Connecting the Unit ................................................................................................................................................... 15
Web Management and Configuration ........................................................................................................................ 19
System Info Page ..................................................................................................................................................................... 21
System Information ............................................................................................................................................................ 22
Extra Info ............................................................................................................................................................................ 25
Link Setup Page ...................................................................................................................................................................... 28
NTP Client, Web Server, Telnet Server, SSH Server, System Log .................................................................................... 49
System Config Page ................................................................................................................................................................ 50
Host Name .......................................................................................................................................................................... 51
Interface Language ............................................................................................................................................................. 52
Common Topology Scenarios .................................................................................................................................... 53
The N-Tron 702-W Industrial Ethernet Wireless Device offers outstanding performance and ease of use. It
is ideally suited for connecting wireless devices to a wired network and connecting two wired networks
together where wires are not possible or practical to be installed.
PRODUCT FEATURES
• Full IEEE 802.3 Compliance
• One 10/100 BaseTX RJ-45 Port
• Three Antennas for 3x3 MIMO Operations
• Extended Environmental Specifications
• Autosensing 10/100BaseTX, Duplex, and MDIX
• Offers Spanning Tree Protocol
• Store & Forward Technology
• Rugged Din-Rail Enclosure (Bulk head mount for M12
version, Pole Mount Kit Available)
• Redundant Power Inputs (20-49 VDC)
• Full SNMP
• Web Browsing and N-View Monitoring
• IP65 Rated for protection against low pressure jets of
water from any direction (M12 version)
• IP66 Rated for protection against high pressure jets of
water from any direction (M12 version)
• IP67 Rated for protection against temporary immersion
in water (M12 version)
All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-Tron
Corporation is prohibited, except as allowed under copyright laws.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos
or other designations mentioned herein are trademarks of their respective owners.
The information contained in this document is subject to change without notice. N-Tron Corporation makes
no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of
merchantability or fitness for a particular purpose. In no event shall N-Tron Corporation be liable for any
incidental, special, indirect or consequential damages whatsoever included but not limited to lost profits
arising out of errors or omissions in this manual or the information contained herein.
Warning
A well-trained technician is required to establish a wireless network safely. Do not perform any services on
the unit unless qualified to do so.
Do not substitute unauthorized parts or make unauthorized modifications to the unit.
Do not operate the unit with the top cover removed, as this could create a shock or fire hazard.
Do not block the air vents on the sides or the top of the unit.
Do not operate the equipment in the presence of flammable gasses or fumes. Operating electrical equipment
in such an environment constitutes a definite safety hazard.
Do not operate the equipment in a manner not specified by this manual.
(Revised 2011-12-09) Page 4 of 62
Safety Warnings
GENERAL SAFETY WARNINGS
WARNING: If the equipment is used in a manner not specified by N-Tron Corporation, the protection
provided by the equipment may be impaired.
Contact Information
N-Tron Corporation
3101 International Drive East
Building 6
Mobile, AL 36606
TEL: (251) 342-2164
FAX: (251) 342-6353
WEBSITE: www.n-tron.com
E-MAIL: N-TRON_Support@n-tron.com
ENVIRONMENTAL SAFETY
WARNING: Disconnect the power and allow to cool 5 minutes before touching.
WARNING: Explosion hazard; do not disconnect while circuit is live unless area is known to be nonhazardous.
ELECTRICAL SAFETY
Must be used with listed UL Class 2 Industrial Power Supply
WARNING: Disconnect the power cable before removing the top cover.
WARNING: Do not operate the unit with any cover removed.
WARNING: Properly ground the unit before connecting anything else to the unit. Units not properly
grounded may result in a safety risk and could be hazardous and may void the warranty. See the grounding
technique section of this user manual for proper ways to ground the unit.
WARNING: Do not work on equipment or cables during periods of lightning activity.
WARNING: Do not perform any services on the unit unless qualified to do so.
WARNING: Do not block the air vents.
(Revised 2011-12-09) Page 5 of 62
WARNING: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage
polarity can cause permanent damage to the unit and void the warranty.
WARNING: The human body should be at least 20cm from these wireless devices during operation.
Please make sure the N-Tron Wireless Device package contains the following items:
1. 702-W or 702M12-W Wireless Device
2. Three Antennas
3. Product CD
Contact your carrier if any items are damaged.
Installation
Read the following warning before beginning the installation:
WARNING
Never install or work on electrical equipment or cabling during periods of lightning activity. Never connect
or disconnect power when hazardous gasses are present.
Substitution of components may impair suitability for Division 2.
Always install antennas with adequate lightning and surge protection.
For IEEE 802.11b/g, 2.4GHz antennas are needed. For IEEE 802.11a, 5GHz antennas are needed.
Disconnect the power cable before removing any enclosure panel.
UNPACKING
Remove all the equipment from the packaging, and store the packaging in a safe place. File any damage
claims with the carrier.
CLEANING
Clean only with a damp cloth.
(Revised 2011-12-09) Page 6 of 62
INGRESS PROTECTION IP67
The classification of degrees of protection provided by the enclosures is defined by IEC 60529. Each rating
is defined by specific tests.
The IP number is comprised of two numbers, the first referring to the protection against solid objects and
the second against fluids. The higher the number, the better the device is protected against contact with
moving parts and the harmful entry of various forms of moisture.
1st IP Protection against ingress of solids 2nd IP Protection against ingress of liquids
No protection
0
Protected against solid objects over 50mm e.g. hands,
1
large tools.
Protected against solid objects over 12mm e.g. hands,
2
large tools.
Protected against solid objects over 2.5mm e.g. wire,
3
small tools.
Protected against solid objects over 1.0mm e.g. wires.
4
Limited protection against dust ingress (no harmful
5
deposit)
Totally protected against dust ingress.
6
No protection
0
Protected against vertically falling drops of water.
1
Protected against direct sprays of water up to 15°
2
from vertical.
Protected against direct sprays of water up to 60°
3
from vertical.
Protected against water sprayed from any direction.
4
Limited ingress permitted.
Protected against low pressure water jets from any
5
direction. Limited ingress permitted.
Protected against high pressure water jets from any
6
direction. Limited ingress permitted.
Protected against temporary immersion between
7
15cm to 1m.
Protected against long periods of immersion under
8
pressure.
The 702M12-W Industrial Wireless Device is fully protected against dust and will remain sealed when
immersed in water to a depth of 1 meter for 1 hour when all the ports are properly mated or sealed.
This IP67 cap seals off the LAN ports if unused to protect them from dirt, water, oil or any
other contaminants which might be present in close proximity of the device.
This IP67 cap seals off the Antenna ports if unused to protect them from dirt, water, oil or
any other contaminants which might be present in close proximity of the device.
This IP67 cap seals off the Power port if unused to protect it from dirt, water, oil or any other
contaminants which might be present in close proximity of the device.
(Revised 2011-12-09) Page 7 of 62
702-W DIN RAIL MOUNTING
Install the unit on a standard 35mm Din-Rail. Recess the 702-W unit to allow at least 3” of horizontal
clearance for copper cable bend radius.
DIN-Rail Mounting
To mount the unit to the 35mm DIN-Rail, place
the top edge of the bracket on the back of the
unit against the DIN-Rail's top edge at an upward
angle. Then, rotate the unit downward and back
against the DIN-Rail until it snaps into place.
You may need to adjust the angle of the antennas
19” Universal Rack Mounting
Most N-Tron™ products are designed to be
mounted on industry standard 35mm DIN-Rail.
However, DIN-Rail mounting may not be suitable
for all applications. Our Universal Rack Mount
Kit (P/N: URMK) may be used to mount the 702W to standard 19" racks as an option.
depending on the amount of clearance available.
To remove the vertically mounted unit from
35mm DIN-Rail, carefully apply downward
pressure on the unit. Then, rotate the unit
upward and away from the 35mm DIN-Rail and
lift up for removal.
(Revised 2011-12-09) Page 8 of 62
702M12-W BULKHEAD MOUNTING
The following are the mechanical dimensions and drill hole placements to consider when mounting the
702M12-W Industrial Ethernet Switches:
(Revised 2011-12-09) Page 9 of 62
702M12-W POLE KIT MOUNTING
The 702M12-W can be mounted to a pole with N-Tron’s 702M12 Pole Kit (P/N: 702M12-PK).
Bracket orientation for small (1” [25mm] dia.) pipe
2x Tighten bolts using 7-8 ft-lb of torque
[9.49-10.85 N-m] (all pipe installations)
2x Tighten nuts using 10-11 ft-lb of torque
[13.56-14.91 N-m] (all installations)
4x Tighten 0.250-20 bolts using 10-11 ft-lb of torque
[13.56-14.91 N-m] (all installations)
Bracket orientation for larger (up to 3” [76mm] dia.) pipe
6x Tighten #10-32 screws until split lock
washers fully compress (all installations)
(Revised 2011-12-09) Page 10 of 62
FRONT PANEL
From Top to Bottom (M12 only):
RJ45 Port Auto Sensing 10/100 Base-TX Connections with PoE Support
Power Port
PWR LED lights when Power is supplied to the unit
LEDs: The table below describes the operating modes:
LED Color Description
GREEN Good Signal (user defined)
ORANGE Poor Signal (user defined)
Radio
Enabled
RED Bad Signal (user defined)
GREEN The radio interface is active
OFF The radio interface is off
GREEN LAN Link is present
LNK/ACT
FLASHING Data is active over the ports
OFF No Link is present on the LAN port
GREEN Power is applied
PWR
OFF No Power is applied
(Revised 2011-12-09) Page 11 of 62
APPLYING POWER (702-W Side View)
Unscrew & Remove the DC Voltage Input Plug from the Power Input Header
Install the DC Power Cables into the Plug (observing polarity).
Plug the Voltage Input Plug back into the Power Input Header.
Tightening torque for the terminal block power plug is 0.5 Nm/0.368 Pound Foot.
Verify the Power LED stays ON (GREEN).
Notes:
Only 1 power supply must be connected to power for minimal operation. For redundant power
operation, V1 and V2 inputs must be connected to separate DC Voltage sources. This device will
draw current from both sources simultaneously. Use 16-28 gauge wire when connecting to the
power supply.
The LAN port supports Power over Ethernet and can be used redundantly with the power input
mentioned above.
Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N NTPS-24-1.3:
Input AC 115/230V
Output DC 24-28V
Output Current 1.3A @ 24V
Power 30W
35 mm DIN-Rail Mountable
Dimensions: 45X75X91 mm
1.0A @ 28V
M12 Power Cable Assembly
1. Cut the shielded power cable to the desired / required length. The power cable should be a shielded cable with an outer
jacket diameter of 6 to 8mm in size. The individual wires inside the cable must be between 18-24awg (stranded). The
cable must be UL recognized for use up to 110°C.
2. Using the picture below as a guide, slide the parts together in the order shown.
(Revised 2011-12-09) Page 12 of 62
3. Strip back and tin the five wires (red, black, white, green and drain wire – Note: these colors are just an example, actual
colors may vary). Cut off the water block paper and the flat EMI shield (this looks like aluminum foil). Be sure to keep
the drain wire.
4. Screw the wires into the proper assignment by following the chart below (NOTE: the colors used in this example are just
an example, actual wire colors may vary):
Pin
#
1 Red
Wire
Color
(V1+)
2 Black
(V1-)
3 Green
(V2-)
4 White
(V2+)
5 GND
Drain
5. Screw the header end onto the plastic threaded sleeve (looks like a round pipe).
Wire
6. Push and screw down the pressure screw into the other end of the plastic threaded sleeve (this will compress the rubber
gasket giving you an IP67 seal on the cable’s jacket). Note: in order to make a good seal, the outer cable diameter must
be between 6-8mm and the outer jacket must be waterproof – Some plastic jackets will abso rb water and are not
waterproof.
(Revised 2011-12-09) Page 13 of 62
APPLYING POWER (702M12-W)
The M12 A coded power connector is keyed, where the mating connection from the power supply
can be made only when the male and female ends are lined up properly.
Verify the Power LED stays ON (GREEN).
Notes:
Only 1 power supply must be connected to power for minimal operation. For redundant power
operation, V1 and V2 inputs must be connected to separate DC Voltage sources. This device will
draw current from both sources simultaneously. Use 16-28 gauge wire when connecting to the
power supply.
The LAN port supports Power over Ethernet and can be used redundantly with the power input
mentioned above.
Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N NTPS-24-1.3: (NOTE: Not appropriate
for use with M12, POE, and HV models.)
Input AC 115/230V
Output DC 24-28V
Output Current 1.3A @ 24V
1.0A @ 28V
Power 30W
35 mm DIN-Rail Mountable
Dimensions: 45X75X91 mm
(Revised 2011-12-09) Page 14 of 62
Connecting the Unit
For the 10/100 Base-TX port, plug a Category 5E twisted pair cable into the RJ45 connector. Connect the
other end to the far end station. Verify that the LNK/ACT LED is ON once the connection has been
completed. Use a standard Category 5E straight through or crossover cable with a minimum length of one
meter and a maximum length of 100
meters.
N-Tron recommends the use of premanufactured Cat5E cables to ensure the
best performance. If this is not an option
and users must terminate their own ends
on the Cat5E cables; one of the two color
coded standards shown to the right should
be utilized. If a user does not follow one
of these two color code standards then the
performance and maximum cable distance
will be reduced significantly, and may
prevent the unit from establishing a link.
RJ45 CONNECTOR CRIMP SPECIFICATIONS
Please reference the illustration below for your Cat5 cable specifications:
(Revised 2011-12-09) Page 15 of 62
N-Tron SWITCH GROUNDING TECHNIQUES
The grounding philosophy of any control system is an integral part of the design. N-Tron switches are
designed to be grounded, but the user has been given the flexibility to float the switch when required. The
best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to
earth ground via a drain wire. Some N-Tron switches have metal din-rail brackets that can ground the
switch if the din-rail is grounded. In some cases, N-Tron devices with metal brackets can be supplied with
optional plastic brackets if isolation is required.
Both V- legs of the power input connector are connected
to chassis internally on the PCB. Connecting a drain wire
to earth ground from one of the V- terminal plugs as
shown here will ground the switch and the chassis. The
power leads from the power source should be limited to 3
meters or less in length.
Alternatively, users can run a drain wire & lug from any of the
Din-Rail screws or empty PEM nuts on the enclosure. When
using an unused PEM nut to connect a ground lug via a machine
screw, care should be taken to limit the penetration of the outer
skin by less than 1/4 in. Failure to do so may cause irreversible
damage to the internal components of the switch.
Note: Before applying power to the grounded switch, you must
use a volt meter to verify there is no voltage difference between
the power supply’s negative output terminal and the device
chassis grounding point.
If the use of shielded cables is required, it is generally recommended to only connect the shield at one end to
prevent ground loops and interfere with low level signals (i.e. thermocouples, RTD, etc.). Cat5e cables
manufactured to EIA-568A or 568B specifications are required for use with N-Tron devices.
In the event all Cat5e patch cable distances are small (i.e. All Ethernet devices are located the same local
cabinet and/or referenced to the same earth ground), it is permissible to use fully shielded cables terminated
to chassis ground at both ends in systems void of low level analog signals.
Drain wire with lug connecting switch chassis to known grounding point.
(Revised 2011-12-09) Page 16 of 62
TROUBLESHOOTING
1. Make sure the PWR (Power LED) is ON.
2. Make sure you are supplying sufficient current for the version chosen. Note: The Inrush
current will exceed the steady state current by ~ 2X.
3. Verify that Link LED is ON for the connected port.
4. Verify cabling used between stations.
5. Verify that cabling is Category 5E or greater for 100Mbit operation.
This product complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
ANTENNA STATEMENT
The regulatory domain this equipment is installed in has a legal limit for the equivalent isotropic radiated
power (EIRP) that is determined by the output power and the antenna gain. It is the installer’s responsibility
to make sure this rule is not violated. All equipment should be professionally installed. After proper
installation the device should be properly protected to ensure regulatory compliance.
FCC sets the maximum gain for the following antenna types for the 702-W Radios;
2.4GHz Omni-Directional 5dBi
2.4GHz Panel Directional 17dBi
5.8GHz Panel Directional 21dBi
5.8GHz Parabolic Dish 32dBi
NOTE: External Antennas should be installed and operated with a minimum distance between the radiator
and any person or operator. This distance is determined by the regulatory domain the equipment is installed
in and should be calculated by the installer at the time of installation to ensure regulatory compliance and the
safety of operators around the radiator.
(Revised 2011-12-09) Page 17 of 62
INDUSTRY CANADA
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment
Regulations (ICES-003). Operation is subject to the following two conditions; (1) this device digital
apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions; (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne
causant des règlements d'équipement (NMB-003). L'opération est sujette aux deux conditions suivantes:
(1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe
quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.
(Revised 2011-12-09) Page 18 of 62
Web Management and Configuration
Enter the device’s IP address in any web browser and login to the web management feature of the 702-W.
Default:
IP Address: 192.168.1.202
User Name: admin
Password: admin