Side-by-Side Merging Kit KSK 1002
SPECIFICATIONS
KSK 1002 — Item 38996010USA
Electrical
Power Cord - Plug and length NEMA 1-15 plug, 9’ 3” ft (2.8 m)
Support
Call Miele 800.843.7231
Miele Website
20/20 Link
This merging kit should be used for side-by-side installation of the following models:
- K 18x1 Vi, K 19x1 Vi, K 18x3 Vi, K 19x3 Vi
- F 14x1 Vi, F 18x1 Vi, F 19x1 Vi, F 14x3 Vi, F 18x3 Vi, F 19x3 Vi
- KF 18x1 Vi, KF 19x1, Vi, KF 18x3 Vi, KF 19x3 Vi
- KWT 16x1 Vi, KWT 16x3 Vi
110V / 120V, 60Hz, 15 Amps In a side-by-side installations, a separate outlet must be used for each appliance.
8www.mieleusa.com
82020technologies.com
Specification Sheets TRS 12082015
Page 2 of 12
Side-by-Side Merging Kit
en
...withpartition
The minimumthicknessofthe partition is
5
/8"(16 mm).
If thereisapartition withathickness
from
5
/8"(16 mm)to65/16" (160 mm)
betweenthe adjacentappliances, then each appliance should be individually installed within itsown niche using the mountingaccessories included.
KSK 1002
Side-by-side
...without partition
If the appliances are installed directly next to each other (without a partition), they need to be attached together. A heating mat must also be installed. This will help avoid condensation and prevent damages.
TRANSFORMER PLUG DETAILS
...withpartition
The minimumthicknessofthe partition
5
is
/8"(16 mm).
If thereisapartition withathickness
5
from
/8"(16 mm)to65/16" (160 mm)
betweenthe adjacentappliances, then each appliance should be individually installed within itsown niche using the mountingaccessories included.
In this case,you will only need the heating matfrom the "Merging Kit" to avoid condensationand prevent damages.
9 foot- 120Volt- 15Amp 2-wire molded plug power supply
Note: Niche depth under 25” (635 mm) will require the location of the Electrical outlet(s) to be in adjacent cabinetry
KSK1002 Merging kit must be used when combining units
All Installations must be done in accordance with local codes
Specification Sheets TRS 12082015
Page 3 of 12