Mitsubishi MSZ-FE09NA-8, MSZ-FE12NA, MSZ-FE12NA-8 Installation Guide

Ar lk MITSUBISHI
ELECTRIC
SPLIT-TYPE AIR CONDITIONERS
INSTALLATION MANUAL
JG79A230H03
MSZ-FE09/12NA
When installing multi units, refer to the installation manual of the multi
|Phillips screwdriver 5/32 in. (4 mm) hexagonal wrench |Level Flare tool for R410A |Scale Gauge manifold for R410A |Utility knife or scissors Vacuum pump for R410A [" Required Tools for Installation
|2-9/16 in. (65 mm) hole saw Charge hose for R410A |Torque wrench Pipe cutter with reamer _Wrench (or spanner)
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
Be sure to read these safety precautions and instructions.
Be sure to observe the warnings and cautions specified here.
After reading this manual, be sure to store it with the OPERATING INSTRUCTIONS for future reference.
Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system.
[] Do not install the unit by yourself (user).
Improper or incomplete installation could cause fire, electric shock, injury due to the unit falling, or water leakage. Consult a qualified installer or the dealer from whom you purchased the unit.
[] Follow the instructions detailed in the installation manual.
Incomplete installation could cause fire or electric shock, injury due to the unit fall- ing, or leakage of water.
[] Install the unit securely in a place that can bear the weight of the unit.
If the installation location cannot bear the weight of the unit, the unit could fall causing injury.
[] Perform electrical work according to the installation manual and be sure to use
an exclusive circuit. Do not connect other electrical appliances to the circuit. If the capacity of the power circuit is insufficient or there is incomplete electrical
work, it could result in a fire or an electric shock.
[] Ground the unit correctly.
Do not connect the ground wire to a gas pipe, water pipe, lightning rod or tel- ephone ground. Defective grounding could cause electric shock.
[] Do not damage the wires.
Damaged wires could cause fire.
[] Be sure to shut off the main power when setting up the indoor P.O. hoard or
wiring.
Failure to do so could cause electric shock.
[] Use the specified wires to securely connect the indoor and outdoor units. At-
tach the wires firmly to avoid applying stress to the terminal block. Improper connection could cause fire.
[] Do not install the unit in a place where flammable gas may leak.
If gas leaks and accumulates around the unit, it could cause an explosion.
[] Do not use intermediate connection of the power cord or the extension cord.
Do not connect many devices to one AC outlet. It could cause a fire or an electric shock.
[] Use the parts provided or specified parts for the installation work.
The use of defective parts could cause an injury or leakage of water due to a fire, an electric shock, the unit falling, etc.
[] When plugging the power supply plug into the outlet, make sure that there is
no dust, blockage, or loose parts both in the outlet and on the plug. Verify that the power supply plug is completely inthe outlet. If there is dust, blockage, or loose parts on the power supply plug or the outlet, it could cause electric shock or fire. If loose parts are found on the power supply plug, replace it.
[] Securely attach the electrical cover to the indoor unit and the service panel to
the outdoor unit. If the electrical cover of the indoor unit and/or the service panel of the outdoor unit are
not attached securely, dust, water, etc. could collect in the unit and could cause a fire or an electric shock.
[] When installing or relocating the unit, make sure that no substance other than
the specified refrigerant (R410A) enters the refrigerant circuit. Any foreign substances in the refrigerant circuit can cause abnormal pressure rise or an explosion.
[] Do not discharge the refrigerant into the atmosphere. Check that the refrigerant gas
does not leak after installation has been completed. If refrigerant leaks during installation, ventilate the room.
If refrigerant comes in contact with a fire, harmful gas could be generated. If refrigerant gas leaks indoors, and comes into contact with the flame of a fan heater, space heater, stove, etc., harmful gases will be generated.
[] Use appropriate tools and piping materials for installation.
The pressure of R410A is 1.6 times higher than R22. Not using the appropriate tools and materials, or improper installation could cause the pipes to burst causing an injury.
[] When pumping down the refrigerant, stop the compressor before disconnecting
the refrigerant pipes. If the refrigerant pipes are disconnected while the compressor is running and the
stop valve is open, air could be drawn in and the pressure in the refrigeration cycle could become abnormally high, causing the pipes to burst.
[] When installing the unit, securely connect the refrigerant pipes before starting
the compressor. If the compressor is started before the refrigerant pipes are connected and the stop valve is open, air could be drawn in and the pressure in the refrigeration cycle could become abnormally high, causing the pipes to burst.
[] Fasten a flare nut with a torque wrench as specified in this manual.
If fastened too tight, a flare nut could break and cause refrigerant leakage.
[] install the unit according to national wiring regulations.
[] Depending on the installation area, install a Ground Fault Interrupt (GFI) circuit [] Do not touch the air inlet or the aluminum fins of the outdoor unit.
breaker. If the Ground Fault Interrupt (GFI) circuit breaker is not installed, an electric shock
could occur.
[] Perform the drainage/piping work securely according to the installation
manual. If there is defect in the drainage/piping work, water could drip from the unit, and
damage household items.
\
This could cause injury.
[] Do not install the outdoor unit where small animals may live.
If small animals enter the unit and damage its electrical parts, it could cause a malfunction, smoke emission, or fire. Keep the area around the unit clean.
1-2. SELECTING THE INSTALLATION LOCATION
D - Note: Where airflow is not blocked. In rooms where inverter type fluorescent lamps are used, Where cool air spreads over the entire room. the signal from the wireless remote controller may not be On a rigid wall to reduce the possibility of vibration, received. Where it is not exposed to direct sunlight. Where it can be easily drained. D® - At a distance 3 ft. (1 m) or more away from a TV and Where it is not overly exposed to strong winds. radio. Operation of the air conditioner may interfere with radio or TV reception. An amplifier may be re- quired for the affected device.
In a place as far away as possible from fluorescent and incandescent lights (so the infrared remote control can operate the air conditioner normally).
Where the air filter can be removed and replaced easily.
Note: Install the indoor unit high on the wall where air can dis-
tribute over the entire room.
" "0
Where it is convenient to operate and easily visible.
Where children cannot easily touch it.
Select a position about 4 ft. (1.2 m) above the floor. Check that signals from the remote controller from that position are received by the indoor unit ('beep' or 'beep beep' receiving tone sounds). Then, attach remote controller holder to a pillar or wall and install
wireless remote controller.
Where airflow is good and dustless. Where neighbours are not annoyed by operation
sound or hot air. Where rigid wall or support is available to prevent the
increase of operation sound or vibration. Where there is no risk of combustible gas leakage.
If installing the unit in a location high above the ground,
be sure to secure the unit legs.
o
Where it is at least 10 ft. (3 m) away from the antenna of TV set or radio. Operation of the air conditioner may
interfere with radio or TV reception in areas where re- ception is weak. An amplifier may be required for the
affected device.
Install the unit horizontally. Please install it in an area not affected by snowfall or blowing snow. In areas with heavy snow, please install a canopy, a pedestal and/or baffle boards.
1-3. SPECIFICATIONS
1-3-1. POWER SUPPLY AND INDOOR/OUTDOOR WIRE CONNECTION
Power should be taken from an exclusive branched circuit.
Wiring work should be based on applicable technical standards.
Wiring connections should be made following the diagram.
Securely tighten screws.
Connecting wires and the ground wire
Use solid conductor AWG14 or stranded conductor AWG14.
Use double insulated copper wire with 600 V insulation.
Use copper conductors only.
Follow local electrical codes.
Power supply cable and ground wire
Use solid or stranded conductor AWG14.
Use copper conductors only.
Follow local electrical codes.
Note:
When the indoor unit is powered from the outdoor unit, depending on local code, a disconnect switch needs to be installed to a power supply circuit.
Electrical specifications
Power supply (V, PHASE, Hz) Min. Circuit Ampacity (A)
Fan motor (F.L.A.) (A)
Power supply (V, PHASE, Hz) Max. Fuse size (time delay) (A)
Min. Circuit Ampacity (A) Fan motor (F.L.A.) (A)
Control voltage
Note:
It is advisable to make a piping loop near outdoor unit so as to reduce vibration.
For increased efficiency, install the outdoor unit in a location where continuous direct sunlight or excessive
water can be avoided as much as possible.
Note: When operating the air conditioner in low outside tem-
perature, be sure to follow the instructions described
below.
Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind.
To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall and a baffle
board on the air outlet side.
Avoid the following places for installation where air conditioner trouble is liable to occur.
Where flammable gas could leak.
Where there is an excessive amount of machine oil in the air.
Salty places such as the seaside.
Where sulfide gas is generated such as a hot spring.
Where there is high-frequency or wireless equipment.
MSZ-FE09/12NA
208/230, 1, 60
1.0
0.76
208/230, 1, 60
15 12
0.56
8.6
t (R.L.A)(A)Compressor (L.R.A) (A)
Indoor unit - Remote controller: (Wireless)
Indoor unit - Outdoor unit: DC12-24 V (Polar)
10.8
1-3-2. REFRIGERANT PIPES
To prevent condensation, insulate the two refrigerant pipes.
Refrigerant pipe bending radius must be 4 in. (100 mm) or more.
Z_ CAUTION Be sure to use the insulation of specified thickness (table on the right). Excessive insula-
tion may cause incorrect installation of the indoor unit, and too little insulation may cause condensate to form.
The unit has flared connections on both indoor and outdoor sides.
Remove the valve cover from the outdoor unit, then connect the pipe.
Refrigerant pipes are used to connect the indoor and outdoor units.
Be careful not to crush or over bend the pipe in pipe bending.
Refrigerant adjustment... If pipe length exceeds 25 ft. (7.5 m), additional refrigerant
(R410A) charge is required.
(The outdoor unit is charged with refrigerant for pipe length up to 25 ft. [7.5 m])
Outside Insulation
Pipe diameter ness thickness Insulation material
For liquid 1/4 (6.35) (0.8) 5/16 (8) Heat resistant foam
For gas 3/8 (9.52) (0.8) 5/16 (8) gravity
Pipe length 65 ft. (20 m) max. Height difference 40 ft. (12 m) max. No. of bends 10 max.
Pipe length
Refrigerant to be added
Minimum
wall thick-
inch (mm)
0.0315
0.0315
Limits
Up to 25 ft. (7.5 m) required.
Exceeding 25 ft. (7.5 m) Additional charge is required.
1.62 oz each 5 ft. (30 g/m)
plastic 0.045 Specific
No additional charge is
(Refer to the table below.)
1-4. INSTALLATION DIAGRAM
ACCESSORIES Check the following parts before installation.
<Indoor unit>
(1) Installation plate 1
Attachment screws for the installa-
(2) tion plate 5
i4 x25mm
(3) Remote controller holder 1
Screws for the remote controller
(4) holder 2
3.5 x 16 mm (Black)
(5) Battery (AAA) for (6) 2 (6) Wireless remote controller 1
(7) Felt tape (For left or left-rear piping) 1 (8) i Anti-Allergy Enzyme Filter 1
(9) Platinum deodorizing filter 1
FIELD-SUPPLIED PARTS
(A) Indoor/outdoor unit connecting wire* 1 (B) Extension pipe 1 (C) Wall hole sleeve 1 (D) Wall hole cover 1
(E) Pipe attachment strap 2 to 5 (F) Screw for (E) 4 x 20 mm 2to5 (G) Piping tape 1 (H) Putty 1
Drain hose (or soft PVC hose, 19/32 in. [15 ram] 2 to 5
(I) inner diameter or hard PVC pipe
VP16) (J) Refrigerant oil 1 (K) Power supply cord* 1
* Note: Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 3 ft. (t m) away from the TV antenna wire.
t"
Use the wall hole sleeve (C) to prevent indoor/out-
door connecting wire (A) from contacting metal
parts in the wall and to protect the wiring from
rodents.
i _/_[fj-Wafi_ holecover (D)
Indoor umt _ SeaJ the waft hole ]
_ [.gapwith putty(H). J
Wail hole ' FJJ// ,-_ sleeve_.ach teh pipe to|
I//tt F_ [lachment strap (E). l
Cut off the Pipeattachment extra length. _rap (E)
Attachment screw (F)
/(1)
[After the leak test, apply insulating mate- 1
j_ /rial tightly so that there is no gap. J
(9
When the piping is to be attached to a wall comprised of tin plate or metal netting, use chemically treated wooden piece 25/32 in. (20 mm) or thicker between the wall and the piping, or wrap insulation vinyl tape 7
:)
J
to 8 turns around the piping. To use existing piping, perform COOL operation for 30 minutes and pump down
before removing the old air conditioner. Remake flare according to the dimension
for new refrigerant.
Basicafly open 4 in. (100 ram) or more
without any obstruction
in front and on both
sides of the unit.
(100 mm)
or more
;I:[L.
2-3/8 x 13/16 slot
31-1/2
Is--- 19-11/16
/- 4>
,/ Air outlet
Unit: inch
Unit: mm
8oo
Open two sides of left, right, or rear side.
11-_0,. 500 1
2-10 x21 slot/// Air outlet
aUnitsshould be installed by licensed
ccording to local code requirements. J
contractor 1
Drain piping for outdoor unit Install the unit horizontally. Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet by drain
water or damaged by frozen drain water.
2-1. ATTACHING THE INSTALLATION PLATE
Find a stud in the wall to attach installation plate (1) horizontally on the wall with screws (2).
To prevent installation plate (1) from vibrating, be sure to install the attachment screws in
the holes indicated in the illustration. For added support, additional screws may also be installed in other holes.
When the indoor unit is to be attached to a concrete wall using recessed bolts, secure installation plate (1) using 7/16 in. x 13/16 in . 7/16 in. x 1 in. (11 mm x 20 mm . 11 mm x 26 ram) oval hole (17-3/4 in. [450 ram] pitch).
If the recessed bolt is too long, change itfor a shorter one (field-supplied).
// 5-5/8 in. (60 mm) or more :_ L"2-3/8 in. (142.5 mm) or more for left
and left back piping (using spacer)
Wall
4
2-2. DRILLING
t) Determine where the holes will be located on the wall.
2) Drill a _ 2-9/16 in. (65 mm) hole. The outdoor side should be 6/32 to 9/32 in. (5 to 7 mm) lower than the indoor side.
3) Insert wall hole sleeve (C).
2-3. CONNECTING WIRES FOR INDOOR UNIT
Note: When the indoor unit is powered from the outdoor unit, depending on local code, a discon-
nect switch needs to be installed to a power supply circuit.
t) Remove the panel assembly. (Refer to 5-1 .)
2) Place the upper part of the indoor unit on the installation plate.
3) Remove corner box and conduit cover.
4) Attach conduit pipe (for rear piping) / elbow joint (for right, left, or downward piping) to conduit cover with lock nut. The thread of the installed conduit pipe / elbow joint appear-
ing inside should be less than 3/8 in. (10 mm). (Fig. 1) Elbow joint should appear less than 1-3/16 in. (30 mm) outside. (Fig. 2)
5) Process the end of ground wire (Fig. 3). Connect it to the ground terminal of electrical parts box.
6) Process the end of indoor/outdoor unit connecting wire (A) (Fig. 3). Attach it to the terminal block. Be careful not to make mis-wiring. Attach the wire to the terminal block securely so that its core cannot be seen, and no external force affects the connecting
section of the terminal block.
7) Firmly tighten the terminal screws. After tightening, verify that the wires are tightly fas- tened.
8) Secure indoor/outdoor unit connecting wire (A) and the ground wire with conduit cover. Never fail to hook the claw of the conduit cover to the electrical box. Attach the conduit
cover securely. (Fig. 4)
9) According to the piping direction, remove the shaded part of the left side of box (Fig. 5) or corner box (Fig.6). Reinstall corner box and front panel.
f
Attachment screw (2)
!l
Fixing j_ screw
Conduit pipe
(forrear piping)
plumb
line with the mark V.
(65 mm) 6/32-9/32 in.
O 2-9/16 in.
Plumb
Wall
Outdoor side
1
/
Lock nut Conduit
cover
or _ Elbow joint
(for right, left, or downward piping)
(5-7 mm)
Indoor terminal
* Same for left hole.
block
Centerof o 2-9/16 in. (65 mm) hole
Remark: INDOOR UNIT * A disconnect switch is rTerminal block ,_ Grouding
required, terminal** Checkthe local code. i r_S2T_ _ '
** use a ring tongue termi- t
nalin order to connect a ground wire to terminal /_ Disconnect
2081230V AC 1phase, 60 Hz \
OUTDOOR UNIT
switch*
2061230VAC.14 2i7 t1phase 2wires. i i [
Ground
Grouding terminal**
Connect wires to the appropriate terminals
For future servicing, leave some slack in the connecting wires.
Conduit cover
Fig. 1
19/32 in.
(25 mm)
1 in. __L_ (15 mm)
f
Lead z wire
Make ground wire a little longer than
others. (More than 1-9/16 in. [40 mm])
Fig. 3
............
!_ox
(for right, left, or downward piping)
/ Cornerbox
in.
Fig. 2
Fig. 4
Remove panel for Removepanel for pipingon left side of piping on bottomleft unit side of unit
Fig. 5
Remove panel for piping on right side of piping on bottom side unit
of unit Fig. 6
2-4. PiPE FORMING AND DRAIN PiPiNG
2-4-1. PiPE FORMING
Place the drain hose below the refrigerant piping.
Make sure that the drain hose is not crowded or bent.
Do not pull the hose when applying the tape.
When the drain hose passes the room, be sure to wrap it with insulation material (field-supplied).
Note: Make sure not to damage the cover of refrigerant pipe when attaching it back on with
Left or left-rear piping Note:
Be sure to reattach the drain hose and the drain cap if the piping is being installed on left or bottom left of unit, otherwise, water could drip down from the drain hose.
1)Place the refrigerant piping and the drain hose together, then firmly apply felt tape (7) from the end.
Felt tape (7) overlap width should be t/3 the tape width. Use a bandage stopper at the end of felt tape (7).
2) Pull out the drain cap at the back right of the indoor unit. (Fig. 1)
Hold the convex section at the end and pull the drain cap.
3) Pull out the drain hose at the back left of the indoor unit. (Fig. 2)
Hold the claw marked by the arrows and pull out the drain hose forward.
4) Put the drain cap into the section to which the drain hose is to be attached at the rear of the indoor unit. (Fig. 3)
Insert a screwdriver into the hole on the cap and insert the cap fully into the drain
pan.
5) Insert the drain hose fully into the drain pan at the back right of the indoor unit. (Fig. 4)
Check if the hose is hooked securely to the projection of its inserting part at the
drain pan.
6) Insert the drain hose into wall hole sleeve (C), and attach the upper part of indoor unit onto the installation plate (1). Then, shift the indoor unit completely to the left to
make placing the piping in the back of the unit easier.
7) Cut out a piece of cardboard from the shipping box, roll it up, hook it onto the back rib, and use it as a spacer to lift the indoor unit. (Fig. 5)
8) Connect the refrigerant piping with the extension pipe (B).
9) Attach the lower part of the indoor unit into the installation plate (1).
/_ f_',._)lndoor/outd ...... it
........ _._ain cap
Liquidpipe
/__X'_Gaspipe
connectingwire (A)
Felttape (7) Piping tape (G)
Fig. 1 Fig. 2
_i _! _ Drain hose
Fig. 3
Fig. 5
Fig. 4
Rear or bottom piping
1) Place the refrigerant piping and the drain hose together, then firmly apply piping tape (G) from the end.
2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the up- per part of the indoor unit on the installation plate (1).
3) Check if the indoor unit is attached securely on the installation plate (1) by moving the unit to left and right.
4) Attach the lower part of the indoor unit into the installation plate (1).
Right piping Note:
Before performing the following, make sure that wiring is completed, and the conduit cover is installed. (Refer to 2-3.)
1) Place the refrigerant piping and the drain hose together, shift them to left side of the unit, and then firmly apply piping tape (G) from the end.
2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the up- per part of the indoor unit on the installation plate (1).
3) Check if the indoor unit is attached securely on the installation plate (1) by moving the unit to left and right.
4) Attach the lower part of the indoor unit into the installation plate (1).
2-4-2. DRAIN PIPING
If the extension drain hose has to pass through a room, be sure to wrap it with insu- lation (field-supplied).
The drain hose should point downward for easy drain. (Fig. 1)
If the drain hose provided with the indoor unit is too short, connect it with a field-
supplied drain hose (I). (Fig. 2)
When connecting the drain hose to a hard vinyl chloride pipe, be sure to insert it se- curely into the pipe. (Fig. 3)
Remove panel for pipingon bottom side of unit
Removepanel I1 II II I II l/Ill ----_
for piping on !/II IEI II
rightsideof II | _,_.1F'/",-,_k_. unit _t-k_lr_l__
To the left
/
/
O
Downward slope
Fig. 1
- hose ...... / HI/A_,_ Hard vinyl chloride pipe
Fly_ Soft(119/32in.5mm)h°seI.D. Different°rmore _c_ril [i(.................!.................
oran HM oranhose/
Fig. 2 Fig. 3 J
z7-_/1 b m.
(7gem>/ HHHID1-3/16,n
diameter joint _1 _
_0mm
[ Do not make drain _ as shown below, i
At least
o not raise
Water leakage
Water
leakage Waving
3-1. CONNECTING WIRES FOR OUTDOOR UNIT
t) Remove the service panel.
2) Remove the conduit cover.
3) Attach the conduit connector to conduit plate with lock nut then secure it against unit with screws.
4) Connect ground wires of indoor/outdoor unit connecting wire (A) and power supply cord (K) to the TB support.
5) Loosen the terminal screw, and attach indoor/outdoor unit connecting wire (A) from the indoor unit correctly on the terminal block. Attach the wire to the terminal block securely so that its core cannot be seen, and no external force affects the connecting section of the terminal
block.
6) Firmly tighten the terminal screws. After tightening, verify that the wires are tightly fastened.
7) Connect power supply cord (K).
8) Install the conduit cover.
9) Install the service panel securely.
Serv_e panel
/V__._] ,H--f--_ ...... tingwire (A)
_ Conduit cove
TBsu port ......pp,ycord .
(15 mm)
liiil, nln_ll 19/32 in.
Lead
Terminal block (More than 2_3/8 in. [60 mm])
i,, Make earth wire a little longer than others. |
_ _ the connecting wires.
\ \ / / - ___Jndoor/outdoorunit
I I _ Conduitcover
For future servicing, leave some slack in
Powersupply cord (K)
i
J
3-2. FLARE CONNECTION
t) Cut the copper pipe as straight as possible with a pipe cutter. (Fig. 1, 2)
2) Remove all burrs from the cut section of the pipe, ensuring that precautions are taken to avoid getting metal shavings into the piping. (Fig. 3)
3) Remove flare nuts attached to indoor and outdoor units, then put them on pipe.
4) Flaring work (Fig. 4, 5). Firmly hold copper pipe in the dimension shown in the table. Select A mm from the table according to the tool you use.
5) Check
Compare the flared work with Fig. 6.
If flare is defective, cut off the section and repeat procedure.
Pipe diameter inch Clutch Clutch Wing nut ft.l b
inch (mm) (mm) type tool type tool type tool N-m (kgf.cm)
1/4 (6.35) (17) 0.08
3/8 (9.52) (22) 0 to 0.02 0.06
1/2 (12.7) (26) 1.5) 0.08 to 49.0to 56.4
5/8 (15.88) (29) 2.5) 73.5 to 78.4
Nut
for R410A for R22 for R22
I/4 0.06 to 13.7to 17.7
3/8 0.04 to 2.0) 34.3 to 41.2
I/2 (0 to 0.5) (1.0 to
5/8 (2.0 to
A inch (mm) Tightening torque
10 to 13
(140to 180)
(1.5 to
25 to 30
(350to 420)
36to42
0.10
(500to 575)
54to58
(750to 800)
_ Copper
prpe
Fig. 1
Flaringtool ,_.._.._
lutch type Wing nuttype
Smooth all around Inside isshin-
/_ scratches.
Even Length
all around _ Fig. 6
Fig. 4
ingwithout any
Good Nogood
90° I
Tilted Uneven Burred
Fig. 2
Copper pipe
are reamer
Pipe cutter
Fig. 3
A
__4
Die _ Copperpipe
Flare nut Fig. 5
3=3. PIPE CONNECTION
Fasten flare nut with a torque wrench as specified in the table (refer to 3-2.).
When fastened too tight, flare nut may eventually break and cause refrigerant leakage. indoor unit connection
Connect both liquid and gas pipings to indoor unit.
Apply a thin coat of refrigerant oil (J) on the seat surface of pipe.
To connect, first align the center, then tighten the first 3 to 4 turns of flare nut.
Use tightening torque table above as a guideline for indoor unit side joints, and tighten
using two wrenches. Excessive tightening damages the flare section.
Outdoor unit connection Connect pipes to stop valve pipe joint of the outdoor unit following the same procedure
detailed in Indoor unit connection.
For tightening, use a torque wrench or spanner.
3-4. INSULATION AND TAPING
t) Cover piping joints with pipe cover.
2) For outdoor unit side, insulate the piping, including valves.
3) Apply piping tape (G) starting from the connection on the outdoor unit.
When piping has to be installed through a ceiling, closet or where the temperature and humidity are high, use additional field-supplied insulation to prevent condensa-
tion.
4-1. PURGING PROCEDURES AND LEAK TEST
t) Remove service port cap of stop valve on the side of the outdoor unit gas pipe.
2) Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit.
*4 to 5 turns Stop valve cap (-30 in.Hg (for R410A)
*Close 29.4 N,m, 200 Stop valve (for R410A)
*Open ,_ _n to 300 kgf, em) for LIQUID Gaug ..... ifold valve
_'-_" li,._ (for R41OA)
_ _--._ Handle
Hexagonal wrench
Service port cap (Torque 13.7 to
17.7 N-m, Adapter for pre- 180 kgf-cm) venting the back
(Torque 19.6 to Pressure gauge
-Precautions when usin the control valve i When attachinq the control valve
Close Charge hose
Body
3) Run the vacuum pump 15 minutes or more.
4) Check the vacuum with the gauge manifold valve, then close it and shut off the vacuum pump.
5) Leave as it is for one or two minutes. Make sure pointer gauge manifold valve remains in the same position. Confirm that pressure gauge shows 0.101 MPa [Gauge] ( 30 in.Hg [-760 mmHg]).
6) Quickly remove gauge manifold valve from service port of stop valve.
7) After refrigerant pipes are connected and evacuated, fully open all stop valves on both sides of gas pipe and liquid pipe. Operating the unit without fully opening the valves lowers the performance and causes problems.
8) Refer to t-3. SPECIFICATIONS, and charge the prescribed amount of refrigerant if needed. Be sure to charge slowly with liquid refrigerant. Otherwise, composition of the refrigerant in the system may be changed and affect performance of the air conditioner.
9) Tighten cap of service port.
10) Conduct a leak test
-0.101 MPa Compound pressure gauge
Low Handle High
Stop valve for Charge hose
flow
to the service port valve core may deform or loosen if excess pressure
(for R41OA)
Vacuum pump (or the vacuum pump with the function to prevent the back flow)
is applied. This may cause qas leak.
When attaching the control valve to the service port, make sure that the valve core is in closed position, and then tighten partA. Do not tighten partA or turn the body when valve core is in open position.
1
4=2.TEST RUN
1) Insert power supply plug into the power outlet and/or turn on the breaker.
2) Press the E.O. SW once. Test run will be performed for --_
30 minutes. If the power lamp blinks every 0.5 seconds, inspect the indoor/outdoor unit connecting wire (A). After
the test run, emergency COOL mode (75°F [24°C] COOL) will start.
3) To stop operation, press the E.O. SW several times until ency all LED lamps turn off. Refer to operating instructions for _ operationswitch details. (E.O.SW)
Checking the remote (infrared) signal reception Press the ON/OFF button on the remote controller and listen for an audible indicator from
the indoor unit. Press the ON/OFF button again to turn the air conditioner off.
Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner.
4-3. AUTO RESTART FUNCTION
This product is equipped with an auto restart function. When the power supply is cut off during operation, such as during blackouts, the function automatically starts operation in the previous setting once the power supply is resumed. (Refer to the operating instructions
for details.)
Caution:
After test run or remote signal reception check, turn off the unit with the E.O. SW or the remote controller before turning off the power supply. If this procedure is not per- formed, the unit will automatically begin operation when power supply is resumed.
To the user
After installing the unit, explain to the user about auto restart function.
If auto restart function is unnecessary, it can be deactivated. Consult the service rep-
resentative to deactivate the function. Refer to the service manual for details.
4-4. REMOTE CONTROLLER SETTING
J
Set the slide switch of the remote controller according to where the indoor unit is installed in the area. If the switch is not set correctly, the air conditioner may not function properly.
Location of unit in area: Left: Distance to objects (wall, cabinet, etc.) is less (Left)(Center)(Right)
than 19-11/16 in. (50 cm) to the left
Center: Distance to objects (wall, cabinet, etc.) is
more than 19-11/16 in. (50 cm) to the left and right
Right: Distance to objects (wall, cabinet, etc.) is less
than 19-11/16 in. (50 cm) to the right
t) Remove the front lid.
2) Set the slide switch according to the installed position of the indoor unit.
3) Insert two (AAA) batteries.
4) Reattach the front lid.
5) Press the RESET button gently using a thin instrument.
Installation posi- Left Center Right
tion
L.C.R L.C.R L.C.R
RESET 5Iq 2_/ button _._ ('[_]_')
SLIDESWITCH
S,ideswitch
Remote controller
display r-_ _ _"q
4=5. EXPLANATION TO THE USER
Using the OPERATING INSTRUCTIONS, explain to the user how to use the air condition-
er (the remote controller, removing the air filters, placing or removing the remote controller from the remote controller holder, cleaning methods, precautions for operation, etc.)
Recommend that the user read the OPERATING INSTRUCTIONS carefully.
5=1. REMOVING AND INSTALLING THE PANEL
ASSEMBLY
Removal procedure t) Remove the two screws that attach the panel assembly.
2) Remove the panel assembly. Be sure to remove its bottom end first.
Installation procedure t) Install the panel assembly following the removal procedure in reverse.
2) Be sure to press the positions as indicated by the arrows in order to attach the assembly completely to the unit.
5-2. REMOVING THE INDOOR UNIT
Remove the bottom of the indoor unit from the installation plate. When releasing the corner part, release both left and right bottom corner part of indoor unit and pull it downward and forward as shown in the figure on the right.
If the above method cannot be used Remove the front panel. Then, insert hexagonal wrenches into the square holes on
the left and right sides of the unit and push them up as shown in the following figure. The bottom of the indoor unit lowers and releases the hooks.
5-3. PUMPING DOWN
When relocating or disposing of the air conditioner, pump down the system following the procedure below so that refrigerant is not released into the atmosphere.
1) Connect the gauge manifold valve to the service port of the stop valve on the gas pipe side of the outdoor unit.
2) Fully close the stop valve on the liquid pipe side of the outdoor unit.
3) Close the stop valve on the gas pipe side of the outdoor unit almost completely so that it can be easily closed fully when the pressure gauge shows 0 MPa [Gauge]
(0 Ibf/in. 2[0 kgf/cm2]).
4) Start the emergency COOL operation. To start the emergency operation in COOL mode, disconnect the power supply
plug and/or turn off the breaker. After 15 seconds, connect the power supply plug and/or turn on the breaker, and then press the E.O. SW once. (The emergency COOL operation can be performed continuously for up to 30 minutes.)
5) Fully close the stop valve on the gas pipe side of the outdoor unit when the pressure gauge shows 0.05 to 0 MPa [Gauge] (approx. 7.25 to 0 Ibf/in 2 [0.5 to 0 kgf/cm_]).
6) Stop the emergency COOL operation. Press the E.O. SW twice to stop the operation.
When pumping down the refrigerant, stop the compressor before discon-
necting the refrigerant pipes. The compressor may burst if air etc. get into it.
Square hobe
Lower 7//, )
MITSUBISNI ELECTRIC CORPORATION
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN