Model NR981 Series
Residential Tankless Water Heater
Specification Sheet
- gas consumption ranges from 16,000 BTUh to
199,900 BTUh
- flow rates from 0.5 gpm up to 9.8 gpm
- ANSI Z21.10.3/CSA 4.3 certified design that can
be wall-mounted indoors (-SV and -DVC models only) or installed
outdoors with an -OD model
- manufactured with commercial grade copper,
25% thicker piping than standard models
- available in Power Vent (-SV), Outdoor (-OD),
or Concentric Direct Vent (-DVC) model that requires either 4”
Category III or 5“/3” Noritz concentric stainless steel pipe
- two identical units can be linked together by using
the optional Quick Connect Cord (#QC-2) for twice the hot water capacity
- 0.82 (NG) 0.88 (LP) for all NR981 Series models
- 84% efficient for use with natural gas or propane
- includes remote thermostat that can precisely
adjust the output temperature from 100°F to 140°F with the capability to
display temperatures in both °C and °F
- 6’ power cord is included with -SV and
-DVC models (assembly required for SV models)
- Flame Sensor, Overheat Prevention Device,
Lightning Protection Device, Freeze Protection
Temperature Lockout, High Elevation Adjustment,
Service Reminder Function
- CSA, UPC**, NSF, Low NOx Approved by SCAQMD [<14ng/J or 20ppm],
SV Model OD Model
NR981 - _____
SV (Standard Vent)
OD (Outdoor Vent)
DVC (Concentric Direct Vent)
Isolation Valves (#IK-WV-200-1)
Pipe Cover for SV/OD Model (#PC-2S)
Pipe Cover for DVC Model (#PC-5S)
Recess Box for OD Model (#RB-700-1)
Quick Connect Cord (#QC-2)
DVC Model
LOW-LEAD
CERTIFIED
R
* Heat Exchanger warranty is maintained at 12 years or 6500 operational hours, whichever occurs first, when used in a single family dwelling in conjunction with a
controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited
Warranty for complete coverage details
** This product complies with California AB 1953 Low Lead Law and Section 1417(d) of the Safe Drinking Water Act
NORITZ AMERICA CORPORATION
11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com
Dimensions
0.4"
1.6"
22.3"
0.4" - 1.8"
3.7"
2.8"
0.4"
SIDE VIEW
11.1"
4.8"
DVC Model
9.4"
1.1"
1.1"
AIR INLET
WIRING THROUGHWAY
WATER DRAIN VALVE
(WATER FILTER)
HOT WATER OUTLET
WATER DRAIN VALVE
Temperature
Rise (°F)
Flow Rate
(GPM)
13.8"
13.1"
4"
FLUE COLLAR
FLUE COLLAR
13.8"
13.1"
9.9"
2.4"
1.7” 3.4"
23.6"
13.8"
OD Model
5.0"
3.1"
13.1"
FLUE COLLAR
AIR INLET
AIR INLET
FRONT VIEW
BOTTOM VIEW
WIRING THROUGHWAY
(120VAC)
GAS INLET
COLD WATER INLET
HEIGHT OF EACH FITTING
FROM BOTTOM OF CASE
DVC Model
NR981 Series
1.8"HOT WATER OUTLET
2.2"COLD WATER INLET
2.2"GAS INLET
Flow Rates
30 40 45 50 60 70 80 90 100
9.8 8.4 7.5 6.7 5.6 4.8 4.2 3.7 3.4
2.4" (60mm)
1.4" (36mm)
7.2" (184mm)
6.4" (163mm)
HOT WATER OUTLET (3/4")
WIRING THROUGHWAY
5.7" (146mm)
2.4" (60mm)
1.4" (36mm)
6.1" (155mm)
5.3" (134mm)
HOT WATER OUTLET (3/4")
WIRING THROUGHWAY
5.7" (146mm)
(VIEW FROM TOP)
9.5" (241mm)
3.1" (79mm)
WIRING THROUGHWAY
10.3" (262mm)
(AC120V)
DVC Model
9.5" (241mm)
2.0" (50mm)
10.3" (262mm)
WIRING THROUGHWAY
SV and OD Models
7.8" (199mm)
4.9" (125mm)
COLD WATER INLET (3/4”)
GAS INLET (3/4")
6.7" (171mm)
3.8" (97mm)
COLD WATER INLET (3/4")
GAS INLET (3/4")
(AC120V)
Model Name
Weight
Operating Pressure
Gas Supply Pressure
Water Holding Capacity
Connection
Sizes
Power
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Freeze Protection
Temperature Settings
Default Temperature Options
°F Mode
°C Mode
°F Mode
°C Mode
30
25
20
Set temperature:
125°F or higher
Pressure Loss
Set temperature:
120°F or less
15
10
Pressure Loss (psi)
5
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0
Flow Rate (gpm)
Specifications
NR981-SV
54 (pounds)
0.5 Gallon (1.8 L)
NG: 65W LP: 69W Freeze Prevention 193W
Indoor: -30
°F
37-48°C (In 1°C intervals), 50, 55, 60°C (In 5°C intervals) (15 Options)
NG: 4.0” - 10.5” LP: 8.0” - 14.0”
120VAC (60Hz), less than 2 amperes
NG: 65W LP: 67W Freeze Prevention 161WConsumption
100-140 °F (In 5°F inter vals) (9 Options)
120, 135, 140°F (Default is 120°F)
NR981-OD
15 - 150 psi
3/4"
3/4"
3/4"
Outdoor: -4
°F
50, 57, 60°C (Default is 50°C)
60
50
40
30
Ft of Head
20
10
0
NR981-DVC
58 (pounds)
0.2 Gallon (1.0 L)
NG: 80W LP: 83W Free ze Preventi on 193W
Indoor: -30
°F
ut notice.