Noritz NRC111-DV User Manual

Residential Condensing Tankless Water Heater
Specification Sheet
- Gas consumption ranges from 16,000 BTUh to
199,900 BTUh
- Flow rates from 0.5 gpm up to 11.1 gpm
- ANSI Z21.10.3/CSA 4.3 certified design that can be
wall-mounted indoors or outdoors
- Manufactured with commercial grade copper,
25% thicker piping than standard models
- Available as an Outdoor (requires no venting) or indoor Direct Vent (-DV) model which includes special plastic flue adapters that are compatible with both 3” or 4” Schedule 40 and 80 PVC/CPVC pipe. The DV model can also be converted to an SV model with the use of a Conversion Kit (#SV-CK-3)
- Two identical units can be linked together by using
the optional Quick Connect Cord (#QC-2) for twice the hot water capacity
- 0.91 (NG) 0.91 (LP) for DV model
0.93 (NG) 0.93 (LP) for OD model
- Includes remote thermostat that can precisely adjust the output temperature from 100°F to 140°F with the capability to display temperatures in both °C and °F
- 6’ power cord is included with -DV models only
- Flame Sensor, Overheat Prevention Device,
Lightning Protection Device, Freeze Protection, Condensate Overfill
Temperature Lockout, High Elevation Adjustment,
Condensate Overflow Monitoring System, Service Reminder Function
- CSA, UPC**, NSF, Low NOx Approved by SCAQMD [<14ng/J or 20ppm]
OD Model
NRC111____
OD (Outdoor Vent)
DV (Direct Vent)
Horizontal Hood Termination (#PVT-HL)
3” PVC Termination (#VK3-H-PVC)
Birdscreen for 3” PVC/CPVC (#VT3-PVCS)
Birdscreen for 4” PVC/CPVC (#VT4-PVCS)
Condensate Neutralizer (#NC-1)
Isolation Valves (#IK-WV-200-1-(SW / TH)-LF)
Pipe Cover (#PC-3S)
Quick Connect Cord (#QC-2)
SV Conversion Kit (#SV-CK-3)
DV Model
LOW-LEAD
CERTIFIED
R
* Heat Exchanger warranty is maintained at 12 years or 6500 operational hours, whichever occurs first, when used in a single family dwelling in conjunction with a controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited Warranty for complete coverage details ** This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking Water Act
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
Dimensions
0.4" (10mm)
1.6" (40mm)
2.4" (61mm)
23.1" (586mm)
0.4" (10mm)
Side View
9.4" (240mm)
5.5" (140mm)
1.1" (28mm)
WIRING THOROUGHWAY
Ø4.5" (Ø114mm)
Ø3.5" (Ø89mm)
AIR INLET
CONDENSATE DRAIN
WATER DRAIN VALVE
WATER DRAIN VALVE (WATER FILTER)
HOT WATER OUTLET WATER DRAIN VALVE
Temperature Rise (°F)
Flow Rate (GPM)
18.3" (464mm)
17.6" (448mm)
5.9" (150mm) 9.1" (232mm) Ø4.5" (Ø114mm)
Ø3.5" (Ø89mm)
FLUE COLLAR
18.3" (464mm)
17.6" (448mm)
10.5" (267mm)
3.9" (99mm)
2.4" (61mm)2.1" (53mm)
24.2" (615mm)
Front View
BOTTOM VIEW
(AC120V) GAS INLET
COLD WATER INLET
HEIGHT OF EACH FITTING FROM BOTTOM OF CASE
CONDENSATE DRAIN
HOT WATER OUTLET
COLD WATER INLET
OD Model
NRC1111-OD
0.8" (20 mm)
1.7" (44 mm)
2.2" (55 mm)
2.2" (56 mm)
< inch (mm)>
NRC1111-DV
0.8" (20 mm)
1.7" (44 mm)
2.2" (55 mm)
2.2" (56 mm)GAS INLET
Flow Rates
30 40 45 50 60 70 80 90 100
11.1 9.3 8.4 7.4 6.2 5.3 4.6 4.1 3.7
3.9" (99mm)
2.8" (70mm)
6.1" (155mm)
HOT WATER OUTLET (3/4")
CONDENSATE DRAIN (1/2")
HOT WATER OUTLET (3/4")
CONDENSATE DRAIN (1/2")
WIRING THROUGHWAYS
4.3" (109mm)
WIRING THROUGHWAY
3.9" (99mm)
2.8" (70mm)
6.1" (155mm)
4.3" (109mm)
8.4" (214mm)
2.4" (60mm)
DV Model
10.0" (255mm)
8.4" (214mm)
2.4" (60mm)
OD Model
(VIEW FROM TOP)
3.9" (98mm)
5.7" (146mm)
14.2" (362mm)
3.9" (98mm)
5.7" (146mm)
14.2" (362mm)
5.3" (135mm)
7.0" (177mm)
6.7" (171mm)
GAS INLET (3/4")
COLD WATER INLET (3/4")
WIRING THROUGHWAY (AC120V)
WIRING THROUGHWAY (AC120V)
2.8" (71mm)
6.7" (171mm)
7.0" (177mm)
5.3" (135mm)
GAS INLET (3/4")
COLD WATER INLET (3/4")
Pressure Loss
30
25
20
15
10
Pressure Loss (psi)
Bypass Flow Control Valve Close Set temperature : 125ºF or higher (Storage Tank Setting W/ System Controller : 170-185ºF)
Bypass Flow Control Valve Open Set temperature : 120ºF or less (Storage Tank Setting W/ System Controller : 160ºF or less)
5
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 Flow Rate (GPM)
60
50
40
30
20
Pressure Loss (Ft. of head)
10
0
Specifications
Model Name
Weight
Operating Pressure
Gas Supply Pressure
Water Holding Capacity
Water Inlet
Connection Sizes
Hot Water Outlet
Gas Inlet
Condensate Drain
Power
Supply
Freeze Protection
Temperature Settings
Default Temperature Options
NRC111OD (GQ-C3257WX US)
NG: 78W LP: 80W Freeze Prevention 223W
°F Mode
°C Mode
°F Mode
°C Mode
NRC111DV (GQ-C3257WX-FF US)
66 (pounds)
68 (pounds)
15 - 150 psi
NG: 4.0” - 10.5” LP: 8.0” - 14.0”
0.5 Gallon (2 L)
3/4"
3/4"
3/4"
1/2" Threaded
120VAC (60Hz), less than 4 amperes
NG: 81W LP: 83W Freeze Prevention 223WConsumption
Outdoor: -4
°F
Indoor: -30
100-140°F (In 5°F intervals) (9 Options)
37-48°C (In 1°C intervals), 50, 55, 60°C (In 5°C intervals) (15 Options)
120, 135, 140°F (Default is 120°F)
50, 57, 60°C (Default is 50°C)
°F
ut notice.
Rev. 04/16