OLYMPUS mju 410 NOTICE OF MODIFICATION V1R9

µ-30/µ[mju:]410/Stylus410 DIGITAL
E. NOTICE OF MODIFICATION
1. Addition of the finder screw (counterclockwise screw) ................................. E-2
2. Modification of the 199MC-PCA........................................................................ E-3
3. A countermeasure to the non-exposure issue ................................................ E-4
4. Modification of the Front Cover-ASSY ............................................................. E-5
5. Addition of the 199BR Plate S........................................................................... E-6
E-1 Ver.1
Rev.9
E. NOTICE OF MODIFICATION
µ-30/µ[mju:]410/Stylus410 DIGITAL
SUBJECT
Addition of the finder screw (counterclockwise screw)
DESCRIPTION : Finder screw (counterclockwise screw) is added.
Parts No. Parts Name
VE680100 PUTB1635L
REASON :
Finder screw was changed for improvement of the manufacturing process. Along with the change, new finder screw is registered as a service part.
REMARKS :
Take actions below upon repair.
1. Basically, use original screws that are with the camera.
2. If use new Lens-ASSY or BaseFrame-ASSY, use the counterclockwise screw.
May.12.2004
E-2
Rev.3
Ver.1
µ-30/µ[mju:]410/Stylus410 DIGITAL
E. NOTICE OF MODIFICATION
SUBJECT
Modification of the 199MC-PCA
DESCRIPTION : The 199MC-PCA is changed.
OLD NEW
199MC-PCA VJ567500 Æ VJ567501
REASON :
A countermeasure of that a xD picture card may not be recognized.
REMARKS :
Use the new parts for the camera which has the above problem. Use the old parts for other cameras. Only new part are supplied when old parts are out of stock.
Jun.11.2004
Ver.1 Rev.4