Miele KMR1124 G, KMR1134 G, KMR1136 G, KMR1135 G, KMR1354 G Installation Instruction

...
Installation Instructions
KMR1124 G, KMR1134 G, KMR1135 G KMR1136 G, KMR1354 G, KMR1355 G KMR1356 G en - CA
Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
Notes on installation
38
Distance to the range hood
The minimum clearance between the appliance an
d a range hood above will
be listed by the hood manufacturer. If there is more than one appliance in‐
stalle
d below the range hood, each with a different safety clearance, the largest clearance must be used.
Notes on installation
39
Weights
The net weight of the rangetop with accessories is as follows:
Model Width Net weight incl. acces‐
sories: KMR 1124 G/LP 30" approx. 100 lbs / 45 kg KMR 1134 G/LP
KMR 1135 G/LP KMR 1136 G/LP
36"
approx.120 lbs / 55 kg
ap
prox. 130 lbs / 60 kg
approx. 151 lbs / 68.5 kg
KMR 1354 G/LP KMR 1355 G/LP KMR 1356 G/LP
48"
approx. 150 lbs / 68 kg ap
prox. 160 lbs / 73 kg
approx. 170 lbs / 78 kg
Dimensional drawings
40
I
n case of the presence of combustible material an additional minimum clear‐
ance of 6“ (each side) is necessary. Ensure local codes are observed.
Position Dimension Description
13" (330 mm) Maximum depth of top cabinet
18" (457 mm) Minimum distance to bottom edge
of t
op cabinet
7¹/₂" (190.5 mm) Distance top edge of worktop to
t
op edge of platform
10" (254 mm) Minimum distance to flammable
sur
faces
Platform
1)
1) The Platform must be ³/₄" (19.05 mm) thick. It must include a cut-o
ut of 5¹/₈" x 3¹/₈" (130 mm x 80 mm) (gas connection) at the rear right
and a cut-out of 4³/₄" x 1⁹/₁₆" (120 mm x 40 mm) (elctrical connection) at the rear left.
Dimensional drawings
41
KMR 1124
Position Dimension Description
min. 30"
(762 mm)
Width of cabinet opening
6“ + + 6"
(150 mm + + 150 mm)
In case of the presence of com‐ bustible mat
erial an additional min‐ imum clearance of 6“ (each side) is necessary. Ensure local codes are observed.
37" (940 mm) Minimum distance between the top
of the cookin
g area and the bottom of an unprotected combustible sur‐ face.
30" (762 mm) Minimum distance between the top
of the cookin
g area and the bottom of the Miele Range Hood (DAR model with DRxB XL Blower).
For all other Hoods, please consult with manufacturer's instructions for required distances.
Dimensional drawings
42
KMR 1134
Position Dimension Description
min. 36"
(914 mm)
Width of cabinet opening.
6“ + + 6"
(150 mm + + 150 mm)
In case of the presence of com‐ bustible mat
erial an additional min‐ imum clearance of 6“ (each side) is necessary. Ensure local codes are observed.
37" (940 mm) Minimum distance between the top
of the cookin
g area and the bottom of an unprotected combustible sur‐ face.
36" (914 mm) Minimum distance between the top
of the cookin
g area and the bottom of the Miele Range Hood (DAR model with DRxB XL Blower).
30" (762 mm) Minimum distance between the top
of the cooking area and the bottom of the Miele Range Hood (DAR model with DRxB XXL Blower).
For all other Hoods, please consult with manufacturer's instructions for r
equired distances.
Loading...
+ 14 hidden pages