Miele HR11361GDLP, HR11351GRG, MIRERADWRH380, HR19362DFGDLP, MIRERADWRH292 Specs

36” All Gas Range
HR 1134-1 G/LP, HR 1135-1 G, HR 1136-1 G/LP
36” Dual Fuel Range
HR 1934-2 DF G/LP, HR 1935-2 DF G, HR 1936-2 DF G/LP
Specication Sheet TRS 03192018
8mieleusa.com
36” All Gas and Dual Fuel Range
SPECIFICATIONS
Overall Unit Dimensions 3515/16” (915 mm) W x 351/2” — 37” (902 — 940 mm) H x 261/2” (678 mm) D [Depth to control panel]
Oven Door Clearance 25” (635 mm)
Niche
Minimum Cabinet Niche Opening 36” (915 mm) W x 351/2” (901 mm) H
Gas
Gas Line Connection 1/2” NPT
Operational Altitudes
Miele Natural Gas and LP Ranges will function up to 9,800 ft. in altitude without adjustment; the following excep-
High Altitude
Electrical
Electrical Requirements
Power Cord
Plumbing
Plumbing Requirements
Plumbed Hose Connection
Shipping HR 113x-1 HR 193x-2 DF
Shipping Weight 448.6 lbs (203.5 kg)
Shipping Dimensions 435/16” (1100 mm) W x 52” (1,294 mm) H x 311/2” (800 mm) D
Installation Accessories HR 113x-1 HR 193x-2 DF
12” Backguard RBGAG1236 RBGDF1236
20” Backguard RBGAG2036 RBGDF2036
40” Backsplash RBS36 RBS36
Support
Call Miele (800) 999-1360
Miele Website
20/20 Link
tion will function up to 6,500 ft. in altitude without adjustment:
• Griddle in LP: HR 1136-1 LP, HR 1936-2 LP, HR 1956-2 LP
• Grill in G: HR 1135-1 G, HR 1935-1 G, HR 1955-1 G If an installation exceeds these elevations, please contact rangejetkit@mieleusa.com.
HR 113x-1 HR 193x-2 DF
120V, 60Hz, 15A 120/208-240V, 60Hz, 30A
NEMA 5-15p, 5’ 11” (1.8m) NEMA 14-30p, 5’ 11” (1.8m)
HR 113x-1 HR 193x-2 DF
An Inline water lter, like activated carbon, is required to reduce mineral deposits.
-
-
Do not connect to a Reverse Osmosis (RO) water system. Connect to a cold water supply only. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pressure must be between 14.5 and 145 psi (1 and 10 bars). If the pressure is higher, install a pressure reducing valve.
Supplied hose: flexible braided 4’11” (1.5 m) with 3/8” O.D. compression fitting for connection to a shut off valve. The total hose length must not exceed 24.5 ft. (7.5 m).
8www.mieleusa.com
82020technologies.com
Duel Fuel:
Only Burners: With Grill: With Griddle:All Gas:
HR 1134-1 Item 25113461USA
HR 1134-1 LP Item 25113462USA
HR 1934-2 DF Item 25193471USA
HR 1934-2 DF LP Item 25193472USA
HR 1135-1 Item 25113561USA
HR 1935-2 DF Item 25193571USA
HR 1136-1 Item 25113661USA
HR 1136-1 LP Item 25113662USA
HR 1936-2 DF Item 25193671USA
HR 1936-2 DF LP Item 25193672USA
Page 2 of 5
Loading...
+ 3 hidden pages