Noritz NRC111-SV User Manual

Model NRC111 Series
Residential Condensing Tankless Water Heater
Specification Sheet
- gas consumption ranges from 11,000 BTUh to
199,900 BTUh
- flow rates from 0.5 gpm up to 11.1 gpm
- ANSI Z21.10.3/CSA 4.3 certified design that can be wall-mounted indoors or installed outdoors with an -SV model using the optional Vent Cap
- manufactured with commercial grade copper,
25% thicker piping than standard models
- two identical units can be linked together by using
the optional Quick Connect Cord for twice the hot water capacity
- 0.91 (NG) 0.93 (LP) for SV model
0.92 (NG) 0.94 (LP) for DV model
- fully condensing, 93% efficient for use with natural
gas or propane
- includes remote thermostat that can precisely
adjust the output temperature from 100°F to 180°F
- 6’ power cord is included with -SV and
-DV models (assembly required for SV models)
- Flame Sensor, Overheat Prevention Device,
Lightning Protection Device, Freeze Protection, Neutralizer Overfill
Temperature Lockout, High Elevation Adjustment,
Condensate Neutralizer with Monitoring System
- CSA, UPC**, NSF, Low NOx Approved By SCAQMD (Rule 1146.2),
Suitable for Installation in a Manufactured (Mobile) Home***
LOW-LEAD
SV Model
This model is eligible for the Federal tax credit of up to 10% of the water heater and installation costs (up to $300) when installed in a residence between 1/1/2011 through 12/31/2011
NRC111 - _____
SV (Standard Vent)
DV (Direct Vent)
Birdscreen for 3” PVC/CPVC (#VP3-PVCS)
Birdscreen for 4” PVC/CPVC (#VP4-PVCS)
Outdoor Vent Cap for Condensing -SV Model (#VC-4C)
Isolator Valves (#IK-WV-7)
Pipe Cover (#PC-3S)
Quick Connect Cord (#QC-1)
DV Model
CERTIFIED
R
* Heat Exchanger warranty is maintained at 12 years or 6500 operational hours, whichever occurs first, when used in a single family dwelling in conjunction with a controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited Warranty for complete coverage details ** This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking Water Act *** Manufactured (Mobile) Home approval is valid for OD and DV models only
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
1.6"
0.4"
3.7"
5.1"
9.4"
1.1"
FLUE COLLAR
Dimensions
18.3"
17.6"
5.1"
LED
AIR INLET
5.1"
18.3"
17.6"
9.1"5.9"
5.1"
FLUE COLLAR
23.1"
0.4"
SIDE VIEW
Temperature Rise (°F)
Flow Rate (GPM)
24.2"
AIR INLET
AIR INLET
FRONT VIEW
WIRING THOROUGHWAY
CONDENSATE DRAIN
WATER DRAIN VALVE
HOT WATER OUTLET
WATER DRAIN VALVE
COLD WATER INLET
BOTTOM VIEW
WATER DRAIN VALVE
(WATER FILTER)
WIRING THOROUGHWAY
GAS INLET
WATER DRAIN VALVE
WIRING THOROUGHWAY
(AC120V)
DV Model
HEIGHT OF EACH FITTING FROM BOTTOM OF CASE
CONDENSATE DRAIN
HOT WATER OUTLET
COLD WATER INLET
Flow Rates
30 40 45 50 60 70 80 90 100
11.1 9.3 8.4 7.4 6.2 5.3 4.6 4.1 3.7
Pressure Loss
30
LED
NRC111 Series
0.9"
1.7"
2.2"
2.2"GAS INLET
25
20
15
10
Pressure Loss (psi)
5
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0
Set temp erature: 125°F or higher
Set temp erature: 120°F or less
Flow Rate (gpm)
60
50
40
30
20
10
0
Ft of Head
Specifications
Model Name
Weight
Water Holding Capacity
Connection Sizes
Power
Consumption NG: 106W LP: 109W Freez e Prevention 213W
Freez e Prevention
*181.4°F actual output temperature
Indoor: -30
NRC111-SV
°F Outdoor: -4°F
NRC111-DV
74 (pounds)
0.5 Gallon
"4/3telnI retaW
"4/3teltuO retaW toH
"4/3telnI saG
serepma 4 naht ssel ,)zH06( CAV021ylppuS
NG: 115W LP: 120W Fr eeze Pre vention 213W
Indoor: -30
)snoitpO 41( F°081* ,F°071 ,F°061 ,)slavretni F°5 nI( F°051-001sgnitteS erutarepmeT
)F°021 si tluafeD( F°081* ,041 ,031 ,021snoitpO erutarepmeT tluafeD
°F
ut notice.
Rev. 11/13