MasterCool Refrigeration
Side-by-Side Merging Combinations
For Vi Models
Specification Sheets TRS 12082015
8mieleusa.com
Side-by-Side Merging Kit
KSK 1002
SPECIFICATIONS
KSK 1002 — Item 38996010USA
Electrical
Electrical Requirements - Volts/Amps
Power Cord - Plug and length NEMA 1-15 plug, 9’ 3” ft (2.8 m)
Support
Call Miele 800.843.7231
Miele Website
20/20 Link
This merging kit should be used for side-by-side installation of the following
models:
- K 18x1 Vi, K 19x1 Vi, K 18x3 Vi, K 19x3 Vi
- F 14x1 Vi, F 18x1 Vi, F 19x1 Vi, F 14x3 Vi, F 18x3 Vi, F 19x3 Vi
- KF 18x1 Vi, KF 19x1, Vi, KF 18x3 Vi, KF 19x3 Vi
- KWT 16x1 Vi, KWT 16x3 Vi
110V / 120V, 60Hz, 15 Amps
In a side-by-side installations, a separate outlet
must be used for each appliance.
8www.mieleusa.com
82020technologies.com
Specification Sheets TRS 12082015
Page 2 of 12
Side-by-Side Merging Kit
...withpartition
The minimumthicknessofthe partition
is
5
/8"(16 mm).
If thereisapartition withathickness
from
5
/8"(16 mm)to65/16" (160 mm)
betweenthe adjacentappliances, then
each appliance should be individually
installed within itsown niche using the
mountingaccessories included.
KSK 1002
Side-by-side
...without partition
If the appliances are installed directly
next to each other (without a partition),
they need to be attached together. A
heating mat must also be installed. This
will help avoid condensation and
prevent damages.
TRANSFORMER PLUG DETAILS
...withpartition
The minimumthicknessofthe partition
5
is
/8"(16 mm).
If thereisapartition withathickness
5
from
/8"(16 mm)to65/16" (160 mm)
betweenthe adjacentappliances, then
each appliance should be individually
installed within itsown niche using the
mountingaccessories included.
In this case,you will only need the
heating matfrom the "Merging Kit" to
avoid condensationand prevent
damages.
9 foot- 120Volt- 15Amp 2-wire molded plug power
supply
Note: Niche depth under 25” (635 mm) will require the location
of the Electrical outlet(s) to be in adjacent cabinetry
•
KSK1002 Merging kit must be used when combining units
•
All Installations must be done in accordance with local codes
Specification Sheets TRS 12082015
Page 3 of 12
Product and Cut-out Dimensions
42” Side-by-Side Combination
F14X3 Vi & KWT1603 Vi
FOR FLUSH INSTALLATION
FOR FLUSH INSTALLATION
Specification Sheets TRS 12082015
Page 4 of 12