Nilfisk CLE2.0 User Manual

User's Manual
CLE2.0
COMPRESSOR /LIMITER /GATE
R
LTO
www.altoproaudio.com
Version 2.0 Dec. 2002
English
SAFETY RELATED SYMBOLS
CAUTION
RISK OFELECTRIC SHOCK
DO NOTOPEN
This symbol, wherever used, alerts you to the pre­sence of un-insulated and dangerous voltages with­in the product enclosure. These are voltages that may be sufficient to constitute the risk of electric shock or death.
This symbol, wherever used, alerts you to impo­rtant operating and maintenance instructions. Please read.
Protective Ground Terminal
AC mains (Alternating Current)
Hazardous Live Terminal
ON: Denotes the product is turned on.
OFF: Denotes the product is turned off.
WARNING
Describes precautions that should be observed to prevent the possibility of death or injury to the user.
the recommended fuse type as indicated in this manual. Do not short-circuit the fuse holder. Before replacing the fuse, make sure that the product is OFF and disconnected from the AC outlet.
Protective Ground
Before turning the product ON, make sure that it is connected to Ground. This is to prevent the risk of electric shock.
Never cut internal or external Ground wires. Likewise, never remove Ground wiring from the Protective Ground Terminal.
Operating Conditions
Always install in accordance with the manufacturer's instructions.
To avoid the risk of electric shock and damage, do not subject this product to any liquid/rain or moisture. Do not use this product when in close proximity to water.
Do not install this product near any direct heat source.
Do not block areas of ventilation. Failure to do so could result in fire.
Keep product away from naked flames.
CAUTION
Describes precautions that should be observed to prevent damage to the product.
WARNING
Power Supply
Ensure that the mains source voltage (AC outlet) matches the voltage rating of the product. Failure to do so could result in damage to the product and possibly the user.
Unplug the product before electrical storms occur and when unused for long periods of time to reduce the risk of electric shock or fire.
External Connection
Always use proper ready-made insulated mains cabling (power cord). Failure to do so could result in shock/death or fire. If in doubt, seek advice from a registered electrician.
Do Not Remove Any Covers
Within the product are areas where high voltages may present. To reduce the risk of electric shock do not remove any covers unless the AC mains power cord is removed.
Covers should be removed by qualified service personnel only.
No user serviceable parts inside.
Fuse
To prevent fire and damage to the product, use only
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions
Follow all instructions
Keep these instructions. Do not discard.
Heed all warnings.
Only use attachments/accessories specified by the manufacturer.
Power Cord and Plug
Do not tamper with the power cord or plug. These are designed for your safety.
Do not remove Ground connections!
If the plug does not fit your AC outlet seek advice from a qualified electrician.
Protect the power cord and plug from any physical stress to avoid risk of electric shock.
Do not place heavy objects on the power cord. This could cause electric shock or fire.
Cleaning
When required, either blow off dust from the product or use a dry cloth.
Do not use any solvents such as Benzol or Alcohol. For safety, keep product clean and free from dust.
Servicing
Refer all servicing to qualified service personnel only.
Do not perform any servicing other than those instruc­tions contained within the User's Manual.
PREFACE
Dear Customer:
Thanks for choosing LTO CLE 2.0 Compressor/Limter/Gate and thanks for choosing one of the results of LTO AUDIO TEAM job and researches.
For our LTO AUDIO TEAM, music and sound are more then a job... are first of all passion and let us say... our obsession!
We have been designing professional audio products for a long time in cooperation with some of the major brands in the world in the audio field.
The LTO line presents unparalleled analogue and digital products made by Musicians for Musicians in our R&D Centers in Italy, Netherlands, United Kingdom and Taiwan. The core of our digital audio products is a sophisticated DSP (Digital ound rocessor) and a large range of state of the art algorithms which have been developed by ourSP Software Team for the last 7 years.
Because we are convinced you are the most important member of LTO AUDIO TEAM and the one confirming the quality of our job, we like to share with you our work and our dreams, paying attention to your suggestions and your comments.
Following this idea we create our products and we will create the new ones! From our side, we guarantee you and we will guarantee you also in future the best quality, the best fruits of our continuous researches and the best prices. Our LTO CLE 2.0 is the result of many hours of listening and tests involving common people, area experts, music­ians and technicians.
The results of this effort is that you can acquired an extremely efficient and universal dynamics processor. It contains several new circuits design which make the unit an ultimate dynamic processor: intelligent program recognition, inter­active Expander/Gate and super low distortion VCA (Voltage Controlled Amplifier).
Nothing else to add, but that we would like to thank all the people that made the LTO CLE 2.0 a reality available to our customers, and thank our designers and all the LTO staff, people who make possible the realization of products containing our idea of music and sound and are ready to support you, our customers, in the best way, conscious that you are our best richness.
Thank you very much.
LTO AUDIO TEAM
TABLE OF CONTENTS
1. INTRODUCTION........................................................................................................................................4
2. THE CONCEPT BEHIND..........................................................................................................................4
2.1 Some technical stuff
2.2 Voltage Controlled Amplifier (VCA)
2.3 Inputs
3. CONTROLS................................................................................................................................................6
3.1 Expander/Gate Section
3.2 Compressor Section
3.3 Peak Limiter Section
3.4 Connectors on The Rear Panel
4. READY TO ROLL?.................................................................................................................................10
4.1 Expander/Gate Section
4.2 Compressor Section
4.3 Peak Limiter Section
5. INSTALLATION AND CONNECTION.....................................................................................................12
5.1 Mains Connection
5.2 Audio Connection
5.3 Rack Mounting
6. TECHNICAL SPECIFICATIONS .................................................................................................................................15
7. WARRANTY ...............................................................................................................................................................17
1. INTRODUCTION
You are now the Owner of an CLE 2.0 Compressor/Limiter/Gate. The CLE 2.0 is a very powerful dynamic processor.LTO We have included in it several innovative circuit designs that make the CLE 2.0 a very versatile processor: smart and fast recognition of the program, adjustable Expander/Gate and very low distortion Voltage Control Amplifier (VCA).
Feature List:
Smart Knee Control Compressor (SKC)
Soft knee or hard knee? This is the question! SKC combines both: In the "soft knee" mode you control the program material so that the compression will be the most musical and inaudible. ON the other end, the hard knee function is used for better precision, limiting signal peaks with precision and will allow you to add creativity to the dynamic processing. This function also allows you to protect other equipment in the signal loop against distortion.
2.1.2 Introducing Audio Dynamics
The human ear can detect the noise generating by falling leaves as well as the roar generated by the taking off space shuttle. Unfortunately no analog, nor digital device can reproduce such wide spectrum. Please look at Chart.1 and you will see the difference if dynamic capacity of various devices when compare to the human ear. More pro­blems occur when handling high level signals and low level signals. When you reach the high level limit you may incur in distortion because of the dynamic range of the instrument therefore a certain "reserve" must be maintained to avoid distortion. This reserve is known as "headroom" and it is usually set at 10-20 dB. Would not be easier just to reduce the operating level? Yes it would but you would put low level music signals at the same level of the basic noise floor so the overall quality of the signal would be highly deteriorated. Please look at Chart. 2 and note the Usable dynamic range (including headroom) versus high level distortion generated by peaks, and Noise floor level.
Loading...
+ 13 hidden pages