dansk Brugsanvisning .....................................2, 55-67
823 0060 020 30200 - Edition 2 2005-03
Printed in Sweden by AB Åmålstryck
Instrucciones de uso
............................2, 42-54
2
Contents
1. Important safety precautions ............................................................................................... 30
1.1 Technical data ........................................................................................................................................30
2. Vacuum unit Centix 20 assembly instructions .......................................................... 31
2.1 Fitting the mounting bracket ...........................................................................................................31
2.2 Locating the vacuum cleaner on the mounting bracket .....................................................31
2.3 Connecting the machine ..................................................................................................................31
7.1 Replacing the bag fi lter .................................................................................................................... 36
7.2 Fitting the bag fi lter .......................................................................................................................... 36
7.3 Replacing the dust bag ................................................................................................................... 36
7.4 Fitting the dust bag ..........................................................................................................................36
Congratulations on your choice of central vacuum cleaner! If you use your vacuum cleaner
in accordance with these operating instructions, your machine will be a pleasure to use and
Our products are under constant development and we, therefore, reserve the right
Legislation governing consumer compensation claims apply to this product under current terms of sale - on the assumption that
the product has been used correctly (for household use) and maintained in accordance with the instructions con-
This product comes under the various countries’ statutory requirements concerning the collection and safe treatment
of electrical products and, when the time comes for its disposal, it should be handed over to a dealer
Complaints caused by faulty or incorrect assembly should be made to the installation fi rm responsible.
Entitlement to compensation may not apply through failure to use the machine correctly or gross negligence
an essential worktool in your home for many years to come.
to make any necessary alterations to the design of the machine.
We also make reservations concerning any misprints that may arise.
tained in this user guide. Dust bags are consumables.
or waste disposal site for recycling purposes.
concerning the maintenance of the product.
29
1 Important safety precautions
To reduce the risk of fi re, electric shock or injury,
read all safety precautions and warning text carefully
before using the machine.
• This central vacuum cleaner is solely intended for
dry vacuuming indoors.
• Never vacuum without a fi lter installed.
• Do not vacuum up liquids. Do not use the machine in
wet surroundings.
• Do not vacuum up embers or burning objects
such as cigarettes, matchsticks, hot ash or fl ammable
liquid or gas.
• Do not vacuum in areas where
fl ammable liquids or
gases may be present.
• Unplug the machine before changing the fi lter or bag
and before doing any maintenance work.
• Always unplug the machine by pulling on the plug, not
the power cord.
• The wall socket and plug must be positioned so that
they are clearly visible.
1.1 Technical data
• Do not vacuum up sharp objects such as broken glass or
needles that could puncture the bag.
• Be particularly careful not to pick up objects that
could block the hose/pipe system, such as pencils, toy
bricks and small plastic bags.
• Follow the operating instructions carefully. Servicing and
repairs should only be carried out by an authorised workshop. Use only original parts
and accessories as recommended by the supplier. Never
attempt to modify the machine yourself.
• Do not use the central vacuum cleaner if the power cord
is damaged. The central vacuum cleaner is fi tted with a
special type of power cord that must be replaced with
a cord of the same type if it is damaged. A power cord
of this type can be obtained from a service contact. To
avoid any risk, this power cord should be replaced by a
qualifed expert.
• The central vacuum cleaner must not be used as a toy.
The central vacuum cleaner must never be used to
vacuum up contaminated dust or cement dust.
CENTIX 20CENTIX 40CENTIX
50
Height
Width with handles360 mm440 mm440 mm
Length with bracket400 mm400 mm400 mm
Motor
Fuse10A
Weight5.5 kg6.5 kg6.7 kg
Sound output
Capacity of dust container
Capacity when using dust
bag
Max. suction power
Max. air fl ow52 l/s55 l/s55 l/s
Max. vacuum
These appliances conform with EU directives 89/336/EEC, 73/23/EEC, 93/68/EEC
427 mm800 mm800 mm
1500 W 1700 W 1700 W
10 A10 A
69 dB70.5 dB70.5 dB
-
10 l
435 W 480 W 480 W
24 kPa25 kPa25 kPa
25 l25 l
14 l14 l
30
2 Vacuum unit Centix 20 assembly instructions
Fig. 1
2.1 Fitting the mounting bracket
Position the holder so that there is plenty of space above
and below the place where the vacuum unit is to be located.
Make sure there is a minimum of 500 mm free space above
the Centix 20 container. Mark the positions for the four
screw holes with a pen or similar. Then select appropriate
screws and, if necessary, wall plugs for the type of wall
surface to which the bracket is to be attached. Drill the
four holes for the mounting bracket. The diameter of the
screw holes in the holder is 5 mm. Fit the mounting bracket
with the large opening pointing upwards, see Fig. 1. Tighten
the screws so that the holder is held fi rmly in place (screws
provided).
2.2 Locating the vacuum cleaner on the
mounting bracket
Position the vacuum unit so that the mounting bracket is directly
above the wall bracket, see Fig. 2. Lower the machine down on to
the mounting bracket. Make sure the corresponding bracket on
the machine is held fi rmly in place by the wall bracket.
Fig. 2
Fig. 3
Fig. 4
Fig. 5
2.3 Connecting the machine
The machine is connected with the suction pipe in the uppermost position and
the exhaust pipe in the lower position.
This connection should not be glued but can be taped when the unit is serviced at
a later date. The suction pipe socket can be fi tted to two different points depending on
the direction in which you would like to install the pipe system.
To relocate the suction pipe socket, you need to do the following:
1. Release the suction pipe socket by unscrewing the four combination Torx screws
with a Torx T20 or an ordinary screwdriver, Fig. 3.
2. Pull the socket out of the machine, see Fig. 4.
3. Loosen the plug blanking off the outlet to which you intend moving the suction
pipe socket. Unscrew the four combination Torx screws. Remove the blanking plug
from the machine.
4. Adapt (move) the suction pipe socket to the new outlet. NB! The socket is marked ”Up”.
Make sure the socket is fi tted with ÏUpÓ uppermost. Fasten the socket by fi tting and tightening the four screws, Fig. 5.
5. Fit the blanking plug to the outlet previously occupied by the suction pipe socket. Use the four screws to hold it in place. The
exhaust pipe must be fi rmly attached to the wall to ensure its connection with the socket does not loosen. Remember that
you will need to be able to turn the bent pipe in different directions to ensure a suitable pipe layout. Then connect up the
exhaust pipe and muffl er, Fig 6. Fit the central vacuum cleaner so that the exhaust pipe is as short as possible, max. 10 metres. Take the surroundings into consideration when positioning the exhaust. For this reason, you should always fi t a muffl er.
For additional information concerning the assembly and installation of the pipe system and low-current lead, please refer to the
separate assembly instructions supplied with the pipe package.
Fig. 6
Inlet
Exhaust
31
3 Operating instructions Centix 20
2
1
Fig. 7
3.1 Starting the machine
The control current outlet (low voltage) should be
connected to a control current lead running the length of
the pipes.
Both ends of the low-voltage lead should be connected
to the connection panel on the vacuum cleaner. One lead
to each outlet.
The central vacuum cleaner’s power cable must be
connected to a 230 volt mains socket. The appliance is
double-insulated and does not need to be earthed.
The vacuum cleaner starts and stops automatically.
When the vacuum hose is connected to a vacuum socket,
a metal ring on the end of the hose closes the control
circuit and the vacuum cleaner starts up. 7. When the
hose is removed from the vacuum socket, the vacuum
cleaner stops. You should allow the hose to empty of dust
and dirt before switching the vacuum cleaner off.
Fig. 9
Filter
3.2 Servicing
Always unplug the power cord before
doing any service work!
If suction is poor, it indicates that the fl ow of air through
the machine is restricted. This may be due to the following:
• The dust bag is full and should be replaced.
• The fi lter is clogged and should be cleaned.
The vacuum cleaner has a thermal cut-out that trips if
the vacuum cleaner becomes overheated. If this happens
- unplug the main power cord to reset the vacuum cleaner.
Wait 5-10 minutes to allow the machine to cool down.
While you are waiting, check the hose, dust bag and fi lter
to be sure that nothing is blocking the fl ow of air through
the machine. The vacuum cleaner should now start again.
If the cut-out trips again, you need to get a service fi rm to
remedy the fault.
The Centix 20 should only be operated with a dust bag
and fi lter installed.
Fig. 8
If you use a hose with an on-off switch, you can start
and stop the vacuum cleaner using the switch on the
handle, Fig. 8.
32
4 Filter and dust bags - Centix 20
Fig. 10
Fig. 12
4.1 Replacing the dust bag
The central vacuum cleaner is fi tted with a paper dust
bag as standard; never vacuum without a dust bag installed.
Grasp the edge of the lid and pull upwards to open it, Fig. 10.
Replacing the dust bag: Remove the old dust bag by
turning the cardboard stiffener to the right or left so that
the raised part of the inlet is in line with the opening in the
card. Now slide the bag off the bag nozzle.
Fit the new dust bag as follows: Push the opening in the
cardboard over the elevation on the inlet and pull on the
new bag. Turn the cardboard to lock the bag in place. NB!
Turn the edges of the dust bag down into the container.
This is to avoid damaging the bag with the lid.
Fig. 11
4.2 Replacing / Cleaning the fi lter
Open the lid and take out the dust bag as described earlier.
The fi lter sits at the bottom of the container around the
motor housing. Never use the central vacuum cleaner
without a fi lter installed.
Pull the fi lter out of the container, Fig. 12. The fi lter can be
cleaned by shaking it or washing it in water.
If you wash the fi lter, you must let it dry completely
before refi tting it.
Take the cleaned fi lter and place it in the bottom of the
container. Press the outer edge of the fi lter down against
the sides of the container so that the fi lter bulges up
slightly. Then push the fi lter down into place. Make sure
the fi lter is packed in tightly against the motor housing,
Fig. 13. Reinstall the dust bag and replace the lid. Check
that the lid is fi rmly secured.
Fig. 13
The cardboard stiffener locks the bag in place when you
twist it as shown in Fig. 11 above.
The opening in the card must line up and slide over the
elevation on the inlet before you twist the cardboard
stiffener to lock it.
Plan the positioning of the mounting bracket so that there
is plenty of space above and below the area where the
vacuum unit is to be located. Make sure there is a minimum
of 400 mm free space below the dust container.
Mark the positions for all four screw holes with a pen or
similar. The diameter of the holes in the holder is 5 mm.
Select screws and, if necessary, wall plugs suitable for the
type of wall concerned. Drill the four screw holes.
Fit the mounting bracket with the large opening pointing
downwards, see Fig. 14. Then screw the holder fi rmly
into place.
Fig. 14
Fig. 15
5.2 Locating the vacuum cleaner on
the mounting bracket
To facilitate the procedure, fi rst remove the dust container.
Free the container by pulling both handles outwards. Then
remove the container from the machine. Turn the vacuum
unit until the mounting bracket is immediately below the
bracket on the machine. Lower the machine down on to
the mounting bracket, Fig. 15. Make sure the corresponding
bracket on the machine is held fi rmly in place by the wall
bracket.
5.3 Connecting the machine
The machine is connected with the fl exible suction hose in
the lower position and the exhaust pipe uppermost, Fig 16.
The fl exible suction hose acts as an adapter connecting
the vacuum unit with the pipe system. The accompanying
rubber sleeve is used for tightening/loosening purposes
between the pipe system and the fl exible vacuum hose.
Feed half the length of the sleeve into the vacuum hose
and fold the other half over. Then feed 5-10 mm of the
vacuum hose into the pipe system and fold the sleeve
back so that it envelopes the tail pipe, holds the
vacuum hose in place and tightens the adapter.
Fig. 16
Exhaust
Inlet
NB! This connection must not be glued in case the unit
is serviced.
Position the central vacuum cleaner so that the exhaust
pipe can be kept as short as possible, max. 10 metres. Take
the surroundings into consideration when positioning the
exhaust. For this reason, you should always fi t a muffl er.
For additional information concerning the assembly and
installation of the pipe system and low-current lead, please
refer to the separate assembly instructions supplied with
The control current outlet (low voltage) is connected to a
control current lead running the length of the pipes. Both
ends of the low-voltage lead should be connected to the
connection panel on the vacuum unit. One lead to each outlet.
The central vacuum cleaner’s power cable must be connected
to a 230 volt mains socket. The appliance is double-insulated
and does not need to be earthed.
Fig. 17
2
1
The vacuum cleaner starts and stops
automatically. When the vacuum hose is connected to a
vacuum socket, (Fig. 17) a metal ring on the end of the hose
closes the control circuit and the vacuum cleaner starts up.
When the hose is removed from the vacuum socket, the
vacuum cleaner stops. You should allow the hose to empty of
dust and dirt before switching the vacuum cleaner off.
6.3 Centix 50 Premium Display
The Centix 50 Premium model has a display giving information
about the machine, Fig. 19. The display is illuminated and lights
up on start-up. The display remains illuminated for 15 minutes
after the machine has been switched off. This allows you to
check the current status of the machine after it has been in
operation.
The following information is shown on the display:
Run: 301h 01m 11s
* Run: Shows the machine’s total operating hours, ie, the
period of time the motor has been in operation. The time is
shown in hours, minutes and seconds. When the machine has
been in operation for approximately 700 hours, it will stop.
You must then make immediate contact with an authorised
service workshop for a replacement motor to be installed. You
can reset the machine temporarily and run the motor for an
additional 100 hours (approximately) by unplugging the power
cable and then reconnecting it to the mains socket. Once you
reach the end of the 100 hours of operating time, the machine
will stop again. It will now be necessary for an authorised
service workshop to replace the motor and reset the clock.
Filter / Bag: 80%
Fig. 18
If you use a hose with remote control, you can start and stop
the vacuum cleaner using the switch on the handle, Fig. 18.
6.2 Servicing
Always unplug the power cable before doing any service work!
If suction is poor, it indicates that the fl ow of air through the
machine is restricted. This may be due to the following:
• The dust bag is full and should be replaced.
• The fi lter is clogged and should be cleaned of dust.
The vacuum cleaner has a thermal cut-out that trips if the
vacuum cleaner becomes overheated. If this happens - unplug
the main power cored to reset the vacuum cleaner. Wait 510 minutes to allow the machine to cool down. While you are
waiting, check the hose, dust bag and fi lter to be sure that
nothing is blocking the fl ow of air through the machine. The
vacuum cleaner should now start again. If the cut-out trips
again, you need to get a service fi rm to remedy the fault.
The Centix 40/Centix 50 Premium can be run with or
without the installation of a dust bag - the choice is yours.
These products must always be operated with a bag fi lter
fi tted.
* Filter/Bag: Shows the remaining capacity of the dust bag
and bag fi lter. The indication is shown as a percentage. 0% is
displayed when the bag/bag fi lter is empty. Indication is then
given in increments of 10% at a time. When 90% capacity has
been reached, the display will warn you with the following
fl ashing message: Check fi lter. You should then replace the
dust bag and bag fi lter as soon as possible; see section on fi lter
and dust bag. Once the dust bag has been replaced, reset the
machine by starting it up again. The indication should then
display 0% again.
The panel on the Centix 50 Premium displays relevant
information about the machine.
A bag fi lter must always be installed in the dust container.
Clean the fi lter in the following way:
1. Start by pulling the pipe socket out of the dust
container.
2. Release the two handles clamping the dust container.
Free them by pulling the handles outwards away from
the container, Fig 20.
3. Do not remove the fi lter from the container. Instead,
give the fi lter a light shaking inside the container to
loosen dust from the fi lter allowing it to fall into the
container, Fig. 21.
4. Lift out the bag fi lter. If a dust bag is being used remove the dust bag. Then empty the container of any
remaining dust in a suitable place.
Fig. 21
Fig. 22
7.2 Fitting the bag fi lter
Replace the bag fi lter in the machine as follows:
1. Replace the cleaned/shaken bag fi lter in the
container, Fig. 22. Make sure the fi lter support fi ts into
the inner edge of the dust container properly. Check
that the fi lter is fi tted the right way up - the cloth
handle on the fi lter should be visible.
2. Then replace the dust container with the bag fi lter in
the cleaner’s vacuum unit.
3. Close the container on the vacuum unit by applying
inward pressure to the two handles to ensure the
vacuum unit and dust container are fi tted together
properly.
4. Fit the inlet socket to the machine.
Fig. 23
7.3 Replacing the dust bag
The machine is supplied with a paper dust bag.
Replace the dust bag in the following way:
1. Pull the inlet socket out of the machine.
2. Release the two handles clamped on to the dust
container. Free them by pulling the handles outwards
away from the container.
3. Lift off the container.
4. Shake the dust from the bag fi lter. It may be
advantageous for the fi lter to be installed in the
container in such a way that dust in the fi lter can be
shaken down into the dust container.
5. Lift out the bag fi lter.
6. Remove the dust bag by taking hold of the cardboard
stiffener and carefully pulling out the card and bag
from the container, Fig. 23.
7. Empty the container of dust.
Fig. 24
7.4 Fitting the dust bag
Replace the dust bag as follows:
1. Fit the dust bag’s card with a hole into the bag holder,
Fig. 24.
2. Replace the cleaned/shaken bag fi lter in the
container. Make sure the fi lter support fi ts into the
inner edge of the dust container properly.
Check that the fi lter is fi tted the right way up - the
cloth handle on the fi lter should be visible, Fig. 22.
3. Replace the dust container on the vacuum unit. Close
the container on the vacuum unit by applying inward
pressure to the two handles to ensure the vacuum unit
and dust container are fi tted together properly.
4. Replace the inlet socket in the machine.
36
8 Electrical connection
On/Off
The control current outlet (low voltage) is connected to
a control current lead running the length of the pipes.
Both ends of the low-voltage lead are connected to the
connection panel on the vacuum unit. One lead to each
outlet. The low-voltage lead should be connected as
illustrated below.
The central vacuum cleaner’s 230 volt power cord must
be connected to a 230 volt mains socket. The appliance is
double-insulated and does not need to be earthed.
The low-voltage lead is connected to this outlet.
Outlet for the low-voltage leads:
Centix 20
Centix 40
Centix 50 Premium
The connection panel is
located in the top of the
Centix 40 and Centix 50
Premium vacuum unit.
Centix 20
The connection panel is
located in the bottom of
the Centix 20 vacuum
unit.
37
8 Accessories
Telescopic tube
Adjust the length of the telescopic tube by pressing the
button and sliding it in or out. 25. (Maximum length 1000
mm and minimum length 600 mm). For cleaning stairs,
we recommend reducing the length of the tube to the
minimum.
Fig. 25
Standard fl oor nozzle
This is a universal, lightweight fl oor nozzle that can be
used on most fl oor surfaces. You can switch from cleaning
carpets to parquet or other fl ooring, Fig. 26/27.
Fig. 26
Radiator/crevice nozzle
This nozzle is useful for hard-to-reach, restricted areas
such as corners, crevices and radiators.
Fig. 28
Fig. 29
Dusting brush
The dusting brush can be used on lamps, pictures,
curtains and other textiles, Fig. 30.
Fig. 30
Fig. 27
Furniture nozzle
Small, practical nozzle for vacuuming furniture, cushions
and textiles, Fig. 31.
Fig. 31
Remember!
Never vacuum up liquids, broken glass
or hot ash.
Fig. 32
38
10 Troubleshooting
All work involving the 240 volt mains electricity
supply must be carried out by a qualifi ed electrical
contractor with full knowledge of the relevant safety
regulations.
The vacuum cleaner will not start
The vacuum cleaner is fi tted with a thermal cut-out that
may have tripped. If this happens - unplug the main
power cord from the wall socket. Wait fi ve minutes to
allow the machine to cool down. While you are waiting,
check the fi lter and dust bag to be sure that nothing is
blocking the fl ow of air through the machine. After fi ve
minutes, plug the power cord back into the wall socket.
The vacuum cleaner should now start again. If the cut-out
trips again, you need to get a service fi rm to remedy
the fault.
• Are you using the correct hose?
Only the original hoses fi t correctly.
• Does the vacuum cleaner start when you try a
different vacuum socket? If so, there is a fault in the
electrical connection to the fi rst socket. Unscrew the
socket and check the connection at the back.
• Is the power supply connected to the vacuum unit?
• Is there power at the socket?
• Is the low-voltage lead connected to the vacuum unit?
The vacuum cleaner will not stop
• Has a metal object become lodged in one of the
vacuum sockets causing the pins to become fused?
Centix 50 Premium display
The Centix 50 Premium model has a display that shows
relevant status. The display shows the machine’s total
operating hours (Run) It also shows the remaining
capacity of the fi lter and dust bag (Filter / Bag).
* Run: Shows the machine’s total operating hours, ie, the
period of time the motor has been in operation. When the
machine has been in operation for approximately 700
hours, it stops. You must then make immediate contact
with an authorised service workshop for a replacement
motor to be fi tted. You can reset the machine temporarily
and run the motor for an additional 100 hours
(approximately) by unplugging the power cable and then
reconnecting it to the mains socket. Once you reach the
end of the 100 hours of operating time, the machine will
stop again. It will now be necessary for an authorised
service workshop to replace the motor and reset the clock.
* Filter/Bag: Shows the remaining capacity of the
dust bag and bag fi lter. The indication is shown as a
percentage. 0% is displayed when the bag/bag fi lter is
empty. Indication is then given in increments of 10% at a
time. When 90% capacity has been reached, the display
will warn you with the following fl ashing message: Check fi lter. You should then check the fi lter and replace the
dust bag and bag fi lter as soon as possible; see section on
fi lter and dust bag. Once the dust bag has been replaced,
reset the machine by starting it up again. The indication
should then display 0% again.
Poor suction power
• Are all the vacuum sockets closed properly?
• Has something become jammed in one of the vacuum
sockets?
• Is the container lid closed properly?
• Is the gasket between the container and the lid in
place?
• Is it damaged?
• Is the pipe system blocked?
• Is the dust bag full or clogged? Model Centix 50
Premium issues a warning with a message on the
panel.
• Is fi lter clogged? Model Centix 50 Premium issues a
warning with a message on the panel.
Service and spare parts
If you need a service or spare parts, contact your local
dealer. In such circumstances, it is always useful if you
can give the technical data shown on the rating plate of
the vacuum unit. The rating plate is adjacent to the lead
intake. It’s a good idea to copy this data here so that it is
readily to hand.
Serial no.: ...................................................................................
Date of purchase: ....................................................................
(please keep your receipt)
39
10.1 Service/maintenance guide - Centix 20
NB! Never vacuum without a fi lter and dust bag installed.
Product How often? Why? How?
Dust bag
Filter in
bottom
Should be replaced
before it becomes
completely full,
depending on use but
normally 2-4 times a
year.
Should be checked
when changing
the bag.
Poor suction and
danger of
creating a
blockage in
the pipe system.
Poor suction can
result. Dust can
fi nd its way into
the motor.
Grasp the edge of the lid and open it by pulling upwards.
Remove the old dust bag by turning the cardboard
stiffener to the right or left so that the elevation on
the nozzle penetrates the opening in the cardboard.
Now slide the bag off the inlet. Push the opening in the
cardboard over the elevation on the inlet and pull on
the new bag. Twist the cardboard to lock the bag in
place. NB! The opening in the card must be adjusted
and pushed past the elevation on the inlet before the
cardboard can be locked into place with a twisting action.
NB! Never vacuum without a dust bag installed.
Remove the dust bag as described above. Remove
the fi lter from the bottom. The fi lter can be cleaned by
shaking it or washing it in water. NB! The fi lter must be
completely dry before being reinstalled. Replace the
cleaned fi lter in the machine. Press the outer edge of the
fi lter down against the sides of the container so that the
fi lter bulges up slightly. Refi t the dust bag and replace the
lid. Check that the lid is sitting fi rmly in place.
Should be emptied
before the container
is 3/4 full, depending
on use but normally
2-4 times a year.
Should be replaced
before it becomes
completely full,
depending on use but
normally 2-4 times
a year.
Should be shaken
when the container is
emptied.
NB: Only use dry
cleaning methods
Danger of
blockage in the
pipe system.
Poor suction
and danger
of creating a
blockage
in the pipe
system.
To maintain good
suction power.
Remove the hose from the machine. Then loosen the
handles on the container (pull out from the machine) to
free the container from the machine. Lift out the fi lter
and dust bag - see additional information below. Empty
the dust into a plastic bag and put in dustbin. Any
remaining dust or fl uff can be removed manually.
Remove the hose from the machine. Then loosen the
handles on the container (pull out from the machine)
to free the container from the machine. Lift off the
container. Lift out the fi lter. Then remove the dust bag
by pulling the bag’s cardboard stiffener off the nozzle.
Replace in reverse order.
Start by pulling the hose out of the dust container.
Loosen the handles on the container by pulling the
handles in an outward direction from the machine.
Remove the container from the machine.
Do not remove the fi lter from the container. Instead, give
the fi lter a light shaking inside the container to loosen
dust from the fi lter and allow it to fall into the container.
Lift out the bag fi lter. If a dust bag is being used remove it. Then empty the dust from the container in a
suitable place.