Oasis Quasar PWEBQ, Quasar P EBQ, Quasar PWF2EBQ, Quasar PG8EBQ, Quasar PG8F2EBQ Installation Instructions Manual

Water Coolers
QUASAR Hands-Free Bottle Filler
UVC-LED WATER TREATMENT
Model PWEBQ and PWF2EBQ (retro fit) and P*EBQ Family of Drinking
Fountains/Bottle Filler combo
Installation Instructions
The Hands-Free Bottle Filler mounts directly above Versacooler® I and II products. If the cooler electrical outlet does not have two useable plugs, an outlet splitter will need to be used.
If installed onto a refrigerated cooler, chilled water can be dispensed through the Bottle Filler. Otherwise, room temperature water will be dispensed.
The Bottle Filler is shipped partially assembled.
On the combo units, the cooler is plumbed and ready to attach to the Bottle Filler.
When completed, the finished assembly will look like this:
OR
1
Section 1: Getting Started
What’s Included:
Top C ap
Quasar Hands-Free
Bottle Filler
38” of ¼ OD plastic tubing with 19” of sponge tubing insulation (included
with “Quasar Bottle Filler ready” coolers)
Snap bushings 7/8”
and 1½”
Quick connect tee
fitting
Installation instructions
Rubber Gasket
Versafilter II
The Versafilter II and remedi filter are only included in the PWF2EBQ model.
remedi
filter
Tool s required:
Ø 3/8” pilot drill and either a step drill bit up to 7/8” diameter that will drill
through SS top or 7/8” diameter punch die (retrofit version only)
Ø Electric drill; wrench for punch die
Ø Small tubing cutter for copper tube
Ø 1/4“ nut driver
Ø # 2 Phillips screw driver
Ø #15 torx bit driver
2
Section 2: Rough In Drawing
Oasis PWEBQ: Versacooler® II Models PAC, P8AC with Hands-Free Bottle Filler
3
Section 2: Rough In Drawing
Oasis PWEBQ: Versacooler® II Split Level Models with Hands-Free Bottle Filler
* On split level models, the Bottle Filler must be mounted on the
low unit in order to meet ADA guidelines.
4
Section 3A: Installation
Note: Proceed to Section 3B Step 5 “Final steps for both product families” if the cooler is purchased “Quasar Bottle Filler or VersaFiller ready”.
A: Drilling hole in the top for water line connection.
1. Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power.
2. Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve.
3. Place hole template onto cooler top so it is aligned with the left side of unit and wall. SEE NEXT PAGE FOR TEMPLATE
4. Mark hole location
5. Remove top from unit.
Mark hole location.
Template
Remove top from cooler by removing six, #15 torx head screws on sides of top.
6. Using a step drill bit or 7/8” punch die, make a 7/8” hole through top. You may want to drill a pilot hole to get these started.
7. Install snap bushing into hole to protect tubing from being cut.
Install bushing
Drill
5
5
ALIGN THIS EDGE
WITH LEFT EDGE OF
COOLER TOP
Mark this center point on the
top. Remove the top from the
cooler. Then create a 7/8”
diameter hole through the top
at the marked center point
(step drill bit or punch die).
paper
3-1/4”
from
edge of
edge of
paper
AGAINST WALL
2-1/8”
from
PLACE THIS EDGE
USE THIS TEMPLATE TO MARK THE HOLE LOCATION ON COOLER TOP
6
Section 3B: Installation
VersaCooler to Quasar Bottle Filler Plumbing Diagram
OPTIONAL
VERSAFILTER II
INLINE
STRAINER,TUBE,
AND REDUCER FTG.
PROVIDED WITH
FOUNTAIN.
OPTIONAL
FILTER
BOTTLE FILLER
SOLENOID
VALVE
UV LED
BUILDING
INLET WATER
VERSACOOLER
7
Section 3B: Installation
Two VersaCoolers to Quasar Bottle Filler Plumbing Diagram
BOTTLE FILLER
OPTIONAL
VERSAFILTER II
OPTIONAL
FILTER
SOLENOID
VALVE
VERSACOOLER
UV LED
VERSACOOLER
INLINE
STRAINER,TUBE,
AND REDUCER FTG.
PROVIDED WITH
FOUNTAIN.
BUILDING
INLET WATER
T-FITTING
8
Section 3B: Installation
B: Connecting the water line
Note: If you are retrofitting the Bottle Filler to an existing cooler, follow the instructions starting on page 11.
For the single “Bottle Filler ready” cooler, the tube to connect to the Bottle Filler is found inside the access panel (the compressor compartment). This
tube supplies cold water from the cooling tank to the Bottle Filler.
¼” OD tube to connect to Versafiller
For split level “Bottle Filler ready” coolers, the tube to plumb in the Bottle Filler is packaged in the dummy unit.
Remove tube from bag.
First, remove plug from fitting on tank drain
Next, insert end of tube into fitting.
9
Loading...