Moog POWER VOLTAGE SWITCHING UNIT DATASHEET

POWER MANAGEMENT UNIT_
Power and
Voltage-Switching Unit (PVSU)
Features
The PVSU combines and modernizes the three most common military ground-mobile power handling
LRUs (PDU, PSU, & VSU)
The PVSU utilizes state-of-the-art, self-protected, BIT capable, “Smart Power” switching hybrids and interface circuitry
The PVSU provides full BIT/BITE, diagnostics, and fault isolation
The PVSU is the easily integrated, full military environment qualified power handling solution for legacy Platform
upgrades and new platform designs
Description
The power distribution portion current limits, filters and distributes the platform’s prime power source to the platform’s DC power grid
Power system faults are displayed and communicated on the CAN Bus
Electronic “circuit-breakers” can be reset locally or remotely via the CAN Bus
The power select portion allows the user to switch between various platform and external power sources
NATO (28V) Receptacle, Auxiliary Power Unit, Shore Power (AC), Inverter outputs, etc.
The voltage switching portion displays the State of Health (SoH) for the battery bank(s), the ac input/inverter outputs, and provides optional Battery Bank switching for isolation, load switching, battle-override, and emergency starting functions.
POWER AND VOLTAGE SWITCHING UNIT_
PVSU_
PVSU Specifications
20 Electronic Circuit-Breakers (ECB)
Configurable 5A to 50A
“Reset” from Front Panel or via CAN Bus
Remote Breaker Assembly provides 20 additional
PVSU controlled ECBs
I/O Connectors
Front panel aux connectors
Aluminum enclosure and cover
DC input voltage
Transient voltages (single fault)
EMI/EMC/E
Temperture: Method 501.4
Vibration: Method 514.5 Shock: Method 516.5-8 Humidity: Method 507.4
Salt Fog: Method 509.4
Sand and Dust: Method 510.4
Fungus: Method 508.5
Altitude: Method 500.4
Immersion: Method 512.4
Cleaning
Envelope
Weight
3
Displays
Two, Battery State of Health
Power Fault for ECB status/control
AC & DC Voltage
Two, Inverter Power Status
Display test & brightness functions
Specifications
MIL-STD-461E: CE102, CS101, CS114, CS115, CS116, RE102, RS103
MIL-STD-464: Lightening, electrical bonding and grounding, upgradeable for TEMPEST
Environmental (MIL-STD-810F)
Mechanical data
Comprehensive diagnostics & BIT/BITE
PBIT, CBIT, & IBIT (if required)
Status reported on serial bus (CAN)
Communication
CAN Bus
RS232
GbE Wire/Fiber, standard option
Easily upgraded for other Buses
M38999, Series III, signal/power
M5015, high power
2, 12 Vdc, 10A 2, 28 Vdc, 10A
1, 120 Vac, 15A, GFI
MIL-C-5541/53072 conversion/CARC coatings
Fully sealed, NBC decontamination
28V per MIL-STD-1275C and MIL-STD-704F
100V surge, 250V spikes
Controlled to <= 51V
Reverse voltage protected
Nuclear weapons INR/EMP hardening an option
P-I, storage, Tst = -51˚ C to 85˚ C
P-II, Operation, Top = -40˚ C to 71˚ C
Cat-24, Minimum integrity test vehicle
40 g, 7.5ms
5 cycles, 95% RH
5%, 48 hours
P-I and P-II, 6 hours
28 days
P-I and P-II, 6 hours
P-II, operation
P-III, rapid decompression
P-II, 1m, 1 hour
10 gpm, .25” ø nozzle, 1 ft to LRU
11.5” x 20.0” x 7.0” < 30 lbs (14 kg)
© 20 10 Mo og , I nc . A ll r igh ts re se rv ed.
East Aurora, NY 14052 USA
+1.716.652.2000
www.moog.com
Form 500-722 1010