Miele T9820 User Manual

Installation instructions for the T 9820 Gas Dryer
The T 9820 gas dryer is only approved for use in the USA and Canada. It is not approved for use in Mexico.
To prevent accidents and machine damage read these instructions
before
installation or use.
en - US, CA
M.-Nr. 07 268 180
2
WARNING
,
For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
ß Do not try to light any appliance. ß Do not touch any electrical switch. ß Do not use any phone in your building. ß Clear the room, building or area
of all occupants.
ß Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
ß If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier. (In Massachusetts a licensed plumber / gas fitter.)
3
Contents
IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Stand ............................................................7
Installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Transporting the dryer to the installation site.............................11
Level the dryer ....................................................11
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Gas connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ducting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
How to calculate the effective duct length ..............................19
Exhaust connection with a flexible exhaust hose or rigid pipe ...............22
Direct wall connection ..............................................24
Caring for the environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4
IMPORTANT SAFETY INSTRUCTIONS
Installation and connection
When using your gas appliance follow basic safety precautions including the following:
Installation, repair and maintenance
~
work should be performed by a qualified installer, service agency or the gas supplier. Work by unqualified persons could be dangerous and could void the warranty.
In Massachusetts:
~
This dryer must be installed by a licensed plumber or gas fitter.
Before installation, disconnect the
~
tumble dryer from the electrical supply by shutting off the power main, unplugging the power cord or tripping the circuit breaker. Do not restore power until the installation is complete.
GROUNDING INSTRUCTIONS
~
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. Only place the plug in an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING – Improper connection of
~
the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
Do not modify the plug provided
~
with the appliance! If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Do not use an extension cord to
~
connect this appliance to the power supply. Extension cords do not guarantee the required safety of the appliance (e.g. danger of overheating).
This dryer must be vented outdoors
~
to reduce the risk of fire. Be sure to observe local building codes.
Use flexible or rigid metal pipe for
~
venting. Non-metallic flexible hose should not be used, it is a potential fire hazard.
5
IMPORTANT SAFETY INSTRUCTIONS
The dryer exhaust must not be
~
connected to a chimney, fireplace ducting, a combustion appliance vent flue, a wall, ceiling or concealed space of a building.
Do not install the machine in rooms
~
where temperatures below freezing may occur.
Proper installation is the
~
responsibility of the installer.
Product failure due to improper
~
installation is not covered under the Warranty.
Gas dryers are not approved for
~
mobile home installation.
If there is any doubt concerning
~
installation, contact Miele’s Technical Service Department.
U 1-800-999-1360
techserv@mieleusa.com
V 1-800-565-6435
service@miele.ca
6
Front view
Installation
a Exhaust connection
b Power cord with plug
c Control panel
d Door
e Four height adjustable screw feet
Stand
A dryer stand, with drawer, can be purchased as an optional accessory.
7
Installation
Rear
a Handle for transportation (arrows)
b Power cord with plug
c Slot for module
d Air intake
e Gas connection
f Vent connection with restriction insert
8
,
WARNING Do not remove the restriction insert in the vent opening. It may result in poor drying results, damage to the laundry and higher Carbon monoxide emissions.
Installation site
WARNING:
,
Do not install the dryer:
- outdoors
- in an environment with dripping water or weather
- near flammable materials
- in rooms which may contain gas or other fuels
- in closets with solid doors
- with other fuel-burning appliances in the same closet
- in a location where its door could conflict with room doors.
- next to a refrigerator
- under a countertop
The National Fuel Gas Code
,
restricts installations of gas appliances in garages. They must be 18 inches off the ground and protected by a barrier from vehicles.
- on top of a washer.
9
Installation site
Confined space installation
When installed in any space with less
^
than 122 square feet, minimum clearances around the dryer must be adhered to for proper ventilation and vents for make up air must be installed.
Do not install any other fuel-burning
^
appliance in the same space as the dryer.
Confined door openings
Any doors limiting circulation must be louvered or otherwise ventilated. A minimum of 200 square inches (1,290 cm must be equally divided within 12" (30.5 cm) from the top and bottom of the door.
2
) of opening is required. It
Minimum installation clearance
Sides: 0"(0cm)
Top: 12" (30.5 cm)
Rear: 0" (0 cm) (as close to wall as
gas connection and venting allows)
Front to door: 2" (5 cm) Make sure the dryer door can open completely once installed.
10
Exhaust duct clearance to combustible material: 2" (5 cm)
Installation
Transporting the dryer to the installation site
The rear of the lid has a handle for transportation.
Use the front dryer feet and the rear
^
of the lid to move the dryer to the installation site.
Level the dryer
The dryer must be level to ensure safe and proper operation.
^
Unscrew the four feet as necessary by turning the foot, 1, and the locking ring, 2, to the left.
^
Once level, hold the foot, 1, still with a wrench. At the same time, turn the locking ring, 2, to the right using another wrench.
,
The dryer lid cannot be removed.
11
Installation
WARNING
,
Before installation, disconnect the tumble dryer from the electrical supply by shutting off the power main or tripping the circuit breaker. Be sure the dryer power cord is unplugged from the wall. Do not restore power until the installation is complete.
Turn the dryer’s gas shutoff valve in the supply line to the OFF position.
Disconnect and discard old flexible gas connector and ducting material.
12
GROUNDING INSTRUCTIONS
,
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. The dryer, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Codes ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
WARNING – Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician, service representative or personnel if you are in doubt as to whether the appliance is properly grounded.
Electrical connection
The dryer is supplied with a 5’ 7" (1.7 m) 3x14 AWG cord and a NEMA 5-15 P plug, ready for connection to a 120 V, 60 Hz, 15 A AC power supply.
Plug the machine into a proper outlet.
^
If the plug does not fit, have a proper outlet installed by a qualified electrician.
,
WARNING – This dryer is
equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding terminal from this plug.
Do not modify the plug! If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
13
Gas connection
WARNING
,
Installation and service must be performed by a qualified installer, service agency or gas supplier.
In Massachusetts a licensed plumber / gas fitter is required.
This appliance must be installed with its own shut off valve in the same room. The valve must be easily accessible to the consumer to turn on or shut off the gas supply after the appliance is installed.
During any pressure testing of the gas system this appliance must be disconnected from the gas supply by closing its individual manual shut off valve.
Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion.
Gas type
The gas dryer is equipped for connection to a NATURAL GAS supply.
The maximum heat output is 19,500 BTU/H (5,7 kW).
An installation kit for conversion from NATURAL to LP gas is available as an optional accessory.
A conversion to LP gas must only be carried out by a Miele Authorized Service Provider and in accordance with all local codes and ordinances.
Minimum gas supply pressure
to obtain the required gas input is:
0.15 psi (4" WC) for natural gas
0.29 psi (8" WC) for LP gas.
Maximum gas supply pressure
before the gas pressure regulator
0.37 psi (10" WC) for natural gas
0.46 psi (13" WC) for LP gas.
The gas installation must be made in accordance with local codes or, in the absence of local codes, with
-National Fuel Gas Code, ANSI Z223.1/NFPA 54 for USA or
-Natural Gas and Propane Installation Code, CSA B149.1 for Canada.
14
Gas supply
Installation material (hoses and adapters) must be provided by the installer.
Gas connection distances
This appliance must be installed with its own shut off valve on the gas supply line. The valve must be within 6 ft. (1.8 m), and in the same room, of the dryer.
1
An
/8" NPT pressure tapping plug must be installed immediately upstream of the gas supply connection. This allows the gas inlet pressure to be checked.
Gas connection
a Flare union adapter
1
b
/8" NPT pressure tapping plug
c Gas shut-off valve
For convenience (if allowed by code), an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas source and the dryer. This will allow the appliance to be moved from the installation site for cleaning or servicing. Make sure that nothing rubs on the gas hose.
If there is any doubt concerning installation, contact the Miele Technical Service Department at the phone number listed on the back of this manual.
15
To secure all connections use
,
appropriate Teon tape orathread compound. Usea10" slip joint wrench only.
^ At the end of the dryer's gas
connection hand screw on the
3
/8" NPT elbow. Using a wrench tighten the elbow withahalf turn.
Gas connection
3
^ Install a
the female elbow, b . Hold the elbow with a wrench.
The maximum amount o orce used should be 531 lb n. (60 Nm).
/8" are union adapter, a , to
^ Secure the gas connection with
Teon tape or thread compound.
^ Secure the exible metal gas line
connector to the adapter.
16
Using two wrenches tighten the
^
flexible gas line connection.
Gas connection
Using two wrenches tighten all
^
connections.
DO NOT OVERTIGHTEN.
,
^
Connect the flare union adapter, a, to the pressure tapping plug, b, originally installed on the gas shut off valve, c.
^
Open the gas shut-off valve.
^
After connecting the appliance check all fittings for gas leaks e.g. with soapy water or an equivalent.
,
WARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS.
17
Ducting
Exhaust ducting and connections
WARNING
,
A gap of3/8" (10 mm) must be provided between the machine and the floor. This gap is necessary for proper air flow and must not be blocked by a toe-kick or thick piled carpets.
Sufficient venting of the installation site is essential for proper dryer operation. Inadequate ventilation will increase energy use and drying times.
Danger of toxic fumes.
The exhaust gases from the dryer must only be vented outside the building.
DO NOT terminate the exhaust ducts in a chimney, fireplace ducting, a combustion appliance vent flue, or enclosed, unventilated area such as attics, garages, crawlspaces, walls, ceilings or concealed space of a building.
To reduce the risk of fire, only use metal ductwork.
18
Ducting
How to calculate the effective duct length
The overall duct length will determine the duct diameter.
Measure the actual duct length
^
needed to go from the dryer’s exhaust connection to the vent outlet:
1. Establish the number of elbows or bends necessary, noting the type of bend, angle and radius involved (see Table).
2. Add the additional duct length (as derived by using the values specified in the table) to the actual duct length to get the effective length.
Note:
Maximum effective duct lengths: 4" (100 mm) diameter 66 ft (20 m) 5" (125 mm) diameter 131 ft (40 m) 6" (150 mm) diameter 328 ft (100 m)
Effective duct lengths over 66 ft (20 m) require a larger duct diameter.
Longer ducts may lead to decreases in dryer efficiency if the next larger duct diameter is not followed.
Tips about the ductwork
Check with your local building code
to determine the maximum allowable duct length.
Rigid metal or flexible aluminum
ducting is preferred. Flexible foil ducting may move and bounce due to the high airflow of the dryer. This could lead to a thumping or grinding noise.
Non-metallic flexible hose should not
be used. It is a potential fire hazard.
For best drying results avoid extra
long ducting with too many bends, angles or tight corners.
– The shorter the exhaust ductwork,
the more efficient the dryer will be. Expelled air is slowed down in the ducts due to friction against the inner walls. The shorter and smoother the inner walls are, the less friction will be created.
An elbow or bend creates more friction than a straight duct. An additional duct length factor must be added for each elbow or bend (see Table). This factor expresses the resistance of the bend in terms of a straight length of duct. The additional length factor is then added to the existing duct to give the effective duct length. A larger duct diameter helps to reduce friction. Therefore duct diameter should be increased if longer duct lengths are required.
19
Ducting
Additional duct lengths (4" (100 mm) rigid pipe only)
Type of bend Radius Additional duct length
inches cm ft cm
Flexible metal duct
3’ 3" (1 m) straight
45° angle
90° angle
Smooth metal duct
3’ 3" (1 m) straight
45° angle
– – 90° angle
Elbow 90° sharp
Concertina bend
– 90° angle 8" 20 2’ 4" 70
10" 10"
10" 10"
25 25
25 25
5’ 11" 4’ 11"
8’ 2"
3’ 3"
1’ 11"
2’ 7"
7’ 6" 230
180 150 250
100
60 80
Wall vent or window vent
with louvers
with flap
with weather hood
20
12’ 5" 4’ 11" 19’ 8"
380 150 600
Example
Ducting
Rigid pipe Duct length
ft
A
B
C
D
Total duct
length
The total duct length is less than 33 feet (10 m), so a duct diameter of 4" (100 mm) with adapter is sufficient.
Wall duct with louvered wall vent
90° bend
20" (0.5 m) rigid pipe
90° bend
12’ 5" 3.8 m
2’ 4" 0.7 m
1’ 7" 0.5 m
2’ 4" 0.7 m
18’ 8" 5.7 m
Duct length
m
21
Ducting
Exhaust connection with a flexible exhaust hose or rigid pipe
Using the connector supplied, an exhaust hose (4" [100 mm] diameter) can be installed.
WARNING
,
Do not remove the restriction insert in the vent opening. It may result in poor drying results, damage to the laundry and higher Carbon monoxide emissions.
Necessary materials:
a wall or window duct
(available from Miele)
an exhaust hose made of approved
non-flammable material
^
Install the required connector*, 1, with the exhaust hose or pipe, 2,to the dryer.
* The white connector with clips is used for connection to a hose; the gray connector without clips is used for connection to a pipe.
The exhaust duct must not be connected or secured with screws or other fastening devices which extend into the interior of the duct.
22
Ducting
Window connection (example)
1 Window duct
2 Connector for the rigid or flexible
exhaust hose
Wall connection (example)
1 Wall pipe (Installation sheet supplied
with the Miele wall pipe)
2 Connector
3 Rigid pipe
23
Ducting
Direct wall connection
Necessary materials:
a wall pipe
flexible foam gasket
Dryer top view
1 Wall pipe
2 Flexible foam gasket
Dryer side view
1 Wall pipe
2 Flexible foam gasket
24
^
Connect the flexible foam gasket, 2, to the wall pipe connector, 1.
^
Push the dryer to the wall.
Caring for the environment
Disposal of the packing materials
The packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable.
To prevent suffocation, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children.
Disposal of an appliance
Old appliances may contain materials that can be recycled. Please contact your local recycling authority about the possibility of recycling these materials.
Ensure that a discarded dryer presents no danger to children. When being stored for disposal remove the door to the drying compartment.
252627
All rights reserved / 0208
For the most updated manual please see the Miele web site.