Mitsubishi Electric MS-07NV II-E1 WH, MS-09NV II-E1 WH, MS-12NV II-E1 WH, MS-07NV-E2, MS-09NV-E2 Service Manual

...
Page 1
SERVICE MANUAL
SPLIT-TYPE AIR CONDITIONERS
CONTENTS
1. TECHNICAL CHANGES ····································2
2. OUTLINES AND DIMENSIONS·························2
3. PARTS LIST ·······················································3
Wireless type Models
MS-07NV
22
-
(WH)
· MU-07NV -
MS-09NV
22
-
(WH)
· MU-09NV -
MS-12NV
22
-
(WH)
· MU-12NV -
E2E1
E2E1
E2E1
No. OB214
MS-09NV22-
E1
NOTE:This Service Manual covers only change points. (MS-07/09/12NV- MS-07/09/12NV2-)
Please refer to the Service Manual OB206 for unchanged contents. Please refer to the Service Manual OB206 for MU-07/09/12NV- .
E2
E1E2
Page 2
2
1
TECHNICAL CHANGES
MS-07NV - ➔MS-07NV22-
1. Indoor unit design has changed.
2. Refrigerant filling capacity(R-22) has changed. (0.65kg 0.80kg)
MS-09NV - MS-09NV22-
1. Indoor unit design has changed.
2. Refrigerant filling capacity(R-22) has changed. (0.9kg 0.85kg)
MS-12NV - MS-12NV22-
1. Indoor unit design has changed.
E1E2
E1E2
E1E2
OUTLINES AND DIMENSIONS
2
MS-07NV22- MS-09NV22- MS-12NV22-
E1E1E1
INDOOR UNIT
314.5323
2.5
186
191
223
266.5
46
41
225
84.5 9
133.5
84.5
225
93
183
13062560
275
815
17.5
783
72
7 or more
100
90
5
160
56
Liquid line [6.35-0.5m Gas line [9.52-0.43m Insulation [35 O.D [19 I.D
Wireless remote controller
Power supply cord Lead to right 1.0m Lead to left 0.3m
Installation plate
Indoor unit
Wall hole [65
Installation plate
Drain hose [16 Insulation [28
Air out
{
Air in
Unit : mm
Page 3
3
PARTS LIST3
INDOOR UNIT STRUCTURAL PARTS MS-07NV22- (WH) MS-09NV22- (WH) MS-12NV22- (WH)
E1
E1
E1
E02 343 000 E02 344 000 E02 345 000 E02 339 010 E02 164 100 E02 166 234 E02 151 970 E02 166 067
1
2 3 4 5 6
FRONT PANEL(WH) FRONT PANEL(WH) FRONT PANEL(WH) GRILLE(WH) AIR FILTER BOX(WH) INSTALLATION PLATE SCREW CAP(WH)
Symbol
in Wiring
Diagram
Q'ty/unit
1
1 2 1 1 2
1
1 2 1 1 2
1 1 2 1 1 2
2PCS/SET
RemarksPart No.
NO.
Part Name
E1
MS-12NV2-
(WH)
MS-07NV2-
E1
E1
MS-09NV2-
(WH)
(WH)
Optional part
5
4
1
6
2
3
E02 151 620 E02 155 620 E02 151 666 E02 155 666 E02 151 667
1
2
3
INDOOR HEAT EXCHANGER INDOOR HEAT EXCHANGER UNION(GAS) UNION(GAS) UNION(LIQUID)
Symbol
in Wiring
Diagram
Q'ty/unit
1
1
1
1
1 1
RemarksPart No.
NO.
Part Name
MS-07/09NV2-
(WH)
E1
MS-12NV2­ (WH)
E1
{9.52 {12.7 {6.35
1
2
3
INDOOR UNIT HEAT EXCHANGER MS-07NV22- (WH) MS-09NV22- (WH) MS-12NV22- (WH)
E1
E1
E1
wA set of FRONT PANELand GRILLE of NV2series is compatible with that of NV series.
Page 4
INDOOR UNIT ELECTRICAL PARTS MS-07NV22- (WH) MS-09NV22- (WH) MS-12NV22- (WH)
E1
E1
E1
E02 199 235 E02 166 040 E02 141 702 E02 151 303 E02 151 300 E02 151 505 E02 151 302 E02 151 509 E02 151 308 E02 151 307 E02 197 375 E02 202 452 E02 204 452 E02 152 395 E02 127 382 E02 085 385 E02 001 504 E02 151 468 E02 199 520
1 2 3 4 5 6 7 8
9 10 11
12
13 14 15 16 17 18
NOZZLE(WH) VANE(WH) DRAIN HOSE VANE MOTOR INDOOR FAN MOTOR RUBBER MOUNT LINE FLOW FAN BEARING MOUNT ROOM TEMPERATURE THERMISTOR INDOOR COIL THERMISTOR TERMINAL BLOCK ELECTRONIC CONTROL P.C.BOARD ELECTRONIC CONTROL P.C.BOARD POWER SUPPLY CORD FUSE VARISTOR SLEEVE BEARING RECEIVER FAN GUARD
Symbol
in Wiring
Diagram
Q'ty/unit
RC4V19 ­2PCS/SET
AUTO RESTART AUTO RESTART
3.15A
RemarksPart No.
NO.
Part Name
MV
MF
RT11 RT12
TB
F11
NR11
MS-07NV2-
E1 E1 E1
MS-09NV2- MS-12NV2-
1 1 1 1 1 2 1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 2 1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 2 1 1 1 1 1
1 1 1 1 1 1 1
(WH)
(WH)
(WH)
Part number that are circled is not shown in the illustration.
7
16
8
3
2
9
11
6
5
13
1
4
10
12
HEAD OFFICE MITSUBISHI DENKI BLDG.MARUNOUCHI TOKYO100 TELEX J24532 CABLE MELCO TOKYO
CC
Copyright 1998 MITSUBISHI ELECTRIC ENGINIEERING CO.,LTD Issued in Jan. 1998. No.OB214 628 Printed in Japan
New publication, effective Jan. 1998 Specifications subject to change without notice.
Loading...