MSI E7520 Master S2M, E7520U Master-A2, E7520 Master, MS-9136 User Manual

Page 1
i
English V ersion
G52-S9136X1
MS-9136 SSI Server Board
E7520 Master Series
Page 2
ii
FCC-A Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Notice 1
The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Notice 2
Shielded interface cables and A.C. power cord, if any, must be used in order to comply with the emission limits.
VOIR LA NOTICE D’INSTALLATION A VANT DE RACCORDER AU RESEAU.
Micro-Star International
MS-9136
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 3
iii
Copyright Notice
The material in this document is the intellectual property of MICRO-STAR INTERNATIONAL. We take every care in the preparation of this document, but no
guarantee is given as to the correctness of its contents. Our products are under continual improvement and we reserve the right to make changes without notice.
Trademarks
All trademarks are the properties of their respective owners. Intel® and Pentium® are registered trademarks of Intel Corporation.
PS/2 and OS®/2 are registered trademarks of International Business Machines Corporation. Windows® 95/98/2000/2003/NT/XP are registered trademarks of Microsoft Corporation. Netware® is a registered trademark of Novell, Inc. Award® is a registered trademark of Phoenix Technologies Ltd. AMI® is a registered trademark of American Megatrends Inc.
Revision History
Revision Revision History Date
V1.0 First release July 2004
Technical Support
If a problem arises with your system and no solution can be obtained from the user’s manual, please contact your place of purchase or local distributor. Alternatively, please try the following help resources for further guidance.
Visit the MSI website for F AQ, technical guide, BIOS updates, driver updates,
and other information: http://www.msi.com.tw/program/service/faq/
faq/esc_faq_list.php
Contact our technical staff at: support@msi.com.tw
Page 4
iv
1. Always read the safety instructions carefully.
2. Keep this User’s Manual for future reference.
3. Keep this equipment away from humidity.
4. Lay this equipment on a reliable flat surface before setting it up.
5. The openings on the enclosure are for air convection hence protects the equip­ment from overheating. DO NOT COVER THE OPENINGS.
6. Make sure the voltage of the power source and adjust properly 110/220V be­fore connecting the equipment to the power inlet.
7. Place the power cord such a way that people can not step on it. Do not place anything over the power cord.
8. Always Unplug the Power Cord before inserting any add-on card or module.
9. All cautions and warnings on the equipment should be noted.
10. Never pour any liquid into the opening that could damage or cause electrical shock.
11. If any of the following situations arises, get the equipment checked by a service personnel:
h The power cord or plug is damaged. h Liquid has penetrated into the equipment. h The equipment has been exposed to moisture. h The equipment has not work well or you can not get it work according to
User’s Manual.
h The equipment has dropped and damaged. h The equipment has obvious sign of breakage.
12. DO NOT LEA VE THIS EQUIPMENT IN AN ENVIRONMENT UNCONDITIONED, STOR­AGE TEMPERA TURE ABOVE 600 C (1400F), IT MA Y DAMAGE THE EQUIPMENT .
Safety Instructions
CAUTION: Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer.
Page 5
v
CONTENTS
FCC-A Radio Frequency Interference Statement.......................................................... ii
Copyright Notice ........................................................................................................... iii
Trademarks.................................................................................................................... iii
Revision History ............................................................................................................ iii
Technical Support.......................................................................................................... iii
Safety Instructions ........................................................................................................ v
Chapter 1. Getting Started.................................................................................... 1-1
Mainboard Specifications ...................................................................................1-2
Mainboard Layout ...............................................................................................1-6
MSI Special Features ..........................................................................................1-7
PC Alert™ III ................................................................................................ 1-7
Chapter 2. Hardware Setup .................................................................................. 2-1
Quick Components Guide ...................................................................................2-2
Central Processing Unit: CPU ............................................................................. 2-3
CPU Installation Procedures for Socket 604 ..............................................2-4
Memory ...............................................................................................................2-5
Memory Bus Features ................................................................................ 2-5
Memory Population Rules............................................................................2-6
Installing DDR Modules................................................................................ 2-6
Memory Speed/CPU FSB Support Matrix ................................................... 2-7
Power Supply .....................................................................................................2-8
SSI 24-Pin Power Connector: JPWR1 ........................................................ 2-8
SSI 8-Pin Power Connector: JPWR2 .......................................................... 2-8
Back Panel .......................................................................................................... 2-9
Connectors .......................................................................................................2-10
Floppy Disk Drive Connector: FDD1 ......................................................... 2-10
Chassis Intrusion Switch Connector: JCI1...............................................2-10
Fan Power Connectors: FAN1/2/3/5/6 .....................................................2-10
A TA100 Hard Disk Connectors: IDE1 & IDE2 ............................................ 2-11
Serial ATA RAID 0, 1 Connectors: SATA1, SATA2 ..................................2-12
Front USB Connector: USB2.....................................................................2-13
Front Panel Connector: JSSI1 ................................................................... 2-13
Ultra320 SCSI Connectors: SCSI1/SCSI2 (Optional) ................................2-14
SCSI LED Connector: JSCSI (Optional).................................................... 2-14
SSI 5-Pin Power Connector: CN14 ...........................................................2-15
4-pin I2C Bus Connector: CN28 ................................................................2-15
5-pin I2C Bus Connector: CN15 ................................................................2-15
Page 6
vi
System ID Button: CN31............................................................................2-16
Serial Port Connector: COM 2 ................................................................... 2-16
Jumpers ............................................................................................................ 2-17
Clear CMOS Jumper: JBAT1 .....................................................................2-17
BIOS Boot Block Protect Jumper: J1......................................................... 2-18
System Configure Jumper: CN40 .............................................................2-18
Slots ..................................................................................................................2-19
PCI (Peripheral Component Interconnect) Slots ....................................... 2-19
PCI Interrupt Request Routing ................................................................... 2-20
SO DIMM (Small Outline DIMM) .................................................................. 2-21
Chapter 3. BIOS Setup ........................................................................................... 3-1
Entering Setup .................................................................................................... 3-2
Control Keys ............................................................................................... 3-2
Getting Help ................................................................................................. 3-3
General Help <F1> ...................................................................................... 3-3
The Menu Bar ..................................................................................................... 3-4
Main .....................................................................................................................3-6
System Summary................................................................................................3-8
Advanced ........................................................................................................... 3-9
IPMI (Optional) ...................................................................................................3-16
Security............................................................................................................. 3-19
Boot ...................................................................................................................3-21
Exit.....................................................................................................................3-22
Appendix A: SCSI BIOS Setup (Optional) .......................................................... A-1
Entering SCSI BIOS ............................................................................................ A-2
Control Keys .............................................................................................. A-2
Selecting the SCSI Channel ....................................................................... A-2
Selecting the Management Type................................................................ A-2
Configure/View SCSI Controller Settings.......................................................... A-4
SCSI Bus Interface Definitions .................................................................. A-4
Additional Options ...................................................................................... A-5
BIOS Information ........................................................................................ A-8
Disk Utilities ........................................................................................................ A-9
Appendix B: Adaptec SATA RAID Utility for Intel ICH-HR ................................ B-1
Introduction ........................................................................................................ B-2
1. Overview ............................................................................................... B-2
2. Operating System Compatibility ............................................................. B-2
3. Storage Requirements ........................................................................... B-2
Page 7
vii
4. Features................................................................................................. B-2
5. Storage Management Software Overview........................................... B-2
Installing the Driver ............................................................................................ B-4
1. Installing the Driver in a New Windows System................................... B-4
2. Installing the Driver in an Existing Windows System ............................ B-5
3. Installing Red Hat Linux 7.3 or 8.0 ......................................................... B-5
4. Installing SuSE Linux 8.0 or 8.1 ............................................................. B-6
Installing Adaptec Storage Manager – Browser Edition................................... B-7
1. Overview ............................................................................................... B-7
2. Supported Browsers............................................................................. B-7
3. Typical, Custom, and Compact Installations .......................................... B-7
4. Installing Adaptec Storage Manager on Windows ............................... B-8
5. Installing Adaptec Storage Manager on Linux .....................................B-11
Using Adaptec Storage Manager – Browser Edition ..................................... B-12
1. Overview ............................................................................................. B-12
2. Architecture Overview........................................................................ B-13
3. Logging In ............................................................................................. B-13
4. Installing a Security Certificate ............................................................ B-14
5. Registering Your Software.................................................................. B-14
6. The Basics ........................................................................................... B-15
Adaptec RAID Configuration Utility.................................................................. B-19
1. Using the Array Configuration Utility ................................................... B-19
2. Using the Disk Utilities .......................................................................... B-22
Glossary .......................................................................................................... B-23
Page 8
1-1
Getting Started
Thank you for choosing the E7520 Master Series (MS-9136 v1. X) SSI server board. The E7520 Master Series are superior computer mainboards based on Intel® Lindenhurst & Hance Rapids chipsets for optimal system efficiency. Designed to fit the advanced Intel
®
XeonTM processors in the 604 pin package, the E7520 Master Series provide a solution for front-end and general purpose server/ workstation in the entry-level and mid-range market segment.
Chapter 1. Getting Started
Getting Started
Page 9
1-2
MS-9136 SSI Server Board
Mainboard Specifications
CPU
h Dual XeonTM (FSB 800MHz) processors in the 604-pin package h 1MB L2 Cache h 6.4GB/s Trans Rate
Chipset
h Intel® Lindenhurst (E7520) MCH (Memory Controller Hub) h Intel® Hance Rapids ICH (I/O Controller Hub) h Intel® PXH PCI bridge
Memory Bus Feature
h Supports 8 184-pin DDR DIMMs up to 32 GB with DDR 266 or 16 GB with DDR 333 h Dual-Channel DDR 266 (4-DIMM per channel)/333 (3-DIMM per channel) registered
ECC DIMM
Slots
h One PCI (32-bit/33MHz) slot h Two PCI-X (64-bit/100MHz) slots (the green one for Adaptec Zero-Channel RAID &
Intel RAIDIOS)
h One PCI-X (64-bit/133MHz) slot h Two PCI Express x8 slots (PCI Express Bus specification v1.0a compliant)
HDD Interface
h SCSI interface supported by Adaptec AIC-7902 Ultra-320 SCSI controller (Optional)
- Integrated Adaptec AIC-7902 Ultra-320 SCSI adapter
- Supports dual-channel Ultra320 LVD SCSI
- Supports Adaptec ZCR & Intel RAIDIOS (Zero-Channel RAID)
h Serial ATA RAID interface supported by Intel® Hance Rapids ICH (with 2 SATA
connectors onboard/can connect up to 2 Serial ATA drives)
h Ultra A TA/100 Bus Master IDE interface supported by Intel® Hance Rapids ICH (with
2 IDE connectors onboard/can connect up to 4 Ultra ATA drives)
Onboard Peripherals
h On-Board Peripherals include:
- 1 floppy port supports 2 FDDs with 360K, 720K, 1.2M, 1.44M and
2.88Mbytes
- 1 parallel port supports SPP/EPP/ECP mode
- One PS/2 keyboard port
- One PS/2 mouse port
- 2 serial ports (COM1 & COM2)
- 1 VGA port
- 4 USB 2.0 ports (Rear * 2/ Front * 2)
- 2 RJ45 LAN jacks
Page 10
1-3
Getting Started
Network
h Intel® 82541GI Gigabit Ethernet Controller
Power Management Features
h Wake on LAN (WOL)/USB/PCI/Mouse/Ring (WOR) h RTC alarm h Supports ACPI S1, S4, and S5 function
System Management
h SMBus (I2C) h Hardware monitoring h Thermal protection h Chassis intrusion
BIOS
h 8 Mbit Flash EEPROM h PCI 2.2 compliant, VPD, and DMI h SMBIOS 2.3, ACPI 2.0 h Supports PXE boot protocol h APM 1.2, WOL, WOR h PC2001 system design compliant
Dimension
h SSI EEB 3.0 Form Factor: 12.0 x 13.0 inch
Mounting
h 17 mounting holes in total, including CPU fan mounting holes
MSI Reminds You...
Enabling the functionality of Hyper-Threading Technology for your computer system requires ALL of the following platform Components: *CPU: Intel® Pentium® 4 or Xeon™ Processors with HT Technology; *Chipset: Intel® Chipsets that support HT Technology; *BIOS: A BIOS that supports HT Technology and has it enabled; *OS: An operating system that supports HT Technology. For more information on Hyper-threading Technology, go to:
http://www.intel.com/info/hyperthreading
Page 11
1-4
MS-9136 SSI Server Board
Mode Refresh Minimum Amount of Memory Required
rate(Hz) 640x480 60 640X480 7 2 640X480 7 5 640X480 9 0 640X480 100 800X600 6 0 800X600 7 0 800X600 7 5 800X600 9 0 800X600 100 1024X768 6 0 1024X768 7 2 1024X768 7 5 1024X768 9 0 1024X768 100 1280x1024 43 1280x1024 60 1280x1024 70 1280x1024 72 1600x1200 66 1600x1200 76
8bpp 16bpp 24bpp 32bpp 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 4MB 4MB 6MB 2MB 4MB 4MB 6MB 2MB - 4MB 6MB 2MB - 4MB 6MB 4MB 4MB 6MB 8MB 4MB 4MB 6MB -
Table 1. 2D Modes (TFT or CRT)
Shading indicates modes not supported by TFT
MSI Reminds You...
Please refer to Table 1 for 2D modes supporting both CRT and LCD. The table specifies the minimum memory requirements for various display resolutions, refresh rates and color depths.
Video
h Integrated ATI Radeon™ 7000 graphics controller
- Onboard 8MB Video SDRAM
Page 12
1-5
Getting Started
MSI Server Management IPMI 1.5 (optional)
MSI-9569 BMC card (with QLogic Zircon UL BMC) and MSI iConsole AP support IPMI 1.5 (option)
MS-9569 BMC Card Specifications
BMC Chip
- Qlogic Zircon UL ( ARM7 TDMI 32-bit/40MHz RISC), 128-pin PQFP
- Host hardware interface: LPC interface
- Host software interface: KCS interface
Memory Size
- 256 X 16 Bits SRAM
- 4M Bits Flash
Form Factor
- Add-on Card on SO-DIMM (144 pin, Key position in 50)
Onboard Connector/Header
- JTAG header (14 pin) for debugging
Key Features
- IPMI 1.5 Compliant
- Out-of-band LAN based management using RMCP
- FRU/SEL access
- Remote out-of-band alerts
- Event log
- Supports CLI (command line interface) over Serial or shared NIC (RMCP)
- Ability to update firmware inband unattended
- Remote access security (MD5)
- Out-of-band environmental monitoring and alerting
- Secure remote power control and system reset over Serial or shared NIC (RMCP)
- Supports Microsoft EMS
- Supports onboard I2C ADT 7463, Winbond 83791 to extend Hardware monitor feature
- Supports ASR (Automatic Server Restart)
System Management
Two SMBus 2.0 (I2C)
- One SMBus for Intel® 82541
- One SMBus for ADT 7463, Winbond 83791, SEEPROM access, CPU thermal sensor
CPU Fan speed control dependent on System Temperature System Fan speed control dependent on System Temperature
Sensor Management
Monitored Voltage: +5V, +3.3V, Vcore Thermal protection (CPU/System overheat shut down through BMC) No Chassis Intrusion LED x 3 (ID_LED, BMC Heartbeat, Status LED ) On-Board Diagnostic LEDs ( 6 x Memory DIMM, 2 x CPU, 10 x FAN ) Supports shared NIC (Intel® 82541)
Page 13
1-6
MS-9136 SSI Server Board
Mainboard Layout
MS-9136 v1.X SSI Server Board
DIMM2
DIMM6
DIMM4
DIMM8
DIMM1
DIMM5
DIMM3
DIMM7
JPWR1
B
A
T
T
+
PCI 6
PCI 5
PCI 4
PCI 2
PCI 3
USB Ports
T: Mo us e B: Keyboard
LAN
JPWR2
PCI 1
I
D
E
2
I
D
E
1
F
D
D
1
JCI1
SATA1
SATA2
FAN6
FAN5
FAN3
CN21
CN39
FAN2
J
B
A
T
1
C
N
4
0
J
1
J
2
J
3
C
O
M
2
C
N
3
1
J4
J5
Adaptec
AIC-7902W
Intel
Hance Rapids
ATI
RADEON
S
C
S
I
2
Top: Parallel Port
Bottom: COM Port & VGA Port
SCSI 1
JSSI1
USB2
S
O
C
K
E
T
6
0
4
m
P
G
A
S
O
C
K
E
T
6
0
4
m
P
G
A
CN14
FAN1
CPU1
CPU2
Intel
Lindenhurst
Intel
PXH
Intel
82541
Gigabit LAN
Intel
82541
Gigabit LAN
CN44
Page 14
1-7
Getting Started
MSI Special Features
PC Alert™ III
The PC AlertTM III is a utility you can find in the CD-ROM disk. The utility is just like your PC doctor that can detect the following PC hardware status during real time operation:
Ø monitor CPU & system temperatures Ø monitor fan speed(s) Ø monitor system voltage Ø monitor chassis intrusion
If one of the items above is abnormal, the program main screen will be immediately shown on the screen, with the abnormal item highlighted in red. This will continue to be shown until user disables the warning.
MSI Reminds You...
1. Items shown on PC Alert™ III vary depending on your system status.
2. The mainboard bound with MS-9569 BMC card (Server Manage­ment Features) won’t support PC Alert™ III.
Page 15
2-1
Hardware Setup
Chapter 2. Hardware Setup
Hardware Setup
This chapter provides you with the information about hard­ware setup procedures. While doing the installation, be careful in holding the components and follow the installation procedures. For some components, if you install in the wrong orientation, the compo­nents will not work properly.
Use a grounded wrist strap before handling computer components. Static electricity may damage the components.
Page 16
2-2
MS-9136 SSI Server Board
Quick Components Guide
CPU, p.2-3
CN14, p.2-15
FAN3, p.2-10
Back Panel I/O, p.2-9
DIMM1~8, p.2-5
FAN5, p.2-10
S
O
C
K
E
T
6
0
4
m
P
G
A
S
O
C
K
E
T
6
0
4
m
P
G
A
JPWR2, p.2-8
PCI Slots,
p.2-19
SCSI1/2,
p.2-14
JSCSI1, p.2-14
CN15, p.2-15
COM2, p.2-16
IDE2/1,
p.2-11
JSSI1, p.2-13
FAN1, p.2-10
JPWR1, p.2-8
JCI1, p.2-10
J1, p.2-18
CN40, p.2-18
USB2, p.2-13
JBAT1, p.2-17
SATA1/2, p.2-12
CN28, p.2-15
FAN6/2,
p.2-10
FDD1,p.2-10
CN39,p.2-21
Page 17
2-3
Hardware Setup
The mainboard supports Single/Dual Intel® Xeon™ processor(s). The mainboard uses two CPU sockets called Socket 604 for easy CPU installation. You can install SINGLE or DUAL CPUs on the board to meet your own needs. Keep the following points in mind before installing CPU(s):
1. If SINGLE CPU is intended, always install the CPU on the CPU1 socket.
2. To install DUAL CPUs on the board, you must use the same type of CPUs running at the same FSB frequency.
When you are installing the CPU, make sure the CPU has a Heat Sink and a cooling fan attached on the top to prevent overheating. If you do not find the Heat Sink and cooling fan, contact your dealer to purchase and install them before turning on the computer.
Central Processing Unit: CPU
MSI Reminds You...
Overheating will seriously damage the CPU and system, always make sure the cooling fan can work properly to protect the CPU from overheating. The system temperature needs to remain under 45°C. We highly recommend that the direction of inlet air should follow the direction indicated above for better cooling effect.
Replacing the CPU
While replacing the CPU, always turn off the SSI power supply or unplug the power supply’s power cord from grounded outlet first to ensure the safety of CPU.
S
O
C
K
E
T
6
0
4
m
P
G
A
S
O
C
K
E
T
6
0
4
m
P
G
A
CPU1
Recommended inlet air direction
Page 18
2-4
MS-9136 SSI Server Board
1. Please turn off the power and unplug the power cord before installing the CPU.
2. Pull the lever sideways away from the socket. Make sure to raise the lever up to a 170-de­gree angle.
3. Look for the gold arrow. The gold arrow should point towards the lever pivot. The CPU can only fit in the correct orientation.
4. If the CPU is correctly installed, the pins should be completely embedded into the socket and can not be seen. Please note that any violation of the correct installation procedures may cause permanent damages to your mainboard.
5. Press the CPU down firmly into the socket and close the lever. As the CPU is likely to move while the lever is being closed, al­ways close the lever with your fingers pressing tightly on top of the CPU to make sure the CPU is properly and completely embed­ded into the socket.
CPU Installation Procedures for Socket 604
Open Lever
Sliding
Plate
Gold arrow
Gold arrow
Gold arrow
Correct CPU placement
Incor rect CPU placement
X
O
Close Lever
Press down
the CPU
Page 19
2-5
Hardware Setup
Memory
The mainboard provides 8 slots for 184-pin DDR DIMM (Double In-Line Memory Module) modules. You can install PC2100/DDR266 or PC2700/DDR333 DDR SDRAM modules on the DDR DIMM slots (DIMM 1~8).
Memory Bus Features
Support for direct connect of two DDR channel interfaces, DDR266/DDR333 tech-
nology
Full operation support in single channel mode on either interfaceStacked or unstacked DIMM support for registered DDR266 technology(up to four
DIMMs per channel)
Stacked or unstacked DIMM support for registered DDR333 technology(up to
three DIMMs per channel)
144-bit wide with ECC, DDR266/DDR333 memory interface supports x72, ECC,
registered DDR266/DDR333 DIMMs (using 128 Mb, 256 Mb, 512Mb, and 1 Gb)
Maximim 16 GB support with DDR333 up to two stacked DIMMs(1 Gb x4 DRAMs)Maximim 32 GB support with DDR266 up to two stacked DIMMs(1 Gb x4 DRAMs)Data bandwidth per channel 2.13 GB/s (DDR266) / 2.7 GB/s (DDR333)Support for S4EC/D4ED (144,128) x4, Intel x4 Single Device Data Correction (x4
SDDC) ECC in dual channel mode
Support SEC/DED (72,64) ECC on each channel when Intel Single Device Data
Correction (SDDC) is disabled
D I M M
A1
D I M M
B1
D I M M
A2
D I M M
B2
D I M M
B3
D I M M
B4
D I M M
A3
D I M M
A4
CKE:0/12/34/56/70/12/34/56/7
0/0# 2/2# 3/3#1/1# 1/1# 3/3#2/2#0/0#Clock: C/S: 0/1 4/5 6/74/50/1 2/3 2/3 6/7 SPD: A0h A2h A4h A6hA8h AAh ACh AEh
MCH
Do not install for DDR333
12345678
Page 20
2-6
MS-9136 SSI Server Board
Memory Population Rules
The mainboard supports both single- & dual-channel modes. Install at least one DIMM module on the slots. You can install either single- or double-sided modules to meet your own needs. In dual-channel mode, make sure that you install memory
modules of the same type and density on DDR DIMMs “in pairs” -- {DIMM1 & DIMM2}, {DIMM3 & DIMM4}, {DIMM5 & DIMM6}, {DIMM7 & DIMM8}.
Memory modules can be installed in any combination as follows:
DDR333 DIMM slot population
DIMM Configuration DIMM 1, 2 DIMM 3, 4 DIMM 5, 6 DIMM 7, 8
1 Single Rank E (Empty) E Single Rank E 1 Dual Rank E E Dual Rank E 2 Single Ranks E Single Rank Single Rank E 1 Dual Rank, 1 Single Rank E Dual Rank Single Rank E 2 Dual Ranks E Dual Rank Dual Rank E 3 Single Ranks Single Rank Single Rank Single Rank E 1 Dual Rank, 2 Single Ranks Dual Rank Single Rank Single Rank E
DDR266 DIMM slot population
DIMM Configuration DIMM 1, 2 DIMM 3, 4 DIMM 5, 6 DIMM 7, 8
1 Single Rank E (Empty) E E Single Rank 1 Dual Rank E E E Dual Rank 2 Single Ranks E E Single Rank Single Rank 1 Dual Rank, 1 Single Rank E E Dual Rank Single Rank 2 Dual Ranks E E Dual Rank Dual Rank 3 Single Ranks E Single Rank Single Rank Single Rank 1 Dual Rank, 2 Single Ranks E Dual Rank Single Rank Single Rank 2 Dual Ranks, 1 Single Rank E Dual Rank Dual Rank Single Rank 3 Dual Ranks E Dual Rank Dual Rank Dual Rank 4 Single Ranks Single Rank Single Rank Single Rank Single Rank 1 Dual Rank, 3 Single Ranks Dual Rank Single Rank Single Rank Single Rank 2 Dual Ranks, 2 Single Ranks Dual Rank Dual Rank Single Rank Single Rank 3 Dual Ranks, 1 Single Rank Dual Rank Dual Rank Dual Rank Single Rank 4 Dual Ranks Dual Rank Dual Rank Dual Rank Dual Rank
Page 21
2-7
Hardware Setup
Installing DDR Modules
1. The DDR DIMM has only one notch on the center of module. The module will only
fit in the right orientation.
2. Insert the DIMM memory module vertically into the DIMM slot. Then push it in until
the golden finger on the memory module is deeply inserted in the socket.
3. The plastic clip at each side of the DIMM slot will automatically close.
MSI Reminds You...
You can barely see the golden finger if the module is properly inserted in the socket.
Volt
Notch
Memory Speed/CPU FSB Support Matrix
DDR266 DDR333
FSB800 OK OK
Page 22
2-8
MS-9136 SSI Server Board
Power Supply
The mainboard supports SSI power supply for the power system. Before inserting the power supply connector, always make sure that all components are installed properly to ensure that no damage will be caused.
SSI 24-Pin Power Connector: JPWR1
This connector allows you to connect to an SSI power supply. To connect to the SSI power supply, make sure the plug of the power supply is inserted in the proper orientation and the pins are aligned. Then push down the power supply firmly into the connector.
SSI 8-Pin Power Connector: JPWR2
This connector provides 12V power output to the CPU.
JPWR2
1
8
5
4
PIN SIGNAL
13 +3.3V 14 -12V 15 GND 16 PS-ON# 17 GND 18 GND 19 GND 20 3VSB 21 +5V 22 +5V 23 +5V 24 GND
PIN SIGNAL
1 +3.3V 2 +3.3V 3 GND 4 +5V 5 GND 6 +5V 7 GND 8 PWR OK 9 5VSB 10 +12V 11 +12V 12 +3.3V
JPWR1 Pin Definition
PIN SIGNAL
5 +12V 6 +12V 7 +12V 8 +12V
PIN SIGNAL
1 GND 2 GND 3 GND 4 GND
JPWR2 Pin Definition
MSI Reminds You...
1. Power supplies of 300watt (and up) are highly recommended for sys­tem stability.
2. Please refer to the Intel/AMD websites for recommended power supplies.
JPWR1
12
1
24
13
Page 23
2-9
Hardware Setup
Back Panel
Mouse
Keyboard USB COM 1 LANVGA
LAN
RJ-45 LAN Jack
Link Indicator
8 1
Activity Indicator
Gigabit LAN Pin Definition
USB Ports
1 2 3 4
Serial Port
PIN SIGNAL
1DCD 2 SIN 3 SOUT 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9RI
VGA Port
Mouse/Keyboard Connector
Pin1
Mouse/KBD
DATA
Pin2 NC
Pin3 GNDPin4 VCC
Pin5
Mouse/KBD Clock
Pin6 NC
PIN SIGNAL
1 RED 2 GREEN 3 BLUE 4 N/C 5 GND 6 GND 7 GND 8 GND 9 +5V 10 GND 1 1 N/C 12 SDA 13 Horizontal Sync 14 Vertical Sync 15 SCL
1 2 3 4 5
6 7 8 9
1
5
11
15
PIN SIGNAL
1 VCC
2 -Data 3 +Data 4 GND
PIN SIGNAL DESCRIPTION
1 D0P Differential Pair 0+ 2 D0N Differential Pair 0­3 D1P Differential Pair 1+ 4 D2P Differential Pair 2+ 5 D2N Differential Pair 2­6 D1N Differential Pair 1­7 D3P Differential Pair 3+ 8 D3N Differential Pair 3-
Parallel
Dump Switch
(Reserved Function)
System ID Button
Page 24
2-10
MS-9136 SSI Server Board
The mainboard provides connectors to connect to FDD, IDE HDD, case, LAN, USB Ports, CPU/system power supply fans, ... and etc.
Floppy Disk Drive Connector: FDD1
The mainboard provides a standard floppy disk drive connector that supports 360K, 720K, 1.2M, 1.44M and 2.88M floppy disk types.
Connectors
Fan Power Connectors: FAN1/2/3/5/6
The FAN1, FAN2, FAN3, FAN5, and FAN6 support system cooling fan with +12V. It supports three-pin head connector. When connecting the wire to the connectors, always note that the red wire is the positive and should be connected to the +12V; the black wire is Ground and should be connected to GND. If the mainboard has a System Hardware Monitor chipset onboard, you must use a specially designed fan with speed sensor to take advantage of the CPU fan control.
FAN5
Sensor
+12V GND
MSI Reminds You...
Always consult the vendors for proper CPU cooling fans.
FAN1/3
Sensor
+12V
GND
FAN2/6
Sensor
+12V
GND
FDD1
Chassis Intrusion Switch Connector: JCI1
This connector is connected to a 2-pin chassis switch. If the chassis is open, the switch will be short. The system will record this status and show a warning message on the screen. To clear the warning, you must enter the BIOS utility and clear the record.
JCI1
1
GND
CINTRU
2
Page 25
2-11
Hardware Setup
IDE1 (Primary IDE Connector) The first hard drive should always be connected to IDE1. IDE1 can connect a
Master and a Slave drive. You must configure second hard drive to Slave mode by setting the jumper accordingly.
IDE2 (Secondary IDE Connector) IDE2 can also connect a Master and a Slave drive.
MSI Reminds You...
If you install two hard disks on cable, you must configure the second drive to Slave mode by setting its jumper. Refer to the hard disk docu­mentation supplied by hard disk vendors for jumper setting instructions.
A T A100 Hard Disk Connectors: IDE1 & IDE2
The mainboard has a 32-bit Enhanced PCI IDE and Ultra ATA66/100 controller that provides PIO mode 0~4, Bus Master, and Ultra ATA66/100 function. You can connect up to four hard disk drives, CD-ROM, 120MB Floppy (reserved for future BIOS) and other devices. These connectors support the provided IDE hard disk cable.
IDE1IDE2
Page 26
2-12
MS-9136 SSI Server Board
Serial A TA RAID 0, 1 Connectors: SATA1, SATA2
The southbridge Intel® Hance Rapids ICH provides a hybrid solution that combines two independent SATA ports for support of up to two Serial ATA (Serial ATA RAID) drives and utilizes Adaptec Embedded Serial ATA RAID Software to support RAID levels 0 and 1 for easy management of the storage subsystems. Both connectors support 1st generation serial ATA data rates of 150 MB/s and are fully compliant with Serial ATA 1.0 specifications.
PIN SIGNAL PIN SIGNAL
1 GND 2 TXP 3 TXN 4 GND
5 RXN 6 RXP 7 GND
SA TA1/2 Pin Definition
Connect to SA TA1 or SAT A2
Take out the dust cover and connect to the hard disk devices
Optional Serial A TA cable
MSI Reminds You...
Please do not fold the Serial A TA cable into 90-degree angle. Otherwise, data loss may occur during transmission.
SATA2SATA1
7
1
7
1
Page 27
2-13
Hardware Setup
Front USB Connector: USB2
The mainboard provides one USB 2.0 pin header USB2 (optional USB 2.0 bracket available) that is compliant with Intel® I/O Connectivity Design Guide. USB 2.0 technology increases data transfer rate up to a maximum throughput of 480Mbps, which is 40 times faster than USB 1.1, and is ideal for connecting high-speed USB interface peripherals such as USB HDD, digital cameras, MP3 players, printers,
modems and the like.
1
2
9
10
USB2
Front Panel Connector: JSSI1
The mainboard provides one front panel connector for electrical connection to the front panel switches and LEDs.
JSSI1
34
Standby Power (5V)
Power LED
HDD LED
Reset Switch
Power Switch
Giga-bit LAN1 LED
Giga-bit LAN2 LEDSMBus
Chassis Intruder
33
2 1
Pin Description Pin Description
1 Power LED + 2 5Vs/b 3 Key 4 No Connection
5 Power LED - 6 No Connection 7 HDD Activity LED + 8 System Status LED + 9 HDD Activity LED - 10 System Status LED ­11 Power Switch+ 1 2 NIC Activity LED + 1 3 Power Switch- (GND) 14 NIC Activity LED ­1 5 Reset Switch+ 1 6 SMBus SDA 17 Reset Switch- (GND) 1 8 SMBus SCL 1 9 ACPI Sleep Switch 2 0 Chassis Intrusion 2 1 ACPI Sleep Switch (GND) 22 NIC#2 Activity LED + 2 3 NMI to CPU Switch 24 NIC#2 Activity LED ­25 Key 26 Key 27 ID LED+ 28 SYSRDY+ 29 ID LED- 30 SYSRDY­31 ID# 32 NC 33 GND 34 NC
JSSI1 Pin Definition
PIN SIGNAL PIN SIGNAL
1 USBPWR 2 USBPWR 3 USBP2- 4 USBP3­5 USBP2+ 6 USBP3+ 7 GND 8 GND 9 Key 10 N C
Pin Definition
Page 28
2-14
MS-9136 SSI Server Board
Ultra320 SCSI Connectors: SCSI1/SCSI2 (Optional)
SCSI (Small Computer System Interface) is a parallel interface standard for attaching peripheral devices to computers. Ultra320 SCSI is the seventh generation of SCSI I/O technology, and has a maximum data rate speed of 320 MB/sec. SCSI’s commitment to backward compatibility and legacy support are the primary reasons for its durability as an I/O interface, making SCSI the industry standard for disk drive connection in virtually all high-performance servers.
SCSI LED Connector: JSCSI (Optional)
This connector is used to connect to a LED for showing the activity of SCSI devices attached to the SCSI connectors.
Pin Description Pin Description
1 +DB(12) 35 -DB(12) 2 +DB(13) 36 -DB(13) 3 +DB(14) 37 -DB(14) 4 +DB(15) 38 -DB(15) 5 +DB(P1) 39 -DB(P1) 6 +DB(0) 40 -DB(0) 7 +DB(1) 41 -DB(1) 8 +DB(2) 42 -DB(2) 9 +DB(3) 43 -DB(3) 10 +DB(4) 44 -DB(4) 11 +DB(5) 45 -DB(5) 12 +DB(6) 46 -DB(6) 13 +DB(7) 47 -DB(7) 14 +DB(P) 48 -DB(P) 15 GROUND 49 GROUND 16 DIFFSENS 50 GROUND 17 TERMPWR 51 TERMPWR 18 TERMPWR 52 TERMPWR 19 RESERVED 53 RESERVED 20 GROUND 54 GROUND 21 +ATN 55 -ATN 22 GROUND 56 GROUND 2 3 +BSY 57 -BSY 24 +ACK 58 -ACK 25 +RST 59 -RST 26 +MSG 60 -MST 27 +SEL 61 -SEL 28 +C/D 62 -C/D 29 +REQ 63 -REQ 30 +I/O 64 -I/O 31 +DB(8) 65 -DB(8) 32 +DB(9) 66 -DB(9) 33 +DB(10) 67 -DB(10) 34 +DB(11) 68 -DB(11)
68-Pin Ultra320 SCSI Connector
1
35
34 68
SCSI1/2
PIN SIGNAL
1 VCC5 2 SCSI_LED 3 SCSI_LED 4 VCC5
Pin Definition
MSI Reminds You...
SCSI LED connects to JFP1 HDD LED (storage LED) pins. The JSCSI is used to connect SCSI card LED signal.
1
JSCSI
Page 29
2-15
Hardware Setup
SSI 5-Pin Power Connector: CN14
This connector provides power supply for the System Management Bus (SMB).
PIN SIGNAL
1 SMB clock 2 SMB data 3 PS alert 4 GND 5 3.3RS
Pin Definition
PIN SIGNAL
1 SMBUS_SDA 2 GND 3 SMBUS_SCL 4NC
CN28 Pin Definition
CN15 Pin Definition
PIN SIGNAL
1 SMBCLK 2 SMBDATA 3NC 4 GND 5 VCC3
4-pin I2C Bus Connector: CN28 5-pin I2C Bus Connector: CN15
The mainboard provides I2C (also known as I2C) Bus connectors for users to connect to System Management Bus (SMBus) interfaces.
CN14
1
1
CN28
CN15
1
Page 30
2-16
MS-9136 SSI Server Board
System ID Button: CN31
The CN31 system ID button is designed to facilitate the management of two or more MS-9136 systems. When one of the systems crashes, users may press the CN31 button on the back panel of all systems (or alternatively press the identical System ID Button on the front panel) and the system ID LED of the crashed system will simultaneously light up, helping users to easily identify the broken system and get it fixed. By pressing the CN31 button again, the system ID LED will go out.
CN31
Back Panel
Serial Port Connector: COM 2
The mainboard provides one 9-pin header as serial port COM 2. The port is a 16550A high speed communication port that sends/receives 16 bytes FIFOs. You can attach a serial mouse or other serial devices directly to it.
PIN SIGNAL DESCRIPTION
1 DCD Data Carry Detect 2 DSR Data Set Ready 3 SIN Serial In or Receive Data 4 RTS Request To Send 5 SOUT Serial Out or Transmit Data 6 CTS Clear To Send 7 DTR Data Terminal Ready 8 RI Ring Indicate 9 GND Ground
Pin Definition
COM 2
1
9
2
8
Page 31
2-17
Hardware Setup
The motherboard provides the following jumpers for you to set the computer’s function. This section will explain how to change your motherboard’s function through the use of jumpers.
Clear CMOS Jumper: JBA T1
There is a CMOS RAM onboard that has a power supply from external battery to keep the data of system configuration. With the CMOS RAM, the system can automatically boot OS every time it is turned on. If you want to clear the system configuration, use the JBAT1 (Clear CMOS Jumper) to clear data.
Jumpers
MSI Reminds You...
You can clear CMOS by shorting 2-3 pin while the system is off. Then return to 1-2 pin position. Avoid clearing the CMOS while the system is on; it will damage the mainboard.
Keep CMOS Clear CMOS
1
1
JBA T1
1
Page 32
2-18
MS-9136 SSI Server Board
System Configure Jumper: CN40
The CN40 jumper determines which mode the system will enter while powered on. Under Normal Mode, the system will enter the assigned OS as usual. Under Configure Mode, the system will directly enter BIOS setup utility. This enables you to modify the BIOS configurations. Under Recovery Mode, you have to insert certain boot disk into the floppy drive before powering on the system. After powered on, the system will read the boot disk and enter DOS. This enables you to update the BIOS with a Flash utility if necessary.
BIOS Boot Block Protect Jumper: J1
This jumper is used to protect the BIOS boot block from virus infection. When locked, the BIOS boot block cannot be accessed, making BIOS update impossible. When BIOS update is intended, remove the jumper cap to disable BIOS flash protection.
Disable BIOS Flash Protection
1
Enable BIOS Flash Protection
1
J1
1
1
1
1
Configure ModeNormal Mode Recovery Mode
CN40
1
Page 33
2-19
Hardware Setup
Slots
PCI (Peripheral Component Interconnect) Slots
The motherboard provides one 32-bit Master PCI slot, three 64-bit PCI-X slots, and two PCI Express x8 slots.
PCI 4: PCI Express x8 slot
PCI 1: 32-bit/33MHz PCI slot from
Hance Rapids, 3.3V device only
PCI 5: PCI Express x8 slot
PCI 6: 64-bit/133MHz PCI-X slot
connecting to PXH channel B,
3.3V device only
MSI Reminds You...
When adding or removing expansion cards, make sure that you unplug the power supply first. Meanwhile, read the documentation for the ex­pansion card to configure any necessary hardware or software set­tings for the expansion card, such as jumpers, switches or BIOS configuration.
PCI 3: 64-bit/100MHz PCI-X slot connecting to PXH channel A,
3.3V device only PCI 2: 64-bit/100MHz PCI-X slot
connecting to PXH channel A,
3.3V device only (supports ZCR card)
Page 34
2-20
MS-9136 SSI Server Board
PCI Interrupt Request Routing
The IRQ, acronym of interrupt request line and pronounced I-R-Q, are hard­ware lines over which devices can send interrupt signals to the microprocessor. The PCI IRQ pins are typically connected to the PCI bus INT A# ~ INT D# pins as follows:
PCI33-32 Routing (From Hance Rapids)
PCI DEVICE IDSEL INT A INT B INT C INT D REQ GNT PCI Slot1 AD17 PIRQB# PIRQC# PIRQD# PIRQA# REQ0# GNT0#
PCI66-32 Routing (From Hance Rapids)
PCI DEVICE IDSEL INT A INT B INT C INT D REQ GNT A TI VGA AD17 PXIRQ0# NA NA NA PXREQ0# PXGNT0# GIGA LAN0 AD18 PXIRQ1# NA NA NA PXREQ1# PXGNT1# GIGA LAN1 AD19 PXIRQ2# NA NA NA PXREQ2# PXGNT2#
PCIX-64 Routing (From PXH Channel A, 100MHz)
PCI DEVICE IDSEL INT A INT B INT C INT D REQ GNT PCI_2 AD18 PAIRQ_4# PAIRQ_5# SCSI_IRQA SCSI_IRQB PAREQ_1# P AGNT_1# PCI_3 AD17 PAIRQ_0# PAIRQ_1# PAIRQ_2# PAIRQ_3# PAREQ_0# PAGNT_0# SCSI_IRQA P AIRQ_6# SCSI_IRQB PAIRQ_7# AIC 7902 AD19 SCSI_IRQA SCSI_IRQB NA NA PAREQ_2# PAGNT_2#
PCIX-64 Routing (From PXH Channel B, 266MHz)
PCI DEVICE IDSEL INT A INT B INT C INT D REQ GNT PCI_6 AD17 PBIRQ_0# PBIRQ_1# PBIRQ_2# PBIRQ_3# PBREQ_0# PBGNT_0#
PCI Express Routing (From MCH)
PCI DEVICE IDSEL INT A INT B INT C INT D REQ GNT PCI_4 Group C x8 PCI_5 Group B x8 PXH Group A x8
Page 35
2-21
Hardware Setup
SODIMM144__8MMP
COM1_DI(I)
1
COM1_RST#(O)
3
COM1_DCD#(I)
5
COM1_RI#(I)
7
COM1_CTS#(I)
9
COM1_DTR#(O)
13
COM1_DSR#(I)
15
COM1_EN/SW#(O)
17
COM2_EN/SW#(O)
19
COM_BUS_EXCH(O)
21
FAN_TACH3(I)
33
POST/I2C_ACK#(O)
23
5VSB_VDD_ANALOG
25
FAN_TACH0(I)
27
FAN_TACH1(I)
29
FAN_TACH2(I)
31
FAN_TACH4(I)
35
FAN_TACH5(I)
37
NC
39
NC
41
NC
43
NC
45
NC
47
NC
49
GND_ANALOG
51
I2C_0_SDA
53
I2C_0_SCL
55
I2C_0_INT#
57
3VSB_ANALOG
59
I2C_2_SDA
61
I2C_2_SCL
63
I2C_INT#(I)
65
SB_PWR_PG(I)
67
Main_PWR_PG(I)
69
ANALOG_VOLT0(I)
71
ANALOG_VOLT1(I)
73
ANALOG_VOLT2(I)
75
ANALOG_VOLT3(I)
77
ANALOG_VOLT4(I)
79
ANALOG_VOLT5(I)
81
ANALOG_VOLT6(I)
83
ANALOG_VOLT7(I)_BAT
85
RTS_SEN_EN(O)
87
3.3VSB_ANALOG
89
NC
91
LPC_AD0
2
COM1_DO(O)
11
INSERT_DET(I)
93
BMC_VER0(O)
95
BMC_VER1(O)
97
PLAN_LVL0(I)
99
PLAN_LVL1(I)
101
PLAN_LVL2(I)
103
PLAN_LVL3(I)
105
SYS_ID0(I)
107
SYS_ID1(I)
109
SYS_ID2(I)
111
SYS_ID3(I)
113
SYS_ID4(I)
115
NC
117
NC
119
GND
121
485+
123
485-
125
GND
127
PWR_BTN_IN(I)
129
PWR_BTN_OUT(O)
131
BMC_Heartbeat(O)
133
BMC_SMI#
135
COM_EXCH_DIS(O)
139
COM_SHUT(O)
141
5VSB
143
LPC_AD1
4
LPC_AD2
6
LPC_AD3
8
GND
10
(I)LPC_CLK
12
LPC_RST#
14
LPC_FRAME#
16
(O)LPC_INT#
20
GND
18
(O)LPC_DRQ#
22
(I)POST/I2C_REQ#
24
5VSB
26
(O)FAN_PWM0
28
(O)FAN_PWM1
30
(O)FAN_PWM2
32
(O)FAN_PWM3
34
(O)FAN_PWM4
36
(O)FAN_PWM5
38
NC
40
NC
42
(I)GP_INT1#
44
(I)GP_INT2#
46
(I)GP_INT3#
48
(I)GP_INT4#
50
GND
52
I2C_1_SDA
54
I2C_1_SCL
56
(I)I2C_1_INT#
58
3.3VSB
60
I2C_3_SDA
62
I2C_3_SCL
64
(I)I2C_3_INT#
66
EPOW#
68
(I)SYS_RST#
70
(O)SYS_RST_OUT
72
(O)SYS_PWRON_OUT
74
(I)SYS_PWRON_IN
76
(O)BMC_WD#
78
(I)FEA_DET0
80
(I)FEA_DET1
82
(O)I2C_0_RST#
84
(O)I2C_2_RST#
86
(O)I2C_2_MUX_DIS#
88
3.3VSB
90
NC
92
LED0
94
LED1
96
LED2
98
LED3
100
LED4
102
LED5
104
LED6
106
NC
110
NC
112
NC
114
NC
116
NC
118
NC
120
GND
122
NC
124
NC
126
GND
128
NC
130
NC
132
(I)SYS_RTC
134
(I)REM_BTN_IN
136
(I)HD_ACT#
138
(I)I2C_DIS_ALL
140
(I)I2C_MEM_SW
142
5VSB
144
LED7
108
SYS_NMI#(I)
137
1 2
CN39
143 144
SO DIMM (Small Outline DIMM)
The SO DIMM has 144 pins and supports a full 64-bit transfer. It is specifically designed for users to install MSI’s proprietary server management tool -- MS-9569 BMC (Baseboard Management Controller) card.
Page 36
4-1
BIOS Setup
Chapter 3. BIOS Setup
This chapter provides information on the BIOS Setup program and allows you to configure the system for optimum use. You may need to run the Setup program when:
An error message appears on the screen during the system boot-
ing up, and requests you to run SETUP.
You want to change the default settings for customized features.
BIOS Setup
MSI Reminds You...
1. The items under each BIOS category described in this chapter
are under continuous update for better system performance.
Therefore, the description may be slightly different from the lat-
est BIOS and should be held for reference only.
2. Upon boot-up, the 1st line appearing after the memory count is
the BIOS version. It is usually in the format:
P9136MS V1.0 150304 where:
1st digit refers to BIOS maker as A = AMI, W = AWARD,
and P = PHOENIX.
2nd - 5th digit refers to the model number.
6th - 7th digit refers to the customer as MS = all standard
customers.
V1.0 refers to the BIOS version.
150304 refers to the date this BIOS was released.
Page 37
4-2
MS-9136 SSI Server Board
Entering Setup
Control Keys
Power on the computer and the system will start POST (Power On Self Test) process. When the message below appears on the screen, press <F2> key to enter Setup.
Press F2 to enter SETUP
If the message disappears before you respond and you still wish to enter Setup, restart the system by turning it OFF and On or pressing the RESET button. You may also restart the system by simultaneously pressing <Ctrl>, <Alt>, and <Delete> keys.
Key <F1> or <Alt-H> <Esc>
arrow keys
or arrow keys
<Home> or <End> <PgUp> or <PgDn> <F5> or <-> <F6> or <+> or <Space> <F9> <F10> <Enter>
Function General Help window Exit this menu Select a different menu Move cursor up and down Move cursor to top or bottom of window Move cursor to next or previous page Select the previous value for the field Select the next value for the field Load the default configuration values for this menu Save and exit Execute command or enter submenu
Page 38
4-3
BIOS Setup
Getting Help
After entering the Setup menu, the first menu you will see is the Main Menu.
Main Menu
The main menu lists the setup functions you can make changes to. You can use the arrow keys ( ↑↓ ) to select the item. The on-line description of the highlighted setup function is displayed at the bottom of the screen.
Sub-Menu
If you find a right pointer symbol (as shown in the right view) appears to the left of certain fields that means a sub-menu can be launched from this field. A sub­menu contains additional options for a field parameter. You can use arrow keys ( ↑↓ ) to highlight the field and press <Enter> to call up the sub-menu. Then you can use the control keys to enter values and move from field to field within a sub-menu. If you want to return to the main menu, just press the <Esc >.
General Help <F1>
The BIOS setup program provides a General Help screen. You can call up this screen from any menu by simply pressing <F1>. The Help screen lists the appropriate keys to use and the possible selections for the highlighted item. Press <Esc> to exit the Help screen.
8 Primary IDE Master 8Primary IDE Slave 8Secondary IDE Master 8Secondary IDE Slave
Page 39
4-4
MS-9136 SSI Server Board
Once you enter PhoenixBIOS Setup Utility, the Main Menu will appear on the screen. On the Main Menu screen, you will see basic BIOS settings including system time & date, and the setup categories the BIOS supplies. Use Arrow keys to move among the items and menus, and make changes to the settings.
Main
Use this menu for basic system configurations, such as time, date etc.
System Summary
Use this menu to view system settings and CPU configurations.
Advanced
Use this menu to set up the items of special enhanced features available on your system’s chipset.
IPMI (Optional)
This setup screen is for IPMI (Intelligent Platform Management Interface) configura­tions and appears only when the MS-9569 BMC card (for Server Management) is installed on the mainboard.
The Menu Bar
System Time [17:45:55]
System Date [06/25/2004]
Legacy Diskette A: [1.2MB 5¼ ]
8Primary IDE Master [CD-ROM] 8Primary IDE Slave [None] 8Secondary IDE Master [None] 8Secondary IDE Slave [None] 8Serial ATA Channel 0 Master [None] 8Serial ATA Channel 1 Master [None]
Language: [English (US)]
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
<Enter> selects field.
Item Specific Help
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 40
4-5
BIOS Setup
Security
Use this menu to set Supervisor and User Passwords.
Boot
Use this menu to specify the priority of boot devices.
Exit
This menu allows you to load the BIOS default values or factory default settings into the BIOS and exit the BIOS setup utility with or without changes.
Page 41
4-6
MS-9136 SSI Server Board
The items inside the Main menu are for basic system information and configuration. Each item includes none, one or more setup items. Use the Up/Down arrow keys or <Tab> to highlight the item or field you want to modify and use the <+> or <-> key to switch to the value you prefer.
System Time
The time format is <HH> <MM> <SS>.
System Date
The date format is <MM> <DD> <YYYY>.
Legacy Diskette A:
This item allows you to set the type of floppy drive installed.
Primary/Secondary IDE Master/Slave, Serial ATA Channel 0/1 Master
Press PgUp/<+> or PgDn/<-> to select [Manual], [None] or [Auto] type. Note that the specifications of your drive must match with the drive table. The hard disk will not work properly if you enter improper information for this category. If your hard disk drive type is not matched or listed, you can use [Manual] to define your own drive type manually.
Main
System Time [17:45:55]
System Date [06/25/2004]
Legacy Diskette A: [1.2MB 5¼ ]
8Primary IDE Master [CD-ROM] 8Primary IDE Slave [None] 8Secondary IDE Master [None] 8Secondary IDE Slave [None] 8Serial ATA Channel 0 Master [None] 8Serial ATA Channel 1 Master [None]
Language: [English (US)]
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
<Enter> selects field.
Item Specific Help
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 42
4-7
BIOS Setup
If you select [Manual], related information is asked to be entered to the following items. Enter the information directly from the keyboard. This information should be provided in the documentation from your hard disk vendor or the system manufacturer.
[Type] Select how to define the HDD parameters [Multi-Sector Transfers] Any selection except Disabled determines
the number of sectors transferred per block
[LBA Mode Control] Enabling LBA causes Logical Block Ad
dressing to be used in place of Cylinders, Heads and Sectors.
[Transfer Mode] Selects the method for transferring the data
between the hard disk and system memory
[Ultra DMA Mode] Indicates the type of Ultra DMA.
Language
Use this setting to set the display language of the BIOS utility.
F1 Help
Esc Exit
Page 43
4-8
MS-9136 SSI Server Board
BIOS Version
This setting shows the BIOS version.
Processor Speed
It shows the processor speed.
Processor 1/2 CPU ID
It shows the ID of the installed CPUs.
Processor 1 L2 Cache
It shows the size of the L2 cache for CPU1.
DIMM Group #1 Status/DIMM Group #2 Status/DIMM Group #3 Status
It shows the status of the DIMM group #1, 2, & 3.
System Memory
It displays amount of conventional memory detected during boot-up.
Extended Memory
It displays the amount of extended memory detected during boot-up.
The items inside the Main menu are for basic system information and configuration. Each item includes none, one or more setup items. Use the Up/Down arrow keys or <Tab> to highlight the item or field you want to modify and use the <+> or <-> key to switch to the value you prefer.
System Summary
BIOS Version: 1.01 Processor Speed: 2.80GHz Processor 1 CPU ID: 0F31
Processor 1 L2 Cache: 1024KB Processor 2 CPU ID: Not Installed DIMM Group #1 Status: Not Installed
DIMM Group #2 Status: Not Installed DIMM Group #3 Status: Normal
System Memory: 624KB Extended Memory: 260608KB
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
<Enter> selects field.
Item Specific Help
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 44
4-9
BIOS Setup
Processor Settings
Press <Enter> to view the settings of the onboard CPU(s).
Hyper-Threading Technology
The processor uses Hyper-Threading technology to increase transaction rates and reduces end-user response times. The technology treats the two cores inside the processor as two logical processors that can execute instructions simultaneously. In this way, the system performance is highly improved. If you disable the function, the processor will use only one core to execute the instructions. Please disable this item if your operating system doesn’t support HT Function, or unreliability and instability may occur. Settings: [Enabled], [Disabled].
Items in the menu are divided into several sub-menus. Each sub-menu provides more settings. To enter the sub-menu, highligh the sub-menu you want to configure and press <Enter>.
Advanced
Processor Settings
Hyper-Threading Technology: [Enabled]
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
Item Specific Help
Setup Warning Setting items on this menu to incorrect values may cause your system to malfunction.
8Processor Settings 8Advanced Chipset Control 8PCI Configuration 8Peripheral Configuration 8Boot Features 8DMI Event Logging 8Console Redirection
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 45
4-10
MS-9136 SSI Server Board
Advanced Chipset Control
The sub-menu is used to configure chipset features for optimal system performance.
Enable Multimedia Timer
This setting controls the multimedia timer.
USB Host Controller
This setting is used to enable/disable the onboard USB controller. Setting options: [Enabled], [Disabled].
Parallel ATA
The chipset contains a PCI IDE interface that supports two IDE channels: Pri­mary (IRQ 14) and Secondary (IRQ 15). Each channel supports two IDE devices, so the system is capable of supporting a total of four IDE devices. Select [Primary], [Secondary], or [Both] to activate chipset IDE interface(s) installed on your system board.
MSI Reminds You...
Enabling the functionality of Hyper-Threading Technology for your computer system requires ALL of the following platform components:
* CPU: An Intel® Pentium® 4 Processor with HT Technology; * Chipset: An Intel® Chipset that supports HT Technology; * BIOS: A BIOS that supports HT Technology and has it
enabled;
* OS: An operating system that supports HT Technology.
For more information on Hyper-threading Technology, go to: www.intel.com/info/hyperthreading
Advanced Chipset Control
Enable Multimedia Timer: [No] USB Host Controller: [Enabled] Parallel ATA: [Both]
Serial ATA: [Enabled] Native Mode Operation: [Auto] SATA RAID Enable: [Disabled] Wake On LAN/PME: [Enabled] Wake On Ring: [Disabled] W ake On RTC Alarm: [Disabled]
Page 46
4-11
BIOS Setup
Serial ATA
This setting allows you to enable or disable the onchip Serial-ATA controller. Settings: [Enabled], [Disabled].
Native Mode Operation
Certain OS does not support Native Mode. In this mode, system BIOS will search all available IRQs to use for HDD.
* New OS that supports switch to Native Mode (WinXP, Windows .NET Server) can set SATA and PATA to Native Mode. * Maximum 6 ATA devices to connect (4 for P-ATA & 2 for S-ATA).
SATA RAID Enable
This feature allows users to enable or disable the RAID function for each SATA hard disk drive. Options: [Enabled], [Disabled].
Wake On LAN/PME
When setting to [Enabled], the feature allows your system to be awakened from the power saving modes through any signal from LAN or any event on PME (Power Management Event). Settings: [Enabled] and [Disabled].
Wake On Ring
The setting specifies whether the system will be awakened from power saving modes when activity or input signal from the specified modem is detected. Options: [Enabled], [Disabled].
Wake On RTC Alarm
This is used to enable or disable the feature of booting up the system on a scheduled time/date from the S3, S4, and S5 state. Setting options: [Disabled], [Enabled].
PCI Configuration
The sub-menu is used to configure the PCI interface.
Reset Configuration Data
Select [Yes] if you want to clear the Extended System Configuration Data (ESCD). Options: [Yes], [No].
MSI Reminds You...
You need to install a modem card supporting power on function for “Wake On Ring” function.
PCI Configuration
Reset Configuration Data: [No]
8Embedded SCSI 8Embedded NIC (Gbit) 8Embedded Video Controller
Page 47
4-12
MS-9136 SSI Server Board
Embedded SCSI (Optional)
The sub-menu is used to configure the onboard SCSI device.
SCSI Controller (Optional)
Use this feature to enable or disable the onboard SCSI controller.
Option ROM Scan (Optional)
Use this feature to initialize device expansion ROM.
Embedded NIC (Gbit)
The sub-menu is used to configure the onboard LAN device.
LAN Controller
Use this feature to enable or disable the onboard LAN controller(s).
Option ROM Scan
Use this feature to initialize device expansion ROM.
Embedded Video Controller
The sub-menu is used to configure the onboard video device.
Onboard VGA Control
Use this feature to enable or disable the onboard VGA controller.
Peripheral Configuration
The sub-menu is used to configure I/O devices for optimal system performance.
Serial port A/B
Setting to [Enabled] allows users to configure the base I/O address and IRQ of Port A/Port B manually. Selecting [Auto] allows BIOS to automatically determine the correct base I/O port address. Options: [Enabled], [Disabled], [Auto].
Base I/O address
It specifies the base I/O address for Port A/Port B. Options: [3F8], [2F8], [3E8], [2E8].
Peripheral Configuration
Serial port A : [Enabled]
Base I/O address : [3F8] Interrupt : [IRQ 4]
Serial port B : [Enabled]
Mode : [Normal] Base I/O address : [2F8]
Interrupt : [IRQ 3] PS/2 Mouse : [Auto Detect] Legacy USB Support: [Enabled]
Page 48
4-13
BIOS Setup
Interrupt
It specifies the interrupt for Port A/Port B. Options: [IRQ 3], [IRQ 4].
PS/2 Mouse
If your system has a PS/2 mouse port and you install a serial pointing device, select [Disabled].
Legacy USB Support
Set to [Enabled] if you need to use any USB 1.1/2.0 device in the operating system that does not support or have any USB 1.1/2.0 driver installed, such as DOS and SCO Unix. Set to [Disabled] only if you want to use any USB device other than the USB mouse. Setting options: [Enabled], [Disabled].
Boot Features
The sub-menu controls system boot features.
Summary Screen
Selecting [Enabled] displays system summary screen during boot up. Options: [Enabled], [Disabled].
Boot-time Diagnostic Screen
Select [Enabled] if you want to view the system diagnostic screen during boot­time. Options: [Enabled], [Disabled].
QuickBoot Mode
Setting the item to [Enabled] allows the system to boot within 5 seconds since it will skip some check items. Available options: [Enabled], [Disabled].
NumLock
[On] or [Off] turns NumLock on or off at boot up. [Auto] turns NumLock on if it finds a numeric key pad. Options: [On], [Off], [Auto].
POST Error Pause
When set to [Enabled], the system will wait for user intervention on critical POST errors. When set to [Disabled], the system will boot with no intervention if possible. Options: [Enabled], [Disabled].
Boot Features
Summary Screen: [Enabled] Boot-time Diagnostic Screen: [Enabled] QuickBoot Mode: [Disabled] NumLock: [Auto] Post Error Pause: [Enabled]
Page 49
4-14
MS-9136 SSI Server Board
DMI Event Logging
Press PgUp/<+> or PgDn/<-> to view DMI event logging.
View DMI Event Log
Press [Enter] to view the contents of the DMI event log.
Event Logging
This setting disables/enables the BIOS to log DMI (Desktop Management Interface) events. Setting options: [Disabled], [Enabled].
ECC Event Logging
This setting disables/enables the BIOS to log ECC (Error Checking & Correcting) events. Setting options: [Disabled], [Enabled].
Mark DMI Events as Read
Press [Enter] and a screen pops up, asking users to confirm whether or not to clear all DMI event logs immediately. Press [Y] and [Enter], the BIOS will clear all DMI event logs right away.
Clear All DMI Event Logs
When this setting is set to [Yes], the DMI event log will be cleared at next POST stage. Then, the BIOS will automatically set this option to [No]. Setting options: [Yes], [No].
Console Redirection
Press PgUp/<+> or PgDn/<-> to configure Console Redirection.
Console Redirection
BIOS Redirection Port: [Disabled]
Baud Rate: [19.2K] Flow Control: [CTS/RTS] Console Type: [PC ANSI] FIFO Level: [Level 14] Console Connection: [Direct] Continue C.R. after POST: [On] # of Video Pages to Support: [1]
DMI Event Logging
Event Log Validity: Valid Event Log Capacity: Space Available
View DMI Event Log: [Enter] Event Logging: [Enabled]
ECC Event Logging: [Enabled] Mark DMI Events as Read: [Enter]
Clear All DMI Event Logs: [No]
Page 50
4-15
BIOS Setup
BIOS Redirection Port
This feature selects the serial port to use for Console Redirection. [Disabled] completely disables Console Redirection. Setting options: [Disabled], [Serial Port A].
Baud Rate
It allows you to select delay befor key repeat. Options: [300], [1200], [2400], [9600], [19.2K], [38.4K], [57.6K], [115.2K].
Flow Control
The Flow Control has to be enabled when EMP is sharing the same serial port as Console Redirection. The Flow Control must be set to [CTS/RTS] or [CTS/RTS+CD] depending on whether a modem is used. Options: [None], [XON/XOFF], [CTS/ RTS].
Console Type
This feature allows you to enable the specified console type. Options: [VT100], [VT100, 8bit], [PC-ANSI, 7bit], [PC ANSI], [UT100+], [VT-UTF8].
FIFO Level
This feature allows you to enable the specified FIFO level. Options: [Level 4], [Level 14].
Console Connection
This feature indicates whether the console is connected directly to the system or a modem is used for connection. Options: [Direct], [Via modem].
Continue C. R. after POST
Selecting [On] will enable Console Redirection after OS has loaded. Options: [On], [Off].
# of Video Pages to Support
This setting controls the number of video pages to allocate for Console Redirec­tion when video hardware is not available.
Page 51
4-16
MS-9136 SSI Server Board
This setup screen appears only when the MS-9569 BMC card (for Server
Management) is installed on the mainboard. Press PgUp/<+> or PgDn/<-> to
configure IPMI.
IPMI (Optional)
IPMI Specification Version
It shows the support version of IPMI specification. (read only)
BMC Device ID
It shows the ID of the BMC device. (read only)
BMC Device Version
It shows the support version of the BMC device. (read only)
BMC Firmware Version
It shows the current BMC firmware version. (read only)
Platform Event Filtering
Setting to [Enabled] triggers the system event sensors inside BMC (Baseboard Man­agement Controller).
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
Disables/Enables triggers for system sensor events inside BMC (Baseboard Management Controller)
Item Specific Help
IPMI Specification Version: 1.5 BMC Device ID: 00 BMC Device Version: 03 BMC Firmware Version: 00.03 Platform Event Filtering: [Enabled] Change COM Port Setting: [No] COM Port On BMC: [Disabled] System Event Logging: [Enabled] Clear System Event Log: [Disabled] Existing Event Log Number: 255 Remaining Event Log Number: 0 Event Log Control
SYS Firmware Progress: [Disabled]
BIOS POST Errors: [Enabled] BIOS POST Watchdog: [Disabled] OS Boot Watchdog: [Disabled]
Timer for Loading OS: [10]
Time Out Action: [No Action]
8System Event Log
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 52
4-17
BIOS Setup
Change COM Port Setting
This setting controls the COM port setting.
COM Port on BMC
This setting disables/enables the COM port on BMC.
System Event Logging
This setting disables/enables the logging of system events.
Clear System Event Log
Enabling this selection will force the BIOS to clear the System Event Log on the next boot. Options: [Disabled], [Enabled].
Existing Event Log Number
It shows the number of existing event logs.
Remaining Event Log Number
It shows the number of remaining event logs.
SYS Firmware Progress
Enabling this selection will log system POST progress. Options: [Enabled], [Disabled].
BIOS POST Errors
Enabling this selection will log BIOS POST errors. Options: [Enabled], [Disabled].
BIOS POST Watchdog
You can enable the system watch-dog timer, a hardware timer that generates either an NMI or a reset when the software that it monitors does not respond as expected each time the watch dog polls it (select the time period in a separate field). Enabling this selection will enable BIOS POST watchdog. Options: [Enabled], [Disabled].
OS Boot Watchdog
You can enable the system watch-dog timer, a hardware timer that generates either an NMI or a reset when the software that it monitors does not respond as expected each time the watch dog polls it (select the time period in a separate field). Enabling this selection will enable OS boot watchdog. Options: [Enabled], [Disabled].
Timer for Loading OS
This setting selects the watchdog time period for loading OS.
Time Out Action
This setting determines the action of the watchdog timer if the OS fails to boot within the preset time period.
Page 53
4-18
MS-9136 SSI Server Board
System Event Log
SEL Entry Number = 1
SEL Record ID = 0010 SEL Record Type = 02 - System Event Record Timestamp = 01.13.2004 10:50:08 Generator Id = 20 00 SEL Message Rev = 04 Sensor Type = 01 - Temperature
-­Sensor Number = 32 - TMP_S2 SEL Event Type = 81 - Upper Non-critical Going SEL Event Data = 57 24 2A
System Event Log
Press <Enter> to display the System Event Log.
Page 54
4-19
BIOS Setup
Security
This section lets you set security passwords to control access to the system at boot time and/or when entering the BIOS setup program. It also allows you to set virus protection at hard disk boot sector.
Supervisor Password Is/User Password Is
It shows the preset supervisor/user password. (read only)
Set Supervisor Password/Set User Password
Enabling Supervisor Password requires a password for entering Setup. The pass- words are not case sensitive. Pressing <Enter> at either Set Supervisor Password or Set User Password displays the following message:
Type the password and press <Enter>. Repeat.
Set Supervisor Password
Enter New Password: Confirm New Password:
[] []
Supervisor Password Is : Clear User Password Is : Clear
Set Supervisor Password : [Enter]
Set User Password : [Enter]
Password on boot : [Disabled] Fixed disk boot sector : [Normal]
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
Item Specific Help
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 55
4-20
MS-9136 SSI Server Board
Password on boot
Choosing [Enabled] requires a password on boot. It requires prior setting of the supervisor password. If the supervisor password is set and this option is disabled, BIOS assumes the user is booting. Options: [Enabled], [Disabled].
Fixed disk boot sector
Write protects the boot sector on the hard disk for virus protection. It requires a password to format the hard disk. Options: [Normal], [Write Protect].
Page 56
4-21
BIOS Setup
Boot
CD-ROM Drive, Removable Devices, Hard Drive
These are the generic types of devices on your system from which you can boot an operating system. You may have more than one device of each type. If so, the generic type is marked with a plus or minus sign. Use the <Enter> key to expand or collapse the devices marked with <+> or <->. Press <Ctrl+Enter> to expand all such devices. To change a device’s priority, first select it with the up-or-down arrows, and move it up or down using the <+> and <-> keys.
Use this menu to arrange and specify the priority of the devices from which
the BIOS will attempt to boot the Operating System.
CD-ROM Drive +Removable Devices +Hard Drive IBA GE Slot 0208 v1217 IBA GE Slot 0209 v1217
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
Item Specific Help
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 57
4-22
MS-9136 SSI Server Board
Exit Saving Changes
When you want to quit the Setup menu, you can select this option to save the changes and quit.
Exit Discarding Changes
When you want to quit the Setup menu, you can select this option to abandon the changes.
Load Setup Defaults
The option allows users to restore all of the BIOS settings to the Optimal Defaults. The Setup Defaults are the default values set by the mainboard manufacturer specifically for the optimized performance of the mainboard.
Discard Changes
The option allows users to restore all of the BIOS settings to previous values.
Save Changes
The option allows users to save the changes without exiting Setup.
Exit
The following sections describe each of the options on this menu. Note that <Esc> does not exit this menu. You must select one of the items from the menu or menu bar to exit.
Exit Saving Changes
Exit Discarding Changes Load Setup Defaults Discard Changes Save Changes
PhoenixBIOS Setup Utility
Main System Summary Advanced IPMI Security Boot Exit
Item Specific Help
F1 Help
↑↓ Select Item
-/+ Change Values F9 Setup Defaults
Esc Exit
Select Menu
Enter Select Sub-Menu F10 Save and Exit
8
Page 58
A-1
SCSI BIOS Setup
This chapter provides information on the Small Computer Sys­tem Interface (SCSI) BIOS setup utility and allows you to configure the SCSI subsystem for optimum use.
You may need to run the SCSI BIOS setup utility when: You want to change the default SCSI controller settings for cus-
tomized features.
You intend to manage any of the attached SCSI devices.
Appendix A: SCSI BIOS Setup (Optional)
Page 59
A-2
MS-9136 SSI Server Board
Entering SCSI BIOS
Control Keys
Use the following keys to navigate the SCSI BIOS menu items.
Selecting the SCSI Channel
After entering the SCSI BIOS by pressing the <Ctrl> + <A> key combination, you will see the following menu appear on the screen.
Each item represents one SCSI channel (connector). The mainboard offers dual onboard SCSI channels: channel A & channel B. Move the cursor to the desired channel and then press <Enter>.
Selecting the Management Type
The following screen will appear after you select the SCSI channel you intend to manage. The menu will list two categories for you to choose what to do with the SCSI channel. Move the cursor to the desired function and press <Enter>.
Power on the computer and the system will start POST (Power On Self Test) process. When the message below appears on the screen, press <Ctrl> + <A> keys simulta­neously to enter SCSI BIOS utility.
YYY Press <Ctrl><A> for SCSISelect(TM) Utility ZZZ
<↑> <↓> <←> <→>
Move be tween different items
<Enter> Select the item or show the options of the
selected item
<Esc> Exit the menu or return to the main menu from
a submenu
<F6> Restore the default SCSI values
AIC-7902 A at slot 0A 03:07:00
AIC-7902 B at slot 0A 03:07:01
Page 60
A-3
SCSI BIOS Setup
Configure/View SCSI Controller Settings
Use this option for SCSI controller configurations.
SCSI Disk Utilities
Use this option to manage the attached SCSI device.
Would you like to configure the SCSI controller, or run the SCSI Disk Utilities? Select the option and press <Enter>.
Configure/View SCSI Controller Settings
SCSI Disk Utilities
Options
AIC-7902 A at slot 0A, 03:07:00
Page 61
A-4
MS-9136 SSI Server Board
Configure/View SCSI Controller Settings
SCSI Bus Interface Definitions
SCSI Controller ID
The item is used to assign a SCSI ID to the SCSI controller. It is recommended that you should leave the default setting unchanged. Settings: [0]~[15].
SCSI Controller Parity
Use the field to enable or disable SCSI parity error checking function. If any of your SCSI devices does not support parity checking, disable this function. While disabling the function, you should disable disconnections for all devices, as parity checking for the reselection phase is NOT disabled. A non-parity device’s I/O operation will never complete if the reselection fails due to a parity error.
SCSI Controller Termination
In order to have the SCSI bus function properly and reliably, termination at the ends of
There are 8 items in the “Configure/View SCSI Controller Settings” screen. These items display or allow you to change the SCSI controller’s settings. Use the arrow keys to highlight the item and then press <Enter> to select the value you want in each item or enter each item’s sub-menu screen.
AIC-7902 A at slot 0D, 03:07:00
SCSI Bus Interface Definitions
SCSI Controller ID ................................... 7
SCSI Controller Parity .............................. Enabled
SCSI Controller Termination ................... Enabled
Additional Options
Boot Device Configuration ...................... Press <Enter>
SCSI Device Configuration ...................... Press <Enter>
Advanced Configuration .......................... Press <Enter>
<F6> -- Reset to SCSI Controller Defaults
Options
Interrupt (IRQ) Channel ........................... 11
I/O Port Address........................................ B000h, B400h
BIOS Information
Page 62
A-5
SCSI BIOS Setup
the SCSI bus is necessary. Proper termination can ensure signal on the SCSI bus will not reflect and cause data loss or errors. Settings options: [Enabled], [Disabled].
Additional Options
Boot Device Configuration
Press <Enter> to enter the sub-menu screen.
Boot SCSI Controllers
Select either SCSI channel A (AIC-7902 A) or channel B (AIC-7902 B) to boot up the SCSI subsystem.
Boot SCSI ID
Specify a SCSI device to become the boot device by selecting its SCSI ID. Setting options: [0]~[15].
Boot LUN Number
If a boot device has multiple logical units, you must specify the boot logical unit number (LUN). If multiple LUN support is disabled, specifying a number here is useless. Setting options: [0]~[7].
SCSI Device Configuration
Press <Enter> and the following sub-menu screen appears. The sub-menu screen allows you to specify the configuration for each device on the SCSI bus.
Single Image
Master SCSI Controller..................... AIC-7902 A at slot 0A 03:07:00
Select SCSI peripheral from which to boot
Boot SCSI Controller......................... AIC-7902 A at slot 0A 03:07:00
Boot SCSI ID....................................... 0
Boot LUN Number............................0
Boot Device Configuration
Option Listed Below Has NO EFFECT if MULTI LUN Support is Disabled
Page 63
A-6
MS-9136 SSI Server Board
Sync Transfer Rate (MB/Sec)
The field allows you to specify the maximum synchronous data transfer rate depending on the type of each SCSI device. Select [ASYN] to enable asynchro­nous negotiation for some older SCSI devices.
Packetized
When enabled, this option is supported by the device drivers. However, this option is not supported by the BIOS.
QAS
When enabled, this option is supported by the device drivers. However, this option is not supported by the BIOS.
Initiate Wide Negotiation
When set to [Yes], the field allows wide SCSI hard drives to use 16-bit (2 bytes) transfers.
Enable Disconnection
This field tells the SCSI controller whether or not to allow the specified SCSI device to disconnect during an I/O transfer operation. The disconnection ability frees the SCSI bus to allow other I/O processes and thus optimizes the SCSI bus performance. Setting options: [Yes], [No].
SCSI Device ID #0 #1 #2 #3 #4 #5 #6 #7
Sync Transfer Rate (MB/Sec) ........ 320 32 0 3 20 32 0 320 3 20 320 320
Packetized......................................... Yes Yes Yes Yes Yes Yes Yes Yes
QAS................................................... Yes Yes Yes Yes Yes Yes Yes Yes
Initiate Wide Negotiation .............. Yes Yes Yes Yes Yes Yes Yes Yes
Enable Disconnection ..................... Yes Yes Yes Yes Yes Yes Yes Yes
Send Start Unit Command............. Yes Yes Yes Yes Yes Yes Yes Yes
BIOS Multiple LUN Support ......... No No No No No No No No
Include in BIOS Scan ...................... Yes Yes Yes Yes Yes Yes Yes Yes
SCSI Device ID #8 #9 #10 #1 1 #12 #13 #14 #15
Sync Transfer Rate (MB/Sec) ........ 320 32 0 3 20 32 0 320 3 20 320 320
Packetized......................................... Yes Yes Yes Yes Yes Yes Yes Yes
QAS................................................... Yes Yes Yes Yes Yes Yes Yes Yes
Initiate Wide Negotiation .............. Yes Yes Yes Yes Yes Yes Yes Yes
Enable Disconnection ..................... Yes Yes Yes Yes Yes Yes Yes Yes
Send Start Unit Command............. Yes Yes Yes Yes Yes Yes Yes Yes
BIOS Multiple LUN Support ......... No No No No No No No No
Include in BIOS Scan ...................... Yes Yes Yes Yes Yes Yes Yes Yes
SCSI Device Configuration
Page 64
A-7
SCSI BIOS Setup
Send Start Unit Command
When set to Yes, the SCSI controller sends the Start Unit command to the specified SCSI device during bootup. The interface powers up the SCSI device on-at-a-time during bootup, reducing the load on the computer’s power supply. Setting options: [Yes], [No].
BIOS Multiple LUN Support
Select [Yes] when any SCSI device has multiple logical units. Setting options: [Yes], [No].
Include in BIOS Scan
Selecting [Yes] allows the SCSI controller to control the SCSI device with its SCSI ID. When set to [No], the SCSI controller does not control the specified SCSI device by not scanning for the SCSI ID during bootup, but the boot time will be decreased. Setting options: [Yes], [No].
Advanced Configuration
Press <Enter> to enter the sub-menu screen for advanced configuration.
Reset SCSI Bus at IC Initialization
Selecting [Enabled] will reset the SCSI bus the first time the SCSI controller is initialized. Setting options: [Enabled], [Disabled].
Display <Ctrl><A> Message During BIOS Initialization
When enabled, the message “Press <Ctrl><A> for SCSISelect(TM) Utility” ap­pears on the screen during bootup. If disabled, the message does not show up, but you can still press <Ctrl> + <A> key combination to enter the SCSI BIOS utility. Setting options: [Enabled], [Disabled].
Extended Int 13 Translation for DOS Drives > 1 GByte
The field allows SCSI hard disk drives greater than 1 GB to use a translation scheme of 255 heads, 63 sectors per track. Setting options: [Enabled], [Disabled].
Reset SCSI Bus at IC Initialization................................................... Enabled
Display <Ctrl><A> Message During BIOS Initialization............ Enabled
Extended Int 13 Translation for DOS Drives > 1 GByte .............. Enabled
POST Display Mode .......................................................................... Verbose
SCSI Controller Int 13 Support ........................................................ Enabled
Domain Validation ............................................................................ Enabled
Support Removable Disks Under Int 13 as Fixed Disks .............. Disabled
BIOS Support for Bootable CD-ROM.............................................. Enabled
Advanced Configuration
Option Listed Below Has NO EFFECT if MULTI LUN Support is Disabled
Page 65
A-8
MS-9136 SSI Server Board
POST Display Mode
The field determines how much information about your SCSI controller and devices appear on the screen during bootup. For the most complete information, choose [Diagnostic]. For a faster boot, select [Silent]. Setting options: [Verbose], [Silent], [Diagnostic].
SCSI Controller Int 13 Support
The field allows you to enable or disable the support for Int 13h. The software interrupt “Int 13h” is the interface through which the operating system or appli­cation is able to pass commands to hard disk drives, such as reading, writing and formatting. Setting options: [Enabled], [Disabled: NOT scan], [Disabled: scan bus].
Domain Validation
When enabled, these options are available if they are implemented in the device drivers. However, this option is not supported by the BIOS.
Support Removable Disks Under Int13 as Fixed Disks
When [Boot Only] is selected, only the removable media drive designated as the boot device will be treated as a hard disk drive. When [All Disks] is selected, all removable media drives supported by the BIOS are treated as hard disk drives. If selecting [Disabled], no removable media drive is treated as a hard disk drive and the removable media drives must be controlled by the OS drivers.
BIOS Support for Bootable CD-ROM
When enabled, the SCSI controller BIOS supports bootable CD-ROM under the El Torito specification. If booting from a hard disk or other device, make sure no bootable CD-ROM is inserted or disable this option.
BIOS Information
Interrupt (IRQ) Channel
Displays the IRQ line assigned to the SCSI channel.
I/O Port Address
Displays the I/O port address assigned to the SCSI channel.
Page 66
A-9
SCSI BIOS Setup
Disk Utilities
AIC-7902 A at slot 0A, 03:07:00
SCSI ID#0: No device SCSI ID#1: No device SCSI ID#2: No device SCSI ID#3: No device SCSI ID#4: No device SCSI ID#5: No device SCSI ID#6: No device SCSI ID#7: Adaptec AIC-7902 SCSI ID#8: No device SCSI ID#9: No device SCSI ID#10: No device SCSI ID#11: No device SCSI ID#12: No device SCSI ID#13: No device SCSI ID#14: No device SCSI ID#15: No device
Select SCSI Disk and press <Enter>
AIC-7902 B at slot 0A, 03:07:00
SCSI ID#0: HITACHI DK32DJ-18MW SCSI ID#1: No device SCSI ID#2: No device SCSI ID#3: No device SCSI ID#4: No device SCSI ID#5: No device SCSI ID#6: No device SCSI ID#7: Adaptec AIC-7902 SCSI ID#8: No device SCSI ID#9: No device SCSI ID#10: No device SCSI ID#11: No device SCSI ID#12: No device SCSI ID#13: No device SCSI ID#14: No device SCSI ID#15: No device
Select SCSI Disk and press <Enter>
Page 67
A-10
MS-9136 SSI Server Board
Select the SCSI device which you want to manage by highlighting the item and press <Enter>. The following dialog box appears. Select the function you want to perform.
Format Disk
The utility performs low-level formatting of a hard disk drive. The function might take several hours to complete.
Verify Disk Media
This utility verifies that the drive is functioning properly. Verifying function will scan for media defects on the disk.
SCSI ID# 0: HITACHI DK32DJ-18MW Firmware: G2G2 Capacity: 17GB
Format Disk Verify Disk Media
Page 68
B-1
Adaptec SATA RAID Utility for Intel ICH-HR
The southbridge ICH-HR provides a hybrid solution that combines two indepen­dent SATA ports for support of up to two Serial ATA (Serial ATA RAID) drives and utilizes Adaptec Embedded Serial ATA RAID Software to support RAID levels 0 and 1 for easy management of the storage subsystems.
Serial ATA (SATA) is the latest generation of the ATA interface. SATA hard drives deliver blistering transfer speeds of up to 150MB/sec. Serial ATA uses long, thin cables, making it easier to connect your drive and improving the airflow inside your PC.
1. Supports 150 MB/s transfers with CRC error checking
2. Data handling optimizations including tagged command queuing, elevator seek and packet chain command
Appendix B: Adaptec SA T A RAID Utility for Intel ICH-HR
MSI Reminds You...
All the information/volumes listed in your system might differ from the illustrations in this appendix.
Page 69
B-2
MS-9136 SSI Server Board
Introduction
1. Overview
Adaptec Embedded Serial ATA RAID with HostRAIDTM adds RAID functionality to the Serial ATA I/O controller by supporting RAID levels 0 and 1. HostRAID adds entry level RAID support to the Serial ATA I/O controller. With HostRAID, you can add reliable performance and full data protection.
2. Operating System Compatibility
Microsoft
®
Windows® 2000, Windows® Server 2003, and Windows® XP
Linux
- Red Hat 7.3 and 8.0
- SuSE 8.0 and 8.1
3. Storage Requirements
Device drivers and storage management software require approximately 20 MB of disk space.
4. Features
Adaptec Embedded Serial ATA RAID Software RAID supports:
RAID levels 0, 1, and simple volume using Adaptec’s HostRAID technology.Operating system independent configuration and RAID creation using Adaptec
RAID Configuration (ARC).
Easy array configuration and status using Adaptec Storage Manager
TM
Browser Edition. Install Adaptec Storage Manager – Browser Edition as described in Installing Adaptec Storage Manager – Browser Edition.
Event logging and broadcasting, including messaging for alphanumeric pagers.
5. Storage Management Software Overview
Adaptec Embedded Serial ATA RAID includes the following software tools to manage your storage subsystem:
Adaptec Storage Manager – Browser Edition—Browser-based stor-
age management software that provides all of the creation, management, and data logging needed to manage arrays. Arrays may be set up and managed on systems using the following operat­ing systems:
Windows 2000, Windows Server 2003, and Windows XP
Red Hat Linux 7.3 and 8.0
SuSE Linux 8.0 and 8.1
Page 70
B-3
Adaptec SATA RAID Utility for Intel ICH-HR
Adaptec RAID Configuration (ARC) Utility—Part of the controller ’s built-in
BIOS code. Y ou start ARC by pressing Ctrl+A during BIOS startup. For details, see Adaptec RAID Configuration Utility.
Array Configuration Utility (ACU)—A DOS/BIOS application used to create,
configure, and manage arrays. For details, see Adaptec RAID Configuration Utility.
Page 71
B-4
MS-9136 SSI Server Board
Installing the Driver
This section describes installing the driver and setting up the new array for the drives attached to your controller. Before you get started, you need to select from the following scenarios for installing the controller driver on Windows or Linux systems:
Installing the Driver in a New Windows System Installing the Driver in an Existing Windows System Installing Red Hat Linux 7.3 or 8.0 Installing SuSE Linux 8.0 or 8.1
1. Installing the Driver in a New Windows System
In this scenario, you are installing the driver in a new system that has no operat­ing system. To install the driver:
1. Create a driver disk by following the instructions from the Web site or the product CD.
2. Restart the computer.
3. If creating an array, press Ctrl-A when prompted to enter the ARC utility.
For instructions on creating an array from the BIOS, see Adaptec RAID Configuration Utility. For a simple volume, skip to Step 4.
4. When the array is finished building or if you are continuing from Step 3, insert the Windows setup CD and restart the system.
5. Press F6 when prompted to install a third-party driver.
6. Insert the driver disk you created in Step 1 and wait until prompted to install
a driver.
7. Press S to specify that the driver is on the floppy disk, and press Enter. Windows searches the disk for a suitable driver.
8. When the Adaptec Embedded Serial ATA HostRAID driver is found, press Enter. Follow the remaining on-screen instructions to complete your
installation.
MSI Reminds You...
When F6 is active, a prompt appears at the bottom of the screen. Press F6 immediately — you only have 5 seconds. If you miss your chance, restart this Windows installation to complete it correctly. Otherwise, Windows will not recognize your controller.
Page 72
B-5
Adaptec SATA RAID Utility for Intel ICH-HR
2. Installing the Driver in an Existing Windows System
In this scenario, you are installing a driver in a system that already has a Win­dows operating system. To install the driver:
1. Create a driver disk by following the instructions from the Web site or the product CD.
2. Start Windows. Windows launches the Found New Hardware Wizard, which searches for the controller driver.
3. Insert the driver disk you created in Step 1. Select the floppy disk drive as the source and click Next.
4. If necessary, select the appropriate driver for your operating system.
5. Click Next as needed to complete the controller installation.
6. Remove the driver disk.
7. If prompted, restart the computer.
8. Your installation is complete. If you want to create an array from the BIOS,
see Adaptec RAID Configuration Utility. If you want to create an array from the operating system, see Using Adaptec Storage Manager – Browser Edition.
3. Installing Red Hat Linux 7.3 or 8.0


Installing the Red Hat Driver in a New Linux System
In this scenario, you are installing the driver in a new Linux system. To install the driver:
1. Obtain a driver disk from either the Web site or the product CD.
2. Restart the computer.
3. If creating an array, press Ctrl-A when prompted to enter the ARC utility.
For instructions on creating an array from the BIOS, see Adaptec RAID Configuration Utility. For a simple volume, skip to Step 4.
4. When the array is finished building, or if you are continuing from Step 3, insert the Red Hat CD Disk 1 in the CD-ROM drive and restart the system.
5. When the Red Hat Welcome screen appears, type expert or linux dd at the boot prompt.
6. When prompted, insert the driver disk (see Step 1) and select OK.
7. Follow the prompts to set up your preferred environment.
8. If you intend to install other third-party devices, proceed with the installa- tion of those devices. Otherwise, select Done.
9. Continue with the Linux installation according to the Red Hat documentation.


Installing or Updating the Driver in an Existing Linux System
To install the driver in an existing Linux system, type:
rpm -Uvh xxx.yyy.rpm
To update the driver in an existing Linux system, type:
rpm -Uvh —force xxx.yyy.rpm
where xxx is the name of the driver file and yyy is the processor type.
Page 73
B-6
MS-9136 SSI Server Board
4. Installing SuSE Linux 8.0 or 8.1


Installing the Driver in a New Linux System
In this scenario, you are installing the driver in a new Linux system. To install the driver:
1. Obtain a driver disk from either the Web site or the product CD.
2. Restart the computer.
3. If creating an array, press Ctrl-A when prompted to enter the ARC utility.
For instructions on creating an array from the BIOS, see Adaptec RAID Configuration Utility. For a simple volume, skip to Step 4.
4. When the array is finished building, or if you are continuing from Step 3, insert the SuSE CD Disk 1 in the CD-ROM drive and restart the system.
5. When the SuSE Installation menu appears, press the Alt key, then select one option from the Menu and press Enter.
6. When prompted, insert the driver disk you created (see Step 1) and press any key to continue.
7. Follow the prompts to set up your preferred environment.
8. Continue with the Linux installation according to the SuSE documentation.
9. When the SuSE Menu appears:


For SuSE 8.0 — type acpi=off at the boot options, then press Enter.


For SuSE 8.1 — type noapic at the boot options, then press Enter .
10. When the Linux installation is complete:


For SuSE 8.0 — edit the /etc/lilo.conf file by removing:
append=”acpismp=force” Run the /sbin/lilo command to update the LILO.


For SuSE 8.1 — go to the scrip file by typing:
edit/boot/grub/menu.lst Type noapic after vga=xxx as in this example: Kernel(hd0,0)/vmlinux root=/dev/hdc3 vga=791 noapic


Installing or Updating the Driver in an Existing Linux System
To install the driver in an existing Linux system, type:
rpm -Uvh xxx.yyy.rpm
To update the driver in an existing Linux system, type:
rpm -Uvh —force xxx.yyy.rpm
where xxx is the name of the driver file and yyy is the processor type.
Page 74
B-7
Adaptec SATA RAID Utility for Intel ICH-HR
Installing Adaptec Storage Manager – Browser Edition
1. Overview
This chapter discusses the installation procedure for installing Adaptec Storage Manager – Browser Edition to enable remote and local management of arrays.
2. Supported Browsers
To run Adaptec Storage Manager – Browser Edition, your computer must have a Web browser supporting JavaScript and cookies only. The following versions are supported:
On Windows
- Internet Explorer (IE) 5.0 or later
- Netscape 7 or later
On Linux
- Adaptec-supplied and installed version of Mozilla
- Netscape 7 or later
When using Adaptec Storage Manager, you need to log on to your system with administrator privileges.
3. Typical, Custom, and Compact Installations
You can select from these setup options:
Typical (default) — Supports local and remote management; however,
Adaptec SNMP is not included.
Custom — For expert users. Primarily used on Web servers or when you
want to make sure SNMP and Notifier are available for a managed system. You can select from these components:
* Managed System Components — If you choose this selection only,
the installation is the same as a Compact installation.
* Adaptec Web Server — Installs components allowing managed systems
to communicate with Web browsers.
* Adaptec Storage Manager Notifier — Installs messaging, including
email and broadcaster capabilities.
* Adaptec SNMP — Installs components used by SNMP-based applications.
Requires Microsoft SNMP agents to be installed to function. Not included in a Typical installation.
Compact — Installs only the components required on a remotely managed
system. See Managed System Components, above.
MSI Reminds You...
When you perform a T ypical or Compact installation, components needed for communication and remote management are installed automatically.
Page 75
B-8
MS-9136 SSI Server Board
4. Installing Adaptec Storage Manager on Windows
To install Adaptec Storage Manager – Browser Edition:
1. Verify that a supported browser is installed. See Supported Browsers for details.
2. Insert the product installation CD and wait for the Autorun executable to start the installation. If this does not occur, browse the CD and click
Autorun.
3. Click Adaptec Utilities.
4. Click Install Adaptec Storage Manager.
5. Click Next in the Install Shield window.
6. Read the license agreement. If you agree to its terms, click Yes. If not, click No and terminate the installation. The Select a Setup T ype window appears.
It provides three types of installations: Typical, Compact, and Custom. See Typical, Custom, and Compact Installations for details.
7. Choose a setup type and click Next.
8. When you see the Destination Folder, click Next.
9. When you see the Setup Information, click Next. The Setup Status window
shows progress using a scroll bar. Before the scroll bar shows the instal­lation is completed, another window pops up indicating that a security certificate has been generated.
10. Click OK. The Root Certificate Store window appears.
11. Click Yes. The security certificate generated during installation is added to
the Certificate Store. If you click No at this point, you will need to install the certificate the first time you run Adaptec Storage Manager.
12. When prompted to restart your computer, accept the default (Yes) and
click Finish.
13. The system restarts to complete the installation.
14. Remove the product installation CD before the system restarts; otherwise,
the installation will start again.
MSI Reminds You...
When installing on a FAT 32 file system, the folder being installed is automatically hidden.
Page 76
B-9
Adaptec SATA RAID Utility for Intel ICH-HR


Configuring Internet Browsers on Windows
If you are managing a local storage array and your computer uses a proxy server, you need to configure your browser to enable Adaptec Storage Manager to bypass the proxy server. Also, if you are managing remote systems, you need to configure Adaptec Storage Manager to bypass the proxy server when commu­nicating with these systems.
The following procedures are described in this section:  Configuring Internet Explorer for Local Management Configuring Internet Explorer for Remote Management Configuring Netscape Navigator for Local Management Configuring Netscape Navigator for Remote Management
Configuring Internet Explorer for Local Management
When using the High security setting, you must enable the following settings
manually:
JavaScript
Cookies (not stored)
You do not need to enable the following custom level security settings for the
local Intranet in Internet Explorer 5 and 5.5. Select Tools > Internet Options to
access these settings:
Active Scripting
Allow per session cookies (not stored)
If you are using a proxy server to access the Internet, you must bypass the proxy
server to access the Adaptec Storage Manager Web server. To verify whether
you are using a proxy server:
1. From the Internet Option window, click the Connections tab.
2. Click LAN Settings.
If the Use a proxy server box isn ’t checked, exit by clicking OK. You
aren’t using a proxy server, so ignore this setting.
If the Use a proxy server box is checked, make sure the Bypass proxy
server for local addresses box is also checked. Then, click the Advanced button. In the Exceptions window, enter localhost as an
entry. You are now ready to proceed to Using Adaptec Storage Manager – Browser Edition.
Configuring Internet Explorer for Remote Management If you know the IP address of the system you want to manage remotely:
1. Choose Tools > Internet Options > Connections > LAN Settings.
2. Select Use a proxy server for your LAN > Advanced.
3. In the Exceptions section, type the managed system’s IP address.
MSI Reminds You...
In Internet Explorer 6.0 there is no security setting for cookies. Cookie configuration was removed from the Privacy tab. There is no setting for blocking Intranet cookies.
Page 77
B-10
MS-9136 SSI Server Board
Configuring Netscape Navigator for Local Management
To configure Netscape Navigator:
1. Log in to your computer with administrator access.
2. Select Edit > Preferences .
3. In the Preferences window, click the right arrow on the Privacy and Secu- rity line. Ensure that one of the Enable cookies options is selected.
4. Select the Advanced line. Ensure that Enable Javascript for Navigator
is checked.
5. Exit Navigator, then restart it. This enables any settings you have modified.
6. You are now ready to proceed to Using Adaptec Storage Manager –
Browser Edition.
Configuring Netscape Navigator for Remote Management
If you know the IP address of the system you want to manage remotely:
1. Choose Edit> Preferences > Advanced> Proxies > Manual proxy configuration > No Proxy For.
2. Type the managed system’s IP address.
MSI Reminds You...
These instructions apply specifically to version 7 and may differ in later versions.
Page 78
B-11
Adaptec SATA RAID Utility for Intel ICH-HR
5. Installing Adaptec Storage Manager on Linux
To install Adaptec Storage Manager on a Linux computer and configure the de­sired Internet browser:
1. Insert the product installation CD.
2. Install the software by typing:
sh <mount-point>/install.sh.
The <mount-point> differs among computers, but /mnt/cdrom, /media/ cdrom, or cdrom usually works. A Welcome window appears.
3. Click Next. The License Agreement window appears.
4. Read the license agreement. If you agree to its terms, click Accept. If not,
click Cancel and terminate the installation. The Choose Setup Type win­dow appears. It provides three types of installations: Typical, Compact, and Custom. See Typical, Custom, and Compact Installations for details.
5. Choose a setup type and click Next. The Start Copying window appears.
6. Click Next. The Running Non-Interactive Setup window displays the files
being loaded onto the system.
7. Click Next when prompted. A Setup Complete window appears.
8. Click Complete. A message window appears reminding you that any
proxy servers must be bypassed for the RAID management application to work. Installing Adaptec Storage Manager – Browser Edition
9. Click OK. The Shell window you used to launch the installation indicates that some daemons are being started. The installation creates a shortcut to Adaptec Storage Manager in the System tab. This shortcut launches Adaptec Storage Manager using Mozilla. Unless the controller driver was installed as part of this installation, you do not need to restart your computer.
10. Remove the product installation CD. Your computer must have a Web browser supporting JavaScript and cookies. To use Adaptec Storage Manager, you need to log on to your computer with root privileges.
MSI Reminds You...
When performing this installation, keep in mind that Linux is case sensitive.
Page 79
B-12
MS-9136 SSI Server Board
Using Adaptec Storage Manager – Browser Edition
1. Overview
This section describes how to use Adaptec Storage Manager – Browser Edition to manage arrays. Once you are logged in, you will find convenient online help to guide you through the details of creating, configuring, and managing arrays.
With Adaptec Storage Manager, you can:
Locally manage a system containing a supported Adaptec RAID controller that
has Windows or Linux and a supported browser.
Remotely manage any system containing a supported Adaptec RAID control-
ler that has Managed System Components (see Typical, Custom, and Com­pact Installations). You can manage a system remotely from a system that
does not contain a RAID controller.
These same Windows and Linux systems can also be managed remotely by either of these methods:
Installing Adaptec Storage Manager on the remote system.Directing the browser on the remote system to the system you want to
manage.
MSI Reminds You...
Your controller may not support all of the features described. In most cases if a feature is not supported by your controller the feature does not appear in the interface.
MSI Reminds You...
To manage an array remotely from a Linux system, install Adaptec Stor­age Manager on the system and use the Adaptec-supplied version of Mozilla as the browser.
Page 80
B-13
Adaptec SATA RAID Utility for Intel ICH-HR
2. Architecture Overview
A locally managed system requires all of these components:
A supported Web browser, which should already be installed on the system.The Adaptec Web service which supplies content displayed on the Web
browser.
An Adaptec-supplied storage agent.
A remotely managed system requires all of these components:
The remote system must contain a browser.The storage agent must always be installed on the system with the RAID
controller installed.
Remote and managed systems must have a TCP/IP connection.
The Web service can be installed on the same remote system as the browser, the system with the RAID controller installed, or a third system.
Communication security is ensured because Secure-HTTP (S-HTTP) or SSL pro­tocols are used to encrypt all transmitted data. Connection over an Ethernet network, a corporate WAN, or VPN are supported.
3. Logging In
To login:
1. Start Adaptec Storage Manager – Browser Edition.
In Windows, click Start > Programs > Adaptec Storage Manager >
Adaptec Storage Manager – Browser Edition.
In Linux, click Start > System > Adaptec Storage Manager. The Login
screen appears.
2. Enter the host name or IP address of the system you want to manage and the username and password you would use to log into that system.
3. Click Login.
Page 81
B-14
MS-9136 SSI Server Board
Notes: When running Adaptec Storage Manager for the first time:
You need to install a security certificate if you chose not to during the instal-
lation process. For instructions see Installing a Security Certificate.
You are asked to register your software. For instructions see Registering
Your Software.
To log in from any system with a Web browser:
1. Start the Web browser application and type the IP address for the system you
want to access in the address bar and press Enter. For example, https://10.
6.3.14:3513/adaptec. When connection to the remote system is established, the System Login screen appears.
2. Enter the host name or IP address of the system you want to manage and the
administrative username and password that you would normally use to log into that system.
3. Click Login.
4. Installing a Security Certificate
If you chose not to install a security certificate when you installed Adaptec Storage Manager – Browser Edition, you must install the certificate when you run the application for the first time.
To create the certificate:
1. When the Security Alert window appears, click View Certificate.
2. On the Certificate window, click Install Certificate.
3. On the Certificate Import wizard window, click Next. The Certificate Import
wizard window’s contents change.
4. Accept the default, Automatically select the certificate store, and click Next.
5. On the root Certificate Store window, click Yes. Another small Certificate Import wizard window appears.
6. Click OK. The Certificate window mentioned in Step 2 reappears.
7. Click OK. You are returned to the Security Alert window from Step 1.
8. Click Yes to finish the creation and storage of the certificate.
5. Registering Your Software
After installing and creating a security certificate, you are asked to register the product. If you want click Register Now, your computer must have an Internet connection. If you need to delay registration, click Register Later. If you choose Register Later, you will be prompted to register the application the next time you run it.
MSI Reminds You...
If you are using a proxy server to access the Internet, you must bypass the proxy server to access the Adaptec Storage Manager Web server. See Configuring Internet Browsers on Windows for details.
Page 82
B-15
Adaptec SATA RAID Utility for Intel ICH-HR
6. The Basics
An example of a typical Adaptec Storage Manager – Browser Edition screen is shown below.
The action buttons are:
Logout — Selecting Logout ends your session and returns you to the
Login screen.
Rescan — Used to rescan the configuration of the system. Typically,
when a rescan is required, it occurs automatically, for example, after an array is created. However, the system configuration can change without Adaptec Storage Manager being notified. For example, drives that are inserted or removed from a nonintelligent enclosure or an enclosure powered on after you logged into Adaptec Storage Manager would not be displayed unless you manually rescan.
The remaining buttons open additional windows that provide more detailed infor­mation and allow you to perform actions or change settings on a specific aspect of your storage subsystem. These are:
Events
Options
Help
Properties
Tasks
Immediately following the header frame is a controller information line including the model number of the first Adaptec RAID controller found in the system and the amount of cache memory (if any) installed on that controller.
Beneath the controller information are Physical Devices and Logical Devices views that show connected devices and existing arrays on this controller. Con­troller information and device views are repeated for each additional Adaptec RAID controller in the system.
Select the controller by clicking anywhere on the controller information. When the controller is selected, the Events, Properties and Tasks buttons change from blue
MSI Reminds You...
Depending on your operating system, browser, and color scheme you may notice some differences between this illustration and your screen.
Page 83
B-16
MS-9136 SSI Server Board
to amber, indicating that clicking any of them will display an additional window with information and options specific to this controller.


Pop-Up Tool Tips
If you position the cursor over a device or button a pop-up tool tip appears. For buttons, the tips contain helpful information about the function of the button, while for devices they display additional information.


Physical Devices
The Physical Devices view displays information about the drives and enclosures attached to the Adaptec RAID controller. The devices are shown organized by the channel or port that they are connected to and shown in numerical order.
The display for each channel includes information on maximum speed capability, the number of the channel on the controller, and the number of devices found (excluding the SCSI controller).
Selecting a channel or device will turn the Events, Properties, and Tasks buttons amber. This indicates that clicking any of these buttons will display an additional window with information and options specific to that device or channel.
At the top of the Physical Devices view, grouped to the right of View, are three view selection buttons. These buttons select the physical devices connected to this controller.
Changing How Drives are Displayed By default, the Physical Devices displays a condensed view of the controller configuration that hides detailed information about the drives. More information is available by either positioning the mouse pointer over the device or clicking on the arrowhead to the left of a row of devices.
The selected display mode button will appear in a lighter shade of blue than the other two buttons. The default display is the Text Description View, but in the condensed view used when Adaptec Storage Manager is loaded, the display is the same in all three modes.
If you change the display mode by selecting one of the other view buttons, a yellow arrow flashes to the left of any devices where the condensed display prevents omits information.
An icon is always the first entry on each device line. The icon is used to represent a hard disk drive. If a + symbol appears with the hard disk drive icon
, the drive is a hot spare. Different icons are used to represent other devices.
Page 84
B-17
Adaptec SATA RAID Utility for Intel ICH-HR
View
is the default display mode and when expanded, will show the following
information about each device:
Capacity of the drive
Drive manufacturer and model number
SCSI drive ID, or Serial ATA port number
When expanded, the Full Size Capacity View button and the Relative Size Capacity View button represent each drive as a bar. A drive that is not used as
part of any array is shaded blue surrounded by a dotted line.
displays a full-length bar for each drive, regardless of capacity. displays a bar for each drive, with the largest capacity drive full-length and
the other drives proportional to the drive capacity, relative to the largest drive. Any part of a drive used in an array is shown as a gray segment within the bar.
Selecting any gray segment will highlight it in amber and, in the Logical Devices view, highlight the array of which this segment is a member.
In either the Full Size Capacity View or the Relative Size Capacity View, a small portion at each end of the drive may be shown in dark gray.
The segment at the end of the drive may vary in size from drive to drive because, in addition to the RAID signature, the controller may also limit the usable capacity of each drive.
This is done because hard disk drives of apparently the same capacity from different manufacturers, or even different models from the same manufacturer, actually vary slightly in the true capacity available. Although, in normal operation this is not an issue, it can be when assigning hot spares or replacing a failed drive.
If the controller used the maximum capacity of each drive and a hot spare or replacement drive was just a few megabytes smaller, it would not be able to replace the failed drive. By rounding drive capacities down to the nearest 2 MB, this possibility is effectively eliminated.


Logical Devices
As described earlier, when Adaptec Storage Manager loads, the Logical Devices view is expanded and you can see the arrays present on the controller.
At the top of this view are the following buttons: Create, Modify, and Delete. Each button opens a wizard for the corresponding function.
Modify allows you to:


Change an array from one RAID level to another


Expand an array


Change the stripe size for a RAID 0
Page 85
B-18
MS-9136 SSI Server Board
For detailed instructions on using these buttons, refer to the online Help. The main area of the Logical Devices view is used to display the arrays on this
controller. It defaults to a condensed view of top-level arrays.
In this condensed view, the RAID level of each device as well as whether it is protected by a hot spare, is visible.
If a global hot spare exists, all arrays that the hot spare is large enough to protect will show as protected.
In the expanded view, the icons for the arrays are arranged vertically and along­side them are the capacity, name, and type of array.
Selecting an array by clicking on it will highlight the following in amber:


All the drives or segments that form the array in the Physical Devices
view.


The Events, Properties, and Tasks buttons in the header frame. Se-
lecting any of these three buttons displays a new window with addi­tional information and options specific to that array.
MSI Reminds You...
For Windows Server 2003 only—to see animated icons on Adaptec Storage Manager - logical devices, go to Internet Explorer Proper-
ties/Advanced/Multimedia, and check Play animations in Web Pages option.
MSI Reminds You...
The Options button allows you to display second-level arrays if your controller supports them.
Page 86
B-19
Adaptec SATA RAID Utility for Intel ICH-HR
The Adaptec RAID Configuration (ARC) utility is an embedded BIOS utility that includes:
Array Configuration Utility (ACU)—Used to create, configure, and man-
age arrays.
Disk Utilities —Used to format or verify disks.
To run ARC, press Ctrl+A when prompted by the following message during the system startup:
Press <Ctrl><A> for Adaptec RAID Configuration Utility
The ARC menu appears, presenting these options:
Array Configuration Utility (ACU)
Disk utilities
To select an option from this menu, or from any of the menus within ARC, browse with the arrow keys and then press Enter. In some cases, selecting an option displays another menu. To return to the previous menu at any time, press Esc.
1. Using the Array Configuration Utility
The Array Configuration Utility (ACU) enables you to create, manage, and delete arrays from the controller’s BIOS, and initialize drives.


Managing Arrays
Use the Manage Arrays option to view array properties and members, and delete arrays. The following sections describe these operations in greater detail.
Viewing Array Properties To view the properties of an existing array:
1. At the BIOS prompt, press Ctrl+A.
2. From the ARC menu, select Array Configuration Utility (ACU).
3. From the ACU menu, select Manage Arrays.
4. From the List of Arrays dialog box, select the array you want to view and press Enter. The Array Properties dialog box appears, showing detailed information
on the array. The physical disks associated with the array are displayed here.
5. Press Esc to return to the previous menu.
Deleting Arrays
To delete an existing array:
1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility.
2. From the ARC menu, select Array Configuration Utility (ACU).
MSI Reminds You...
Back up the data on an array before you delete it. Otherwise, all data on the array is lost. Deleted arrays cannot be restored.
Adaptec RAID Configuration Utility
Page 87
B-20
MS-9136 SSI Server Board
3. From the ACU menu, select Manage Arrays.
4. Select the array you wish to delete and press Delete.
5. In the Array Properties dialog box, select Delete and press Enter. The follow-
ing prompt is displayed: Warning!! Deleting the array will render array unusable. Do you want to delete the array?(Yes/No): RAID 1 only—the following prompt is also displayed: Deleting the partition will result in data loss! Do you also want to delete the partition? (Yes/No):
6. Press Yes to delete the array or partition or No to return to the previous menu.
7. Press Esc to return to the previous menu.


Creating Arrays
Before creating arrays, make sure the disks for the array are connected and installed in your system. Note that disks with no usable space, or disks that are uninitialized are shown in gray and cannot be used. See Initializing Disk Drives.
To create an array:
1. Turn on your computer and press Ctrl+A when prompted to access the ARC
utility.
2. From the ARC menu, select Array Configuration Utility (ACU).
3. From the ACU menu, select Create Array.
4. Select the disks for the new array and press Insert . To deselect any disk,
highlight the disk and press Delete.
5. Press Enter when both disks for the new array are selected. The Array
Properties menu displays.
Assigning Array Properties
To assign properties to the new array:
1. In the Array Properties menu, select an array type and press Enter. Note that only the available array types, RAID 0 and RAID 1, are displayed. Each of these types requires two drives.
2. Type in an optional label for the array and press Enter.
3. For RAID 0, select the desired stripe size. Available stripe sizes are 16, 32, and
64 KB (default).
MSI Reminds You...
Once the array is created and its properties are assigned, you cannot change the array properties using the ACU. Instead, use Adaptec Stor­age Manager - Browser Edition.
MSI Reminds You...
Adaptec recommends that you do not change the default.
Page 88
B-21
Adaptec SATA RAID Utility for Intel ICH-HR
4. Create RAID via allows you to select between the different creation methods for RAID 0 and RAID 1. The following table gives examples of when each is appropriate.
Notes:


Before adding a new drive to an array, back up any data contained on the
new drive. Otherwise, all data will be lost.


If you stop the Build or Clear process on a RAID 1 from ACU you can only
restart it from Adaptec Storage Manager - Browser Edition. (See Chapter 4 for details.)


A RAID 1 created using the Quick Init option may return some data
miscompares if you later run a consistency check. This is normal and is not a cause for concern.


The ACU allows you to use drives of different sizes in a RAID 1. During a
build operation however, only the smaller drive can be selected as the source or first drive.


When migrating from single volume to RAID 0, migrating from a larger drive
to a smaller drive is allowed. However the destination drive must be at least half the capacity of the source drive.


Adaptec does not recommend that you migrate or build an array on Win-
dows dynamic disks (volumes), as it will result in data loss.
5. When you are finished, press Done.
MSI Reminds You...
Do not interrupt the creation of a RAID 0 using the Migrate option. If you do, there is no way to restart, and no way to recover the data that was on the source drive.
Page 89
B-22
MS-9136 SSI Server Board


Initializing Disk Drives
If an installed disk does not appear in the disk selection list for creating a new array or if it appears grayed out, you may have to initialize it before you can use it as part of an array. Drives attached to the controller must be initialized before they can be used in an array.
To initialize drives:
1. Turn on your computer and press Ctrl+A when prompted to access the ARC
utility.
2. From the ARC menu, select Array Configuration Utility (ACU).
3. Select Initialize Drives.
4. Use the up and down arrow keys to highlight the disk you wish to initialize and
press Insert.
5. Repeat Step 4 so that both drives to be initialized are selected.
6. Press Enter.
7. Read the warning message and ensure that you have selected the correct disk
drives to initialize. Type Y to continue.
2. Using the Disk Utilities
The Disk Utilities enable you to format or verify the media of your Serial ATA hard disks. To access the disk utilities:
1. Turn on your computer and press Ctrl+A when prompted to access the ARC
utility.
2. From the ARC menu, select Disk Utilities.
3. Select the desired disk and press Enter.
You are offered the following options:


Format Disk—Simulates a low-level format of the hard drive by writing
zeros to the entire disk. Serial ATA drives are low-level formatted at the factory and do not need to be low-level formatted again.


Verify Disk Media—Scans the media of a disk drive for defects.
MSI Reminds You...
Initializing a disk overwrites the partition table on the disk and makes any data on the disk inaccessible. If the drive is used in an array, you may not be able to use the array again. Do not initialize a disk that is part of a boot array. To determine which disks are associated with a particular array, see Viewing Array Properties.
MSI Reminds You...
Formatting destroys all data on the drive. Be sure to back up your data before performing this operation.
Page 90
B-23
Adaptec SATA RAID Utility for Intel ICH-HR
Glossary
A
activity
See task.
ACU
Array Configuration Utility. An application used to create, configure, and manage arrays from the controller’s BIOS or MS-DOS.
array
A logical disk created from available space and made up of one or more segments on one or more physical disks. Arrays are typically used to provide data redundancy or enhanced I/O performance. See also volume, spanned volume, RAID 0, RAID 1. Also known as a container.
array initialization
See initialize.
ATA
AT Bus Attachment. Standard parallel interface to IDE hard disks typically used in desktop computers and some entry-level servers. Serial ATA (SATA), is a successor to parallel ATA, which is sometimes referred to as PATA.
available space/segment
Unused space on an initialized disk from which logical devices (arrays) are created. When an array is deleted, the space that it used is returned to the available space pool.
B
background consistency check
Option that forces the controller to constantly check all portions of disks used by all arrays to see if the disks can return data from the blocks. See also consistency check command.
bad segment
Segment that is in an unknown state.
bootable array
Array configured as the boot device.
build
Background initialization of a redundant array. The array is accessible throughout. RAID 1 copies the contents of the primary drive to a secondary drive. See also clear.
bus
See channel.
Page 91
B-24
MS-9136 SSI Server Board
C
cache
Fast-access memory on the controller that serves as intermediate storage for data that is read from, or written to, drives.
capacity
Total usable space available in megabytes or gigabytes.
channel
Any path, or bus, used for the transfer of data and the control of information be­tween storage devices and a RAID controller. For Serial ATA channels, each channel has a single drive capacity.
chunk
See stripe.
clear
Foreground initialization of a fault-tolerant array. A clear operation zeros all blocks of the array. The array is not accessible until the clear task is complete.
concatenation
Joining of physical or logical drives in sequential order.
consistency check command
Command that reads all the blocks of a RAID 1 to determine if the blocks are consistent. Any inconsistent blocks are fixed.
D
dead partition
See failed.
dedicated hot spare
Component that can take the place of a failed component only on the fault-tolerant array to which it is explicitly assigned.
degraded
A redundant (for example, a RAID 1) array in which one or more members have failed. The data is intact but redundancy has been compromised. Any further failure would cause the array to fail and result in data loss.
disk
Physical disk drive. Randomly accessible, re-writable data storage device. Also called hard disk.
disk ID
Unique disk identifier that consists of the channel number, SATA ID. For example, (channel:ID:LUN) 1:04:0. See also channel.
Page 92
B-25
Adaptec SATA RAID Utility for Intel ICH-HR
drive LED
Disk indicator LED that illuminates during read or write operations.
E
event
Notification or alert from the system, indicating that a change has occurred.
event log
File used to maintain information about prior controller activities or errors.
event notification
Process for transmitting events.
F
failed
State of a nonredundant array that has suffered a single drive failure, or a redundant array that has suffered multiple drive failures. A failed array is inaccessible and data is lost.
fault-tolerant array
Refers to an array that can continue to function after a disk drive failure without loss of data. Fault tolerant, or redundant arrays, include RAID 1 arrays. See also Redundant.
foreign disk
Disk that has previously been initialized on another Adaptec RAID controller. The RAID signature on the disk allows the RAID controller to identify whether or not the disk was initialized on the controller it is currently connected to.
H
hard disk drive
Basic unit of nonvolatile, nonremovable, magnetic storage media. See also disk.
hot swap
To remove a component from a system and install a new component while the power is on and the system is running.
I
impacted
An impacted array is one which has been created but for some reason the initial build operation did not complete. All member drives are present and operational, and all data written to the array is protected. To optimize the array, run a Verify with Fix Task.
initialize
Process of preparing a disk for use by the controller. When a disk is initialized, the controller records the RAID signature on the disk.
Page 93
B-26
MS-9136 SSI Server Board
initialized array
An array that is ready for data reads and writes. Arrays can be initialized by build or clear.
L
legacy disk
Disk that contained a valid partition table when connected to the controller. The controller manages the disk as a legacy disk array where there is a one-to-one logical-to-physical mapping of array to disk.
logical device
Volume comprised of space from one or more physical drives and presented to the operating system as if it were a single storage unit.
low-level format
Process performed by the drive firmware that completely cleans any data off the hard disk.
M
mirrored array/mirroring
See RAID 1.
monitoring
Process of receiving, displaying, and logging system events.
O
offline array
Array that can no longer be accessed.
optimal
The state of an array when it is fully operational. For redundant arrays, the entire array is protected.
P
partition
A section of a disk storage device created by the operating system disk management program, in which data and/or software programs are stored. Computers have a primary operating system partition that contains the special files needed to boot the computer. Each operating system partition is assigned a unique drive letter, such as C or D. A single disk device can have multiple partitions.
phantom object
Object that represents a component that cannot be configured by the controller management software; for example, a missing drive.
Page 94
B-27
Adaptec SATA RAID Utility for Intel ICH-HR
Q
quick init
An array initialized using the Quick Init option is available immediately, with no on­going background controller activity. All data written to an array that has been quick initialized is protected.
R
RAID
Redundant Array of Independent Disks (alternative definition Redundant Array of Inexpensive Disks).
RAID 0
A single-level array consisting of two or more equal-sized segments residing on different disks. RAID 0 distributes data evenly across its respective drives in equal­sized sections called stripes. RAID 0 arrays are not redundant.
RAID 1
Single-level array consisting of two equal segments residing on two different drives. Provides redundancy by storing identical copies on two drives. See also mirrored array/mirroring.
RAID signature
The area on each disk reserved for use by the RAID controller.
RAID volume
Concatenates two or more arrays of the same type.
rebuild
Background regeneration of redundant data on a RAID 1.
redundant
The ability of an array to maintain operability when one or more hardware failures occur. RAID 1 is redundant. In the event of a drive failure, redundant arrays can be restored to normal operation by replacing the failed drive and rebuilding the array.
rescan
Process of updating the current screen to show all currently available resources.
S
Serial ATA (SATA)
A successor to ATA that uses a serial, instead of parallel, interface.
simple volume
A volume made up of disk space from a single disk. It can consist of a single region on a disk or concatenated, multiple regions of the same disk.
Page 95
B-28
MS-9136 SSI Server Board
single-level array
Array created from one or more segments. See also volume, spanned volume, RAID 0, RAID 1.
snapshot
Instantaneous read-only copy of an array at a precise point in time.
spanned volume
A simple volume that spans two or more drives.
stripe
Contiguous set of data distributed across all the disks in an array. A striped array distributes data evenly across all members in equalized sections called stripes.
stripe size
The amount of data in each section of a striped array.
striped array
See RAID 0.
T
task
An operation that occurs only on the RAID controller, asynchronous to all other operations; for example, initializing a disk or verifying an array. Some tasks can take an extended period of time, particularly if the RAID controller is also performing intensive data I/O while the task is running.
V
verify
Low-level check that a drive, logical device, or hot spare is good. In a RAID 1, verify is a low-level check that contents of both members’ segments are consistent and, optionally, corrects errors while assuming that the master drive is correct. In a simple volume, verify performs a low-level check that the whole drive can be read.
volume
See simple volume, spanned volume.
Loading...