MasterCool Refrigeration
Side-by-Side Merging Combinations
For Vi Models
8mieleusa.com
Side-by-Side Merging Kit
KSK 1002
This merging kit should be used for
side-by-side installation of the following
models:
– K 18x1 Vi, K 19x1 Vi,
K 18x3 Vi, K 19x3 Vi
– F 14x1 Vi, F 18x1 Vi,F19x1Vi
F 14x3 Vi, F 18x3 Vi,F19x3Vi
– KF 18x1 Vi, KF 19x1 Vi,
KF 18x3 Vi, KF 19x3 Vi
– KWT 16x1 Vi, KWT 16x3Vi
Side-by-side
...without partition
If the appliances are installed directly
next to each other (without a partition),
they need to be attached together. A
heating mat must also be installed. This
will help avoid condensation and
prevent damages.
...withpartition
The minimumthicknessofthe partition
5
is
/8"(16 mm).
If thereisapartition withathickness
5
from
/8"(16 mm)to65/16" (160 mm)
betweenthe adjacentappliances, then
each appliance should be individually
installed within itsown niche using the
mountingaccessories included.
In this case,you will only need the
heating matfrom the "Merging Kit" to
avoid condensationand prevent
damages.
Page 2 of 7
Product and Cut-out Dimensions
48” Side-by-Side Combination
F14X3 & K18X3
FOR FLUSH INSTALLATION
25" min.*
29 3/4"
84"
24 5/8"
O
48"
E
10 1/4"
17 3/4"
83 1/2" - 85 3/8"
UNITS ACCEPT CUSTOM
FRONT PANELS
See individual spec files for details
Location Codes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
E -
supply connects lower left rear
One (1)Standard NEMA 5-15 Duplex Outlet - locate
O -
less than 9" above finished floor
Notes
• KSK1002 Merging kit must be used when
combining units
• All Installations must be done in accordance
with local codes
• Sides of adjoining cabinets should be filled
(flush to frame) to insure proper fit and finish
• For Proud Installation — please adjust accordingly
*Depth assumes a 3/4" panel, please adjust according
to custom panel thickness
1 1/8"
4 1/8"
"8/3 8 - "2
"2/1 8 - "8/5 6
Page 3 of 7