PureLine
30” Convection Oven
H 6880 BP
8mieleusa.com
PureLine 30” Convection Oven
H 6880 BP
H 6880 BP
Features:
• M Touch controls are both easy to
operate and navigate. An intuitive
swipe of the screen will quickly lead
you to your desired selection
• Self Clean Oven
• 19 Operating Modes including
Moisture Plus (plumbed only)
increases the humidity in the oven
optimizing the cooking of a variety of
foods
• MasterChef Plus — fully functional
automatic programs to create 15
different types of bread at home
• MasterChef menu offers over 100
food types to cook to perfection
• Wireless Roast Probe for safe. easy
handling and perfect roasting results
• Favorites — up to 20 recipes
• Sabbath Program
• CleanGlass Door
• TwinPower Fans provide optimum
and even distribution of hot air
• Soft Open and Soft Close for
easier handling
• The simple yet sleek Silhouette
handle seems to oat enhancing its
modern design lines
H 6880 BP
Page 2 of 7
PureLine 30” Convection Oven
H 6880 BP
SPECIFICATIONS
H 6880 BP — Item
Overall Unit Width - Excluding Fascia Dimension 287/16” (722mm)
Overall Height - Excluding Fascia Dimension 27
Overall Unit Depth - Excluding Fascia Dimension 23
Oven Door Clearance 23” (584mm)
Overall Oven Interior Capacity 4.63 cu.ft - 131.24 liters
Overall Fascia Dimensions
Oven Interior Dimensions
Built-In
Minimum Cabinet Width 28
Minimum Cabinet Depth 24” (610mm)
Minimum Cabinet Opening Height 28
Minimum Base Support 193 lbs
Additional Cut-outs Required
Plumbing
Plumbing Requirements
Electrical
Electrical Requirements 208/240V 30A 60Hz circuit
Power Cord Yes - NEMA 14-30 plug
Electrical Rating
Total Amps 240V / 24.166A / 208V / 21.15A
Shipping
Shipping Weight 216 lbs
Shipping Dimensions 32
Support
Call 800.843.7231
20/20
22688053USA
3
/4” (705mm)
3
/4” (603mm)
13
29
/16” (757mm) W x 285/8” (727mm) H
7
/8” (23mm) D
x
1
/2” (622mm) W x 165/8”(423mm) H
24
1
/4” (464mm) D
x 18
1
/2” (724mm)
1
/4” (718mm)
Venting cut-out required at base of cabinet
(4” x 28” / 100mm x 720mm) in the bottom
of the cabinet for power cord and ventilation
An Inline water filter, like activated carbon, is
required to reduce mineral deposits. Do not
connect to a Reverse Osmosis (RO) water
system. Connect to a cold water supply only
not to exceed 140°F (60°C). Must be connected to a shut-off valve. The water shut-off
valve must be accessible after installation.
The water pressure must be between 14.5
and 145 psi (1 and 10 bars). If the pressure is
higher, install a pressure-reducing valve. The
supplied hose has a length of 4’ 11” (1.5 m).
The hose must not be shortened.
120/208V, 30A, 60Hz 5800w /
120/240V, 30A, 60Hz 4400w
11
/16” W x 351/16” H x 305/16” L
82020technologies.com
H 6880 BP