Motorola MPX10GP, MPX10GS, MPX10GSX, MPX10D, MPX10DP Datasheet

...

SEMICONDUCTOR TECHNICAL DATA
Order this document
by MPX10/D

     
The MPX10 series device is a silicon piezoresistive pressure sensor providing a very accurate and linear voltage output — directly proportional to the applied pressure. This standard, low cost, uncompensated sensor permits manufacturers to design and add their own external temperature compensating and signal conditioning networks. Compensation techniques are simplified because of the predictability of Motorola’s single element strain gauge design.
Features
Low Cost
Patented Silicon Shear Stress Strain Gauge Design
Ratiometric to Supply Voltage
Easy to Use Chip Carrier Package Options
Differential and Gauge Options
Application Examples
Air Movement Control
Environmental Control Systems
Level Indicators
Leak Detection
Medical Instrumentation
Industrial Controls
Pneumatic Control Systems
Robotics
Figure 1 shows a schematic of the internal circuitry on the stand–alone pressure sensor chip.
PIN 3
+ V
S
PIN 2
+ V
PIN 4
– V
out
out
X–ducer

0 to 10 kPa (0–1.45 psi)
35 mV FULL SCALE SPAN
(TYPICAL)
BASIC CHIP
CARRIER ELEMENT
CASE 344–15, STYLE 1
DIFFERENTIAL
PORT OPTION
CASE 344C–01, STYLE 1
NOTE: Pin 1 is the notched pin.
PIN NUMBER
1
Gnd
2
+V
out
3
V
4
–V
S
out
PIN 1
Figure 1. Uncompensated Pressure Sensor Schematic
VOLTAGE OUTPUT versus APPLIED DIFFERENTIAL PRESSURE
The differential voltage output of the X–ducer is directly proportional to the differential pressure applied.
The output voltage of the differential or gauge sensor increases with increasing pressure applied to the pressure side (P1) relative to the vacuum side (P2). Similarly, output voltage increases as increasing vacuum is applied to the vacuum side (P2) relative to the pressure side (P1).
Senseon and X–ducer are trademarks of Motorola, Inc. REV 5
Motorola, Inc. 1997
1Motorola Sensor Device Data
 
MAXIMUM RATINGS
Rating Symbol Value Unit
Overpressure Burst Pressure Storage Temperature T Operating Temperature T
(8)
(P1 > P2) P
(8)
(P1 > P2) P
max
burst
stg
A
75 kPa
100 kPa –40 to +125 °C –40 to +125 °C
OPERATING CHARACTERISTICS (V
Characteristic
Differential Pressure Range
(5)
(2)
(3)
(6)
(10% to 90%) t
(9)
Supply Voltage Supply Current I Full Scale Span
(4)
Offset Sensitivity V/P 3.5 mV/kPa Linearity Pressure Hysteresis Temperature Hysteresis Temperature Coefficient of Full Scale Span Temperature Coefficient of Offset Temperature Coefficient of Resistance Input Impedance Z Output Impedance Z Response Time Warm–Up 20 ms Offset Stability
(1)
(5)
(0 to 10 kPa) ± 0.1 %V
(5)
(–40°C to +125°C) ± 0.5 %V
(5)
= 3.0 Vdc, TA = 25°C unless otherwise noted, P1 > P2)
S
Symbol Min Typ Max Unit
P
OP
V
S
o
V
FSS
V
off
–1.0 1.0 %V
(5)
(5)
TCV
FSS
TCV
off
TCR 0.21 0.27 %Zin/°C
in
out
R
±0.5 %V
0 10 kPa — 3.0 6.0 Vdc — 6.0 mAdc 20 35 50 mV
0 20 35 mV
–0.22 –0.16 %V
±15 µV/°C
400 550 750 1250
1.0 ms
MECHANICAL CHARACTERISTICS
Characteristic Symbol Min Typ Max Unit
Weight (Basic Element, Case 344–15) 2.0 Grams Common Mode Line Pressure
NOTES:
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range. Operating the device above the specified excitation range may induce additional error due to device self–heating.
3. Full Scale Span (V minimum rated pressure.
4. Offset (V
5. Accuracy (error budget) consists of the following:
Linearity: Output deviation from a straight line relationship with pressure, using end point method, over the specified
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
TcSpan: Output deviation at full rated pressure over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative
TCR: Zin deviation with minimum rated pressure applied, over the temperature range of –40°C to +125°C,
6. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a specified step change in pressure.
7. Common mode pressures beyond specified may result in leakage at the case–to–lead interface.
8. Exposure beyond these limits may cause permanent damage or degradation to the device.
9. Offset stability is the product’s output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
) is defined as the output voltage at the minimum rated pressure.
off
(7)
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
FSS
pressure range.
cycled to and from the minimum or maximum operating temperature points, with zero differential pressure applied.
minimum or maximum rated pressure, at 25°C.
to 25°C.
relative to 25°C.
690 kPa
FSS FSS FSS
FSS
FSS
/°C
2 Motorola Sensor Device Data
TEMPERATURE COMPENSATION
Figure 2 shows the typical output characteristics of the
MPX10 series over temperature.
The X–ducer piezoresistive pressure sensor element is a semiconductor device which gives an electrical output signal proportional to the pressure applied to the device. This de­vice uses a unique transverse voltage diffused semiconduc­tor strain gauge which is sensitive to stresses produced in a thin silicon diaphragm by the applied pressure.
Because this strain gauge is an integral part of the silicon diaphragm, there are no temperature effects due to differ­ences in the thermal expansion of the strain gauge and the diaphragm, as are often encountered in bonded strain gauge pressure sensors. However, the properties of the strain gauge itself are temperature dependent, requiring that the device be temperature compensated if it is to be used over an extensive temperature range.
Temperature compensation and offset calibration can be achieved rather simply with additional resistive components,
 
or by designing your system using the MPX2010D series sensor.
Several approaches to external temperature compensa­tion over both – 40 to +125°C and 0 to + 80°C ranges are presented in Motorola Applications Note AN840.
LINEARITY
Linearity refers to how well a transducer’s output follows the equation: V pressure range (Figure 3). There are two basic methods for calculating nonlinearity: (1) end point straight line fit or (2) a least squares best line fit. While a least squares fit gives the “best case” linearity error (lower numerical value), the cal­culations required are burdensome.
Conversely, an end point fit will give the “worst case” error (often more desirable in error budget calculations) and the calculations are more straightforward for the user. Motorola’ s specified pressure sensor linearities are based on the end point straight line method measured at the midrange pressure.
out
= V
+ sensitivity x P over the operating
off
80
70 60 50 40
OUTPUT (mVdc)
30 20 10
0
0
PSI kPa
VS = 3 Vdc
P1 > P2
0.3
2.0
0.6
4.0
PRESSURE DIFFERENTIAL
+25°C
0.9
6.0
–40°C
+125°C
1.2
8.0 10
SPAN
RANGE
(TYP)
OFFSET
(TYP)
1.5
70
60
50
40
30
OUTPUT (mVdc)
20
10
0
0 MAX
LINEARITY
ACTUAL
THEORETICAL
PRESSURE (kPA)
Figure 2. Output versus Pressure Differential Figure 3. Linearity Specification Comparison
WIRE BOND
SILICONE DIE COAT
DIE
P1
STAINLESS STEEL
METAL COVER
EPOXY
CASE
SPAN
(V
)
FSS
OFFSET
(V
)
OFF
P
OP
LEAD FRAME
Figure 4. Cross–Sectional Diagram (not to scale)
Figure 4 illustrates the differential or gauge configuration in the basic chip carrier (Case 344–15). A silicone gel iso­lates the die surface and wire bonds from the environment, while allowing the pressure signal to be transmitted to the sil­icon diaphragm.
The MPX10 series pressure sensor operating characteris-
RTV DIE
P2
BOND
tics and internal reliability and qualification tests are based on use of dry air as the pressure media. Media other than dry air may have adverse effects on sensor performance and long term reliability. Contact the factory for information re­garding media compatibility in your application.
3Motorola Sensor Device Data
Loading...