FEATURES
• Variable speed INVETER-driven compressor
• Built-in base pan heater
• Quiet outdoor unit operation as low as 58 dB(A)
• High pressure protection
• Compressor overcurrent detection
• Fan motor overheating/voltage protection
®
hyper heat performance o󰀨ers 100% heating capacity at 5°F and 74% heating capacity at -13°F
• H2i
• ENERGY STAR
®
certied (non-ducted)
ENERGY STAR products are third-party certied by an EPA-recognized Certication Body.
Specications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
SPECIFICATIONS: MXZ-3C30NAHZ2
(For data on specic indoor units, see the MXZ-C Technical and Service Manual.)
Rated Capacity Btu/h 28,400 / 27,400
Cooling* (Non-ducted / Ducted)
Heating at 47°F* (Non-ducted / Ducted)
Heating at 17°F* (Non-ducted/Ducted)
Heating at 5°F* Maximum Capacity Btu/h 28,600
Connectable Capacity Btu/h 12,000 - 36,000
Energy Star
Electrical Requirements
Voltage
Compressor DC INVERTER-driven Twin Rotary
Fan Motor (ECM) F.L.A. 2.43
Sound Pressure Level
External Dimensions (H x W x D)
Net Weight Lbs / kg 189 / 86
External Finish Munsell No. 3Y 7.8/11
Refrigerant Pipe Size O.D.
Max. Refrigerant Line Length Ft / m 230 / 70
Max. Piping Length for Each Indoor Unit Ft / m 82 / 25
Max. Refrigerant Pipe Height Di󰀨erence
Connection Method Flared/Flared
Refrigerant R410A
* Rating Conditions per AHRI Standard: Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / W.B. 23.9° C (75° F)
OPERATING RANGE: ENERGY EFFICIENCIES:
®
(ENERGY STAR products are third-party certied by an EPA-recognized Certication Body.) Yes
Capacity Range Btu/h 12,600 - 28,400
Rated Total Input W 2,272 / 2,661
Rated Capacity Btu/h 28,600 / 27,600
Capacity Range Btu/h 11,400 - 36,000
Rated Total Input W 2,096 / 2,187
Rated Capacity Btu/h 18,000 / 16,500
Maximum Capacity Btu/h 28,600 / 27, 600
Rated Total Input W 1,991 / 1,993
Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz
Recommended Fuse/Breaker Size A 40
MCA A 30.5
Indoor - Outdoor S1-S2 V AC 208 / 230
Indoor - Outdoor S2-S3 V DC ±24
Cooling dB(A) 54
Heating dB(A) 58
In
mm
Liquid (High Pressure) In / mm 1/4 / 6.35
Gas (Low Pressure) In / mm A:1/2 / 12.7 ; B,C: 3/8 / 9.52
If IDU is Above ODU Ft / m 49 / 15
If IDU is Below ODU Ft / m 49 / 15
Heating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB
Heating at 17º F | Indoor: 70º F (21º C) DB Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB
41-9/32 x 37-13/32 x 13
1048 x 950 x 330
Outdoor
Cooling D.B. 14 to 115° F [ D.B. −10 to 46° C]*1
Heating W.B. -13 to 65° F [ W.B. −25 to 18° C ]
NOTES: For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity can exceed rated, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time.
Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F
Non-ducted (09+09+12)
Ducted and Non-ducted
Ducted (09+09+12)
18.0 12.5 11.0 4.00 2.65
17.00 11.40 10.40 3.85 2.58
16.0 10.3 9.8 3.70 2.50
Specications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.