Miele KWT2661SFS, KWT2611SF, F2671SF, KWT2601Vi, KWT2611Vi Specifications

...
Fully Integrated 24” MasterCool
II
K 2601 Vi / K 2611 Vi
F 2601 Vi* / F 2611 Vi*
KWT 2601 Vi / KWT 2611 Vi
KWT 2661 ViS / KWT 2671 ViS
Shown: KWT 2611 Vi Please note: This information is subject to
*The following models are not available in Canada : F 2601 Vi & F 2611 Vi
change
8miele.ca
Fully Integrated
24” MasterCool II
SPECIFICATIONS
Overall Unit Dimensions 233/4” (604 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel]
Niche
Minimum Cabinet Niche Opening 24” (610 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 243/4” (629 mm) D
Interior Volume K 26x1 Vi KWT 26x1 Vi F 26x1 Vi
Refrigeration Volume ** ** 0
Freezer Volume 0 0 **
Chiller Volume 0 ** 0
Electrical
Electrical Requirements
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 26x1 Vi KWT 26x1 Vi F 26x1 Vi
Water Supply Requirements -
Water Connection Line
Shipping
Shipping Weight 346 lbs (157 kg) 357 lbs (162 kg) 375 lbs (170 kg)
Shipping Dimensions 267/8” (682 mm) W x 841/4” (1,240 mm) H x 297/8” (759 mm) D
Support
Call Miele
Miele Website
20/20 Link
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.
K 26x1 Vi KWT 26x1 Vi F 26x1 Vi
In the case of side-by-side installations, a separate outlet must be used for each appliance.
-
K 26x1 Vi KWT 26x1 Vi F 26x1 Vi
110V / 120V, 60Hz, 15 Amps
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pressure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.
(800) 565-6435
8www.miele.ca
82020technologies.com
K 2601 Vi (Right Hinged)
K 2611 Vi (Left Hinged)
F 2661 Vi (Right Hinged)
F 2671 Vi (Left Hinged)
KWT 2601 Vi (Right Hinged)
KWT 2611 Vi (Left Hinged)
KWT 2661 ViS (Right Hinged)
KWT 2671 ViS (Left Hinged)
Page 2 of 12
CUTOUT DIMENSIONS
Niche depth assumes a 3/4” (19 mm) panel, please
adjust according to custom panel thickness
Fully Integrated
24” MasterCool II
CUTOUT DETAILS
The electrical connection must not be positioned higher
than 9” (228.6 mm) above the oor.
The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the oor.
Notes: In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 12
Fully Integrated
24” MasterCool II
POWER SUPPLY AND WATER CONNECTION (Water Connection For F 26x1 Vi Only)
Rear View Front View
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp
- NEMA 5-15 molded plug Water line - 1/4” exible water line - not included
Side View
Water connection is located in front of unit. 1/4” compression tting is needed.
Electrical Connection
Page 4 of 12
Loading...
+ 8 hidden pages