GarageDoorRail
MagneticSensor(Contacts1&6))
VerticalRail
MagneticSensor(Contacts5&7)
HorizontalRail

MagneticSensor(
Contacts5&7)
MagneticSensor(
Contacts1&6))

GARAGEDOORMONITOR
SAFETYSENSORS
INTRUSIONALERT
PAGERALERTSYSTEM
OurGarageDoorMonitorwillnotifyyou
withavoicewarning,messageontheLCD
displayandpageralert(ifproperly
installed).
GarageDoorVoiceWarnings
!
!
!
!
”GarageDoorAjar”willannouncein
theControlPanelbaseduponyour
pre-selectedtimersetting(0-1440
minutes(24hours))
”GarageDoorOpening“will
announceintheControlPanel
instantlywhenyourGarageDoor
startstoopen
”GarageDoorClosing”will
announceintheControlPanel
instantlywhenyourGarageDoorhas
fullyclosedotherwisethetimerwill
stillbeactive
”GarageDoorClosingPleaseStand
Clear“willannounceinthe
GARAGEUNITinstantlyupon
downwardmovementoftheGarage
Door
INTELLI-SENTRYDPSSafety
Sensorswhenactivatedwillsenda
wirelesssignaltotheControlPanel.
SafetySensors
CODetector
HeatDetector
Smoke/FireDetector
4-WayAlert
Voice,TextonLCD,Sirenfrom
SensorandPagerAlert
GARAGEAREA
Limitedto:
1HeatDetector
2.CODetector(When
Available)
INSIDEOFHOME
Canhaveanunlimitednumberof
smoke,heatorCOdetectorswhen
combinedwithourverypractical
REMOTEDETECTOR
TRANSMITTER
1ormoreHeatDetectors
1ormoreSmokeDetectors
1ormoreCODetectors
AnicebackuptotheGarageDoorMonitoris
the“INTRUSIONALERT”Feature.Simply
attachthemotionsensortotheGarageUnit
andinstallintheGaragealignedtodetect
movementfromanyspacewhileenteringthe
GarageSpace.
VoiceWarning
:”IntrusionAlertintheGarage
“IntrusionAlertintheControlPanelinthe
House
Settings
!
!
!
IntrusionAlertMotionSensor
activates2.5minutesaftertheGarage
DoorOpens
Temporaryshut-offswitchonthe
GarageUnitifyouknowyou’llbein
theGarageArea.Thesystemwill
auto-resetwhendoorisfullyclosed
andre-opened
!
Receiveapagetoyourpageror
qualifyingcellulartelephonewitha
messageindicatingtheparticularalert.
!
!
!
!
!
Programthetelephonenumberto
bedialed
Connectastandardtelephone
linetotheControlPanel
Setthetypeofalert
!
!
!
!
VacationAlert
GarageDooropensaninstant
PagerAlertwillbe
sent((”811”PagerCode)
WorkAlert
sentiftheGarageDoorhas
beenopenfor45minutesor
longer(”811”PagerCode)
SafetyAlerts
instantpagetoapagerifanyof
thefollowingsensorsare
activated.Pleasetestmonthly
COSensors(”911”Pager
Code)
SmokeSensors(”911”Pager
Code)
TemperatureAlerts
snow-birds.TheC ontrolPanel
willsendaninstantpage(”711”
PagerCode)ifthetemperaturein
thehousefallsbelow50degrees
Fahrenheit.
PIPES!!!
NOFROZEN
-Whenthe
-Pagewillbe
-willsendan
-Greatfor
SafetySensorVoiceWarning
“DangerCODetectedHighinHouse”
(withtheRemoteDetector
Transmitter)etc.

DigitalFamily
MessageCenter
Younolongerhavetofindapenciland
papertowritedownaquicknotetoanother
inyourhousehold.LEAVEIT
DIGITALLY!!!
!
!
RecordMessagesupto20seconds
on3mailboxes.That’supto60
secondsofdigitalaudiocombined.
Designateamailboxforapersonor
eventforexample
!
!
!
Mailbox1=SpousetoSpouse
Mailbox2=ParentstoChildren
orChildrentoParents
Mailbox3=Emergencies
TricksfortheDigital
FamilyMessageCenter
Whilerecordingamessage,tostop
!
therecordingbeforeitautomatically
stops,holdthePLAYbuttonfor4
seconds.Recordingwillcease.
Whileplayingbackamessage,to
!
stopthemessagebeforeit
automaticallyresets, holdtheREC
buttonfor4seconds.Playwillstop
TEMPERATURE
READINGS&CHIMES
OntheControlPanelthereare4
!
temperaturereadings.Current
Indoor(upperright),currentoutdoor
(lowerleft),24hourrecordhigh
temperaturelowermiddleand24
hourrecordlowtemperature(lower
right)
3SetsofHourlyChimesandOFF
!
(NOCHIMES)
INSTRUCTIONS
ToInstallINTELLI-SENTRYDPSisaseasyas
1-2-3.
CONTROLPANEL
INSTALLATION
Step1
Carefullyremovecomponentsfromthe
packagingandensureallcomponentsareinthe
package
Step2
PlugtheControlPanelintoawallsocketand
beginprogramming.(SeeProgramming/Mode
Settings)
Step3
MounttheControlPanelonaconvenientwall
andmeasure5-13/16”(14.7cmor147mm)and
spacethemountingscrewsaccordinglyorplace
theControlPanelonadesk/countertop
Step4
Plugastandardmodulartelephoneplugintothe
bottomofthecontrolpaneltoenablethePager
AlertSystem.ControlPanelisfullyinstalled!!!
GARAGEUNIT
INSTALLATION
Step1
Attachthesensorstotheterminal block
accordingtothediagramprovided.
Step2
Installthesensorsintheproperpositioninthe
Garage(Magnetic,Motion,COorHeat/Smoke,
Shut-offSwitchorHouse(SafetySensors)
Step3
MounttheGarageUnitonaconvenientwalland
measure4-15/16”(12.5cmor125mm).Plugthe
GarageUnitintoanelectricaloutlet
INSTRUCTIONS
CONTINUED
REMOTEDETECTOR
TRANSMITTER
INSTALLATION
Step1
Install4AAAlkalineBatteries(notincluded)
intothetransmitterboxandinstallthe
supplied9Vbatteryintothesafetydetectors
(CO,SMOKEorHEAT).Mountthebaseof
thedetectorstotheceilingorwall.
Step2
Attachthecablefromtheremotedetector
transmittertothebottomsideofthesafety
detectors.Keepinmindthatonecableisfor
theCO&oneforthesmoke/heatdetectors.If
thewrongmessageisplayedwheninstalled,
PLEASESWITCHTHEDETECTORSTO
THEOTHERCABLE.
Step3
MounttheRemoteDetectorTransmitterona
convenientwallorceilingandmeasure4”
(10.2cmor102mm).
SETTINGSSCREENS
MainLCDDisplay&
Settings
Miscellaneous
12:02AM75F
52$53/52F
UpDownChanges
12:09A
SetTime?
PressMODE/SET
SETForC?
PressMODE/SET
GARAGEDOORSETTINGS
UpDownChanges
0003
PAGERALERTSETTINGS
UpDownChanges
1-555-555-5555
AlertType
Vacation
SetAlertType
PressMODE/SET
OTHERMISCELLANEOUS
SETTINGS
UpDownChanges
IIIIIIIIIIIIIIIIIIIIIIIIIIII
SetChime?
PressMODE/SET

PROGRAMMING
INTELLI-SENTRYDPS
Itcouldnotbeeasier.Themainscreenisthe
screenwhentheGarageDoorisfullyclosed
whichshowsthe
1.CurrentIndoorTemperature-UpperRight
2.CurrentOutdoorTemperature-LowerLeft
3.24HrRecordHighTemperature-Lower
Middle
4.24HrRecordLowTemperature-Lower
Right
PROGRAMMING
BUTTONOPERATIONS
ToTogglebetweenModes
INTELLI-SENTRYDPS
PART15STATEMENT
THISDEVICECOMPLIESWITHPART15OFTHE
FCCRULES.OPERATIONISSUBJECTTOTHE
FOLLOWINGTWOCONDITIONS:(1)THIS
DEVICEMAYNOTCAUSEHARMFUL
INTERFERENCE,AND(2)THISDEVICEMUST
ACCEPTANYINTERFERENCERECEIVED
INCLUDINGINTERFERENCETHATMAYCAUSE
UNDESIREDOPERATION.
GM-300-433SENTRY
INTELLI-
SENTRYDPS
DoorPositioningSystem
OperationsGuide
&Installation
Instructions
Continuetopresstheuparrow
ToChangeaSetting
Movethecursorandusetheup&downarrowto
increaseordecreaseaparticularvalue
ToActivateaSetting
AfterinputtingthevalueorselectionACTIVATEBYPRESSINGMODE
ANDTHAT’SIT!!!AREN’TYOU
GLAD!!!
CHANGESORMODIFICATIONSNOT
EXPRESSLYAPPROVEDBYTHEPARTY
RESPONSIBLEFORCOMPLIANCECOULD
VOIDTHEUSER’SAUTHORITYTOOPERATETHE
EQUIPMENT.
NOVATIONPRODUCTS,INC.
GarfieldHeights,Ohio44137
www.novationproducts.com
customerservice@novationproducts.com