Nice Automation Easy K User Manual

Dichiarazione CE di conformità / EC declaration of conformity
Numero /Number: 114/K.. Data / Date: 05/2003 Revisione / Revision: 4
Il sottoscritto Lauro Buoro, Amministratore Delegato, dichiara che il prodotto:
The undersigned Lauro Buoro, General Manager of the following producer, declares that the product:
Nome produttore / Producer name : NICE s.p.a.
Indirizzo / Address : Via Pezza Alta 13, 31046 Z.I. Rustignè - ODERZO - ITALY
Tipo / Type : Trasmettitore e ricevitore serie “K” / Transmitter and receiver type “K”
Ricevitori / Riceivers KX1, KX2, KXI, KXI2, KXM, KXM220
Accessori / Accessories : Antenne orientabili / Adjustable antenna ABK and ABKIT
Moduli/ Modules MXD, MXT, MXP (solo per / only for KXM, KXM220)
è conforme ai requisiti essenziali richiesti dall’articolo 3 della Direttiva R&TTE 1999/5/CE, per l’uso cui
l’apparecchio è destinato, essendo stati applicati i seguenti Standard:
comply with the essentials requirements of article 3 of the R&TTE 1999/5/EC Directive, if used for its intended use and that the
following standards has been applied:
Riferimento n° Edizione Titolo norma
Livello di valutazione
Reference n° Issue Regulation title Estimate level
ETS 301-489-03 11/2001 Electromagnetic compatibility and Radio spectrum Matters (ERM); Classe II
ElectroMagnetic Compatibility (EMC) standard for radio equipment
and services
EN 300220-3 2000 Electromagnetic compatibility and Radio spectrum Matters (ERM); Classe I(LPD)
Short Range Devices (SRD);Radio equipment to be used in the
25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mW;
Part 3: Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive
EN 60950 1992 Apparecchiature per la tecnologia dell’ informazione.
Sicurezza /Safety of information technology equipment
I trasmettitori e ricevitori NICE serie “K” sono stati testati presso il seguente organismo:
The transmitters and riceivers NICE serie “K” have been tested with the following corporation:
TGM WIEN (Istituto di stato di elettrotecnica ed elettronica) in VIENNA
TGM WIEN (State Institute of Electrical and Electronic Engineering)
I trasmettitori hanno ottenuto certificato di conformità e di opinione di esperto presso:
The transmitters have obtained the certificate of conformity and the expert opinion at:
CETECOM-ICT Services GmbH –Germany (Notified Body n° 0682)
I trasmettitori hanno ottenuto certificato di conformità CE del tipo:
The transmitters have obtained the certificate of EC-type examination at
TGM WIEN – VIENNA (Notified Body n° 0732)
I trasmettitori NICE serie “K” sono stati, notificati secodo l’ articolo 6.4 della Direttiva 5/1999/EC, ai maggiori
paesi europei. Per informazioni, fare richiesta a NICE s.p.a.
The transmitters NICE serie “K” have been notified underArticle 6.4 of the Directive 1999/5/EC, to the major european countries.
Should you need any information, please to contact NICE s.p.a.
ODERZO, 28 Maggio 2003 (Amministratore Delegato)
(General Manager)
Lauro Buoro
easyK
Instructions and warnings for fitters
Istruzioni ed avvertenze per l’installatore
Instructions et recommandations pour l’installateur
Anweisungen und Hinweise für den Installateur
Instrucciones y advertencias para el instalador
Instrukcje i ostrzez.enia dla instalatora
ISTQUAR-A 4851 REV.04
remote controls
www.niceforyou.com
Nice S.p.a. Oderzo TV Italia
Via Pezza Alta, 13 Z.I. Rustignè
Tel. +39.0422.85.38.38
Fax +39.0422.85.35.85
info@niceforyou.com
Nice Padova Sarmeola I
Tel. +39.049.89.78.93.2
Fax +39.049.89.73.85.2
info.pd@niceforyou.com
Nice Roma I
Tel. +39.06.72.67.17.61
Fax +39.06.72.67.55.20
info.roma@niceforyou.com
Nice Belgium
Leuven (Heverlee) B
Tel. +32.(0)16.38.69.00
Fax +32.(0)16.38.69.01
info@nicebelgium.be
Nice España Madrid E
Tel. +34.9.16.16.33.00
Fax +34.9.16.16.30.10
kamarautom@nexo.es
Nice France Buchelay F
Tel. +33.(0)1.30.33.95.95
Fax +33.(0)1.30.33.95.96
info@nicefrance.fr
Nice France Sud Aubagne F
Tel. +33.(0)4.42.62.42.52
Fax +33.(0)4.42.62.42.50
info.marseille@nicefrance.fr
Nice Rhône-Alpes
Decines Charpieu F
Tel. +33.(0)4.78.26.56.53
Fax +33.(0)4.78.26.57.53
info.lyon@nicefrance.fr
Nice Polska Pruszków PL
Tel. +48.22.728.33.22
Fax +48.22.728.25.10
nice@nice.com.pl
2
41 mm
98 mm
25 mm
12-24 Vac/dc
OUT1
+ -
OUT2
A
312145
162
455BU 9701
10
BC
10÷18 V
18÷28 V
B
MXD
NA
A
MXP MXT
NA
NC
A
B
NC
B
NC
NA
NC
A
RL 2
119-A LS
NC
NA
NA
NC
RL 1
AB
NA
T1 - OUT1 T2 - OUT1 T3 - OUT1 T4 - OUT1
10÷18V
18÷28V
OUT1 OUT3OUT2 OUT4
KXM: 12-24 Vac/dc
12 3 645 78910
12
A
T1
T2
T3
T4
B
1 10
MXT
455BU 9701
MXP
MXD
M
21
KXM220: 230Vac
+-
52 mm
147 mm
118 mm
108 mm
13
12
9
6
3
4
T1
T1
T2
T3
T2 T4
T1 T1
T3
T2 T4
K1 K2
K4 K2+2
5
1 2
7a
ON
110
10
ON
OUT2
OUT1
ON
ON
OUT4
OUT3
ON
11
T1
K1M
K2M
K4M
T2
T1
T2
T1
T3
T4
8
T2 - OUT1T1 - OUT1 T2 - OUT2T1 - OUT2
T4 - OUT1T3 - OUT1 T4 - OUT2T3 - OUT2
7b
Product description
Technical Featurest
Receivers
Reception frequency : 26.995 - 27.120 - 30.875 - 30.900MHz
quartz controlled versions
Power input : 24V or 12Vac/dc ± 10%
230 Vac ± 10% for KXM220
Sensitivity : < 0.5µV (range 100-400 mt
with ABK- ABKIT aerial) Stand-by/active channel consumption : 35 mA / 55 mA Decoding : digital (1024 combinations) N° outputs : from 1 to 4 depending on the versions Relay contact : max. 0.5A 48Vac/dc. Excite / de-excite time : 150mS / 300mS Operating temperature : -10°C +55°C
Transmitters
Transmission frequency : 26.995 - 27.120 - 30.875 - 30.900MHz
quartz controlled versions Radiated power : 100µW (-10 dBm) Range : 200-400m standard version
100-300m mini version Consumption during transmission : 30mA standard version
25mA mini version Coding : digital (1024 combinations) N° buttons : 1, 2 or 4 depending on version Operating temperature : -10°C + 55°C Dimensions / weight standard K series : 102x56x23 mm / 106g Dimensions / weight mini K series : 75x38x17mm / 42g
The K series radio control device is a system which enables the user to remote control door opening devices, gate opening devices and similar systems. The system works by transmitting and receiving a digital code featuring 1024 combinations for each transmitter button.
Installation: Receivers
The KX1, KX2 and KXM receivers can be powered by 24Vac/dc or 12Vac/dc. The power input mode can be selected by means of a jumper with tab (ref. A fig.3 ). The KXM receiver is switched on by means of a spring return selector switch (ref.A fig.4).
Make sure the power input mode is correct before powering the receiver.
In all the versions, the receiver outputs are normally open (N.O.) pure contacts provided by the relays on the board. In the KXM and KXM220 versions, the outputs are provided through the plug-in relay units (ref. M fig.4); there are three kinds of relay unit: MXD: this output is impulsive, that is, it remains active as long as the command signal remains. MXP: this output is step-by-step, that is, each command signal switches the status of the relay contact. MXT:
this output is timed, that is, after being activated it remains so for a period of time that can be adjusted from 3 seconds to about 5 minutes (use a maximum of 2 MXT units).
If a normally closed “NC” type of contact is needed, for versions FLOX1, FLOX2, FLOXB2, FLOXI and FLOXI2 proceed as follows
1. Disconnect the receiver (KX1, KX1) if powered or remove the board from the slot (KXI and KXI2).
2. Open the receiver box and remove the board with care (KX1, KX2).
3. On the solder side of the receiver: cut the copper section at point A and then connect the bump contacts with a spot of solder in point B (fig.9)
In the KXM and KM220 versions, proceed as described in points 2 and 3 on the solder side of the relay units (fig.6).
If more than one receiver is installed close to each other, make sure they are over 50 cm apart in order to prevent interference.
Associating transmitter buttons with r
eceiver output: The KXM and KM220 receivers feature 4 slots for the relay units, each one of which corresponds to a button on the transmitter (fig.4). For the KX1, KXI, KX2 and KXI2 receivers, each output relay is associated with a certain button by inserting a selection jumper (ref. C fig.3): for the KX1 and KXI receivers, refer to figure 7a; for the KX2 and KXI2 receivers, refer to figure 7b. Entering the code:
set the 10 dip switches (ref. B fig.3 and 4) to ON – OFF in order to create the required combination.
Installation: aerial
To guarantee optimum performance, each K receiver must be installed with its own ABK or ABKIT aerial. The aerial must be installed as high as possible; if there are metal structures or reinforced concrete walls nearby, install the aerial on top of them. If the cable supplied with the aerial is too short, use a coaxial cable with an impedance of 52 ohms (e.g.: RG58 with low dispersion); the total length of the cable must not exceed 10 m. Connect the aerial to the relative terminal (fig.3 and 4) by connecting the central part (core) to terminal 2 and the braid to terminal 1. If the aerial must be installed where there is not a good earth level (e.g.: masonry structures), terminal 1 of the aerial can be earthed to obtain a wider range of action; this is clearly advantageous if the quality of the earth connection is good and it is located in the immediate vicinity. Good results can be obtained, however, by using an 18 cm long piece of wire, mounted horizontally and connected to terminal 2 of the aerial input, as an aerial.
Installation: transmitters
Setting the code: Open the transmitter (fig.12 and 13) and set the 10 microswitches with the same combination as the receiver. Associating the transmitter key - r
eceiver output: on transmitters K1-K2 (fig.5) , K1M-K2M (fig.8), besides the 10 microswitches used for setting the code, there are additional microswitches that allow a receiver output to be associated with the transmitter keys (fig. 11); on transmitters K4 and K4M the association of key and output cannot be modified; transmitters K2+2 (fig.5) allow you to activate the OUT1 and OUT2 outputs of a receiver through keys T1 and T2, while the other two T1 and T2 keys can activate the OUT1 and OUT2 outputs of another receiver having a different digital code.
Maintenance
The receiver requires no maintenance whatsoever. The battery in the transmitter must, however, be replaced whenever there is a significant loss of range. Open the stan­dard transmitter as shown in Figure 12 and the mini-transmitter as shown in Figure 13 in order to replace flat batteries.
Disposal
This product is made from various kinds of material, some of which can be recycled while others must be disposed of. Find out about recycling or disposal systems in compliance with current by-laws.
Some electronic components may contain polluting substances: do not dump them.
The available receivers are: tab.1
Version Power input Connections Format Outputs Fixing
KX1 12/24 Vac/dc Term. board Universal (fig.1) 1 Adhesive or screws KX2 12/24 Vac/dc Term. board Universal (fig.1) 2 Adhesive or screws KXI 24 Vac/dc Nice slot Slot 1 Slot on Nice control unit KXI2 24 Vac/dc Nice slot Slot 2 Slot on Nice control unit FLOXM 12/24 Vac/dc Term. board Modular (fig.4) Up to 4 Screws FLOXM220 230 Vac Term. board Modular (fig.4) Up to 4 Screws
The available transmitters are: tab.2
Version Power input Buttons
K1 9V alkaline battery 1 K2 9V alkaline battery 2 K4 9V alkaline battery 4 K2 + 2 9V alkaline battery 4 K1M 12V alkaline battery 1 K2M 12V alkaline battery 2 K4M 12V alkaline battery 4
Nice S.p.a. reserves the right to modify the products whenever it sees fit and without notice.