Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER indicates an imminently hazardous situation which,
DANGER
if not avoided, will result in death or serious injury.
WARNING
CAUTION
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Prohibited
Disconnect
Power
Ground
Be sure to do
CAUTION
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the
installation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
•
Check that the installation was done properly in accordance with this Installation Manual upon completion.
•
After completing installation, please either place this Installation Manual in a plastic pouch and
attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),
or hand it to the customer to retain for future reference. Also, be sure to fill in all of the required
items on the warranty and to hand the warranty to the customer along with the Owner's Guide.
SBA8369
Rev. 09/09
CERTIFIED
R
Low NOx
Approved by
SCAQMD
Accepted For Use
City of New York
Department of Buildings
MEA 19-03-E
FOR USE IN RESIDENTIAL, COMMERCIAL, OR MANUFACTURED HOME APPLICATIONS.
Installation must conform with local codes, or in the absence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54- latest edition and/or CSA
B149.1, Natural Gas and Propane Installation Code (NSCNGPIC).
When applicable, installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the Canadian Standard
CAN/CSA-Z240 MH Mobile Homes, Series M86.
Noritz America reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without notice.
*ENERGY STAR® applies when used in a combination potable
water heating and space heating system.
1.
Included Accessories
The following accessories are included with the unit.
Check for any missing items before starting installation.
PartShapeQ’ty
Tapping Screw
Remote Controller
(See p. 25)
2.
Optional Accessories
Flue Terminal
VT4-TL
Flue Terminal
VT4-TS
5
1
1
1
Owner's Guide, Warranty,
Installation Manual
(this document)
Remote Controller
Cord (10ft)
The accessories listed below are not
included with the units, but may be necessary
for installation.
Quick Connect
Cord
Remote Controller
Cord (26 ft)
Q’tyShapePart
1
each
1
Q’tyShapePartPartShapeQ’ty
1
1
Wall Adapter
for VT4-TS
4" PVC Adapter
VP4-ADAPT-PVC
3" PVC Adapter
VP4x3-ADAPT-PVC
Isolation Valves
(includes pressure
relief valve)
Pipe Cover
(PC-3S-SUS)
1
2
2
1
1
3" PVC Terminal
VK3-H-PVC
Bird Screen for 4" PVC
VT4-PVCS
Bird Screen for 3" PVC
VT3-PVCS
System Controller
1
2
2
1
2
3.
Quick Connect Multi System Installation
• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick
Connect Cord.
The Quick Connect Cord is 6 ft. long. Install the units 6-18" apart from each other to ensure the
cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).
System Diagram
Quick Connect
Cord
Cord
Connector
Typical Plumbing
Cord
Connector
Terminal Block
Remote Controller
Remote Controller Cord
G
Distance at center: 24.3 - 36.3 in.
Distance on sides
6 - 18 in.
Gas Supply Piping
Cold Water Supply
* When connecting two units, use only a
single remote controller.
Note: Connect the remote
controller to only one
of the units.
Hot Water
Union
Union
Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.
Quick Connect
Cord
Shutoff
Valve
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
Union
Gas Valve
Shutoff Valve
Shutoff
Valve
Hot Water
Cold Water
Size the piping to allow for the maximum
flow rates of the units.
• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the cold
water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold
temperatures.
3
Before Installation
4.
DANGER
Checkup
• Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
WARNING
Precautions on Vent Pipe Replacement
• Only use vent materials that are specified in this Installation Manual for use on this appliance. Refer
to the "Vent Pipe Installation" section for details. If PVC, CPVC, or Category IV listed pipe is already
installed, check for punctures, cracks, or blockages and consult with the vent pipe manufacturer
before reusing.
Improper venting may result in fires, property damage or exposure to Carbon Monoxide.
Snow Precaution
• If this product will be installed in an area where snow is known to accumulate, protect the vent
termination from blockage by snow drifts or damage from snow falling off of roofs.
Check the Gas
• Check that the rating plate indicates the
correct type of gas.
• Check that the gas supply line is sized for
199,900 Btuh for this unit.
Check the Power
• The power supply required is 120VAC, at 60Hz.
Using the incorrect voltage may result in fire or electric shock.
.NCC199-DV
10.3a-2007
199,900 BTU
11,000 BTU
4.3a-2007
199,900
222
0.753.35
15
840
4.0
10.5
150
4
192,700
Use Extreme Caution if Using With a Solar Pre-Heater
• Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
CAUTION
Do Not Use Equipment for Purposes Other Than Those Specified
• Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
• If the water supply is in excess of 12 grains per gallon (200 mg/L) of hardness, acidic or otherwise
impure, treat the water with approved methods in order to ensure full warranty coverage.
4
Choosing Installation Site
5.
* Locate the appliance in an area where leakage from the unit or connections will not result in damage
to the area adjacent to the appliance or to the lower floors of the structure. When such locations
cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed
under the appliance. The pan must not restrict combustion air flow.
DANGER
• Locate the vent terminal so that there are no obstacles around the termination and so that exhaust can't accumulate. Do not enclose the termination with corrugated metal or other materials.
WARNING
• Avoid places where fires are common, such as those where gasoline,
benzene and adhesives are handled, or places in which corrosive gases
(ammonia, chlorine, sulfur, ethylene compounds, acids) are present.
Using the incorrect voltage may result in fire or cracking.
• Avoid installation in places where dust or debris will accumulate.
Dust may block the air-supply opening, causing the performance of the
device fan to drop and incomplete combustion to occur as a result.
Prohibited
• Avoid installation in places where special chemical agents
(e.g., hair spray or spray detergent) are used.
Ignition failures and malfunction may occur as a result.
• Carbon Monoxide Poisoning Hazard. Do not install this water heater in a
recreational vehicle or on a boat.
CAUTION
• The water heater is designed for indoor installation only. Never install it
outdoors or in a bathroom, it may be damaged or a fire may be caused.
• Consult with the customer concerning the location of installation.
• Install the water heater in an area that allows for the proper clearances
to combustible and noncombustible construction. Consult the rating
plate on the appliance for proper clearances.
• Do not install the water heater in a place where it may be threatened by
falling objects, such as under shelves.
• The water heater must be installed in a place where supply and exhaust
pipes can be installed as directed.
• Do not install the water heater where the exhaust will blow on outer
walls or material not resistant to heat. Also consider the surrounding
trees and animals.
The heat and moisture from the water heater may cause discoloration of
walls and resinous materials, or corrosion of aluminum materials.
Prohibited
5
CAUTION
• Avoid installation above gas ranges or stoves.
• Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam are present in the installation
location, take measures to prevent the fumes and steam from
entering in the equipment.
• Install in a location where the exhaust gas flow will not be
affected by fans or range hoods.
• Take care that noise and exhaust gas will not affect neighbors.
Avoid installation on common walls as the unit will make some
operational noises while it is use.
• Before installing, make sure that the exhaust flue termination will
have the proper clearances according to the National Fuel Gas
Code (ANSI Z223.1).
Prohibited
Be sure to do
Prohibited
State of California: The water heater must be braced, anchored or strapped to avoid moving during an
earthquake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and request
instructions.
The Commonwealth of Massachusetts: The water heater can be used for hot water only and not in a
combination of domestic and space heating.
For Venting Manufacturers Requirements, see websites or phone numbers listed below:
Noritz N-Ventwww.noritz.com
6
6. Installation Clearances
WARNING
Before installing, check for the following:
Install in accordance with relevant building and mechanical codes, as well as any local, state or
national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI
Z223.1/NFPA 54 – latest edition. In Canada, see NSCNGPIC for detailed requirements.
Item
• Maintain the following clearances
from both combustible and
non-combustible materials.
Distance from combustibles
• If possible, leave 8" or more on either
side of the unit to facilitate inspection.
• If possible, leave 24" or more in front of
the unit to facilitate maintenance
and service if necessary.
• If possible, leave 3" or more above and
below the vent pipe to facilitate inspec-
repair/inspection
tion and repair if necessary
Securing of space for
CheckIllustration
6" or
more
Distance from
the side
8" or
more
8" or
more
24" or
more
12"
or
more
4" or
more
3"
3"
or more
or more
• There must be a clearance of 24" or
more in front of the Flue terminal.
• This restriction will not be applied to an
area where an effective shield makes a
clearance of 24" or more in front of the
exhaust outlet.
into Any Building
Outdoor Clearances to Opening
There must be no
building opening
within this area.
12"
or more
12" or
more
12" or
more
Flue terminal
12" or
more
7
Clearance Requirements from Vent Terminations to Building Openings
* All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code,
ANSI Z223.1 and in Canada, in accordance with NSCNGPIC.
Clearance
Above grade, veranda, porch, deck,
A=
or balcony
Window or door that may be opened
B=
Permanently closed window
C=
Vertical clearance to ventilated soffit
located above the terminal within a
D=
horizontal distance of 2 feet from the
center of the terminal
Unventilated soffit
E=
Outside corner
F=
Inside corner
G=
Each side of center line extended
H=
above meter/regulator assembly
Service regulator vent outlet
I=
Nonmechanical air supply inlet or
J=
combustion air inlet to any other
appliance
Mechanical air supply inlet
K=
Above paved sidewalk or paved
L=
driveway located on public property
Under veranda, porch, deck, or
M=
balcony
Vent Terminal
Air Supply Inlet
12" (12")
12" (36")
*
*
*
*
*
3' within a height 15' above
meter/regulator assembly
3'
12" (36")
3' above if within 10' (6')
(7' ***)
* (12"- Canada Only****)
Area Where Terminal
is Not Permitted
8
()= indicates clearances required in Canada
*Maintain clearances in accordance with local installation codes and the requirements of the gas supplier
***A vent shall not terminate directly above a sidewalk or paved driveway that is located between two
single family dwellings and serves both dwellings.
****Permitted only if veranda,porch,deck,or balcony is fully open on a minimum of two sides beneath the floor.
7. Installation
Securing to the wall
• The weight of the device will be applied to the wall. If the strength of the wall is not sufficient, reinforcement must be done to prevent the transfer of vibration.
• Do not drop or apply unnecessary force to the device when installing. Internal parts may
Be sure to do
be damaged and may become highly dangerous.
• Install the unit on a vertical wall and ensure that it is level.
Item
CAUTION
• When installing with bare hands, take caution to
not inflict injury.
• Be careful not to hit electrical wiring, gas, or water
piping while drilling holes.
1. Drill a single screw hole, making sure to hit a stud.
2. Insert and tighten the screw and hang the unit by
the upper wall mounting bracket.
Locating Screw Holes
3. Determine the positions for the remaining four screws
(two for the top bracket and two for the bottom), and
remove the unit.
4. Drill holes for the remaining four screws.
5. Hang the unit again by the first screw, and then
insert and tighten the remaining four screws.
6. Take waterproofing measures so that water does
not enter the building from screws mounting the
Mounting
device.
IllustrationCheck
Location of Screw Hole
Mounting Bracket
(upper)
Locating Screw Holes
Tapping Screw
• Make sure the unit is installed securely so that it will
not fall or move due to vibrations or earthquakes.
Structure
• If this water heater is being installed at an elevation of
2,000 ft. or higher, disconnect the connector labeled
"High Elevation Disconnect" as illustrated on the right.
This connector is located inside the unit.
• Disconnect power to the water heater before disconnecting this connector. Failure to perform this step will
result in a "73" code displayed on the remote controller
Above 2,000 ft.
and a cease in operation. If this occurs, disconnect,
then reconnect power to the water heater to reset the
system.
Installations at Elevations
DISCONNECT
HIGH ELEVATION
9
Filling the neutralizer unit with water
The neutralizer unit can be filled before connecting the vent pipe.
Filling the neutralizer unit before vent pipe installation.
Prior to initial start up, make sure that you fill the neutralizer unit with water.
DANGER
Please follow one of the procedures described below to ensure that the neutralizer unit is filled with water.
1) Fill the neutralizer unit by pouring approx. 17 oz.(500ml) of water into the exhaust accessory on the top of
the appliance as illustrated below.
Or, if the vent pipe has already been installed:
2) After installing the drain pipe, make sure that the area around the appliance is well ventilated; open a
window or a door if necessary.
Then, operate the unit and verify that condensate is coming out of the drain pipe.
(During normal use of the water heater, condensate will begin to discharge from the drain pipe within 15 minutes
of use. However, depending on the season and/or installation site conditions, it may take longer.)
This is to prevent dangerous exhaust gases from entering the building.
Failure to fill the neutralizer unit could result in severe personal injury or death.
Intake
17 oz.
500ml
Exhaust
10
Vent Pipe Installation
8.
WARNING
CARBON MONOXIDE POISONING
Follow all vent system requirements in accordance with relevant local or state regulation,
Be sure to do
General Requirements
• This appliance may be vented with either PVC
or CPVC, or stainless steel msterials. Follow
the instructions in this section for the specific
material being used.
• Make sure the vent system is gas tight and will
not leak.
• Support the vent pipe with hangers at regular
intervals as specified by these instructions or
the instructions of the vent manufacturer.
• Do Not common vent or connect more than
one appliance to this venting system.
• The total vent length including horizontal &
vertical vent runs should be no less than 3'.
or, in the absence of local or state code, in the U.S. to the National Fuel Gas Code ANSI
Z233.1/NFPA 54 – latest edition, and in Canada, in accordance with NSCNGPI.
(Indoor Installation Only)
• Do not store hazardous or flammable substances near the vent termination and check
that the termination is not blocked in any way.
• Steam or condensed water may come out
from the vent termination. Select the location
for the termination so as to prevent injury or
property damage.
• If snow is expected to accumulate, take care
the end of the pipe is not covered with snow or
hit by falling lumps of snow.
• Consult the vent pipe manufacturer's installation instructions for chimney connections.
Optional Stainless Steel Vent Piping
• Noritz N-Vent is suggested when stainless
steel venting is required.
• If N-Vent is not used, a UL listed category IV
vent system must be used.
• An adapter may be required if stainless steel
venting is used on this appliance. Refer to
the "Appliance Adapters" section.
Pipe diameter4"
No. of Elbows
439'
345'
251'
157'
* Not including the termination
• Exceeding the maximum vent length is dangerous and may result in bad combustion.
• Maintain the same vent pipe diameter all the
way to the end.
Max. Straight Vent Length*
Clearances
Manufacturer andEnclosed Unenclosed
ProductHor. Vert. Hor. Vert.
Noritz N-Vent4"1"1"
Clearances vary by manufacturer, refer to the UL
approved clearances when using materials other
than N-Vent.
Appliance Adapters
When using a vent system other than N-Vent, an
appliance adapter will be required to properly connect the vent to this appliance. Consult the
manufacturer's instructions for the proper appliance adapter.
10" (sides)
15"(top)
6"(bottom)
11