Miele K2811Vi, K2801Vi, F2801Vi, F2811Vi Specifications

Fully Integrated 30” MasterCool II
All Refrigerator:
K 2801 Vi / K 2811 Vi
All Freezer:
F 2801 Vi / F 2811 Vi
Bottom Mount:
KF 2801 Vi / KF 2811 Vi
Shown: F 2471 Vi merged with K 2801 Vi Please note: This information is subject to change
Specification Sheets TRS 04252019
Fully Integrated
30” MasterCool II
SPECIFICATIONS
Overall Unit Dimensions 293/4” (756 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel]
Niche
Minimum Cabinet Niche Opening 30” (762 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 243/4” (629 mm) D
Interior Volume K 28x1 Vi F 28x1 Vi KF 28x1 Vi
Refrigeration Volume ** 0 **
Freezer Volume 0 ** *
Electrical
Electrical Requirements
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 28x1 Vi F 28x1 Vi KF 28x1 Vi
Water Supply Requirements -
Water Connection Line
Shipping
Shipping Weight 395 lbs (179 kg) 399 lbs (181 kg) 450 lbs (204 kg)
Shipping Dimensions 335/8” (950 mm) W x 8913/16” (1,294 mm) H x 291/4” (800 mm) D
Support
Call Miele
Miele Website
20/20 Link
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.
K 28x1 Vi F 28x1 Vi KF 28x1 Vi
In the case of side-by-side installations, a separate outlet must be used for each appliance.
-
K 28x1 Vi F 28x1 Vi KF 28x1 Vi
110V / 120V, 60Hz, 15 Amps
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pres­sure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.
(800) 565-6435
8www.miele.ca
82020technologies.com
K 2801 Vi (Right Hinged)
K 2811 Vi (Left Hinged)
F 2801 Vi (Right Hinged)
F 2811 Vi (Left Hinged)
KF 2801 Vi (Right Hinged)
KF 2811 Vi (Left Hinged)
Page 2 of 10
CUTOUT DIMENSIONS
Niche depth assumes a 3/4” (19 mm) panel, please
adjust according to custom panel thickness
Fully Integrated
30” MasterCool II
CUTOUT DETAILS
The electrical connection must not be positioned higher
than 9” (228.6 mm) above the oor.
The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the oor.
Notes: In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 10