Please set the voltage using the
remote controller.
For the setting method. please refer to
the indoor unit Installation Manual.
1 2 3 4 5
ON
OFF
MODELS
Table 1
SW1
Manufacture/Service
PLA-RP. AA
1 2 3 4 5
ON
OFF
MODELS
Table 2
SW2
Manufacture/Service
PLA-RP35AA
PLH-P35AAH
PLA-RP50AA
PLH-P50AAH
PLA-RP60AA
PLH-P60AAH
PLA-RP71AA
PLH-P71AAH
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
PLH-P. AAH
TB2
I.B
HEATER CN24
(YLW)
[PLH-P.AAH models only]
POWER SUPPLY
~(1PHASE)
230V 50Hz
88H
FS1
26H
FS2
H1
L
REDREDRED
BLU
GRN/YLW
WHT
WHT
WHTGRY
N
2
1
2
6
5
1
88H
YLW
YLW
NOTES:
1.Symbols used in wiring diagram above are, : Connector, : Terminal (block).
2.Indoor and outdoor connecting wires are made with polarities, make wiring
matching terminal numbers (S1,S2,S3).
3.Since the outdoor side electric wiring may change be sure to check the outdoor
unit electric wiring for servicing.
4.This dlagram shows the wiring of Indoor and Outdoor connecting wires
(specification of 230V), adopting superimposed system of power and signal.
w1 ; When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig1.
w2 ; For power supply system of this unit, refer to the caution label located near this diagram.
WIRING DIAGRAM
4-1. INDOOR UNIT
PLA-RP35AAPLA-RP50AAPLA-RP60AAPLA-RP71AA
Please set the voltage using the
remote controller.
For the setting method. please refer to
the indoor unit Installation Manual.
S1
S2
S3
TB4
TO
OUTDOOR
UNIT
YLW
ORN
YLWYLW
ORN
BRN
ORN
1
11
3
1
2
2
5
1
2
3
1
3
5
53
RECTIFIER
TRANS
IPM
P.B
MF
1
2
3
9 5
10
7632184
5MV5MV5
5
MV5MV
GRILLE
H2
GRILLE
BLK
X1
J41
J42
X1
31213
DP
D.U.M
CNP
(BLU)
YLW
YLW
ORN
ORN
YLW
BLK
WHT
PNK
3133131
YLW
YLW
D.HEATER
CNC
(RED)
CN33
(GRN)
CN02
(GRN)
CN01
(BLK)
POSITION DETECTION
SENSOR INPUT
CN3
(WHT)
CN03
(BLU)
CN2S
(WHT)
FAN
CN2
(GRN)
CN4
(WHT)
FUSE
ZNR
DCL
FAN
WHT
BRN
POWER
CND
(ORN)
21
POWER
CN2D
(WHT)
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
CN41CN51CN2L
CN32
9
WIRELESS
CN90
(WHT)
BZ
5
5
VANE
CN6V
(GRN)
W.B
I.B
LED2
CNB
LED1
SW1SW2
RU
21
2
21
1
REMOCON
CN22
(BLU)
TB5
TRANSMISSION WIRES
DC12V
TB6
R.B
BLU
BLU
212121
D.SENSOR
CN31
(WHT)
INTAKE
CN20
(RED)
LIQUID
CN21
(WHT)
DS
TH2
21
PIPE
CN29
(BLK)
TH5
TH1
LED3
Pair No.
LED2 LED1
ON
OFF
SWE
Refer to tables 1
and 2.
wBe sure to turn off the source power
and then disconnect fan motor connector.
(Failure to do so will cause trouble in Fan motor)
SW2SW1
BLK
WHT
RED
31
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
TB4
YLW
ORN
ORN
BRN
TO OUTDOOR UNIT
S1
S2
S3
I.B
P.B
TB2
POWER SUPPLY
~(1PHASE)
230V 50Hz
RED
BLU
GRN/YLW
L
N
3
1
5
CN01
(BLK)
YLW
ORN
w1 (Fig.1)
1 2 3 4 5
ON
OFF
(Table 1) SW1 (MODEL SELECTION)
SW1
Manufacture/Service
(Table 2) SW2 (CAPACITY CORD)
1 2 3 4 5
ON
OFF
MODELS
SW2
Manufacture/Service
PLA-RP100AA2PLA-RP140AA2
PLA-RP125AA2
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
MODELS
Manufacture/Service
1.Symbols used in wiring diagram above are, : Connector, :
Terminal (block).
2.Indoor and outdoor connecting wires are made with polarities, make wiring
matching terminal numbers (S1,S2,S3).
3.Since the outdoor side electric wiring may change be sure to check the
outdoor unit electric wiring for servicing.
4.This dlagram shows the wiring of indoor and outdoor connecting wires.
(specification of 230V), adopting superimposed system of power and signal.
w1 ; When work to supply power separately to indoor and outdoor unit was
applied, refer to Fig1.
w2 ; For power supply system of this unit, refer to the caution label located
near this diagram.
WIRELESS REMOTE CONTROLLER BOARD
RECEIVING UNIT
BUZZER
LED <RUN INDICATOR>
LED <HOT ADJUST>
SWITCH (HEATING ON/ OFF>
SWITCH (COOLING ON/ OFF>
WIRED REMOTE CONTROLLER BOARD
R.B
HEATER
RU
BZ
LED1
LED2
SW1
SW2
NAMESYMBOL
HEATER
H1
THERMAL FUSE <84:10A>
FS2
THERMAL FUSE <104:10A>
FS1
HEATER THERMAL SWITCH
26H
HEATER CONTACTOR
88H
NOTES:
1. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
2. Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1, S2, S3).
3. Make sure that the main power supply of the booster heater is independent.
4. Symbols used in wiring diagram above are, : Connector, : Terminal (block).
w1. When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig 1.
w2. For power supply system of this unit, refer to the caution label located near this diagram.
41
PKA-RP60FALPKA-RP71FALPKA-RP100FAL
INTAKE
CN20
(
RED
)
LIQUID
CN21
(
WHT
)
PIPE
CN29
(
BLK
)
1 2
1 2
1 2
1 31 31 31 2
TH5TH1
TH2
REMOCON
CN22
(
BLU
)
1 2
2
1
TB5
R.B
TB6
2
1
TRANSMISSION WIRES DC12V
SWE
ON
OFF
SW2SW1
LED3 LED2 LED1
ZNR
FUSE
X4
CN41CN2L
CN51CN32
WIRELESS
CN90
(
WHT
)
VANE
CN6V
(
GRN
)
MV
6
W.B
BZ
CNB
RECEIVER
RU
LED1 LED2 SW2SW1
9
FAN
(
WHT
)
1 3 5
1
1
2
1
2
3
2 3
BLK
WHT
WHT
RED
RED
C
MF
X4
BCR
TO
OUTDOOR
UNIT
TB4
S1
S2
S3
YLW
ORN
ORN
BRN
YLW
ORN
BLK
WHT
P.B
I.B
Please set the voltage
using the remote controller.
For the setting method,
please refer to the indoor
unit Installation Manual
1. Since the outdoor side electric wiring may change be sure to
check the outdoor unit electric wiring for servicing.
2. Indoor and outdoor connecting wires are made with polarities, make
wiring matching terminal numbers (S1, S2, S3).
3. Make sure that the main power supply of the booster heater is
independent.
4. Symbols used in wiring diagram above are,
: Connector, : Terminal (block).
W
1. When work to supply power separately to
Indoor and Outdoor unit was applied, refer to Fig 1.
W
2. For power supply system of this unit,
refer to the caution label located near this diagram.
[Servicing]
Fasten terminal of the terminal board "TB4"equips lock system.
To remove the fastened terminal, pull it while pressing the protruding
portion (locking lever) of the terminal. The fastened terminal protruding
portion should face upward.
When installing drain-up
machine (Optional part).
W
When installing optional
drain-up machine disconnect
the CN31 jumper connector
and replace it with the
drain sensor (DS).
PCA-RP100GA PCA-RP125GAPCA-RP140GA
43
PCA-RP71HAPCA-RP125HA
SYMBOL
[ LEGEND ]
NAMESYMBOLNAME
INDOOR POWER BOARD
INDOOR CONTROLLER BOARD
FUSE (T6.3AL250V)
MF1, MF2
C1, C2
H2
FAN MOTOR
CAPACITOR(FAN MOTOR)
DEW PREVENTION HEATER
VARISTOR
CONNECTOR (LOSSNAY)
CONNECTOR (REMOTE SWITCH)
CONNECTOR (HA TERMINAL-A)
CONNECTOR (CENTRALLY CONTROLL)
POWER SUPPLY (I. B)
POWER SUPPLY (R. B)
TRANSMISSION(INDOOR-OUTDOOR)
RELAY (DEW PREVENTION HEATER)
RELAY(FAN MOTOR)
RELAY(FAN MOTOR)
RELAY(FAN MOTOR)
SWITCH (MODEL SELECTION)
See Table 1.
SWITCH (CAPACITY CODE) See Table 2.
SWITCH (EMERGENCY OPERATION)
Please set the voltage using the
remote controller.
For the setting method, please refer to
the indoor unit Installation Manual.
3131
POWER
CND
(ORN)
INDOOR/OUTDOOR
COMMUNICATION
CN3C
(BLU)
TB4
POWER
SUPPLY
~(1PHASE)
230V 50Hz
RED
TB2
BLU
TO
OUTDOOR
UNIT
L
S1
S2
S3
N
I.B
YLW
ORN
ORN
ORN
YLW
GRN/YLW
BRN
w1 (Fig.1)
NOTES:
1.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1,S2,S3).
3.Symbols used in wiring diagram above are, : Connector, : Terminal (block).
1 ; When work to supply power separately to Indoor and Outdoor unit was applied, refer to Fig1.
2 ; For power supply system of this unit, refer to the caution label located near this diagram.
44
PSA-RP71GAPSA-RP100GAPSA-RP125GAPSA-RP140GA
1357
MF
ORN
C
RED
BLK
BLU
YLW
13131312
1
2
2
1
3
13
ML
YLW
YLW
BLK
ORN
YLW
YLW
ORNS1S2
S3
WHT
WHT
WHT
BRN
ORN
RED
I.B
FAN
(WHT)
LOUVER
CNL
(YLW)
X4X5X6
X6
X5 X4
X2
ZNR
FUSE
X2
LED3 LED2 LED1
SWE
ON
OFF
POWER
CNDK
(RED)
POWER
CND
(ORN)
POWER
CN2D
(WHT)
WIRELESS
CN90
(WHT)
2
1
REMOCON
CN22
(BLU)
CN32
CN2L
2
1
TB6
2
2
1
1
2
1
LIQUID
CN21
(WHT)
INTAKE
CN20
(RED)
PIPE
CN29
(BLK)
CN24CN41
CN51
R.B
TRANSMISSION
WIRES DC12V
BLU
BLU
TH1
TH2
TH5
SW1SW2
TB4
REDRED
WHT
RED
BLU
GRN/YLW
88H
FS1FS2
H
53
1
2
L
N
TB2
POWER SUPPLY
~(1 PHASE)
230V 50Hz
2
1
6
5
RED
RED
YLW
26H
88H
YLW
YLW
16
HEATER
CN24
(YLW)
I.B
PSH -P.GAH
models only
INDOOR UNIT
Please set the voltage using the
remote controller.
For the setting method, please refer to
the indoor unit Installation Manual.
FUSE (6.3A 250V)
FUSE (6.3A 250V)
FUSE (6.3A 250V)
FUSE (6.3A 250V)
MC/CH RELAY
21S4 RELAY
FAN CONTROLLER
GROUP NUMBER ADDRESS
TEST RUN
FUNCTION SELECTION
JUMPER WIRE
MODEL SELECTION w2
TRANSFORMER
CURRENT TRANS
OPERATION CHECK DISPLAY LED
OPERATION CHECK DISPLAY LED
EMERGENCY OPERATION CONNECTER
CNMNT
SW1SW4
S1
S2
S3
(WHT)
J6
w2
CNLEV
(WHT)
123456789
(WHT)
TH3/TH6
JA
JB
(RED)
T
TH4
SYMBOL
MC
MF
TH3
TH4
TH6
C3
C5
CH
52C
21S4
63H
49C
TB1
LEV
O.B
NAME
COMPRESSOR(INNER THERMOSTAT)
FAN MOTOR(INNER THERMOSTAT)
THERMISTOR
LIQUID TEMP
DISCHARGE TEMP
COND./EVA.TEMP
MF CAPACITOR
MC CAPACITOR
CRANKCASE HEATER
MC CONTACTOR
4-WAY VALVE SOLENOID COIL
HIGH PRESSURE PROTECT SWITCH
INNER THERMOSTAT FOR MC
TERMINAL BLOCK
LINEAR EXPANSION VALVE
OUTDOOR CONTROLLER BOARD
49C
MC
A1A1A2A2B1
B1
S
C
R
R
W
B
E
H
C5
L
D
T
U
6
2
/
/
T
T
3
1
1
5
/
/
L
L
1
3
C3
CH
52C
52C
21S4
MF
a
b
63H
BLU
RED
MF3
(WHT)
13
52C
(PNK)
313131
CH
(BLU)
21S4
(GRN)
w1
4/SR
X51
X52
FUSE2
O.B
634
121223145
NAME
LEV
TH4
TH6
TH3
R
B
E
L
D
U
TB1
NL
POWER SUPPLY
~/N
230V 50Hz
Y
O
B
L
R
R
W
N
N
S3S2S1
S3
INDOOR
UNIT
S2
S1
TB4
w1 PUH-P71/P100VHA MODEL ONLY
w2 MODEL SELECTION
MODEL
PUH-P71VHA
PUH-P100VHA
PU-P71VHA
PU-P100VHA
: with jumper wire O : without jumper wire
J1
J2
J4
J5 J6
O
O
O
O
OJ3O
O
O
O
O
O
O
O
O
<Notes when servicing>
Some fastening terminals have a lock mechanism:When removing the fastening terminal, push the projection (locking lever)on a
terminal with your finger and pull it out.
46
PUH-P71YHAPUH-P100YHAPUH-P125YHAPUH-P140YHA
313131
3131
31
MC
MF
LEV
MF4
(WHT)
52
(PNK)
51CM
(ORN)
63L
(RED)
CH
(BLU)
SV
(BLK)
21S4
(GRN)
TH3/TH6
(RED)
CNVMNT
(WHT)
CNMNT
(WHT)
CNLEV
(WHT)
TH4
(WHT)
LED1(GRN)
LED2(RED)
R
E
D
U
V
W
2
/
T
1
51C
TB1TB2
TB4
INDOOR
UNIT
L3NL2L1
S3S2S1
S1
S3
S2
S1
T
S2
S3
52C
W
H
T
4
/
T
2
B
L
K
R
E
D
W
H
T
B
L
K
B
L
U
Y
L
W
O
R
N
B
R
N
6
/
T
3
1
/
L
1
3
/
L
2
5
/
L
3
C4
CT
O.B
F.C
13
MF
21S4
SV
52C
63H
w
3
w1
w2
w1
w1
63L
51C
(WHT)
MF3
C3
a
b
X51
X52
X53
4/STSR
FUSE3
FUSE4
FUSE1
CN31
w4
CNM
SW5
ON
OFF
SW1SW4
FUSE2
CH
BLK
RED
WHT
13
A1A1A2A2B1
B1
121223145
321 12345
123456789
1011121314
634
TH3
TH6
TH4
J1J2J3J4J5J6JA
JB
POWER SUPPLY
3N~
400V 50Hz
<Notes when servicing>
Some fastening terminals have a lock mechanism:When removing the fastening terminal, push the projection(locking lever)on a terminal with
your finger and pull it out.
MC
MF
TH3
TH4
TH6
C3
C4
CH
52C
21S4
SV
63H
51C
TB1
LEV
TB2
63L
O.B
FUSE (6.3A 250V)
FUSE (6.3A 250V)
FUSE (6.3A 250V)
FUSE (6.3A 250V)
MC/CH RELAY
21S4 RELAY
SV RELAY
FAN CONTROLLER
GROUP NUMBER ADDRESS
TEST RUN
FUNCTION SELECTION
JUMPER WIRE
MODEL SELECTION w4
TRANSFORMER
CURRENT TRANS
OPERATION CHECK DISPLAY LED
OPERATION CHECK DISPLAY LED
EMERGENCY OPERATION CONNECTER
NAME
MODEL
J1 J2
O
O
O
O
J3
O
O
O
O
J4
O
O
O
O
J5
O
O
J6
O
O
O
O
O
O
PUH-P71YHA
PU-P71YHA
PUH-P100YHA
PU-P100YHA
PUH-P125YHA
PU-P125YHA
PUH-P140YHA
PU-P140YHA
: with jumper wire O : without jumper wire
w1 PU(H)-P125/140YHA MODEL ONLY
w2 PUH-P71/P100/P125/P140YHA MODEL ONLY
w3 PU(H)-P71/100YHA MODEL ONLY
w4 MODEL SELECTION
PU-P71YHAPU-P100YHAPU-P125YHAPU-P140YHA
47
5
Thermistor TH2
Pipe temperature (Liquid)
Distributor
with strainer(#50)
Thermistor TH5
(Cond./Eva. temperature)
Thermistor TH1
(Room temperature)
Refrigerant flow in cooling
Refrigerant flow in heating
Strainer(#50)
Strainer(#50)
Heat exchanger
Refrigerant GAS pipe connection
(Flare)
Refrigerant LIQUID pipe connection
(Flare)
REFRIGERANT SYSTEM DIAGRAM
5-1. INDOOR UNIT
PLA-RP•AA(2)PLH-P•AAHPMH-P•BA
PEAD-RP•EA(2)PEHD-P•EAHPEAD-RP•GA
PKA-RP•GALPKH-P•GALHPKA-RP•FALPKH-P•FALH
PCA-RP•GAPCH-P•GAHPCA-RP•HA
PSA-RP•GAPSH-P•GAH
48
5-2. OUTDOOR UNIT
Outdoor heat exchanger
Thermistor
(TH3)
Thermistor
(TH6)
Distributor
Service
port
(check)
Accumulator
Compressor
Refrigerant GAS pipe
15.88A({5/8")
Refrigerant LIQUID pipe
9.52A({3/8")
Stop valve
(with service port)
4-way valve
Service port
(check)
High pressure
protect switch
Refrigerant flow in cooling
Refrigerant flow in heating
Liner expansion valve
Thermistor
(TH4)
Muffler
Ball valve
(#50)
Strainer
(#100)
Strainer
Strainer
(#40)
(#100)
Strainer
Bypass valve
Service
port
(check)
Accumulator
Compressor
Refrigerant GAS pipe
15.88A({5/8")
Refrigerant LIQUID pipe
9.52A({3/8")
4-way
valve
Service port (check)
High pressure protect switch
Liner expansion valve
Muffler
Thermistor
(TH4)
Refrigerant flow in cooling
Refrigerant flow in heating
<TRIPLE SYSTEM>
Total length A + B + C + D
P140: 50 m
3.6kg
4.4kg
5.0kg
31 — 40m
0.6kg
0.6kg
0.6kg
41 — 50m
1.2kg
1.2kg
1.2kg
<Table 7> Additional refrigerant charging amount for pipe of standard diameter
Outdoor unit
Permitted
pipe length
Additional refrigerant charging amount
for pipe length exceeding 30 m (kg)
Amount of unit filling refrigerant (kg)
PU(H)-P71V/YHA
PU(H)-P100V/YHA
PU(H)-P125,140YHA
50m or less
50m or less
50m or less
Note1. The number of bendsin the refrigerant pipe is respectively 8 or less in the range of <A+B> <A+C> <A+D>
2. PU(H)-P71,100,125,140 : 30m chargeless
8-2. ADJUSTING THE AMOUNT OF REFRIGERANT
• Check additional refrigerant charging amount referring to table 5.6 when liquid pipe is one size larger than standard diameter.
54
8-3. CAPACITY CURVE
100
95
90
85
80
Capacity ratio [%]
75
70
Cooling
Heating
Cooling P71 model
Cooling P100 model
Cooling P125 model
Cooling P140 model
5 101520253035404550
Corrected pipe length [m]
55
9
PLA-RP71AA
PLH-P71AAH
PLA-RP100AA2
PLH-P100AAH
PLA-RP125AA2
PLH-P125AAH
PLA-RP140AA2
PLH-P140AAH
28
4.9
7.4
30
6.6
8.9
30
6.6
8.9
Air flow
Air speed
Coverage range
m
3
/min.
m/sec.
m
20
4.0
5.7
14
2.8
4.0
18
3.6
5.2
18
3.6
5.2
PLA-RP35AA
PLH-P35AAH
PLA-RP50AA
PLH-P50AAH
PLA-RP60AA
PLH-P60AAH
Air flow
Air speed
Coverage range
m
3
/min
m/sec
m
PCA-RP50GA
PCH-P50GAH
PCA-RP60GA
PCH-P60GAH
PCA-RP71GA
PCH-P71GAH
PCA-RP100GA
PCH-P100GAH
PCA-RP125GA
PCH-P125GAH
PCA-RP140GA
PCH-P140GAH
25
4.1
12.6
34
4.4
15.2
34
4.4
15.2
18
3.8
10.4
18
3.8
10.4
13
3.7
8.8
Air flow
Air speed
Coverage range
m3/min
m/sec
m
19
2.9
7.9
38
4.2
13.2
PCA-RP71HA PCA-RP125HA
12
5.3
10(32.8)
PKA-RP35GAL
PKH-P35GALH
12
5.3
10(32.8)
PKA-RP50GAL
PKH-P50GALH
Air flow
Air speed
Coverage range
m
3
/min
m/sec
m(ft)
20
4.9
12.4(40.7)
PKA-RP71FAL
PKH-P71FALH
20
4.9
12.4(40.7)
PKA-RP60FAL
PKH-P60FALH
28
5.4
15.3(50.2)
PKA-RP100FAL
PKH-P100FALH
Air flow
Air speed
Coverage range
m
3
/min
m/sec
m(ft)
Air flow
Air speed
Coverage range
m
3
/min
m/sec
m
PSA-RP71GA
PSH-P71GAH
PSA-RP100GA
PSH-P100GAH
PSA-RP125GA
PSH-P125GAH
PSA-RP140GA
PSH-P140GAH
18
2.6
8.3
31
4.5
14.3
33
4.8
15.2
35
4.9
16.1
10.0
4.3
7.0
8.4
3.7
5.9
11.0
4.7
7.7
PMH-P25BA
PMH-P35BA
PMH-P50BA
Air flow
Air speed
Coverage range
m
3
/min
m/sec
m
AIR FLOW DATA
9-1. OUTLET AIR SPEED AND COVERAGE RANGE
The air coverage range is the value up to the position where the air speed is 0.25m/sec. when air is blown out horizontally from
the unit at the Hi notch position.
The coverage range should be used only as a general guideline since it varies according to the size of the room and the furniture inside the room.
56
9-2. PLA-RP·AA, PLA-RP·AA2
9-2-1. FRESH AIR INTAKE AMOUNT
57
9-2-2. BRANCH DUCT (Installation at site)
58
Branch duct air flow rate/static pressure characteristics
PLA-RP35AA
4-way air flow (horizontal vane) Rectangular duct4-way air flow (horizontal vane) Round duct
3-way air flow (horizontal vane) Rectangular duct3-way air flow (horizontal vane) Round duct
2-way air flow (horizontal vane) Rectangular duct2-way air flow (horizontal vane) Round duct
59
PLA-RP50AA
PLA-RP60AA
4-way air flow (horizontal vane) Rectangular duct4-way air flow (horizontal vane) Round duct
3-way air flow (horizontal vane) Rectangular duct3-way air flow (horizontal vane) Round duct
2-way air flow (horizontal vane) Rectangular duct2-way air flow (horizontal vane) Round duct
60
PLA-RP71AA
4-way air flow (horizontal vane) Rectangular duct4-way air flow (horizontal vane) Round duct
Static pressure [Pa]
30
20
10
High
Low
0
123456
Air flow rate [m
3
/min]
Static pressure [Pa]
30
20
10
High
Low
0
123456
Air flow rate [m
3-way air flow (horizontal vane) Rectangular duct3-way air flow (horizontal vane) Round duct
Static pressure [Pa]
60
50
40
30
20
10
High
Low
0
123456789
Air flow rate [m
3
/min]
60
50
40
30
20
10
Static pressure [Pa]
High
Low
0
123456789
Air flow rate [m
3
/min]
3
/min]
2-way air flow (horizontal vane) Rectangular duct2-way air flow (horizontal vane) Round duct
100
Static pressure [Pa]
90
80
70
60
50
40
30
20
10
0
1234567891011
Low
High
Air flow rate [m
3
/min]
100
90
80
70
60
50
40
30
20
Static pressure [Pa]
10
0
1234567
Air flow rate [m
Low
High
3
/min]
61
PLA-RP100AA2
4-way air flow (horizontal vane) Rectangular duct4-way air flow (horizontal vane) Round duct
Static pressure [Pa]
50
40
30
20
10
0
1234 5678910
Low
High
Air flow rate [m
3
/min]
Static pressure [Pa]
50
40
30
20
10
0
Low
1234 5678910
High
Air flow rate [m
3-way air flow (horizontal vane) Rectangular duct3-way air flow (horizontal vane) Round duct
100
Static pressure [Pa]
90
80
70
60
50
40
30
20
10
0
1 23 45 6 78 9 10 11 12 13 14
Low
High
Air flow rate [m
3
/min]
100
90
80
70
60
50
40
Static pressure [Pa]
30
20
10
0
Low
1234567 891011121314
High
Air flow rate [m
3
3
/min]
/min]
2-way air flow (horizontal vane) Rectangular duct2-way air flow (horizontal vane) Round duct
120
110
100
Static pressure [Pa]
90
80
70
60
50
40
30
20
10
0
2 3 45 6 7 8 9 10 11 12 13 14 15 16
1
High
Low
Air flow rate [m
3
/min]
120
110
100
90
80
70
60
50
40
30
Static pressure
20
10
0
1
Low
2 3 45 6 7 8 9 10 11 12 13 14 15 16
High
Air flow rate [m
62
3
/min]
PLA-RP125AA2
PLA-RP140AA2
4-way air flow (horizontal vane) Rectangular duct4-way air flow (horizontal vane) Round duct
Static pressure [Pa]
50
40
30
20
10
0
Low
12345678910
High
Air flow rate [m
Static pressure [Pa]
50
40
30
20
10
0
12345678910
Low
High
Air flow rate [m
3
/min]
3-way air flow (horizontal vane) Rectangular duct3-way air flow (horizontal vane) Round duct
100
Static pressure [Pa]
90
80
70
60
50
40
30
20
10
0
1234567891011121314
Low
High
Air flow rate [m
3
/min]
100
Static pressure [Pa]
90
80
70
60
50
40
30
20
10
0
1234567891011121314
Low
High
Air flow rate [m
3
/min]
3
/min]
2-way air flow (horizontal vane) Rectangular duct2-way air flow (horizontal vane) Round duct
120
110
100
Static pressure [Pa]
90
80
70
60
50
40
30
20
10
0
2 3 45 6 7 8 9 10 11 12 13 14 15 16
1
Air flow rate [m
Low
High
3
/min]
120
110
100
Static pressure[Pa]
90
80
70
60
50
40
30
20
10
0
2 3 45 6 7 8 9 10 11 12 13 14 15 16
1
Low
High
Air flow rate [m
63
3
/min]
50.0
-50.0
-100.0
0.00.51.0
Air flow (m
3
/min)
2 intakes
1 intake
Characteristic diagram of air capacity taken from outside
Static pressure (Pa)
1.52.02.5
0.0
PMH-P25BA
PMH-P35BA
PMH-P50BA
8.4m3/min
10.0m3/min
11.0m3/min
1.6m3/min
2.0m3/min
2.2m3/min
Air flow
(Hi)
Air capacity taken outside
(Knock out)
4-{2.8
Flesh air intake hole
(Knock out)
Flesh air intake hole
90-
{
122
{
100
108
250288.5
Q
0
B
A
C
1
2
3
Curve in the
left praphs.
Duct characteristics
at site
Q
A
EC
Q
Qa
AD
9-3. PMH-P•BA
Air capacity taken from outside
PMH-P·BA series are possible to be taken air from outside.
When taking air from the outside, the duct fan can be used to.
The air capacity should be 20% or less of the air flow SPEC(Hi).
How to read curves
Q…Planned amount of fresh air intake <m
A…Static pressure loss of fresh air intake duct system with air flow amount Q <Pa>
B…Forced static pressure at air conditioner inlet with air flow amount Q <Pa>
C…Static pressure of booster fan with air flow amount Q <Pa>
D…Static pressure loss increase amount of fresh air intake duct system for air flow amount Q <Pa>
E…Static pressure of indoor unit with air flow amount Q <Pa>
Qa…Estimated amount of fresh air intake without D <m3/min>
3
/min>
64
9-4. PEAD-RP·EA,EA2,GA
Fan Performance <30Pa>
External static pressure (Pa)
(1Pa 0.1mmAq)
Air Flow (CMM)
6810 12 14 16 18 20
8 101214161820 22
20
40
60
80
100
120
140
0.8
0.9
1.0
1.1
Corrected Air Flow
Capacity
input
Cooling
Air flow (CMM)
Correction factor
Fan Performance <70Pa>
External static pressure (Pa)
(1Pa 0.1mmAq)
Air Flow (CMM)
8 10121416182022
8 101214161820 22
20
40
60
80
100
120
140
160
0.8
0.9
1.0
1.1
1.2
1.3
Heating
Air flow (CMM)
Correction factor
Fan Performance <30Pa>
External static pressure (Pa)
(1Pa 0.1mmAq)
Air Flow (CMM)
8 1012141618202224
12 14 16 18 2022 24 26
20
40
60
80
100
120
0.8
0.9
1.0
1.1
Corrected Air Flow
Capacity
input
Cooling
Air flow (CMM)
Correction factor
Fan Performance <70Pa>
External static pressure (Pa)
(1Pa 0.1mmAq)
Air Flow (CMM)
10 12 14 16 18 20 22 24 26
12 14 16 18 2022 24 26
20
40
60
80
100
120
140
0.8
0.9
1.0
1.1
1.2
1.3
Heating
Air flow (CMM)
Correction factor
9-4-1. FAN PERFORMANCE AND CORRECTED AIR FLOW
PEAD-RP35EA2
PEAD-RP50EA
PEAD-RP60EA
65
PEAD-RP71EA
Lo
Hi
140
120
100
200
180
160
80
60
40
20
12 16 20 24 28 32
Air flow
(CMM)
Fan performance <130Pa>
Recommended range
External static pressure (Pa)
(1Pa 0.1mmAq)
140
120
100
180
160
80
60
40
20
12 16 20 24 28 32
Air flow
(CMM)
Fan performance <70Pa>
Recommended range
External static pressure (Pa)
(1Pa 0.1mmAq)
=
Lo
Hi
Corrected Air Flow
Capacity
Input
1.1
1.0
0.9
0.8
121620242832
Air flow (CMM)
Correction factor
Cooling
=
1.1
1.0
1.3
1.2
0.9
0.8
121620242832
Air flow (CMM)
Correction factor
Heating
Lo
Hi
140
120
100
200
220
180
160
80
60
40
20
32 34 36 38 40 42 44 46 48
Air flow
(CMM)
Fan performance <130Pa>
Recommended range
External static pressure (Pa)
(1Pa 0.1mmAq)
140
120
100
200
220
180
160
80
60
40
20
32 34 36 38 40 42 44 46
Air flow
(CMM)
Fan performance <70Pa>
Recommended range
External static pressure (Pa)
(1Pa 0.1mmAq)
Lo
Hi
Corrected Air Flow
Capacity
Input
1.1
1.0
0.9
0.8
323436384042444648
Air flow (CMM)
Correction factor
Cooling
1.1
1.0
1.2
0.9
0.8
323436384042444648
Air flow (CMM)
Correction factor
Heating
=
=
PEAD-RP100EA2
PEAD-RP125EA
66
PEAD-RP140EA
1.2
1.1
1.0
0.9
0.8
363840424446
48
5052
Air flow (CMM)
Correction factor
Heating
Corrected Air Flow
Capacity
Input
1.1
1.0
0.9
0.8
363840424446
4850
52
Air flow (CMM)
Correction factor
Cooling
Lo
Hi
200
180
160
140
120
100
80
60
40
20
36
38 40 42 44 46 48
50
Air flow
(CMM)
Fan performance <70Pa>
Recommended range
External static pressure (Pa)
(1Pa 0.1mmAq)
=
Lo
200
220
180
160
140
120
100
80
60
40
20
36
38 40 42 44 46 48 50
52
Air flow
(CMM)
Fan performance <130Pa>
Recommended range
External static pressure (Pa)
(1Pa 0.1mmAq)
=
Hi
67
PEAD-RP60GA
PEAD-RP71GA
68
PEAD-RP100GA
69
10
PLA-RP35AAPLA-RP50AA
PLA-RP60AA
NOTCH SPL(dB) LINE
High
Medium1
Medium2
Low
High
Medium1
Medium2
Low
31
29
28
27
NOTCH SPL(dB)LINE
33
31
29
28
90
80
70
60
50
40
30
20
10
631252505001000 20004000 8000
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
BAND CENTER FREQUENCIES, Hz
PLA-RP71AAPLA-RP100AA2
NOTCH SPL(dB) LINE
34
32
30
28
NOTCH SPL(dB)LINE
41
39
36
33
90
80
70
60
50
40
30
20
10
631252505001000 20004000 8000
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
BAND CENTER FREQUENCIES, Hz
90
80
70
60
50
40
30
20
10
631252505001000 20004000 8000
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
BAND CENTER FREQUENCIES, Hz
High
Medium1
Medium2
Low
High
Medium1
Medium2
Low
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
NOISE CRITERION CURVES
10-1. INDOOR UNIT
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
70
NOTCH SPL(dB) LINE
PLA-RP125AA2PLA-RP140AA2
High
Medium1
Medium2
Low
45
43
40
37
NOTCH SPL(dB) LINE
High
Medium1
Medium2
Low
45
43
40
37
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
UNIT
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
CEILING
1.5m
MICROPHONE
71
PMH-P25BA
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
35
33
31
29
LINE
PMH-P35BA
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
40
38
36
34
LINE
90
80
70
60
50
40
30
20
APPROXIMATE THRESHOLD OF
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.002µ BAR
HEARING FOR CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.002µ BAR
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
PMH-P50BA
90
80
70
60
50
40
30
APPROXIMATE
20
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.002µ BAR
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
NOTCH
SPL(dB)
High
Medium1
Medium2
Low
BAND CENTER FREQUENCIES, Hz
LINE
42
40
38
36
UNIT
CEILING
NC-70
NC-60
1.5m
MICROPHONE
NC-50
NC-40
NC-30
NC-20
72
PEAD-RP35EA2
PEAD-RP50EA
70
60
50
40
30
(External static
pressure 30Pa)
High
Low
NC60
NC50
NC40
NC30
PEAD-RP35EA2
PEAD-RP50EA
70
60
50
40
30
(External static
pressure 70Pa)
High
Low
NC60
NC50
NC40
NC30
20
10
Approximate minimum
audible limit on
continuous noise
OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa
0
6312525050010002000 40008000
OCTAVE BAND CENTER FREQUENCIES (Hz)
PEAD-RP60EA
70
60
50
40
30
20
10
Approximate minimum
audible limit on
continuous noise
OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa
0
6312525050010002000 40008000
OCTAVE BAND CENTER FREQUENCIES (Hz)
(External static
pressure 30Pa)
High
Low
NC20
NC60
NC50
NC40
NC30
NC20
20
10
Approximate minimum
audible limit on
continuous noise
OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa
0
6312525050010002000 40008000
OCTAVE BAND CENTER FREQUENCIES (Hz)
PEAD-RP60EA
70
60
50
40
30
20
10
Approximate minimum
audible limit on
continuous noise
OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa
0
6312525050010002000 40008000
OCTAVE BAND CENTER FREQUENCIES (Hz)
(External static
pressure 70Pa)
High
Low
NC20
NC60
NC50
NC40
NC30
NC20
73
74
PKA-RP35GAL
PKA-RP50GAL
90
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
43
41
38
36
LINE
PKA-RP60FAL
PKA-RP71FAL
90
NOTCH
High
Low
SPL(dB)39LINE
45
80
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0dB=0.0002 µbar)
APPROXIMATE
20
TERESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
PKA-RP100FAL
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Low
SPL(dB)
46
41
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
LINE
OCTAVE BAND SOUND PRESSURE LEVEL, dB(0dB=0.0002 µ bar)
80
70
60
50
40
30
APPROXIMATE
20
TERESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
UNIT
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
WALL
OCTAVE BAND SOUND PRESSURE LEVEL, dB(0dB=0.0002 µ bar)
90
80
70
60
50
40
30
APPROXIMATE
20
TERESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
1m
1m
MICROPHONE
75
PCA-RP50GA
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
42
40
38
37
LINE
PCA-RP60GA
PCA-RP71GA
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
43
41
39
37
LINE
90
80
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
PCA-RP100GA
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
45
43
41
40
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
LINE
90
80
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
PCA-RP125GA
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
46
45
43
41
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
LINE
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
76
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
90
80
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
PCA-RP140GA
90
NOTCH
High
Medium1
Medium2
Low
SPL(dB)
48
46
44
42
LINE
80
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
PCA-RP71HA
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Low
SPL(dB)
38
34
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
LINE
1m
1m
about 1.4m
MICROPHONE
PCA-RP125HA
NOTCH
High
Low
SPL(dB)
50
44
ceiling
unit
LINE
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR
90
80
70
60
50
40
30
APPROXIMATE
20
TERESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR
90
80
70
60
50
40
30
APPROXIMATE
20
TERESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
77
PSA-RP71GA
NOTCH
High
Low
SPL(dB)
45
40
LINE
PSA-RP100GA
NOTCH
High
Low
SPL(dB)
49
44
LINE
90
80
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR
APPROXIMATE
20
HERESHOLD OF
REARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
PSA-RP125GA
BAND CENTER FREQUENCIES, Hz
NOTCH
High
Low
SPL(dB)
51
46
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
LINE
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR
90
80
70
60
50
40
30
APPROXIMATE
20
HERESHOLD OF
REARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR
90
80
70
60
50
40
30
APPROXIMATE
20
HERESHOLD OF
REARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
78
PSA-RP140GA
90
80
NOTCH
High
Low
SPL(dB)
52
47
LINE
70
60
50
40
30
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 µBAR
APPROXIMATE
20
HERESHOLD OF
REARING FOR
CONTINUOUS
NOISE
10
631252505001000 20004000 8000
MICROPHONE
1m
1m
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
BAND CENTER FREQUENCIES, Hz
unit
floor
79
10-2. OUTDOOR UNIT
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
PUH-P71VHA
PUH-P71YHA
PU-P71VHA
PU-P71YHA
COOLING
MODE
HEATING
49
SPL(dB)
50
LINE
90
80
70
60
50
40
30
20
10
631252505001000 2000 4000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
BAND CENTER FREQUENCIES, Hz
PUH-P100VHA
PUH-P100YHA
PU-P100VHA
PU-P100YHA
90
80
MODE
COOLING
HEATING
SPL(dB)
50
52
LINE
PUH-P125YHA
PU-P125YHA
90
80
70
60
50
40
30
20
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
10
SPL(dB)
MODE
COOLING
HEATING
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
631252505001000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
50
52
LINE
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
80
PUH-P140YHA
PU-P140YHA
90
80
MODE
COOLING
HEATING
SPL(dB)
51
53
LINE
70
60
50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 µbar)
Wired remote controllerPAR-21MAAT-EPKA-RP·GAL
(with terminal bed)PKA-RP·FAL
Drain lift up mechanismPAC-SE90DM-EPKA-RP·FAL
PAC-SK003MT-FPEAD-RP125,140EA
(for high external static pressure)PEAD-RP100EA2
Drain lift up mechanismPAC-KE03DM-FPEAD-RP·EA,EA2
Insulation kitPAC-SK010DKPEAD-RP·GA
OPTIONAL PARTS
82
11-2. OUTDOOR UNIT
Part NameModel Name
M-NET adapterPAC-SF80MA-EPU(H)-P71-140
A-control service toolPAC-SK52ST
Drain socketPAC-SG61DS-EPU(H)-P71-140
Air outlet guide (P125, 140 needs two piece)
Air protect guidePAC-SH63AG-EPU(H)-P71-140
Drain panPAC-SG64DP-EPU(H)-P71-140
Filter dryer
Distribution pipe
HEAD OFFICE : TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
CCopyright 2006 MITSUBISHI ELECTRIC ENGINEERING CO., LTD.
Distributed in May 2006 No.OCS07 REVISED EDITION-B PDF 8
Distributed in Apr. 2006 No.OCS07 REVISED EDITION-A PDF 8
Distributed in Mar. 2006 No.OCS07 PDF 8
Made in Japan.