411.4 (Eyepoint height when PD is 64mm.)
191.3
315
407.4 (Minimum microscope height)
414.6 (When PD is 64mm.)
105
188.5
247.7
206.4
226.8
101.5
381.7 (When PD is 64mm.)
Unit: mm
Biological Microscope
Dimensional Diagram
Optical system CFI60 (infinity optical system)
Parfocal distance: 60mm
Magnification 40–1500X for observation
8–500X for 35mm photomicrography
Eyepiece tube E2-TB Binocular tube, E2-TF Trinocular tube
Siedentopf type (Inclination: 30°, Interpupillary
distance: 47-75 mm, 360° rotatable)
C-TE Ergonomic Binocular Tube (inclination: 1030º, extension: 40mm)
Eyepiece CFI E 10X (F.O.V.: 20mm), CFI E 15X (F.O.V.: 12mm)
Photo lens PLI projection lens: 2X, 2.5X, 4X, 5X
Nosepiece Quadruple nosepiece, reversed type
Coarse/fine Fine: 0.2mm per rotation, Coarse: 37.7mm per
focusing rotation, Minimum reading: 2 microns on left-side
fine control knob, Coarse motion torque
adjustable, Refocusing system incorporated in
stage, Stage handle and focusing knob are at equal
distance from the operator
Stage Rectangular 216 x 150 mm surface stage mounted
on the main body. Cross travel 78 x 54 mm using
low-positioned X/Y coaxial control knob
Objectives CFI E Plan Achromat 4X N.A. 0.10 (W.D. 30mm)
CFI E Plan Achromat 10X N.A. 0.25 (W.D. 0.7mm)
CFI E Plan Achromat 40X N.A. 0.65 (W.D.
0.65mm)
CFI E Plan Achromat 100X Oil N.A. 1.25 (W.D.
0.23mm)
As an option, CFI Achromat DL and other
higher-grade CFI60 objectives can be used
Condenser E2 Abbe condenser N.A. 1.25; leaf-type
aperture diaphragm with position guide
markings for respective CFI E Plan objectives
Optional condensers:
E2 Phase condenser N.A. 1.25; leaf-type
aperture diaphragm with position guide
markings for respective CFI Achromat DL
objectives
For microscope without field diaphragm:
C-C Achromat Condenser
Achromat Swing-out Condenser
Darkfield Condenser, dry type
C-C Phase Contrast Condenser
Illumination system 6V-20W halogen bulb, 6V-30W halogen bulb
Intermediate E200 epi-fluorescence attachment, Teaching
attachment
* head (face-to-face and side-by-side types),
Drawing tube, Eye level riser
*Maximum intermediate space 50mm
E200 Specifications
Printed in Japan (0810-05)T Code No. 2CE-MTDH-8
This brochure is printed on recycled paper made from 40% used material.
Specifications and equipment are subject to change without any notice or obligation
on the part of the manufacturer. October 2008 ©2000-08 NIKON CORPORATION
WARNING
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING
MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.
NIKON CORPORATION
6-3, Nishiohi 1-chome, Shinagawa-ku,
Tokyo 140-8601, Japan
phone: +81-3-3773-8973 fax: +81-3-3773-8986
http://www.nikon.com/products/instruments/
NIKON INSTRUMENTS INC.
1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.
phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A. only)
fax: +1-631-547-0306
http://www.nikoninstruments.com/
NIKON INSTRUMENTS EUROPE B.V.
Laan van Kronenburg 2, 1183 AS Amstelveen, The Netherlands
phone: +31-20-44-96-222 fax: +31-20-44-96-298
http://www.nikoninstruments.eu/
NIKON INSTRUMENTS (SHANGHAI) CO., LTD.
CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030
(Beijing branch) phone: +86-10-5869-2255 fax: +86-10-5869-2277
(Guangzhou branch) phone: +86-20-3882-0552 fax: +86-20-3882-0580
NIKON SINGAPORE PTE LTD
SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668
NIKON MALAYSIA SDN. BHD.
MALAYSIA phone: +60-3-7809-3688 fax: +60-3-7809-3633
NIKON INSTRUMENTS KOREA CO., LTD.
KOREA phone: +82-2-2186-8410 fax: +82-2-555-4415
NIKON CANADA INC.
CANADA phone: +1-905-602-9676 fax: +1-905-602-9953
NIKON FRANCE S.A.S.
FRANCE phone: +33-1-4516-45-16 fax: +33-1-4516-45-55
NIKON GMBH
GERMANY phone: +49-211-941-42-20 fax: +49-211-941-43-22
NIKON INSTRUMENTS S.p.A.
ITALY phone: +39-055-300-96-01 fax: +39-055-30-09-93
NIKON AG
SWITZERLAND phone: +41-43-277-28-67 fax: +41-43-277-28-61
NIKON UK LTD.
UNITED KINGDOM phone: +44-208-247-1717 fax: +44-208-541-4584
NIKON GMBH AUSTRIA
AUSTRIA phone: +43-1-972-6111-0 fax: +43-1-972-6111-40
NIKON BELUX
BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45
The first microscope in its class to feature CFI60 infinity optics,
plus an anti-mold design to en sure years of high-quality use
F
or the first time, the CFI60 optical system—
infinity optics of the world's highest level—has
been incorporated into a microscope of this class.
The result is stunningly sharp and clear images at
any magnification. Of course, the Eclipse E200
maintains the same operational ease and rigidity
common to all Nikon microscopes and is compatible
with many accessories for higher-grade Eclipse series
microscopes.
Is mold a problem? Not any more.
By using anti-mold paint and sealing anti-mold agent
inside the microscope at critical places, the Eclipse
E200 is designed for use even in hot and humid
environments.
Moreover, this instrument packs all of these features
into a contemporary design that blends in with the
clean interiors of your hospital and examination
rooms.
Best of all, the Eclipse E200 is affordable. Once you
use it, you'll realize what an outstanding performer it
is, despite its modest price.
Eclipse E200-F
(model with field diaphragm)
Eclipse E200