Mitsubishi Electric MJ-E26SX-A1 Instruction Manual

Before using the
unit
Operating
Troubleshooting
MITSUBISHI
MODEL
MJ-E26SX-A1
Features
Powerful Dehumidifying
Easy Dehumidifying. Laundry
Wide-angle Swing Louvre. Low
Air Outlet
Negative Ions
Table of Contents page
¡Getting the most out of your
dehumidifier...........................................2
¡Precautions............................................3
¡Warning..................................................5
¡Names and functions of parts .............6
¡Things to be aware of...........................8
¡Before using your dehumidifier...........9
¡Turning the Unit ON and OFF ..............9
Turning the unit on/off
¡Switching operating modes ...............10
Easy Dehumidifying - Laundry - High - Low ­Mildew Guard - Low Temp - Auto
¡Swing louvre function ........................12
How to read the swing monitor
¡Information display .............................13
High humidity warning - Defrosting indicator ­Low temperature indicator - Negative ion lamp
- Tank full lamp
¡Using the Timer ...................................14
OFF Timer operation/ON Timer operation
¡Using the Child lock ...........................16
¡Carrying the unit .................................16
¡Removing water from the tank ..........17
¡Continuous drainage ..........................18
¡Maintenance ........................................19
¡
Replacing the Air purifying filter
.............21
¡Storage.................................................21
¡Troubleshooting ..................................22
¡Specifications......................................24
¡In order to ensure correct usage, please read
this instruction manual carefully and retain it for future reference.
¡Before accepting the Warranty at the time of
purchase, please make sure that the date of purchase, place of purchase and other items are correctly filled in the form.
Printed on recycled paper.
Protect our environment and enrich our lives by saving energy
2
Getting the most out of your dehumidifier
Combine operating mode and swing louvre function to get optimum results.
Drying laundry indoors
¡Use the dehumidifier in
a small, enclosed room.
¡Direct the louvers at the
laundry.
¡Space laundry to
improve airflow
¡Maintain room
temperature above 16°C with an air conditioner
• In low temperatures, drying takes about twice as long as normal. (Drying times will vary depending on the nature of the laundry and the room temperature.)
• The airflow is strongest to the top right of the unit.
Installing your dehumidifier
Make sure to leave some space around the unit.
Operating noise
Place the unit on top of a mat. This reduces vibration and noise. It also prevents leaving depressions on carpets.
Drain the water tank before use Refrain from opening doors/windows during operation
Objective
Recommended mode and louvre setting
Page
Drying laundry
When you don’t want to hang the clothes outside or it is raining...
¡ Selection
Laundry
¡ Swing Louvre
Up
¡Selection
¡Mode
¡Swing Louvre
page10
page10&11
page
12
¡ Selection
Easy Dehumidifying
¡ Mode
Auto
¡ Mode
Low Temp
¡ Mode
Mildew guard
¡ Mode
Low
¡ Swing Louvre
Rear
When you don’t know what humidity level to set the unit to...
When you want to set the humidity level...
When condensation occurs indoors...
To prevent mildew...
To keep the inside of closets and shoeboxes dry...
Lowering room humidity
Preventing mould/con densation
direct the air flow
At least 50 cm
At least 20 cm
At least 20 cm
At least 20 cm
At least
20 cm
Operating tips
¡ Mode
High
¡ Swing Louvre
Low Air Outlet
For drying the bed or carpet
direct the air flow
3
Before using the
unit
Precautions
Do not start/stop the unit by plugging/unplugging the power cord.
This may result in fire and/or electric shock.
Do not use extension cords or multiple head adapters.
This may result in fire, electric shock or malfunctions.
Do not damage or modify the power cord or plug.
Do not modify, bundle, twist, bend or heat the power cord. Do not place under objects or use with the end close to the plug bent.
The cord may be damaged resulting in fire or electric shock. (Keep pets from biting the cord.)
Do not put your fingers or any long object, into the air intake/outlet. Do not touch the swing louvre.
The internal fan rotates at high speeds, and such actions may result in injury or malfunctions.
Do not attempt to repair, disassemble, or modify the unit.
This may result in fire and/or electric shock.
Refer servicing to your dealer or Mitsubishi Electric Service Centre.
Do not put the unit near heat-generating devices (such as stoves, fan heaters, etc.).
The plastic parts may melt causing fire.
Wipe dust off the power plug and insert the plug firmly.
If the plug is not fully inserted into the socket, dust may gather on the connectors which may cause fire
and/or electric shock.
Use 220-240V AC power sockets that can withstand more than 15A current.
Connecting to power sockets other than 220­240V AC may result in fire
and/or electric shock.
Remove water that has collected in the tank.
Accidentally drinking the water or using it for other purposes may cause
illness and/or unforeseen accidents.
Should abnormal symptoms occur (a burning smell, etc.), switch off the unit and unplug it from the socket.
Continuing to operate the unit may result in fire, electric shock, or malfunctions. Contact your dealer or Mitsubishi Electric Service Centre for consultation.
The following diagrams indicate circumstances where danger can result from mishandling the unit.
Meanings of the graphic symbols used in this manual and on the unit are explained below.
WARNING
Mishandling may result in fatal or serious injuries.
CAUTION
Mishandling may result in injuries or damage to your home or property, etc.
Always follow the instructions
WARNING
Forbidden
Keep away from fire
Do not disassemble
Do not subject to water
Petrol
Thinner
Benzine
4
Do not cover the side air intakes or the air outlet with cloth, curtain, etc.
This results in poor ventilation and may cause heat generation/fire.
Do not stand, sit, or lean against the unit. Do not pull the unit by the air outlet.
As the unit is on wheels, it may move, tip over, or fall causing
personal injury.
Do not put vases or any other objects filled with water on the unit.
Water may leak into the unit adversely affecting electric insulation and cause electric shock and/or
fire by short-circuiting.
Do not use the unit where it may be exposed to direct sunlight or other weather conditions. (This unit is for indoor use only.)
This may cause overheating, electric shock and/or fire caused by an electric leak.
Do not use the unit in narrow, enclosed places such as inside closets, between pieces of furniture, etc.
This results in poor ventilation and may cause heat generation
and/or fire.
Do not use combustion appliances in the path of the air outlet.
This may cause incomplete combustion in the appliance.
Do not use the unit in places where chemicals are used (such as hospitals, factories, laboratories or beauty salons).
Chemicals and solvents evaporated in the air may harm the unit and cause water in the tank to leak, resulting in damage to
property.
Do not use the unit for special purposes, such as preservation of food, art or scientific works.
This may negatively affect the quality of the items stored.
Do not drain water continuously if there is a possibility that temperature around the hose could drop to freezing point.
Water inside the hose may freeze and prevent the water in the tank from flowing out. The water may leak from the unit and
damage surrounding objects.
Do not use the unit in places that may be subject to oil or flammable gas leakage.
Such a leak around the unit may cause combustion and fire.
Do not remove the Styrofoam from the floating element.
The floating element will not be able to detect a full tank resulting in water leakage, which may damage
surrounding objects or cause electric shock and/or an electric leak.
Do not wash the unit with water. Do not use the unit where it is likely to come in contact with water.
Exposure to water may result in fire or electric shock caused by an electric leak .
CAUTION
Precautions
5
Before using the
unit
Warning
Keep the unit always in an upright position.
Inclining the unit may cause water
in the tank to leak into the unit, resulting in malfunction. Should you incline the unit accidentally, contact the place of purchase for advice.
Do not carry the unit horizontally.
This may result in malfunctions.
Do not point air-flow from the unit directly at the body .
If air-flow is directed at the body for long periods, it may harm one’s
physical condition and lead to dehydration.
Install the unit in a location where the floor is flat and stable.
If the unit falls over, the water collected in the water tank may leak damaging surrounding objects and in turn result in fire or electric
shock caused by an electrical leak.
Grasp the plug and remove from the power socket.
When removing the plug from the power socket, do not pull on it diagonally or by the cord as this may cause the projections/wiring to be damaged resulting in a short
circuit, electric shock or fire.
Before moving the unit always switch it off, unplug it and remove water from the water tank.
Moving the unit with water in its tank may cause the water to leak and damage the surrounding objects and in turn result in electric
shock and/or an electric leak.
After emptying the tank, transport the unit by grasping the handle firmly.
Losing your footing while carrying the unit may cause personal injury or damage to the floor.
When using the continuous drainage outlet, make sure to position the hose so that the water drains without obstruction.
The water in the tank may leak and damage surrounding objects.
When draining water continuously or left unattended for long periods, inspect the unit every two weeks.
Do not allow debris to clog the filter/hose as this may cause over-heating/leakage.
Use the unit with caution in rooms where the walls, furniture and art work is vulnerable to dry air, as it may cause cracks and warping.
Switch the unit off and unplug from the power source when cleaning it.
When the unit is on, the internal fan rotates at high speeds and may
cause injury.
Unplug the unit from the power source when not using the unit for an extended period of time.
Otherwise it may cause fire and/or electric shock caused by an electric leak.
CAUTION
The appliance is not inteded for use by young children or infirm persons without supprvision;Young children should be suppervised to ensure that they do not play with the appliance
6
Names and Functions of Parts
Front
Control Panel
Back
Cord Tie Remove during operation
Storage Hook
Power plug
Air Purifying Filter
Preset at time of purchase
Air Filter (Rear Air Intake)
Do not block
Handle
Louvre
Sensor
Do not cover
Main Air Outlet
Tank Lid
Control Panel
Tank Guard
Float
Level Window
The water tank may contain water residue at time of purchase. This is from final product testing at the factory and is not due to a defect.
12
16
¡Lamp
Current mode lights
¡Selection button
Switches modes
7 operating mo
SELECTION
¡ EASY
DEHUMIDIFYING
¡ LAUNDRY
10
9•17
9•17
17
16
18
Low Air Outlet
Water Tank
9•17
19
19
Wheel (4)
Continuous Drainage Outlet
7
Before using the
unit
LCD Panel
¡Mode button
For switching from one operating mode to another
¡Child lock
To set the child lock, press the mode button for three seconds.
¡
Humidity Selection
This is used to set the target humidity.
¡Swing louvre
button
Sets swing louvre direction or locks it into position
¡Power lamp
Lights when unit is ON.
¡Power button
Use this to switch the unit OFF and ON.
des
¡ HIGH ¡ LOW
¡Negative ion
lamp
Lights when negative ion function is ON.
¡Information display
Indicates room and unit condition
.....
Flashes when the power is OFF and the humidity rises
.....
Lights when the defrosting function is operating.
.....
Lights when the power is ON and the room temperature drops below 15°C.
All indicators on the LCD panel shown below.
¡Timer ON/OFF
Sets timer
¡Tank full lamp
This lights up to warn that the water tank is full.
¡Mode Indicator
Indicates the current operating mode.
¡Humidity Indicator
This indicates the approximate humidity.
indicates the current humidity
indicates the humidity setting in AUTO mode
The current humidity is displayed in a range from 30 to 80%.
¡Swing monitor
Indicates the direction of the swing louvre.
¡Timer display
Displays the time set for the ON/OFF timer.
16
12129
8~13
13
13
14~15
14~15
10~11
10~11
10~11
¡ MILDEW GUARD ¡ LOW TEMP ¡ AUTO
MODE
Room temperature may rise 2-4°C during operation
The humidity reading on the unit may differ from a hygrometer in the same room
Low temperature/humidity decreases dehumidifying effects
8
Things to be aware of
How does the dehumidifier work?
If you pour cold water into a cup, the air around it becomes cold, causing water droplets to form on the surface of the cup. The dehumidifier takes advantage of this phenomenon to remove moisture from the air.
1 The unit draws air from the room, cools it with
its cooling coil, causing the moisture to transform into water droplets.
2 The water droplets fall into the water tank. 3 The dehumidified air is reheated by the
heating coil, and then discharged. The humidity of the room is thus reduced by repeating steps 1, 2, and 3.
How is mildew growth suppressed?
Mildew is unable to produce new spores if dried as mycelia. The Mildew Guard feature applies this principle. (However, the spores themselves are resilient to dry conditions.)
Identification of Aspergillus and Penicillium
<Research paper by Dr. K. Abe of the
Environmental Biology Research Center>
What are negative ions?
Negative ions are particles in the air that possess a negative charge. When there are a lot of negative ions in the air, it is similar to the environment encountered in a forest and is said to provide relaxation.
Re-heating coil
Cooling coil
Moist air
Compressor
Dried (warm) air
Water tank
The dehumidifier does not have a cooler function. Due to heat produced during operation, the room temperature may rise 2-4°C. As a result, the unit may blow warm air, but this is not due to a malfunction.
Even in the same room, temperature and humidity levels may differ from place to place. If the hygrometer and the unit are in different parts of the room, the humidity levels are prone to differ. Moreover, humidity levels differ between places that have good and no airflow. Use the reading on the unit as an estimate.
In winter, the temperature is low and the air is dry, therefore making dehumidifying impossible. * If temperatures are low, but humidity is high due to
snow or rain, operating the unit in Low Temp mode will yield better results than Low mode.
Values for HIGH dehumidifying operation
¡ The dehumidification values shown on the graph
were measured at constant temperature and humidity
and do not reflect actual usage conditions.
0
2
4
6
8
10
12
14
16
18
20
22
24
26
5 10152025 30
Dehumidification capacity (L/day)
Room temperature (°C)
11
13
1
2
3
11
9
Operating
To turn ON
¡Power lamp lights ¡The mode is displayed. ¡The louvre opens automatically.
To start dehumidifying, select either one­touch operation or mode.
The unit remembers the operating mode. Even if the plug is disconnected or the power turned off, the unit restarts at the previous setting.
To turn OFF
¡Power lamp turns off. ¡The Mode Indicator
goes out.
¡The louvre closes
automatically
If the room temperature falls below 15°C,
defrosting mode is activated once every 40 minutes (for about 5 minutes) causing water to drain to the tank.
The unit can operate in a room temperature
range of 1-35°C. If the room temperature exceeds 35°C, the inside of the unit heats triggering the protection mechanism, stopping operation. When using the louvre, point UP. Never operate the dehumidifier when the room temperature is above 40°C.
If the temperature is below 1°C, the extracted water is close to freezing disabling the dehumidifier, and only the blower is operational.
Air purifying function.
While the air purifying filter is installed and the unit is running, the air purifying function operates all the time.
Before using your dehumidifier
Turning the Unit ON and OFF
Inserting the water tank correctly
Plug the power cord into the power socket
¡The current humidity level is
indicated.
If the louvre is open, it closes automatically.
Tank Lid
Check that the lid and guard are secure. Slide the tank in with both hands.
Use a 220-240V AC power socket only.
Press
The dehumidifier does not activate for 3 minutes when the unit is turned ON immediately after turning it OFF or plugging it into the power socket. (In order to protect the compressor.) When dehumidifying begins, the operational noise increases.
13
Press
Tank Guard
Information
When you want to dehumidify easily (without the hassles of setting humidity levels)
When you want to dry clothes quickly (without the hassles of calculating humidity levels and timer settings for the amount of laundry)
¡Laundry The unit operates for 12 hours and automatically swiches off.
Empty the water tank before operating the unit. The unit may stop before the clothes are dry due to a full tank.
Do not use in conjunction with OFF Timer mode. The unit may stop before the clothes are dry.The following conditions prevent clothes from drying well:
Room temperature below 15°C, large volume of laundry; laundry not spaced well; clothes of thick fabric and spacious room.
When the room temperature is below 5°C, less water evaporates from the clothes, decreasing the
amount of temperature change. Therefore the unit is unable to detect the state of the laundry and may turn off after 1 hour.
Restart the unit if it turns off before the laundry dries (except when the temperature is below 5°C).
10
Switching operating modes
You can choose between seven operating modes.
Information
Information
Pressing HUMIDITY SELECTION while in Easy Dehumidifying or LAUNDRY modes changes the
mode to AUTO.
Reading the humidity display
Easy Dehumidifying & Laundry modes
High, Low, Mildew Guard, Low Temp and Auto modes
SELECTION indicates set humidity level (Automatic mode only).
Even if Automatic mode is not selected using MODE, it can be activated by pressing HUMIDITY SELECTION.
CURRENT indicates the current humidity.
Current humidity range is between 30-80%.
Humidity levels below 30% are displayed as 30%.
Humidity levels above 80% are displayed as 80%.
Changes with every press
Changes with every press
Press
Press
¡Selected mode
lamp lights
¡Frame appears
around selected mode
Example
¡Easy Dehumidifying The unit automatically controls airflow to counter
excessive room temperature/humidity. It activates the blower at high temperatures.
50
020 3027
60
Humidity
level (%)
Room temperature (°C)
2
2
2
¡Room temperature is below 27°C - the unit automatically
sets the humidity level according to the temperature.
¡Room temperature is above 27°C - the unit lowers the
humidity level to 50%, then activates the blower. The dehumidifier is reactivated when humidity rises to 60%.
11
Operating
When you want to leave the dehumidifier on
When you want to suppress mildew growth
When you want to prevent condensation inside the room or when the temperature is low
When you want to set the humidity level
¡Low Temp The unit operates continuously automatically controlling airflow
according to room temperature. The air flow is strongest below 15°C. The use of Low Temp mode is recommended when the Low temperature indicator is lit.
When the temperature is low, condensation may still form on windows exposed to the
outside air even when Low Temp mode is operating
¡Auto The unit maintains the
humidity level by automatically controlling airflow and operating intermittently as necessary. All you have to do is set the humidity level.
¡ The unit turns off when current humidity
decreases past the set humidity level, and restarts when the level is exceeded.
¡ The unit operates for 6 minutes continuously
regardless of the humidity level immediately after turning the power on.
Frequent use of exits and room size/conditions may cause the humidity to not reach the set level.
<To view set humidity level/ To set humidity level>
¡ Pressing the button once displays
the set humidify level with the
indicator. After 3 seconds, the display returns to the current humidity display.
¡ Pressing HUMIDITY SELECTION
while is displayed sets the humidity level. Each time the button is pressed, the humidity setting changes.
¡
Mildew Guard
The unit lowers room humidity levels once a day (for approximately 2-4 hours), suppressing mildew growth.
¡ Once every 24 hours the dehumidifier runs for 2
hours if the humidity is 40%, or 4 hours if at 50%. The unit operates intermittently, automatically turning on and off according to the humidity level of the room.
¡ The unit continues operation if the humidity level
does not decrease.
Refrain from turning on ventilation fans or opening windows or doors as this lowers performance.Mildew growth may still occur due to the fungus type and conditions of the room.
E.g. Rooms that contain excessive condensation, bathrooms, and places with bad airflow (insides of closets and behind furniture).
This mode does not remove existing mildew.Do not use in conjunction with OFF Timer mode.
* The humidity level cannot be set in Low, Mildew Guard, and Low Temp modes.
Information
Information
ON
24 hours 24 hours
Dehumidifies Dehumidifies
Standby Standby
6570 505560
Press
Information
8
¡ High The dehumidifier operates
regardless of the humidity level. Airflow is strong.
¡ Low The dehumidifier operates
regardless of the humidity level. Airflow is weak.
repeats process
The level of noise emitted from
the unit varies according to the angle of the air-flow.
The louvre may stop up to a
maximum of 8 seconds to correct its position, after which it will start moving again.
Do not place your fingers or other
objects in the louvre to change the swing angle. Set the swing direction according to the procedures in the section Changing the swing direction.
12
Swing louvre function
(how to read the Swing monitor)
The louvre can be made to swing. Select from the 5 possible settings to suit the purpose.
60°
30°
¡WIDE
To cover the entire room.
¡REAR
For directing air into a closet.
¡UPWARD
For drying clothes, etc.
Swing speed is automatically controlled to send air to all corners of the room.
Swings slowly to send air further
Press
With each press
of the button
¡Starts swing
operation.
¡The swing monitor
is displayed.
The swing operation stops when the power cord is unplugged.
Viewing the Swing Monitor
This indicates the range of louvre swing. (The louvre and monitor do not move in synchronization.)
¡Stop swing operation
¡ The louvre stops in a vertical
position.
¡ The swing monitor turns off.
To change the louvre to a desired angle, wait until the louvre stops, then adjust by hand.
Information
¡Low Air Outlet
(no swing function)
Convenient for drying carpets or beds.
When using the low air outlet, do not close the louvre, as it needs to open slightly to make directional adjustments.
Depending on the angle of the louvre, some air may blow out of the low air outlet.
front
13
Operating
Information Display
Displays room and dehumidifier conditions.
LCD Panel
High humidity warning
The indicator flashes when the humidity in the room exceeds 75%. Activating the dehumidifier is recommended when the indicator is flashing.
If the High humidity warning is not used, remove the power plug from the power socket.
Lights during negative ion production.
Negative ions are produced when the air flow (dehumidifier) is on.
The lamp may remain off in modes that operate intermittently such as FULL AUTO, MILDEW GUARD and AUTO.
This function cannot be deactivated.
The unit automatically shuts down and indicates with the lamp and sound that the water tank is full. Empty the water tank.
¡Tank full lamp lights
The unit beeps continuously.
¡Air flows stops (louvre stops) ¡Monitor turns off ¡Negative ion lamp turns off
After removing the water and replacing the tank, the Tank full lamp will go off, and the unit will automatically return to operation mode.
When the Tank Full lamp is lit, no operation but ON/OFF is possible.
is displayed when the unit is melting the frost accumulated inside, and draining it to the tank. The air flow (dehumidifier) is stopped. After defrosting is complete, the unit restarts with the previous mode.
¡ appears ¡Air flow stops (louvre stops) ¡The operation noise changes
The unit performs this operation if the room temperature falls below 15°C (once every 40 minutes for five minutes at a time during peak periods).
The indicator comes on if the room temperature drops below 15°C. Activating Low Temp mode is recommended.
Defrosting indicator
Low temperature indicator
Negative ion lamp
Tank full lamp
Indicator lamp
11817
14
Using the Timer
4321
To cancel
<When you want to turn the unit off>
Press the Power button. (Power off)
¡ The OFF Timer is cancelled.
<When you want to disable the Timer OFF mode, and continue operation>
Keep pressed until the remaining time display disappears. The unit returns to Low mode.
¡ The OFF Timer is cancelled.
The OFF timer and ON timer cannot be set at
the same time.
Do not use timer OFF mode in conjunction with
Laundry or Midew guard.
Empty the water tank before operating. The unit
stops and the Tank full lamp lights if the tank becomes full during operation.
OFF timer operation
The OFF timer can be set for 1 to 9 hours. Set the timer when the power is switched on.
To set
1 Switch the power on. 2 Select operating mode.
Select desired operating mode.
3
Change the louvre swing direction.
Select the desired setting.
4 Set the operating time.
¡ When pressed once the figure [ ]
and [OFF] appear.
¡ Each subsequent press changes the
display in order from 1 to 9 hours. (Hold the button to run automatically through the numbers.)
The OFF timer is set.
The following is an example of a display indicating AUTO dehumidifying (set to 60%), swing set to WIDE and the OFF timer set for 2 hours.
¡
The time remaining until the unit switches itself off is indicated in increments of one hour with a flashing numeral.
¡
When the set time is reached, the unit switches itself off and the louvre closes automatically.
No Display (operation
is off)
Press
Press
Information
9
12
10~11
Press
15
Operating
The following is an example of a display indicating AUTO dehumidifying (set to 60%), swing set to WIDE and the ON timer set for 5 hours.
¡ The time remaining until the unit
switches itself on is indicated in increments of one hour with a flashing numeral.
¡ When the set time is reached, the
unit switches itself on.
To cancel
Press the Power button. (Power off)
¡ The timer is cancelled.
The ON timer function is not operable using a commercially-available timer plug outlet.
41, 523
To set
1 Switch the power off. 2 Set the time you wish the unit to
turn on.
¡
Press once. The Power lamp, Mode
indicator, and a [ ] on the digital
display flash. The [ON] indicator lights.
¡ Each subsequent press changes the
display in order from 1 to 9 hours.
(Hold the button to run automatically
through the numbers.)
3 Select operating mode.
Select desired operating mode.
4
Change the louvre swing direction.
Select the desired setting.
5 Confirm the operating start time.
¡ Power lamp and Time display light. The ON timer is set.
The unit informs you if you forget to press the Power button by making the Time display and Mode indicator blink and sounding an alarm for 1 minute.
ON timer operation
The ON timer can be set for 1 to 9 hours. Set the timer when the power is switched off.
No Display
(operation
is off)
Press
Press
Press
9
12
10~11
Information
16
Carrying the Unit
Raise handle to transport
The unit can be transported using the wheels on the bottom. Check that the water tank is empty and the louvre is shut before transporting.
¡ Sometimes the wheels are pointing
in an awkward direction making movement difficult. Do not forcibly move the unit as this may cause it to tip over.
Do not carry the unit on its side.
This will cause it to malfunction.
Use the wheels on a hard flat surface.Lift over doorsills and steps. Refrain from using
the wheels on thick-piled carpet, as this may damage the carpet.
Do not get the power cord caught in the
wheels, as this may damage the cord.
Using the Child Lock
To Lock
¡ The child lock indicator
The child lock is switched off when the power cord is unplugged.
When the child lock is activated the unit cannot be switched off or on. The other switches are also inoperable until the child lock has been released.
Releasing the child lock
¡ The child lock lamp goes out.
Press for 3 or more
seconds.
Press for 3 or more seconds.
If you lock the unit when the POWER is OFF.
The unit will not turn on, even if you press the POWER switch to turn it on. Only the CHILD LOCK lamp will blink. (Press the POWER button once again so that the lamp lights.)
If you lock the unit when the POWER switch is ON.
The unit will not turn off, even if you press the POWER switch to turn it off. Only the CHILD LOCK lamp will blink. (Press the POWER button once again so that the lamp lights.)
Note
17
Operating
Note
2 Remove the tank lid, and empty.
3
Reattach the tank lid and replace the water tank.
Check that the lid and guard are secure. Slide the tank in with both hands (you should hear a beep).
¡ Secure the lid and guard properly or
else the tank may become stuck.
¡ If the tank is not installed correctly,
the tank full light will come on, and the unit will not operate.
Do not remove or dismantle the floating element in the tank. If it is removed, the unit cannot detect when the tank is full, and this could result in leakage.
Tank Lid
Empty water from here
Removing Water from the Tank
The unit automatically shuts down and lights the Tank full lamp when the tank (approximately 5L) is full. Empty the tank.
1 Remove the water tank.
Grasp handle and slide out
Hold the tank this way
Float
Do not remove
13
Tank Guard
18
Continuous Drainage
If a drain is available, the unit can continuously drain excess water by attaching a commercially available hose (internal diameter 15mm). The unit can be operated for extensive periods without the need to empty the water tank.
1 Remove the
water tank.
2 Open the
drainage outlet
Use pincers to cut away the three securing ribs of the continuous drainage outlet. Remove carefully without letting any debris fall inside.
3 Press drain stopper.
Confirm that the hose does not show signs of
deterioration such as cracks and clogging.
Inspect the hose every 2 weeks.
Insects or dirt blocking the hose may cause leakage resulting in malfunctions.
4 Insert the hose into the drainage
outlet on the back
Feed the commercially available hose (ID 15 mm) into the drainage outlet while keeping the stopper pressed
5 Replace the tank.
The unit cannot operate without returning the tank.
CAUTION
Do not drain water continuously if there is a possibility that temperatures around the hose could drop below freezing point.
Water inside the hose may freeze and water may leak from the unit and damage surrounding objects.
When draining water continuously or left unattended for long periods, inspect the unit once a fortnight.
Foreign objects, etc. could clog the hose resulting in overheating and/or leakage.
Drain
Stopper
Push here
Confirm that the hose is securely attached and does not leak.
How to set up the drainage hose
¡ hose immersed in water ¡ hose raised to a level higher
than the drainage outlet
Hose
Note
19
Troubleshooting
Maintenance
Debris clogging the air filter reduces the effectiveness of the dehumidifier. Clean once every 2 weeks.
Once every two weeks
Air filter
1 Remove front panel and air
filter
Performance of the unit is not affected even if the internal metal fins are slightly bent.
2 Remove the air-purifying filter
The air purifying filter cannot be washed in water. Replace the air purifying filter when it becomes dirty.
3 Clean the air filter
Run a vacuum cleaner lightly over the air filter surface to remove the dirt.
Hose with lukewarm water when excessively soiled. Dry well.
4 Set the air-purifying filter
Set the air-purifying filter into the air filter with the lattice side facing up.
5 Attaching the air filter
Insert the bottom tabs into the unit. Push until you hear a click.
Pull to remove
Air filter
Air purifying filter
Lattice side
2020
Water tank
Wipe with a soft cloth.
Main unit
Wipe with a soft cloth.
Floating element
Do not remove or dismantle.
The unit draws in dust present in the air, and this may cause the tank to gradually become dirty. If the dirt does not come off easily, wash with cold or warm water, then wipe with a soft, dry cloth.
Maintenance
Do not use detergents, cleaning agents for heat exchange equipment, abrasive powders, chemically treated dusters, gasoline, benzene, thinners or other solvents, as they can damage the unit or the water tank, which may result in leakage.
Cleaning
21
Troubleshooting
Replacing the Air Purifying Filter
The air purifying filter is disposable.
Make sure to replace the filter when it becomes dirty. (The filter cannot be washed or reused.)
Storage
After switching the unit off, leave for about one day until any water inside has had time to settle. Then carry out the following steps.
When to replace it
Replace the filter when it becomes dirty (brownish) with cigarette smoke, dust, etc.
Generally, one filter should last about 6 months. (This will depend on usage conditions.)
Replacing air purifying filter
For maintenance procedures see p.
1 Remove front panel and air filter 2 Replace air-purifying filter 3 Attach air filter and front panel
1 Bundle power cord
2 Remove the drainage water.
3 Clean air filter
4 Store the unit.
¡ When you are sure that all parts of
the unit are dry, cover it with a cloth to keep it from dust.
¡ Store the unit in an upright position
in a place not exposed to direct sunlight.
Empty the water tank and wipe away any remaining drops of water.
Remove grit with vacuum cleaner
191719
Air purifying filter for replacement
Type: MJPR-SXFTType code: 5C5 812
For these items contact your nearest Mitsubishi Electric dealer.
Parts sold separately
2222
Troubleshooting
¡ For the symptoms listed below, refer to the remedies listed right.
Symptom
Cause/Remedy
The unit blows warm air
Water does not collect in the water tank (minimal dehumidifying results)
The unit does not turn on (no air comes out) The unit keeps turning off
The humidity level does not reach the level set
The hygrometer reading on the unit differs from other hygrometers in the room
The louvre does not move as set
The water tank contains liquid or white water residue
There is black residue on the inside of the water tank and lid.
Louvre does not swing
¡ Dehumidified air passes through heating coils causing it to
warm (this unit is not a cooler). This is not a malfunction.
¡ Check to see if the temperature/humidity is low.
Low room temperature/humidity reduces dehumidifying effectiveness. Confirm the current humidity reading (in winter, the air is dry reducing dehumidifying effects to zero). This is not a malfunction.
¡ Check to see if the power cord is correctly plugged.
Plug the power cord properly into the power socket.
¡ Check to see if anything is blocking the air intake or outlet.
Remove the obstruction.
¡ Check to see if the air filter is clogged.
Clean according to the maintenance procedures.
¡ Check to see if the unit is in FULL AUTO, MILDEW GUARD, or
AUTO. The unit is automatically controlling the dehumidifier, fan, and standby times.
¡ Check to see if the water tank is full.
Empty the water tank and return it to its original position.
¡ Check to see if the water tank is inserted properly.
Adjust the position of the water tank.
¡ Check to see if the unit is in defrosting mode.
The unit activates defrosting mode when the room temperature drops below 15°C. The dehumidifier and blower functions stop during defrosting.
¡ Check to see if the room is not too large.
Use within effective boundaries (floor space).
¡ Check to see if the exits to the room are open.
Refrain from opening doors/windows during operation.
¡ Check to see if steam producing appliances such as kerosene
heaters are on in the vicinity.
¡ Hygrometer readings differ from place to place even if in the
same room. Use the unit humidity reading as an estimate.
¡ Press the Swing louvre switch again.
¡ The residue is from final product testing at the factory. It is not
a result of a malfunction.
¡ The residue is from debris in the air.
Clean according to the maintenance procedures.
Lights
Lights
19
888
9
4
19
10
~
11
13•16
13
cover
back
11 17
12
23
Troubleshooting
Symptom
Cause/Remedy
¡ Check to see if the unit is on a slope or uneven surface.
Move to a sturdy even surface.
¡ Check to see if the air filter is clogged.
Clean according to the maintenance procedures
¡ Operating the unit in small rooms or in tight spaces sometimes
causes the sound to reverberate. Place a mat underneath the unit.
The unit makes noises
The operating noise is loud/reverberates
The operating sound suddenly increases in volume
The wind sound changes in volume
The unit produces a simmering sound
The unit buzzes intermittently (or the compressor does not activate)
The unit produces an odour
¡ The sound increases when the compressor activates (3
minutes after turning on the unit or during Easy dehumidifier and Automatic modes).
¡
The volume of the sound differs depending on the angle of the louvre.
¡ This is the sound of the refrigerant.
The sound can be heard while the refrigerant stabilizes after the unit turns on, changes modes, or stops.
¡ This is the sound of the compressor.
In modes that monitor the humidity level, the compressor operates intermittently causing the sound to be heard occasionally. The compressor does not activate after turning the unit off, or for 3 minutes after plugging the unit into a power socket. (This is to protect the compressor from damage.)
¡ The heat converter heats rapidly causing an odour. This is not
a malfunction.
Digital display
Cause/Remedy
appears
¡ Error message (Humidity indicator)
appears
appears
~
¡ Check to see if the power cord is plugged into the power
socket properly. Plug the power cord into the power socket properly.
¡ Check to see if anything is blocking the air outlet.
Remove the obstruction, and plug the power cord into the
power socket again.
¡ Check to see if the air filter is clogged.
Clean according to the maintenance procedures.
¡ Malfunction
Unplug the power cord, take note of the error message,
and contact the place of purchase.
If the symptoms persist even after following the prescribed remedies, or the error message does not disappear, unplug the power cord, and contact the place of purchase.
19
19
2
5
9
9
4
9
10~11
12
24
Specifications
Dimensions (h × w × d) 594mm × 372mm × 281mm
Water tank capacity stops automatically at approx. 5.0L
Weight 15.5kg
Power consumption 415W
Power supply Single phase 230-240V 50Hz
Model MJ-E26SX-A1
Dehumidifying capacity 26 L/day
The dehumidifying capacity is a value obtained when the dehumidifier is continuously run at a room
temperature of 30°C and humidity of 80%. It indicates the amount of dehumidification per day (24 hours).
Standby power approximately 2W.
NOTE
It is impossible to remove the back panel because the two spots shown are fastened with two special screws. If the unit malfunctions, contact your Mitsubishi dealer:
Fill in the following for your future reference.
Place of purchase: Telephone number:
Date of purchase: Day Month Year
T939Z126H64
Distributed and guaranteed throughout New Zealand by:
Black Diamond Technologies Ltd.
Auckland Wellington Christchurch
Unit 1, 4 Walls Rd. 1 Parliament St. 37 Mandeville St. PO Box 12726 Penrose PO Box 30772 PO Box 1604 Auckland Lower Hutt Wellington Phone 03 3417052 Phone 09 5269340 Phone 04 5609100 Fax 03 3417054 Fax 09 5253116 Fax 04 5609131
Loading...