Miele KWT 1613 Vi, KWT 1603 Vi, KF 1913 Vi, KF 1813 Vi, KF 1803 Vi User Manual

...
MasterCool Refrigeration Side-by-Side Merging Combinations For Vi Models
8mieleusa.com
Side-by-Side Merging Kit
en
en
KSK 1002
This merging kit should be used for side-by-side installation of the following models:
– K 18x1 Vi, K 19x1 Vi,
K 18x3 Vi, K 19x3 Vi
– F 14x1 Vi, F 18x1 Vi,F19x1Vi
F 14x3 Vi, F 18x3 Vi,F19x3Vi
– KF 18x1 Vi, KF 19x1 Vi,
KF 18x3 Vi, KF 19x3 Vi
– KWT 16x1 Vi, KWT 16x3Vi
Side-by-side
...without partition
If the appliances are installed directly next to each other (without a partition), they need to be attached together. A heating mat must also be installed. This will help avoid condensation and prevent damages.
...withpartition
The minimumthicknessofthe partition
5
is
/8"(16 mm).
If thereisapartition withathickness
5
from
/8"(16 mm)to65/16" (160 mm)
betweenthe adjacentappliances, then each appliance should be individually installed within itsown niche using the mountingaccessories included.
In this case,you will only need the heating matfrom the "Merging Kit" to avoid condensationand prevent damages.
Page 2 of 7
Product and Cut-out Dimensions 48” Side-by-Side Combination F14X3 & K18X3
FOR FLUSH INSTALLATION
25" min.*
29 3/4"
84"
24 5/8"
O
48"
E
10 1/4"
17 3/4"
83 1/2" - 85 3/8"
UNITS ACCEPT CUSTOM
FRONT PANELS
See individual spec files for details
Location Codes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
E -
supply connects lower left rear
One (1)Standard NEMA 5-15 Duplex Outlet - locate
O -
less than 9" above finished floor
Notes
KSK1002 Merging kit must be used when combining units
All Installations must be done in accordance with local codes
Sides of adjoining cabinets should be filled (flush to frame) to insure proper fit and finish
For Proud Installation — please adjust accordingly
*Depth assumes a 3/4" panel, please adjust according to custom panel thickness
1 1/8"
4 1/8"
"8/3 8 - "2
"2/1 8 - "8/5 6
Page 3 of 7