Miele KWT 1603 SF, KF 1913 SF, KF 1903 SF, KF 1813 SF, K 1903 SF User Manual

...
MasterCool Refrigeration Side-by-Side Merging Combinations For SF Models
8mieleusa.com
Side-by-Side Merging Kit
en
en
KSK 1002
This merging kit should be used for side-by-side installation of the following models:
– K 18x1 SF, K 19x1 SF,
K 18x3 SF, K 19x3 SF
– F 14x1 SF, F 18x1 SF, F 19x1 SF
F 14x3 SF, F 18x3 SF, F 19x3 SF
– KF 18x1 SF, KF 19x1 SF,
KF 18x3 SF, KF 19x3SF
– KWT 16x1 SF, KWT 16x3 SF
Side-by-side
...without partition
If the appliances are installed directly next to each other (without a partition), they need to be attached together. A heating mat must also be installed. This will help avoid condensation and prevent damages.
...withpartition
The minimumthicknessofthe partition
5
is
/8"(16 mm).
If thereisapartition withathickness
5
from
/8"(16 mm)to65/16" (160 mm)
betweenthe adjacentappliances, then each appliance should be individually installed within itsown niche using the mountingaccessories included.
In this case,you will only need the heating matfrom the "Merging Kit" to avoid condensationand prevent damages.
Page 2 of 12
Product and Cut-out Dimensions 48” Side-by-Side Combination F14X3 & K18X3
FOR PROUD INSTALLATION
24" min.
29 3/4"
84"
24 5/8"
O
48"
E
10 1/4"
17 3/4"
83 1/2" - 85 3/8"
Location Codes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
E -
supply connects lower left rear One (1) Standard NEMA 5-15 Duplex Outlet - locate less
O -
than 9" above finished floor
Notes
KSK1002 Merging kit must be used when combining units
•All Installations must be done in accordance with local codes
"8/3 5 - "2/1 3
1 1/8"
Page 3 of 12
Product and Cut-out Dimensions 48” Side-by-Side Combination F14X3 & K18X3
FOR FLUSH INSTALLATION
25" min.
29 3/4"
84"
24 5/8"
O
48"
E
10 1/4"
17 3/4"
83 1/2" - 85 3/8"
Location Codes
5 foot - 120 Volt - 15 Amp 3-wire molded plug power
E -
supply connects lower left rear One (1) Standard NEMA 5-15 Duplex Outlet - locate less
O -
than 9" above finished floor
Notes
KSK1002 Merging kit must be used when combining units
•All Installations must be done in accordance with local codes
Sides of adjoining cabinets should be filled (flush to frame)