Mitsubishi MUX-A22WV Service Manual

Page 1
SERVICE MANUAL
HFC
utilized
R410A
SPLIT-TYPE, AIR CONDITIONER
Multi system type Model
No. OB318
MUX-A22WV -
MUX-A22WV -
Indication of model name
NOTE:
•This manual describes technical data of outdoor unit.
•As for indoor unit MSC-A07WV - or MSC-A12WV - , refer to the service manual OB307 REVISED EDITION-A.
E1
E1E1
E1
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················4
3. INDOOR / OUTDOOR CORRESPONDENCE TABLE ···························5
4. SPECIFICATION·················································5
5. NOISE CRITERIA CURVES·······························6
6. OUTLINES AND DIMENSIONS························ 6
7. WIRING DIAGRAM ············································7
8. REFRIGERANT SYSTEM DIAGRAM················8
9. PERFORMANCE CURVES································9
11. TROUBLESHOOTING······································15
12. DISASSEMBLY INSTRUCTIONS·····················21
13. PARTS LIST······················································23
Page 2
1
Refrigerating
oil
Refrigerant
New refrigerant
R410A
HFC-32: HFC-125 (50%:50%)
Pseudo-azeotropic refrigerant
Not included
A1/A1
72.6
-51.4
1.557 64
Non combustible
0
1730
From liquid phase in cylinder
Possible
Incompatible oil
Non Non
Previous refrigerant
R22
R22 (100%)
Single refrigerant
Included
A1
86.5
-40.8
0.94
44.4
Non combustible
0.055 1700
Gas phase
Possible
Compatible oil
Light yellow
Non
Refrigerant Composition (Ratio) Refrigerant handling Chlorine Safety group (ASHRAE) Molecular weight Boiling point (:) Steam pressure [25:](Mpa) Saturated steam density [25:](Kg/K) Combustibility ODP w1 GWP w2 Refrigerant charge method Additional charge on leakage Kind Color Smell
w1:Ozone Destruction Parameter : based on CFC-11 w2 :Global Warmth Parameter : based on CO
2
New Specification Current Specification
The incompatible refrigerating oil easily separates from refrigerant and is in the upper layer inside the suction muffler. Raising position of the oil back hole enables to back the refrigerating oil of the upper layer to flow back to the compressor.
Since refrigerant and refrigerating oil are compatible each, refrigerating oil backs to the compressor through the lower position oil back hole.
Compressor
Suction muffler
Oil back hole
Refrigerating oil
Refrigerant
Compressor
Suction muffler
Oil back hole
Refrigerating oil /Refrigerant
Compressor
TECHNICAL CHANGES
INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT
• This room air conditioner adopts an HFC refrigerant (R410A) which never destroys the ozone layer.
• Pay particular attention to the following points, though the basic installation procedure is same as that for R22 conditioners. 1 As R410A has working pressure approximate 1.6 times as high as that of R22, some special tools and piping parts/
materials are required. Refer to the table below.
2 Take sufficient care not to allow water and other contaminations to enter the R410A refrigerant during storage and
installation, since it is more susceptible to contaminations than R22.
3 For refrigerant piping, use clean, pressure-proof parts/materials specifically designed for R410A. (Refer to 2. Refrigerant
piping.)
4 Composition change may occur in R410A since it is a mixed refrigerant. When charging, charge liquid refrigerant to prevent
composition change.
NOTE : The unit of pressure has been changed to MPa on the international system of units(SI unit system).
The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/ff[Gauge])
2
Page 3
Conversion chart of refrigerant temperature and pressure
R410A tools Can R22 tools be used?
Gas leak detector
R410A has high pressures beyond the measurement range of existing gauges. Port diameters have been changed to prevent any other refrigerant from being charged into the unit.
Hose material and cap size have been changed to improve the pressure resistance.
Dedicated for HFC refrigerant.
6.35 mm and 9.52 mm
Description
Clamp bar hole has been enlarged to reinforce the spring strength in the tool. Provided for flaring work (to be used with R22 flare tool).
Provided to prevent the back flow of oil. This adapter enables you to use vacuum pumps.
It is difficult to measure R410A with a charging cylinder because the refrigerant bubbles due to high pressure and high-speed vaporization
No
No
No
Yes
Yes
New
New
New
Gauge manifold
Charge hose
Torque wrench
Flare tool Flare gauge
Vacuum pump adapter
Electronic scale for refrigerant charging
No : Not Substitutable for R410A Yes : Substitutable for R410A
No 12.7 mm
Wall thickness
Outside diameter
Pipe
mm
For liquid For gas
6.35
9.52
12.7
0.8 mm
0.8 mm
0.8 mm
Heat resisting foam plastic Specific gravity 0.045 Thickness 8 mm
Insulation material
(MPa [Gauge])
4.0
3.5
3.0
2.5
2.0
1.5
R410A R22
NOTE : The unit of pressure has been changed to MPa on the
international system of units(SI unit system).
1.0
0.5
Saturated liquid pressure
0.0
-0.5
-30 -20 -10 0 10 20
30
40 50 60
The conversion factor is: 1(MPa [Gauge]) =10.2(kgf/ff[Gauge])
(:)
1.Tools dedicated for the air conditioner with R410A refrigerant
The following tools are required for R410A refrigerant. Some R22 tools can be substituted for R410A tools. The diameter of the service port on the stop valve in outdoor unit has been changed to prevent any other refrigerant being charged into the unit. Cap size has been changed from 7/16 UNF with 20 threads to 1/2 UNF with 20 threads.
2.Refrigerant piping
1 Specifications
Use the refrigerant pipes that meet the following specifications.
• Use a copper pipe or a copper-alloy seamless pipe with a thickness of 0.8 mm. Never use any pipe with a thickness less
than 0.8mm, as the pressure resistance is insufficient.
2 Flaring work and flare nut
Flaring work for R410A pipe differs from that for R22 pipe. For details of flaring work, refer to Installation manual “FLARING WORK”.
3
Page 4
Pipe diameter
Air outlet
Drain outlet
Air inlet
Piping
Drainage hose
(Back and side)
Dimension of flare nut
mm
6.35
9.52
12.7
R410A
17 22 26
R22
17 22 24
3.Refrigerant oil
Apply the special refrigeration oil (accessories: packed with indoor unit) to the flare and the union seat surfaces.
4.Air purge
• Do not discharge the refrigerant into the atmosphere. Take care not to discharge refrigerant into the atmosphere during installation, reinstallation, or repairs to the refrigerant
circuit.
• Use the vacuum pump for air purging for the purpose of environmental protection.
5.Additional charge
For additional charging, charge the refrigerant from liquid phase of the gas cylinder. If the refrigerant is charged from the gas phase, composition change may occur in the refrigerant inside the cylinder and the outdoor unit. In this case, ability of the refrigerating cycle decreases or normal operation can be impossible. However, charging the liquid refrigerant all at once may cause the compressor to be locked. Thus, charge the refrigerant slowly.
Union
Stop valve
Indoor unit
Refrigerant gas cylinder operating valve
Liquid pipe Gas pipe
Service port
Outdoor unit
2
PART NAMES AND FUNCTIONS
OUTDOOR UNIT
MUX-A22WV-
E1
Gauge manifold valve (for R410A)
Charge hose (for R410A)
Refrigerant gas cylinder for R410A with siphon
Refrigerant (liquid)
Electronic scale for refrigerant charging
4
Page 5
MUX-A22WV- E1
Combination
of the
connectable
indoor units
OUTDOOR UNIT
A:
MSC-A12WV- E1
B:
MSC-A07WV- E1
C:
INDOOR / OUTDOOR CORRESPONDENCE TABLE3
MUX-A22WV -
4
Capacity
Electrical
Compressor
Fan
Special
SPECIFICATION
Outdoor unit power supply
Capacity Dehumidification Outdoor air flow Power outlet Running current Power input Auxiliary heater Power factor
data
Starting current Compressor motor current Fan motor current
Coefficient of performance (C.O.P)
Model Output Winding resistance (at 20:) Model Winding
motor
resistance (at 20:) Dimensions WOHOD Weight Sound level Fan speed Fan speed regulator Refrigerant filling
remarks
capacity (R410A) Refrigerating oil (Model)
E1
Outdoor model
Function
Indoor unit No
E1
MUX-A22WV -
Cooling
Single phase
230V,50Hz
.
kW
R/h
K /h
A A
W
A(kW)
%
A A A
W
"
"
mm
kg
dB
rpm
kg cc
Single
A
3.5
1.4
5.73
1,280
97.1
5.02
2.65
Single B or C
2.4
0.9
3.64 815
97.3
2.99
2.82
MC1 : RN145VHSHT, MC2 : RN092VHSHT
MC1 : 1,000, MC2 : 600
MC1 : , MC2 :
MC1 : 620 (NEO22), MC2 : 350 (NEO22)
Double
A+B or A+C
3.5+2.4
1.4+0.9 2,460
20
8.92
1,975
96.3 48
8.01
0.57
2.88
C-R 2.43 C-S 3.80
RA6V60-GA
WHT-BLK 90 BLK-RED 146 840O640O330
67 52
730
1
0.85 (Room A)
0.85 (Room B+C)
Double
1.45O2
C-R 3.87 C-S 0.14
B+C
0.4
3.69 830
97.8
2.99
3.22
Triple
A+B+C
3.4+1.45O2
1.4+0.4
8.84
1,980
97.4
8.01
3.01
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor DB27°C WB19°C
Outdoor DB35°C WB24°C Indoor-Outdoor piping length 5m w Reference value
5
Page 6
NOISE CRITERIA CURVES5
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions.
Cooling :DB35: WB24:
COOL
FUNCTION
52
SPL(dB(A)) LINE
MUX-A22WV - E1
500
840 61
264
10°
10°
Service panel
Open as a rule 500mm or more if the front and both sides are open
100mm or more 200mm or more if there are obstacles to both sides
Open as a rule 500mm or more if the back, both sides and top are open
350mm or more
100mm or more
B UNIT A UNIT
Gas refrigerant pipe joint Refrigerant pipe (flared)
Liquid refrigerant pipe joint Refrigerant pipe (flared) {6.35
65
121
40
438
Air in
Air out
Air in
273
100
125
320
30
330
640
360
76
5050505050
Drainage 3holes {33
}
C UNIT
} }
34
C or B unit {9.52 A unit {12.7
6
MUX-A22WV-
OUTLINES AND DIMENSIONS
E1
OUTDOOR UNIT
6
Unit: mm
Page 7
7
1
2
3
1
2
3
123
213
123123123
21R421R3
NR61
T61
1
2
43
43
C61
LD1
WHT
WHT
OUTDOOR CONTROL P.C. BOARD
BRN
BLU
BRN
BLU
BRN
BLU
BLU
X522
X521
BLK
SR865
SR866
SR863
SR861
LD2
RED
RED
RED
BLK
WHT
652341
BRN BLU
BLU
TB4
CN86
CN85
CN81
CN91
CN90
TB3
TB2
X521
BLU BLU
X522
BLU
BLU
21RB
F61
CN74
CN73
CN71
TO INDOOR
UNIT B
CONNECTING
12V
PE
CIRCUIT BREAKER
GRN/YLW
WHT
BLU
ORN
BLU
YLW
BLU
RED
RED
TO INDOOR
UNIT A
CONNECTING
12V
1
2
1
2
C2
C1
RC
S
CR
S
MC2
TO INDOOR
UNIT C
CONNECTING
12V
MF61
MC1
BLK
TB1
POWER SUPPLY
~/N
230V
50Hz
1
2
L
N
DSAR
BRN
WIRING DIAGRAM
MUX-A22WV -
OUTDOOR UNIT
E1
MODEL WIRING DIAGRAM
VG79B520H01
TERMINAL BLOCK
TRANSFORMER
COMPRESSOR CONTACTOR(MC1)
COMPRESSOR CONTACTOR(MC2)
SOLENOID COIL
SOLENOID COIL (B)
SOLENOID COIL (C)
T61
SYMBOL
TB2~TB4
NAME NAME
X521
X522
21RB
21R3
21R4
OUTDOOR FAN MOTOR(INNER PROTECTOR)
SURGE ABSORBER
OUTDOOR FAN RELAY
MF61
NR61
SYMBOL
NAME
SYMBOL
SR861
COMPRESSOR CAPACITOR(MC1)
COMPRESSOR CAPACITOR(MC2)
OUTDOOR FAN CAPACITOR
C1
C2
C61
RELAY (21RB)
RELAY (C) (21R4)
RELAY (B) (21R3)
TERMINAL BLOCK
SR863
SURGE ABSORBER
DSAR
TB1
SR865
SR866
FUSE(3.15A)
COMPRESSOR(INNER PROTECTOR)
COMPRESSOR(INNER PROTECTOR)
F61
MC1
MC2
2. Use copper conductors only. (For field wiring)
NOTE:1. About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.
/: Terminal block, : Connector
3. Symbols below indicate.
7
Page 8
OUTDOOR UNIT
INDOOR UNIT
UNIT A
Indoor
heat
exchanger
Indoor coil thermistor RT12
Room temperature thermistor RT11
UNIT B
Indoor
heat
exchanger
Outdoor
heat
exchanger
Indoor coil thermistor RT12
Room temperature thermistor RT11
(With insulation)
Refrigerant pipe
12.7
(With insulation)
Refrigerant pipe
9.52
(With insulation)
Refrigerant pipe
6.35
Flared connection
(With insulation)
Refrigerant pipe
6.35
Flared connection
Refrigerant pipe
9.52
(With insulation)
Refrigerant pipe
6.35
Flared connection
Stop valve with service port
Stop valve
Solenoid valve 21R3
Solenoid valve 21R4
Solenoid valve 21RB
Stop valve with service port
Stop valve with service port
Capillary tube CT1
Capillary tube CT3
Capillary tube CT4
Capillary tube CT2
Capillary tube CT5
Compressor(A)
Compressor(B,C)
Refrigerant flow in cooling
UNIT C
Indoor
heat
exchanger
Indoor coil thermistor RT12
Room temperature thermistor RT11
Stop valve
Stop valve
Strainer #100
Muffler
Muffler
[3.0 x [1.6 x 900
[3.0 x [1.4 x 1000
[3.0 x [1.6 x 900
[3.0 x [1.6 x700
[3.0 x [1.6 x 900
Strainer #100
Strainer #100
8
LA
Indoor unit A
HL
B HLC
H
Indoor unit B
Indoor unit C
Outdoor unit
MUX-A22WV - E1
REFRIGERANT SYSTEM DIAGRAM
Unit : mm
MUX-A22WV-
E1
E1
MUX-A22WV-
MAX.REFRIGERANT PIPING LENGTH & MAX. HEIGHT DIFFERENCE
8
Page 9
Max. limits
UNIT No.
Unit A Unit B
Unit C
L LB
LC
A
Pipe length
15m 15m
15m
B
L
+
LC
ADDITIONAL REFRIGERANT CHARGE (R410A:g)
Refrigerant piping length (one way)
9m
40
Refrigerant piping length (one way, 2 unit total)
Unit A
Unit B + Unit C
Outdoor unit
precharged
850g
Outdoor unit
precharged
850g
7m
0
10m11m12m13m14m15m16m17m18m19m20m21m22m23m24m25m26m27m28m29m30
0 102030405060
8m 20
PIPING PREPARATION
1Table below shows the specifications of pipes commercially available.
UNIT No.
Unit A
Unit B and Unit C
Pipe
For liquid
For gas
For liquid
For gas
Outside diameter
mm
6.35
12.7
6.35
9.52
Height difference (H)
10m
Total
30m
10m6011m
80
70 80 90 100 110 120 130 140 150 160 170 180 190 200
Insulation thickness
8mm 8mm 8mm 8mm
10m 10m
12m
100
13m
120
Insulation material
Heat resisting foam plastic
0.045 specific gravity
No. of bends
10 10 10
14m
140
Total
15
15m
160
m
2Ensure that the 2 refrigerant pipes are well insulated to prevent condensation. 3Refrigerant bending radius must be 100mm or more.
9
MUX-A22WV -
The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions, since operating conditions vary according to the areas where these units are installed. The following information has been pro­vided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
PERFORMANCE CURVES
E1
(1) GUARANTEED VOLTAGE
198~264V, 50Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature : °CWB (2) Indoor outlet air wet-bulb temperature : °CWB (3) Outdoor intake air dry-bulb temperature : °CDB (4) Total input: W
Indoor air wet/dry-bulb temperature difference on the left side of the chart on page 10 shows the difference between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.
9
Page 10
How to measure the indoor air wet-bulb/dry-bulb temperature difference
Single operation (Unit B or C)
Outdoor unit current (A)
2.0
2.5
3.0
3.5
4.0
230V
230V
1.3
1.1
1.0
0.9
0.8
0.7
Outdoor low pressure (kgf/F[Gauge])
11
10
9
8
7
13
1.2
12
(kgf/F[Gauge])(MPa[Gauge])
Ambient temperature(˚C)
Ambient humidity(%)
20 50
2560 30
70
(˚C)
(%)
Ambient temperature(˚C)
Ambient humidity(%)
20 50
2560 30
70
(˚C)
(%)
1.2
1.0
0.9
0.8
0.7
0.6
(kgf/F[Gauge])(MPa[Gauge])
Outdoor low pressure (kgf/F[Gauge])
10
9
8
7
6
12
1.1
11
Outdoor unit current (A)
Single operation (Unit A)
4.0
5.0
6.0
7.0
230V
230V
Ambient temperature(˚C)
Ambient humidity(%)
20 50
2560 30
70
(˚C)
(%)
Ambient temperature(˚C)
Ambient humidity(%)
20 50
2560 30
70
(˚C)
(%)
1. Attach at least 2 sets of wet-and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets of wet-and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air speed is high.
2. Attach at least 2 sets of wet-and dry-bulb thermometers to the outdoor air intake. Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of room.
5. Press the EMERGENCY OPERATION switch once to start the EMERGENCY COOL MODE.
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
INDOOR UNIT
Wet-and dry-bulb thermometers
9-1.CAPACITY AND THE INPUT CURVES
(ONE INDOOR UNIT WITH ONE OUTDOOR UNIT)
9.4
10.2
8.6
9.4
7.8
8.5
7.1
7.7
6.3
6.9
5.6
6.1
Indoor air WB temperature
difference (deg.)
A
B or C
OUTDOOR UNIT
Wet-and dry-bulb thermometers
MUX-A22WV- E1
MUX-A22WV- E1
(MSC-A07WV- E1 )
(MSC-A12WV- E1 )
9-2.OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT
COOL operation
Both indoor and outdoor unit are under
same temperature/humidity condition.
Air flow should be set at MAX.The unit of pressure has been changed to MPa on
the international system of units(SI unit system). The conversion factor is : 1(MPa[Gauge]) =10.2(kgf/ff[Gauge] )
MUX-A22WV-
E1
10
Dry-bulb temperature Relative humidity (%)
20 25 30
50 60 70
Page 11
PERFORMANCE DATA
21 18 4.11 2.25 0.55 1056 3.94 2.15 0.55 1109 3.78 2.07 0.55 1162 3.64 1.99 0.55 1214 21 20 4.29 1.83 0.43 1109 4.11 1.76 0.43 1175 3.99 1.70 0.43 1201 3.85 1.64 0.43 1254 22 18 4.11 2.41 0.59 1056 3.94 2.31 0.59 1109 3.78 2.22 0.59 1162 3.64 2.14 0.59 1214 22 20 4.29 2.00 0.47 1109 4.11 1.92 0.47 1175 3.99 1.86 0.47 1201 3.85 1.80 0.47 1254 22 22 4.46 1.55 0.35 1148 4.31 1.49 0.35 1221 4.20 1.46 0.35 1254 4.03 1.40 0.35 1307 23 18 4.11 2.58 0.63 1056 3.94 2.47 0.63 1109 3.78 2.37 0.63 1162 3.64 2.28 0.63 1214 23 20 4.29 2.17 0.51 1109 4.11 2.09 0.51 1175 3.99 2.02 0.51 1201 3.85 1.95 0.51 1254 23 22 4.46 1.73 0.39 1148 4.31 1.67 0.39 1221 4.20 1.63 0.39 1254 4.03 1.56 0.39 1307 24 18 4.11 2.74 0.67 1056 3.94 2.63 0.67 1109 3.78 2.52 0.67 1162 3.64 2.43 0.67 1214 24 20 4.29 2.35 0.55 1109 4.11 2.25 0.55 1175 3.99 2.18 0.55 1201 3.85 2.11 0.55 1254 24 22 4.46 1.91 0.43 1148 4.31 1.84 0.43 1221 4.20 1.79 0.43 1254 4.03 1.72 0.43 1307 24 24 4.69 1.44 0.31 1201 4.52 1.39 0.31 1267 4.41 1.35 0.31 1307 4.27 1.31 0.31 1373 25 18 4.11 2.91 0.71 1056 3.94 2.78 0.71 1109 3.78 2.67 0.71 1162 3.64 2.57 0.71 1214 25 20 4.29 2.52 0.59 1109 4.11 2.41 0.59 1175 3.99 2.34 0.59 1201 3.85 2.26 0.59 1254 25 22 4.46 2.08 0.47 1148 4.31 2.01 0.47 1221 4.20 1.96 0.47 1254 4.03 1.88 0.47 1307 25 24 4.69 1.63 0.35 1201 4.52 1.57 0.35 1267 4.41 1.53 0.35 1307 4.27 1.48 0.35 1373 26 18 4.11 3.07 0.75 1056 3.94 2.94 0.75 1109 3.78 2.82 0.75 1162 3.64 2.72 0.75 1214 26 20 4.29 2.69 0.63 1109 4.11 2.58 0.63 1175 3.99 2.50 0.63 1201 3.85 2.41 0.63 1254 26 22 4.46 2.26 0.51 1148 4.31 2.18 0.51 1221 4.20 2.13 0.51 1254 4.03 2.04 0.51 1307 26 24 4.69 1.82 0.39 1201 4.52 1.75 0.39 1267 4.41 1.71 0.39 1307 4.27 1.65 0.39 1373 26 26 4.83 1.29 0.27 1267 4.69 1.25 0.27 1333 4.62 1.23 0.27 1373 4.48 1.20 0.27 1412 27 18 4.11 3.24 0.79 1056 3.94 3.10 0.79 1109 3.78 2.97 0.79 1162 3.64 2.86 0.79 1214 27 20 4.29 2.86 0.67 1109 4.11 2.74 0.67 1175 3.99 2.66 0.67 1201 3.85 2.57 0.67 1254 27 22 4.46 2.44 0.55 1148 4.31 2.35 0.55 1221 4.20 2.30 0.55 1254 4.03 2.20 0.55 1307 27 24 4.69 2.00 0.43 1201 4.52 1.93 0.43 1267 4.41 1.88 0.43 1307 4.27 1.82 0.43 1373 27 26 4.83 1.48 0.31 1267 4.69 1.44 0.31 1333 4.62 1.42 0.31 1373 4.48 1.38 0.31 1412 28 18 4.11 3.40 0.83 1056 3.94 3.26 0.83 1109 3.78 3.13 0.83 1162 3.64 3.01 0.83 1214 28 20 4.29 3.03 0.71 1109 4.11 2.91 0.71 1175 3.99 2.82 0.71 1201 3.85 2.72 0.71 1254 28 22 4.46 2.62 0.59 1148 4.31 2.53 0.59 1221 4.20 2.47 0.59 1254 4.03 2.36 0.59 1307 28 24 4.69 2.19 0.47 1201 4.52 2.11 0.47 1267 4.41 2.06 0.47 1307 4.27 1.99 0.47 1373 28 26 4.83 1.68 0.35 1267 4.69 1.63 0.35 1333 4.62 1.60 0.35 1373 4.48 1.55 0.35 1412 29 18 4.11 3.57 0.87 1056 3.94 3.41 0.87 1109 3.78 3.28 0.87 1162 3.64 3.16 0.87 1214 29 20 4.29 3.20 0.75 1109 4.11 3.07 0.75 1175 3.99 2.98 0.75 1201 3.85 2.88 0.75 1254 29 22 4.46 2.80 0.63 1148 4.31 2.70 0.63 1221 4.20 2.63 0.63 1254 4.03 2.52 0.63 1307 29 24 4.69 2.38 0.51 1201 4.52 2.29 0.51 1267 4.41 2.24 0.51 1307 4.27 2.16 0.51 1373 29 26 4.83 1.87 0.39 1267 4.69 1.82 0.39 1333 4.62 1.79 0.39 1373 4.48 1.73 0.39 1412 30 18 4.11 3.73 0.91 1056 3.94 3.57 0.91 1109 3.78 3.43 0.91 1162 3.64 3.30 0.91 1214 30 20 4.29 3.37 0.79 1109 4.11 3.24 0.79 1175 3.99 3.14 0.79 1201 3.85 3.03 0.79 1254 30 22 4.46 2.98 0.67 1148 4.31 2.87 0.67 1221 4.20 2.80 0.67 1254 4.03 2.68 0.67 1307 30 24 4.69 2.57 0.55 1201 4.52 2.47 0.55 1267 4.41 2.41 0.55 1307 4.27 2.34 0.55 1373 30 26 4.83 2.06 0.43 1267 4.69 2.00 0.43 1333 4.62 1.97 0.43 1373 4.48 1.91 0.43 1412 31 18 4.11 3.89 0.95 1056 3.94 3.73 0.95 1109 3.78 3.58 0.95 1162 3.64 3.45 0.95 1214 31 20 4.29 3.55 0.83 1109 4.11 3.40 0.83 1175 3.99 3.30 0.83 1201 3.85 3.18 0.83 1254 31 22 4.46 3.15 0.71 1148 4.31 3.04 0.71 1221 4.20 2.97 0.71 1254 4.03 2.85 0.71 1307 31 24 4.69 2.75 0.59 1201 4.52 2.65 0.59 1267 4.41 2.59 0.59 1307 4.27 2.51 0.59 1373 31 26 4.83 2.26 0.47 1267 4.69 2.19 0.47 1333 4.62 2.16 0.47 1373 4.48 2.09 0.47 1412 32 18 4.11 4.06 0.99 1056 3.94 3.89 0.99 1109 3.78 3.73 0.99 1162 3.64 3.59 0.99 1214 32 20 4.29 3.72 0.87 1109 4.11 3.57 0.87 1175 3.99 3.46 0.87 1201 3.85 3.34 0.87 1254 32 22 4.46 3.33 0.75 1148 4.31 3.22 0.75 1221 4.20 3.14 0.75 1254 4.03 3.01 0.75 1307 32 24 4.69 2.94 0.63 1201 4.52 2.83 0.63 1267 4.41 2.77 0.63 1307 4.27 2.68 0.63 1373 32 26 4.83 2.45 0.51 1267 4.69 2.38 0.51 1333 4.62 2.34 0.51 1373 4.48 2.27 0.51 1412
CAPACITY : 3.5(kW) SHF : 0.73 INPUT : 1320(W)
OUTDOOR DB(:)
INDOOR
INDOOR
25 27 30
DB(:)
WB(:)
Q
SHC
SHF
INPUT
Q
SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
21
COOL operation (230V)
MSC-A12WV - (Single : Room A) : MUX-A22WV -
NOTE Q :Total capacity (kW) SHF :Sensible heat factor DB :Dry-bulb temperature
SHC :Sensible heat capacity (kW) INPUT :Total power input (W) WB :Wet-bulb temperature
11
E1E1
Page 12
PERFORMANCE DATA
21 18 3.43 1.88 0.55 1294 3.15 1.72 0.55 1373 3.03 1.66 0.55 1399 21 20 3.61 1.54 0.43 1346 3.36 1.43 0.43 1412 3.24 1.38 0.43 1452 22 18 3.43 2.01 0.59 1294 3.15 1.85 0.59 1373 3.03 1.78 0.59 1399 22 20 3.61 1.68 0.47 1346 3.36 1.57 0.47 1412 3.24 1.51 0.47 1452 22 22 3.82 1.32 0.35 1399 3.57 1.24 0.35 1478 3.45 1.20 0.35 1505 23 18 3.43 2.15 0.63 1294 3.15 1.98 0.63 1373 3.03 1.90 0.63 1399 23 20 3.61 1.83 0.51 1346 3.36 1.70 0.51 1412 3.24 1.64 0.51 1452 23 22 3.82 1.48 0.39 1399 3.57 1.38 0.39 1478 3.45 1.33 0.39 1505 24 18 3.43 2.29 0.67 1294 3.15 2.10 0.67 1373 3.03 2.02 0.67 1399 24 20 3.61 1.97 0.55 1346 3.36 1.84 0.55 1412 3.24 1.77 0.55 1452 24 22 3.82 1.63 0.43 1399 3.57 1.52 0.43 1478 3.45 1.47 0.43 1505 24 24 4.03 1.24 0.31 1452 3.78 1.16 0.31 1518 3.68 1.13 0.31 1551 25 18 3.43 2.43 0.71 1294 3.15 2.23 0.71 1373 3.03 2.14 0.71 1399 25 20 3.61 2.12 0.59 1346 3.36 1.97 0.59 1412 3.24 1.90 0.59 1452 25 22 3.82 1.78 0.47 1399 3.57 1.67 0.47 1478 3.45 1.61 0.47 1505 25 24 4.03 1.40 0.35 1452 3.78 1.31 0.35 1518 3.68 1.28 0.35 1551 26 18 3.43 2.56 0.75 1294 3.15 2.35 0.75 1373 3.03 2.26 0.75 1399 26 20 3.61 2.26 0.63 1346 3.36 2.11 0.63 1412 3.24 2.03 0.63 1452 26 22 3.82 1.93 0.51 1399 3.57 1.81 0.51 1478 3.45 1.75 0.51 1505 26 24 4.03 1.56 0.39 1452 3.78 1.46 0.39 1518 3.68 1.42 0.39 1551 26 26 4.24 1.13 0.27 1505 3.99 1.07 0.27 1571 3.87 1.03 0.27 1604 27 18 3.43 2.70 0.79 1294 3.15 2.48 0.79 1373 3.03 2.38 0.79 1399 27 20 3.61 2.40 0.67 1346 3.36 2.24 0.67 1412 3.24 2.16 0.67 1452 27 22 3.82 2.09 0.55 1399 3.57 1.95 0.55 1478 3.45 1.89 0.55 1505 27 24 4.03 1.72 0.43 1452 3.78 1.61 0.43 1518 3.68 1.57 0.43 1551 27 26 4.24 1.30 0.31 1505 3.99 1.22 0.31 1571 3.87 1.19 0.31 1604 28 18 3.43 2.84 0.83 1294 3.15 2.61 0.83 1373 3.03 2.50 0.83 1399 28 20 3.61 2.55 0.71 1346 3.36 2.38 0.71 1412 3.24 2.29 0.71 1452 28 22 3.82 2.24 0.59 1399 3.57 2.10 0.59 1478 3.45 2.02 0.59 1505 28 24 4.03 1.88 0.47 1452 3.78 1.77 0.47 1518 3.68 1.72 0.47 1551 28 26 4.24 1.47 0.35 1505 3.99 1.38 0.35 1571 3.87 1.34 0.35 1604 29 18 3.43 2.97 0.87 1294 3.15 2.73 0.87 1373 3.03 2.62 0.87 1399 29 20 3.61 2.69 0.75 1346 3.36 2.51 0.75 1412 3.24 2.42 0.75 1452 29 22 3.82 2.39 0.63 1399 3.57 2.24 0.63 1478 3.45 2.16 0.63 1505 29 24 4.03 2.04 0.51 1452 3.78 1.92 0.51 1518 3.68 1.86 0.51 1551 29 26 4.24 1.64 0.39 1505 3.99 1.54 0.39 1571 3.87 1.50 0.39 1604 30 18 3.43 3.11 0.91 1294 3.15 2.86 0.91 1373 3.03 2.75 0.91 1399 30 20 3.61 2.84 0.79 1346 3.36 2.64 0.79 1412 3.24 2.55 0.79 1452 30 22 3.82 2.54 0.67 1399 3.57 2.38 0.67 1478 3.45 2.30 0.67 1505 30 24 4.03 2.20 0.55 1452 3.78 2.07 0.55 1518 3.68 2.01 0.55 1551 30 26 4.24 1.81 0.43 1505 3.99 1.70 0.43 1571 3.87 1.65 0.43 1604 31 18 3.43 3.25 0.95 1294 3.15 2.98 0.95 1373 3.03 2.87 0.95 1399 31 20 3.61 2.98 0.83 1346 3.36 2.78 0.83 1412 3.24 2.68 0.83 1452 31 22 3.82 2.70 0.71 1399 3.57 2.52 0.71 1478 3.45 2.44 0.71 1505 31 24 4.03 2.36 0.59 1452 3.78 2.22 0.59 1518 3.68 2.16 0.59 1551 31 26 4.24 1.98 0.47 1505 3.99 1.86 0.47 1571 3.87 1.81 0.47 1604 32 18 3.43 3.39 0.99 1294 3.15 3.11 0.99 1373 3.03 2.99 0.99 1399 32 20 3.61 3.13 0.87 1346 3.36 2.91 0.87 1412 3.24 2.81 0.87 1452 32 22 3.82 2.85 0.75 1399 3.57 2.67 0.75 1478 3.45 2.58 0.75 1505 32 24 4.03 2.52 0.63 1452 3.78 2.37 0.63 1518 3.68 2.30 0.63 1551 32 26 4.24 2.15 0.51 1505 3.99 2.02 0.51 1571 3.87 1.96 0.51 1604
CAPACITY : 3.5(kW) SHF : 0.73 INPUT : 1320(W)
OUTDOOR DB(:)
INDOOR
INDOOR
DB(:)
WB(:)
Q
SHC
SHF
INPUT
Q
SHC SHF INPUT Q SHC SHF INPUT
35 40 43
COOL operation (230V)
MSC-A12WV - (Single : Room A) : MUX-A22WV -
NOTE Q :Total capacity (kW) SHF :Sensible heat factor DB :Dry-bulb temperature
SHC :Sensible heat capacity (kW) INPUT :Total power input (W) WB :Wet-bulb temperature
12
E1E1
Page 13
PERFORMANCE DATA
21 18 2.82 1.58 0.56 680 2.70 1.51 0.56 714 2.59 1.45 0.56 748 2.50 1.40 0.56 782 21 20 2.94 1.29 0.44 714 2.82 1.24 0.44 757 2.74 1.20 0.44 774 2.64 1.16 0.44 808 22 18 2.82 1.69 0.60 680 2.70 1.62 0.60 714 2.59 1.56 0.60 748 2.50 1.50 0.60 782 22 20 2.94 1.41 0.48 714 2.82 1.35 0.48 757 2.74 1.31 0.48 774 2.64 1.27 0.48 808 22 22 3.06 1.10 0.36 740 2.95 1.06 0.36 786 2.88 1.04 0.36 808 2.76 0.99 0.36 842 23 18 2.82 1.80 0.64 680 2.70 1.73 0.64 714 2.59 1.66 0.64 748 2.50 1.60 0.64 782 23 20 2.94 1.53 0.52 714 2.82 1.47 0.52 757 2.74 1.42 0.52 774 2.64 1.37 0.52 808 23 22 3.06 1.22 0.40 740 2.95 1.18 0.40 786 2.88 1.15 0.40 808 2.76 1.10 0.40 842 24 18 2.82 1.92 0.68 680 2.70 1.84 0.68 714 2.59 1.76 0.68 748 2.50 1.70 0.68 782 24 20 2.94 1.65 0.56 714 2.82 1.58 0.56 757 2.74 1.53 0.56 774 2.64 1.48 0.56 808 24 22 3.06 1.35 0.44 740 2.95 1.30 0.44 786 2.88 1.27 0.44 808 2.76 1.21 0.44 842 24 24 3.22 1.03 0.32 774 3.10 0.99 0.32 816 3.02 0.97 0.32 842 2.93 0.94 0.32 884 25 18 2.82 2.03 0.72 680 2.70 1.94 0.72 714 2.59 1.87 0.72 748 2.50 1.80 0.72 782 25 20 2.94 1.76 0.60 714 2.82 1.69 0.60 757 2.74 1.64 0.60 774 2.64 1.58 0.60 808 25 22 3.06 1.47 0.48 740 2.95 1.42 0.48 786 2.88 1.38 0.48 808 2.76 1.32 0.48 842 25 24 3.22 1.16 0.36 774 3.10 1.11 0.36 816 3.02 1.09 0.36 842 2.93 1.05 0.36 884 26 18 2.82 2.14 0.76 680 2.70 2.05 0.76 714 2.59 1.97 0.76 748 2.50 1.90 0.76 782 26 20 2.94 1.88 0.64 714 2.82 1.80 0.64 757 2.74 1.75 0.64 774 2.64 1.69 0.64 808 26 22 3.06 1.59 0.52 740 2.95 1.54 0.52 786 2.88 1.50 0.52 808 2.76 1.44 0.52 842 26 24 3.22 1.29 0.40 774 3.10 1.24 0.40 816 3.02 1.21 0.40 842 2.93 1.17 0.40 884 26 26 3.31 0.93 0.28 816 3.22 0.90 0.28 859 3.17 0.89 0.28 884 3.07 0.86 0.28 910 27 18 2.82 2.26 0.80 680 2.70 2.16 0.80 714 2.59 2.07 0.80 748 2.50 2.00 0.80 782 27 20 2.94 2.00 0.68 714 2.82 1.92 0.68 757 2.74 1.86 0.68 774 2.64 1.80 0.68 808 27 22 3.06 1.71 0.56 740 2.95 1.65 0.56 786 2.88 1.61 0.56 808 2.76 1.55 0.56 842 27 24 3.22 1.42 0.44 774 3.10 1.36 0.44 816 3.02 1.33 0.44 842 2.93 1.29 0.44 884 27 26 3.31 1.06 0.32 816 3.22 1.03 0.32 859 3.17 1.01 0.32 884 3.07 0.98 0.32 910 28 18 2.82 2.37 0.84 680 2.70 2.27 0.84 714 2.59 2.18 0.84 748 2.50 2.10 0.84 782 28 20 2.94 2.12 0.72 714 2.82 2.03 0.72 757 2.74 1.97 0.72 774 2.64 1.90 0.72 808 28 22 3.06 1.84 0.60 740 2.95 1.77 0.60 786 2.88 1.73 0.60 808 2.76 1.66 0.60 842 28 24 3.22 1.54 0.48 774 3.10 1.49 0.48 816 3.02 1.45 0.48 842 2.93 1.41 0.48 884 28 26 3.31 1.19 0.36 816 3.22 1.16 0.36 859 3.17 1.14 0.36 884 3.07 1.11 0.36 910 29 18 2.82 2.48 0.88 680 2.70 2.38 0.88 714 2.59 2.28 0.88 748 2.50 2.20 0.88 782 29 20 2.94 2.23 0.76 714 2.82 2.14 0.76 757 2.74 2.08 0.76 774 2.64 2.01 0.76 808 29 22 3.06 1.96 0.64 740 2.95 1.89 0.64 786 2.88 1.84 0.64 808 2.76 1.77 0.64 842 29 24 3.22 1.67 0.52 774 3.10 1.61 0.52 816 3.02 1.57 0.52 842 2.93 1.52 0.52 884 29 26 3.31 1.32 0.40 816 3.22 1.29 0.40 859 3.17 1.27 0.40 884 3.07 1.23 0.40 910 30 18 2.82 2.59 0.92 680 2.70 2.48 0.92 714 2.59 2.38 0.92 748 2.50 2.30 0.92 782 30 20 2.94 2.35 0.80 714 2.82 2.26 0.80 757 2.74 2.19 0.80 774 2.64 2.11 0.80 808 30 22 3.06 2.08 0.68 740 2.95 2.01 0.68 786 2.88 1.96 0.68 808 2.76 1.88 0.68 842 30 24 3.22 1.80 0.56 774 3.10 1.73 0.56 816 3.02 1.69 0.56 842 2.93 1.64 0.56 884 30 26 3.31 1.46 0.44 816 3.22 1.42 0.44 859 3.17 1.39 0.44 884 3.07 1.35 0.44 910 31 18 2.82 2.71 0.96 680 2.70 2.59 0.96 714 2.59 2.49 0.96 748 2.50 2.40 0.96 782 31 20 2.94 2.47 0.84 714 2.82 2.37 0.84 757 2.74 2.30 0.84 774 2.64 2.22 0.84 808 31 22 3.06 2.20 0.72 740 2.95 2.13 0.72 786 2.88 2.07 0.72 808 2.76 1.99 0.72 842 31 24 3.22 1.93 0.60 774 3.10 1.86 0.60 816 3.02 1.81 0.60 842 2.93 1.76 0.60 884 31 26 3.31 1.59 0.48 816 3.22 1.54 0.48 859 3.17 1.52 0.48 884 3.07 1.47 0.48 910 32 18 2.82 2.82 1.00 680 2.70 2.70 1.00 714 2.59 2.59 1.00 748 2.50 2.50 1.00 782 32 20 2.94 2.59 0.88 714 2.82 2.48 0.88 757 2.74 2.41 0.88 774 2.64 2.32 0.88 808 32 22 3.06 2.33 0.76 740 2.95 2.24 0.76 786 2.88 2.19 0.76 808 2.76 2.10 0.76 842 32 24 3.22 2.06 0.64 774 3.10 1.98 0.64 816 3.02 1.94 0.64 842 2.93 1.87 0.64 884 32 26 3.31 1.72 0.52 816 3.22 1.67 0.52 859 3.17 1.65 0.52 884 3.07 1.60 0.52 910
CAPACITY : 2.4(kW) SHF : 0.74 INPUT : 850(W)
OUTDOOR DB(:)
INDOOR
INDOOR
25 27 30
DB(:)
WB(:)
Q
SHC
SHF
INPUT
Q
SHC SHF INPUT Q SHC SHF INPUT Q SHC SHF INPUT
21
COOL operation (230V)
MSC-A07WV - (Single : Room B or C) : MUX-A22WV -
NOTE Q :Total capacity (kW) SHF :Sensible heat factor DB :Dry-bulb temperature
SHC :Sensible heat capacity (kW) INPUT :Total power input (W) WB :Wet-bulb temperature
13
E1E1
Page 14
PERFORMANCE DATA
21 18 2.35 1.32 0.56 833 2.16 1.21 0.56 884 2.08 1.16 0.56 901 21 20 2.47 1.09 0.44 867 2.30 1.01 0.44 910 2.22 0.98 0.44 935 22 18 2.35 1.41 0.60 833 2.16 1.30 0.60 884 2.08 1.25 0.60 901 22 20 2.47 1.19 0.48 867 2.30 1.11 0.48 910 2.22 1.07 0.48 935 22 22 2.62 0.94 0.36 901 2.45 0.88 0.36 952 2.36 0.85 0.36 969 23 18 2.35 1.51 0.64 833 2.16 1.38 0.64 884 2.08 1.33 0.64 901 23 20 2.47 1.29 0.52 867 2.30 1.20 0.52 910 2.22 1.15 0.52 935 23 22 2.62 1.05 0.40 901 2.45 0.98 0.40 952 2.36 0.95 0.40 969 24 18 2.35 1.60 0.68 833 2.16 1.47 0.68 884 2.08 1.41 0.68 901 24 20 2.47 1.38 0.56 867 2.30 1.29 0.56 910 2.22 1.24 0.56 935 24 22 2.62 1.15 0.44 901 2.45 1.08 0.44 952 2.36 1.04 0.44 969 24 24 2.76 0.88 0.32 935 2.59 0.83 0.32 978 2.52 0.81 0.32 999 25 18 2.35 1.69 0.72 833 2.16 1.56 0.72 884 2.08 1.49 0.72 901 25 20 2.47 1.48 0.60 867 2.30 1.38 0.60 910 2.22 1.33 0.60 935 25 22 2.62 1.26 0.48 901 2.45 1.18 0.48 952 2.36 1.13 0.48 969 25 24 2.76 0.99 0.36 935 2.59 0.93 0.36 978 2.52 0.91 0.36 999 26 18 2.35 1.79 0.76 833 2.16 1.64 0.76 884 2.08 1.58 0.76 901 26 20 2.47 1.58 0.64 867 2.30 1.47 0.64 910 2.22 1.42 0.64 935 26 22 2.62 1.36 0.52 901 2.45 1.27 0.52 952 2.36 1.23 0.52 969 26 24 2.76 1.10 0.40 935 2.59 1.04 0.40 978 2.52 1.01 0.40 999 26 26 2.90 0.81 0.28 969 2.74 0.77 0.28 1012 2.65 0.74 0.28 1033 27 18 2.35 1.88 0.80 833 2.16 1.73 0.80 884 2.08 1.66 0.80 901 27 20 2.47 1.68 0.68 867 2.30 1.57 0.68 910 2.22 1.51 0.68 935 27 22 2.62 1.46 0.56 901 2.45 1.37 0.56 952 2.36 1.32 0.56 969 27 24 2.76 1.21 0.44 935 2.59 1.14 0.44 978 2.52 1.11 0.44 999 27 26 2.90 0.93 0.32 969 2.74 0.88 0.32 1012 2.65 0.85 0.32 1033 28 18 2.35 1.98 0.84 833 2.16 1.81 0.84 884 2.08 1.74 0.84 901 28 20 2.47 1.78 0.72 867 2.30 1.66 0.72 910 2.22 1.60 0.72 935 28 22 2.62 1.57 0.60 901 2.45 1.47 0.60 952 2.36 1.42 0.60 969 28 24 2.76 1.32 0.48 935 2.59 1.24 0.48 978 2.52 1.21 0.48 999 28 26 2.90 1.05 0.36 969 2.74 0.98 0.36 1012 2.65 0.95 0.36 1033 29 18 2.35 2.07 0.88 833 2.16 1.90 0.88 884 2.08 1.83 0.88 901 29 20 2.47 1.88 0.76 867 2.30 1.75 0.76 910 2.22 1.69 0.76 935 29 22 2.62 1.67 0.64 901 2.45 1.57 0.64 952 2.36 1.51 0.64 969 29 24 2.76 1.44 0.52 935 2.59 1.35 0.52 978 2.52 1.31 0.52 999 29 26 2.90 1.16 0.40 969 2.74 1.09 0.40 1012 2.65 1.06 0.40 1033 30 18 2.35 2.16 0.92 833 2.16 1.99 0.92 884 2.08 1.91 0.92 901 30 20 2.47 1.98 0.80 867 2.30 1.84 0.80 910 2.22 1.78 0.80 935 30 22 2.62 1.78 0.68 901 2.45 1.66 0.68 952 2.36 1.61 0.68 969 30 24 2.76 1.55 0.56 935 2.59 1.45 0.56 978 2.52 1.41 0.56 999 30 26 2.90 1.28 0.44 969 2.74 1.20 0.44 1012 2.65 1.17 0.44 1033 31 18 2.35 2.26 0.96 833 2.16 2.07 0.96 884 2.08 1.99 0.96 901 31 20 2.47 2.08 0.84 867 2.30 1.94 0.84 910 2.22 1.86 0.84 935 31 22 2.62 1.88 0.72 901 2.45 1.76 0.72 952 2.36 1.70 0.72 969 31 24 2.76 1.66 0.60 935 2.59 1.56 0.60 978 2.52 1.51 0.60 999 31 26 2.90 1.39 0.48 969 2.74 1.31 0.48 1012 2.65 1.27 0.48 1033 32 18 2.35 2.35 1.00 833 2.16 2.16 1.00 884 2.08 2.08 1.00 901 32 20 2.47 2.18 0.88 867 2.30 2.03 0.88 910 2.22 1.95 0.88 935 32 22 2.62 1.99 0.76 901 2.45 1.86 0.76 952 2.36 1.80 0.76 969 32 24 2.76 1.77 0.64 935 2.59 1.66 0.64 978 2.52 1.61 0.64 999 32 26 2.90 1.51 0.52 969 2.74 1.42 0.52 1012 2.65 1.38 0.52 1033
CAPACITY : 2.4(kW) SHF : 0.74 INPUT : 850(W)
OUTDOOR DB(:)
INDOOR
INDOOR
DB(:)
WB(:)
Q
SHC
SHF
INPUT
Q
SHC SHF INPUT Q SHC SHF INPUT
35 40 43
COOL operation (230V)
MSC-A07WV - (Single : Room B or C) : MUX-A22WV -
NOTE Q :Total capacity (kW) SHF :Sensible heat factor DB :Dry-bulb temperature
SHC :Sensible heat capacity (kW) INPUT :Total power input (W) WB :Wet-bulb temperature
14
E1E1
Page 15
10
ACTUATOR
ON OFF
ON
OFF ON
OFF ON (OPEN) OFF (CLOSE) ON (OPEN) OFF (CLOSE)
ON (CLOSE)
OFF (OPEN)
SOLENOID VALVE
INDOOR UNIT
MC1
MC2
MF61
21R3
21R4
21RB
COMPRESSOR
OUTDOOR FAN MOTOR
A
ON
OFF
– – – –
OFF
– – – – – – – –
B
– ON ON
OFF OFF
ANY UNIT ON
OFF
ON
OFF
– ON ON
OFF OFF
C –
ON
OFF
ON
OFF
OFF
– –
ON
OFF
ON
OFF
ON
OFF
MUX-A22WV - E1
“–” means that the indoor unit is not related to the control of actuator.
Lead wiring
Housing point
MICROPROCESSOR CONTROL
MUX-A22WV -
E1
OUTDOOR UNIT ACTUATOR CONTROL
11
MUX-A22WV -
TROUBLESHOOTING
E1
11-1. Cautions on troubleshooting
1. Before troubleshooting, check the following:
1) Check the power supply voltage.
2) Check the indoor/outdoor connecting wire for mis-wiring.
2. Take care the following during servicing.
1) Before servicing the air conditioner, first be sure to turn off the remote controller to stop the unit, and then after con­firming the horizontal vane is closed, turn off the breaker and/or disconnect the power plug.
2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic control P.C. board.
3) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the components.
4) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
3. Troubleshooting procedure
1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality.
To make sure, check how many times the abnormality indication is flashing on and off before starting service work.
2) If the electronic control P.C. board is supposed to be defective, check the copper foil pattern for disconnection and the
components for bursting and discoloration.
3) When troubleshooting, refer to the flow chart on page 16.
15
Page 16
11-2. Instruction of troubleshooting
Start
Indoor unit operates. Outdoor unit doesn't operate.
Indoor unit doesn't receive the signal from remote controller.
Indoor unit operates. But indoor unit doesn't blow out cool air.
Indoor unit operates. Outdoor unit doesn't operate normally.
OPERATION INDICATOR lamp on the indoor unit is flashing on and off.
Outdoor unit operates in only Test Run operation.
Outdoor unit doesn't operate even in Test Run operation.
Indoor unit operates, when the EMERGENCY OPERATION switch is pressed.
Indoor unit doesn't operate, when the EMERGENCY OPERATION switch is pressed.
Check room temperature thermistor. Refer to "Test point diagram and voltage".
Refer to A "Check of outdoor unit" on page 18.
Refer to "Check of remote controller and receiver P.C. board".
Flash on and off at 0.5-second intervals Cause: Wrong setting of switch (SW2-2) on the electronic control P.C. board.
2-time flash Cause: Indoor unit
• Trouble of room temp­ erature/ indoor coil thermistor
3-time flash Cause: Indoor unit
• Trouble of indoor fan motor
Check room temperature thermistor and indoor coil thermis­tor. Refer to "Test point diagram and voltage".
Refer to "Check of indoor fan motor".
Refer to C "Check of MU & MUX TYPE / MUH & MXZ TYPE SWITCH OVER " (When outdoor unit doesn't work.) on page 19.
1. Check indoor / outdoor connecting wire.
2. Refer to "Check of indoor electronic control P.C. board".
Outdoor unit doesn't stop even if indoor unit stops.
Refer to B "Check of outdoor unit" on page 19.
Refer to D "Check of indoor / outdoor units' connection and outdoor unit" on page 19.
As for indoor unit, refer to service manual OB307 REVISED EDITION-A.
MUX-A22WV -
E1
16
Page 17
P
MUX-A22WV -
BLK
RED
WHT
P
E1
Part name
Compressor (MC1, MC2) INNER PROTECTOR 150°C OPEN
90°C CLOSE
Outdoor fan motor
(MF61) INNER
PROTECTOR 145i8°C OPEN
Solenoid coil
21RB, 21R3, 21R4
Check method and criterion
Measure the resistance between the terminals with a tester. (Coil wiring temperature-10°C ~ 40°C)
C-R
C-S
RN145VHSHT
2.14 ~ 2.63
3.35 ~ 4.11
Normal
RN092VHSHT
3.41 ~ 4.18
5.41 ~ 6.63
Ω Ω
Abnormal
short-circuit
Measure the resistance between the terminals with a tester. (Coil wiring temperature -10°C ~ 40°C)
Color of lead
wire
WHT-BLK
BLK-RED
Normal Abnormal
79 ~ 98
129 ~ 158
Open or
short-circuit
Measure the resistance with a tester. (Part temperature -10°C ~ 40°C)
Normal
1410 ~ 1730
Abnormal
Open or short-circuit
Figure
Open or
P Inner protector
17
Page 18
No
Start
Press the EMERGENCY OPEERATION switch of all indoor units.
Yes
Is there 230V AC between L
- N
on the TB1
of outdoor unit?
No
Is fuse(F61) on the outdoor control P.C. board blown?
Check and rectify the connecting wire of indoor and outdoor unit.
3 minutes later, is there 12V DC between 1 - 2 on the all terminal blocks of outdoor unit?
Is there 10~15V DC between JP20 DC12V and JP19 GND on outdoor control P.C. board?
Fan motor doesn't operate.
Compressor doesn't operate.
Yes
Yes
Turn OFF the power supply to outdoor unit.
Does outdoor control P.C. board connect with outdoor fan capacitor C61?
Yes
Connect the outdoor control P.C. board with outdoor fan capacitor C61.
Disconnect connector of outdoor fan motor CN91 and outdoor fan capacitor C61.
Replace the outdoor fan motor.
Replace the outdoor control P.C. board.
No
Yes
Turn OFF the power supply.
Replace the outdoor control P.C. board.
No
Disconnect connector of outdoor fan motor CN91 and outdoor fan capacitor C61.
Is the resistance 0" or between the lead wire WHT and BLK of outdoor fan motor, or between the lead wire RED and BLK of outdoor fan motor? (Refer to page 17.)
Yes
Replace the outdoor fan motor and fuse(F61).
No
Check the power supply and connecting wire.
No
Is there 12V DC between
1
- 2
on the terminal
block of each indoor unit?
No
Short both terminal of fuse(F61).
Yes
Is the resistance 0" between the fuse(F61) and the terminal of CN903?
Replace the outdoor control P.C. board.
Yes
Replace the fuse(F61).
No
No
Check the indoor unit.
Yes
Turn OFF the power supply to outdoor unit. Disconnect connecting wire of X521 and X522 from outdoor control P.C. board. Insulate terminal of connecting wires to prevent contact of other parts. Turn ON the power supply to outdoor unit. Press the EMERGENCY OPERATION switch of all indoor unit.
Is the resistance 0" or between the terminal C and R of MC1, and between the terminal C and S of MC1? (Refer to page 17.)
3 minutes later, is the resistance 0" between the terminal 3 and 4 of X521 on outdoor control P.C. board, and between the terminal 3 and 4 of X522 on outdoor control P.C. board?
Turn OFF the power supply to outdoor unit.
Yes
Replace the compressor MC1.
No
Replace the compressor MC2.
No
Check and rectify the connecting wire of terminal and compressor.
Turn OFF the power supply to outdoor unit.
No
Replace the outdoor control P.C. board.
Is the resistance 0" or between the terminal C and R of MC2, and between the terminal C and S of MC2? (Refer to page 17.)
Yes
Yes
Is the resistance 0" or between the lead wire WHT and BLK of outdoor fan motor, or between the lead wire RED and BLK of outdoor fan motor? (Refer to page 17.)
Measure resistance all the solenoid coil.
Is resistance 0"?
Replace the solenoid coil.
Yes
No
Compressor and / or outdoor fan doesn’t operate.
AA
Check of outdoor unit
18
Page 19
Compressor and / or outdoor fan doesn’t stop.
Turn ON the power supply, and operate all the indoor units at a time.
Yes
No
Operate the indoor unit one by one, and measure the voltage between 1 and 2 of outdoor terminal block for each indoor unit. Match the signs of terminal block whose voltage is 12V DC and pipe of indoor/ outdoor units' connection. w1.
Do they perform the cooling operation?
Start
Indoor unit
Model
Terminal block
Connector for
solenoid coil control B C
TB3 TB4
21R3-CN85 21R4-CN86
21RB-CN81
w1. If the pipe of indoor unit that does not operate is cooled though the combination of pipe and connecting wire is correct, check the solenoid coil. Refer to page 7.
Turn OFF the power supply. Remove solenoid coil's connector that corresponds to the indoor unit, which does not blow out cool air. Then, measure the resistance of solenoid coil.
Do the resistance value normal? (Refer to page 17.)
Yes
Reconnect solenoid coil's connector. Then turn the main power on and operate the indoor unit that does not blow out cool air. Measure the voltage of solenoid coil's connector that corresponds to the indoor unit, which is operated.
Replace the solenoid coil.
No
Is voltage 230V?
Yes
No
OK
MUX-A22WV
Replace the outdoor control P.C. board.
BB
Check of outdoor unit
Start
Turn OFF the power supply. After 1 minute, turn ON power supply again.
Is there 12V DC between
Does compressor or outdoor fan motor stop?
Yes
OK
No
12 on the outdoor terminal block (TB2 or TB3)?
Replace the indoor electoronic control P.C. board.
Yes
No
Replace the outdoor control P.C. board.
When OPERATION INDICATOR lamp flashes 0.5-second intervals. Outdoor unit doesn’t operate.
CC
Check of MU & MUX TYPE / MUH & MXZ TYPE SWITCH OVER
Start
Turn OFF the power supply (indoor / outdoor unit).
Set switch (SW2-2) on the indoor electronic control P.C. board to MUX type.
Does the unit operate?
Refer to the "Instruction of troubleshooting."
No
w1
Yes
OK
Cool air doesn’t blow out although indoor unit is operating.
DD
Check of indoor / outdoor units’ connection and outdoor unit
w In case of troubleshooting, be sure to operate indoor unit by emergency operation switch.
w 1 Set the switch (SW2-2) on indoor electronic control P.C. board to
MUX type, when the outdoor unit is MUX type. If the setting is MUH or MXZ type, the unit does not work. Refer to 12-6. MU & MUX TYPE / MUH& MXZ TYPE SWITCH OVER AND AUTO RESTART FUNCTION on service manual OB307 REVISED EDITON-A.
19
Page 20
TEST POINT DIAGRAM AND VOLTAGE MUX-A22WV -
E1
Outdoor control P.C. board
To fan capacitor C61
From indoor unit A 12V DC 1+, 3-
From indoor unit B 12V DC 1+, 3-
From indoor unit C 12V DC 1+, 3-
To fan motor 230V AC 50Hz
BLK
WHT
JP20 DC12V JP19 GND
+
}
12V DC
To fan capacitor C61
To indoor unit B Solenoid coil 21R3 230V AC 50Hz
To indoor unit C Solenoid coil 21R4 230V AC 50Hz
Fuse 250V AC
3.15A
To solenoid coil 21RB 230V AC 50Hz
Terminal 4 of X521
Terminal 3 of X521
Terminal 4 of X522
Terminal 3 of X522
Power supply input 230V AC 50Hz
Surge absorber NR61
20
Page 21
12
(1) Slide the sleeve and check if there is a locking lever or not. (2) The terminal with this connector is a terminal
with lock mechanism
1Slide the sleeve. 2Pull the terminal while
pushing the locking lever.
1Hold the sleeve, and pull out the terminal slowly.
In case of terminal with lock mechanism, detach the terminal as shown below. There are two types ( Refer to (1) and (2)) of the terminal with lock mechanism. The terminal with no lock mechanism can be removed by pulling it out. Check the shape of the terminal and work.
<"Terminal with lock mechanism" Detaching points>
Connector
Sleeve
Locking lever
DISASSEMBLY INSTRUCTIONS
12-1. MUX-A22WV -
E1
OUTDOOR UNIT
OPERATING PROCEDURE PHOTOS
1.Removing the cabinet
(1) Remove the screws of the top panel. (2) Remove the screws of the service panel. (3) Remove the top panel. (4) Remove the service panel. (5) Remove the screws of the front panel. (6) Remove the front panel. (7) Remove the screws of the back panel. (8) Remove the back panel.
Photo 3
Back panel
Photo 1
Set screws of the front panel
Photo 2
Top panel
Front panel
Set screws of the front panel
Set screws of the top panel
Set screws of the back panel
Set screws of the front panel
21
Service panel
Set screws of the ser­vice panel
Set screws of the back panel
Page 22
OPERATING PROCEDURE PHOTOS
2. Removing the relay panel
(1) Remove the cabinet. (Refer to 1.) (2) Disconnect the following connectors.
.
Outdoor fan motor
.
Solenoid coil (21RB, 21R3, 21R4)
3. Removing the propeller
(1) Remove the cabinet. (Refer to 1.) (2) Remove the propeller nut. (3) Remove the propeller.
NOTE : Loose the propeller in the rotating direction for
removal.
When attaching the propeller, align the mark on the propeller and the motor shaft cut section. Set the propeller in position by using the cut on the shaft and the mark on the propeller.
4. Removing the outdoor fan motor
(1) Remove the cabinet. (Refer to 1.) (2) Remove the propeller. (Refer to 3.) (3) Remove the clamp of outdoor fan motor lead wire and
disconnect the outdoor fan motor connector. (4) Remove the screws fixing the outdoor fan motor. (5) Remove the outdoor fan motor.
Photo 4
Set screws of the outdoor fan motor
Back panel
Outdoor fan motor
Propeller
Solenoid coil connector (21RB, 21R3, 21R4)
Outdoor fan
motor connector Set screws of the relay panel
Clamp
Propeller nut
Set screws of the relay panel
5. Removing the compressor (A, B)
(1) Remove the cabinet. (Refer to 1.) (2) Remove the relay panel. (3) Remove the soundproof felt. (4) Remove the terminal cover on the compressor. (5) Disconnect lead wires from the compressor. (6) Recover gas from the refrigerant circuit. (7) Disconnect the welded part of the discharge pipe. (8) Disconnect the welded part of the suction pipe. (9) Remove nuts fixing the compressor.
)
(
Remove the compressor.
10
NOTE
Before using a burner, reclaim gas from the pipes until the pressure gauge shows 0 kg/cm
Use the burner under the condition that gas can be recovered even when the inner pressure rises by heat.
2
(0 MPa) .
6. Removing the compressor (C)
(1) Remove the cabinet. (Refer to 1.) (2) Remove the relay panel. (Refer to 2.) (3) Remove the screws fixing back panel. (4) Remove the back panel. (5) Remove the soundproof felt. (6) Remove the terminal cover on the compressor. (7) Disconnect lead wires from the compressor. (8) Recover gas from the refrigerant circuit. (9) Disconnect the welded part of the discharge pipe.
)
(
Disconnect the welded part of the suction pipe.
10
(11)
Remove nuts fixing the compressor.
(12)
Remove the compressor.
Photo 5
Suction pipe
Discharge pipe
Sound proof felt
Terminal cover
Terminal cover
NOTE
Before using a burner, reclaim gas from the pipes until the pressure gauge shows 0 kg/cm
Use the burner under the condition that gas can be recovered even when the inner pressure rises by heat.
2
(0 MPa) .
22
Page 23
13
PARTS LIST
MUX-A22WV -
E1
13-1. OUTDOOR UNIT STRUCTURAL PARTS
1
2
3
4
5
17
16
6
14
13
12
6
Part numbers that are circled are not shown in the illustration.
No.
Part No.
1
E02 636 297
2
E02 636 515
3
E02 756 630
4
E02 636 232
5
E02 527 521
6
E07 001 009
7
E02 742 900
8
E02 744 900 E02 289 936
9
E02 134 936
10
E02 075 506
11
E02 636 290 E02 756 661
12
E02 757 661
13
E02 756 662
14
E02 024 936
15
E02 636 245
16
E02 756 233 E02 721 009
17
E02 637 490
18
E02 652 490
19
E02 652 491
20
E02 755 492
21
E02 759 492
22
TOP PANEL MOTOR SUPPORT OUTDOOR HEAT EXCHANGER CABINET FAN GUARD HANDLE COMPRESSOR COMPRESSOR CAPILLARY TUBE CAPILLARY TUBE COMPRESSOR RUBBER SET BASE STOP VALVE (GAS) STOP VALVE (GAS) STOP VALVE (LIQ) CAPILLARY TUBE SERVICE PANEL BACK PANEL (OUT) HANDLE SOLENOID COIL SOLENOID COIL (B) SOLENOID COIL (C) SOLENOID VALVE SOLENOID VALVE
Part Name
7 8 9 10
Symbol
in Wiring
Diagram
CT1, CT3, CT4
MC2 MC1
CT2
CT5
21RB
21R3 21R4
23
11
Q'ty / unit
MUX-A22WV-
15
E1
1 1 1 1 1 2 1 1 3 1 6 1 1 2 3 1 1 1 1 1 1 1 2 1
Remarks
RN092VHSHT RN145VHSHT
[3.0O[1.6O900
[3.0O[1.6O700
3RUBBERS/SET
[12.7 [9.52 [6.35 [3.0O[1.4O1000
Page 24
MUX-A22WV -
E1
13-2. OUTDOOR UNIT
FUNCTIONAL PARTS AND ELECTRICAL PARTS
2
No.
Part No. Part Name
1
E02 756 301
2
E02 214 501
3
E02 757 444
4
E02 085 385 E02 637 374
5
E02 637 377
6
E02 756 374
7
E02 138 351
8
E02 127 382
9
E02 742 353
10
E02 667 353
11
E02 128 383
12
E07 056 374
1
OUTDOOR FAN MOTOR PROPELLER OUTDOOR CONTROL P.C. BOARD SURGE ABSORBER TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK OUTDOOR FAN CAPACITOR FUSE COMPRESSOR CAPACITOR COMPRESSOR CAPACITOR SURGE ABSORBER TERMINAL BLOCK
12
11
10
9
8
7
6
B
A
35
Symbol
in Wiring
Diagram
MF61
NR61
TB2 TB3 TB1 C61
F61
C2 C1
DSAR
TB4
4
Q'ty / unit
MUX-A22WV-
1 1 1 1 1 1 1 1 1 1 1 1 1
E1
Remarks
RA6V60-
4P FIGURE A 3P FIGURE B 3P
3.0+/440V AC
3.15A 20+/450V AC 30+/450V AC
HEAD OFFICE: MITSUBISHI DENKI BLDG.,2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO100-8310, JAPAN
CC
Copyright 2003 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD Distributed in Oct. 2003. No.OB318 7 Made in Japan
New publication, effective Oct. 2003 Specifications subject to change without notice.