Place Authorization Card over the RFID icon to register to
1
system. LED will be solid blue.
Place the User Key over the RFID icon you want to add.
2
If successful Æ unit beeps 2 times
If unsuccessful Æ unit beeps 4 times (retry)
Repeat process for all User Keys until they are
successfully added.
The whitelist process can be done on the Secure
Plug unit or through the Remote Access Module.
3
To close the whitelist mode, place the Authorization Card
over the RFID icon. Whitelist mode will end automatically
after 3 minutes of no use. LED will be flashing white.
Unplug any cables from the product end for products that have removable power cords. If the product does not have a
1
removable power cord, turn the power to the product to OFF.
SECURE PLUG™ (PATENT PENDING) USER GUIDE
98
Plug in product cables one at a time to the Power Strip.
2
If successful Æ 2 beeps and LED will be solid green,
this may take 20 to 60 seconds for products with larger
power adapters. The Remote Access Module will show a
corresponding white LED for that socket port.
NOTE: Only supports
products up to 10A.
If unsuccessful Æ unit beeps 4 times and LED will be solid
red. The Remote Access Module will show a corresponding
red LED for that socket port. Unplug cable from the Power
Strip and try again making sure cables are unplugged from
the product.
User Key over the RFID icon to
disarm the system. LED will be
flashing white.
ADDING NEW USER KEYS
From an Armed state, place the User Key over the RFID
1
icon to disarm the system. LED will be flashing white.
From an Alarming state, place the
User Key over the RFID icon to
silence the alarm. Then hold down
the User Key for 5 seconds to
return back to the disarmed state.
LED will be flashing white.
Place Authorization Card over the RFID icon. Follow Key
2
Whitelist process starting on page 4.
Merchandise a new product by
2
following the process on page 5.
If you did not unplug a product,
there is no need to remerchandise
the product again.
DELETING WHITELIST (This will delete all User Keys from the system.)
From an Armed state, place the
1
User Key over the RFID icon to
disarm the system. LED will be
flashing white.
not have any User Keys added. Follow key
whitelist process.
LED is flashing green.Factory Reset
1. Whitelist Mode (if using
LED is solid blue.
LED is flashing blue.Overcurrent/Disarmed
Authorization Card)
2. Overcurrent
System has no whitelist or Authorization
Card. Follow key whitelist process.
1. System is in whitelist enrollment mode.
Follow whitelist process to add User Keys.
2. System has gone into overcurrent
protection. Unplug any product which
may be drawing too much power.
System has gone into overcurrent protection
and user has disarmed the system. Unplug
any product which may be drawing too
much power. The system will self-heal.
LED is flashing yellow.
LED is solid yellow.
1. Ready to be Armed without
MTI Connect Mesh Connected
2. Merchandising Calibration
without MTI Connect Mesh
Connected
1. Armed without MTI Connect
Mesh Connected
2. Delete Whitelist Mode (If using
Authorization Card)
2. System is calibrating product, wait until
successful or unsuccessful merchandising
before proceeding.
1. Add Secure Plug unit to
Mesh network.
2. System is deleting whitelist. Wait until
complete.
10
LED STATUS INDICATORS
SECURE PLUG™ (PATENT PENDING) USER GUIDE
Visual ReferenceSystem StatusConditionSolution
Individual LED is solid white
(not main LED)
Individual LED is solid red
(not main LED)
LED is flashing blue.
Merchandising successful for
that socket port
1. Merchandising unsuccessful
for that socket port
2. Alarm
1. Provisioning Mode
2. Overcurrent/Disarmed
See main LED for overall system status.
1. If merchandising fails, unplug the
product. Follow merchandising process
again.
2. System is alarming on corresponding
socket port and needs to be attended to.
See main LED for overall system status
1. System has entered Mesh network
provisioning mode. If it’s within range
of a Hub that is also in provisioning
mode, it will join the Hub’s network
within 5 seconds and it will stop
flashing blue.
2. System has gone into overcurrent
protection and user has disarmed the
system. Unplug any product which
may be drawing too much power. The
system will self-heal.
LED is flashing multiple colors.
System has received an
“identify” command from a user
of the MTI Connect software.
This device complies with Part 15 of the FCC Rules.
Caution: If any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could
void the user’s authority to operate the equipment.
The RF Exposure Compliance distance is 20 millimeters.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
CAN ICES-3(B)/NMB-3(B)
Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage
est susceptible de compromettre le fomctionnement du dispositif.
CAN ICES-3(B)/NMB-3(B)
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain
Canadian information on RF exposure and compliance.
Le dispositif rencontre l’exemption des limites courantes d’évaluation dans la section 2.5 de RSS 102 et la conformité à l’exposition de RSS-102 rf,
utilisateurs peut obtenir l’information canadienne sur l’exposition et la conformité de rf.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated
with a minimum distance of 20 millimeters between the radiator and your body.
Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou émetteur. Cet équipement devrait être installé et
actionné avec une distance minimum de 20 millimètres entre le radiateur et votre corps.
Technical Data
Model: 165-00471
Operating Frequency: 125KHz
Operating Temperature: 0° C to 40° C
Max Power: 125KHz: <42dBuA/m at 10m
Technical Data
Model: 165-00645 / 165-00670
Operating Frequency: 125KHz, 2.4GHz: 2405-2480MHz
Operating Temperature: 0° C to 40° C
Max Power: 125KHz: <42dBuA/m at 10m
2.4GHz: <20dBm
MTI declares that the radio equipment models 165-00460, 165-00470 and 165-00471 Secure Plug Power distribution units including the
models 165-00645 and 165-00670 Remote Access Modules in compliance with EU Directive 2014/53/EU.
The full text of the EU Manufacturer’s Declaration of Conformity is available at the following internet address: www.mobiletechinc.com
Merchandising Technologies Inc.
Unit B, 9/F., Great Wall Factory Building 11 Cheung Shun Street,Lai Chi Kok,Kowloon, Hongkong