600°C 1°C/2°F 500°C 32 to 572°F 0 to 300°C 5°C/9°F
572 to 1999°F 300 to 1600°C 2°C/4°F 32 to 572°F 0 to 300°C 5°C/9°F
572 to 1999°F 300 to 1600°C 2°C/4°F
1600°C
1600°C
1000 to 1999°F 500 to 1800°C 6°C/11°F 1600°C 32 to 1999°F 0 to 1200°C 1°C/2°F 400°C L (J DIN) 32 to 1470°F 0 to 800°C 1°C/2°F 400°C
-199 to 750°F -199 to 400°C 0.5°C/0.9°F 200°C
User adjustable limit on setpoint.
*
To Order Visit omega.com/cn9000a for Pricing and Details
Model No. Input Output 1 Output 2 CN9110A Relay – CN9111A Relay Relay CN9112A Relay Pulse CN9120A Pulse – CN9121A Pulse Relay CN9122A Pulse Pulse CN9131A 1 A SSR Relay CN9141A 4 to 20 mA Relay CN9151A 0 to 10 Vdc Relay CN9210A Relay – CN9211A Relay Relay CN9212A Relay Pulse CN9220A Pulse – CN9221A Pulse Relay CN9222A Pulse Pulse CN9231A 1 A SSR Relay CN9241A 4 to 20 mA Relay CN9251A 0 to 10 Vdc Relay
Accessories and Replacement Output Modules Model No. Description
CN9000-14
CN9000-18 CN9000A-SOCKET Terminal socket BD9011A Dual relay, field installable module BD9021A Pulse/relay, field installable module BD9031A 1 A SSR and relay, field installable module BD9041A 4 to 20 mA and relay, field installable module BD9051A 0 to 10 Vdc and relay field installable module BD9010A Relay output board BD9012A Relay/pulse field installable module BD9022A Dual pulse field installable module DPP-4
Comes complete with operator’s manual.
† For 230 Vac powered boards add suffix “-230V” to model number, no additional charge.
115 Vac models are UL recognized. UL not available for 230 Vac models. For 230 Vac power, add suffix “-230VAC” to model number, no additional charge. For 24 Vac power, add suffix “-24VAC” to model number, no additional charge.
Ordering Examples: CN9121A, autotune controller with thermocouple/2-wire RTD input, pulse output (output 1) and relay output (output 2), with CN9000-14 (
OCW-2 OMEGACARESM extends standard 3-year warranty to a total of 5 years. CN9210A, autotune controller with 3-wire RTD input, relay output (output 1). BD9011A, replacement output board, dual relay module.
T/C,
2-wire
RTD
3-wire
RTD
1
4 DIN mounting adaptor
1
8 DIN mounting adaptor
1
16 DIN panel punch
For Additional
Controllers and
Indicators, visit
omega.com