/4” (451 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel]
3
/16” (2134 - 2164 mm) H x 243/4” (629 mm) D
F 24x1 Vi
110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be
connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pressure
must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure
reducing valve must be installed.
Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10
mm). Water line is not included.
F 2411 ViF 2461 Vi / F 2471 Vi
1
/16” (535 mm) W x 841/4” (1,240 mm) H x 297/8” (759 mm) D
8www.mieleusa.com
82020technologies.com
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of
the Heating Mat/Merge Kit.
F 2411 Vi (Left Hinged)
Item 37241101USA
F 2461 Vi (Right Hinged)
Item 37246101USA
F 2471 Vi (Left Hinged)
Item 37247101USA
Page 2 of 9
CUTOUT DIMENSIONS
• Niche depth assumes a 3/4” (19 mm) panel, please
adjust according to custom panel thickness
Fully Integrated
18” MasterCool
CUTOUT DETAILS
• The electrical connection must not be positioned higher
than 9” (228.6 mm) above the oor.
• The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the
oor.
Notes:
In case of an emergency the electrical outlet must be
easily accessible and must not be concealed behind the
appliance.
Page 3 of 9
Fully Integrated
18” MasterCool
POWER SUPPLY AND WATER CONNECTION
Rear ViewFront View
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp
- NEMA 5-15 molded plug
Water line - 1/4” exible water line - not included
Side View
Water connection is located in front of unit.
1/4” compression tting is needed.
Electrical
Connection
Page 4 of 9
appearance
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied by
the
cabinets
Panel
Panel Notes
If
Simply
Fully Integrated
18” MasterCool | F 2411 Vi
CUSTOM PANEL INSTALLATIONS
cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surrounding
.
size is determined in the following manner:
Miele
Fully Integrated
Freezer
Panel Height
Width:29 3/4" in all cases
Thickness:Minimum 3/4" outside frame
Height: Determined using the following calculation:
Panel Height = HOC - TKH
HOC = Total height of cabinet or side panel
TKH = Toe-kick height
HOC
Note:Finish back side of panels to insure
Panel may extend above unit. This is not
considered in height calculation
Minimum 17 3/4” (451 mm)
Minimum 3/4” (19 mm) outside frame
the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly.
maintain the toekick height and extend the panel the needed distance.
Adjoining cabinet
TKH
Extended Panel
Maximum panel weight:105.8 Pounds
123 Pounds
Machine
Page 5 of 9
DOOR PANEL DIMENSIONS
KFP1804 - Door Panel
Available as an accessory
for the following models:
• F 2411 Vi
Fully Integrated
18” MasterCool | F 2411 Vi
Page 6 of 9
Fully Integrated
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied by
the
cabinets
Panel
Panel "B" Height
Width:29 3/4" in all casesThickness:Minumum 3/4" outside frame
Standard Upper Panel Height:53 5/16"
Note:Finish back side of panels to insure appearance
Panel may extend above unit. This is notconsidered in height calculation
Upper Maximum panel weight :103.6 Pounds
Lower Panel Height:Use the following calculation:
Panel Height =HOM - 53 9/16 - TKH
HOM=Total height of machine. Can be adjusted to
match adjoining cabinets- typically 84"HOM is adjustable between 83 1/2" - 85 3/8"
TKH=Toe-kick height (2" - 8 3/8")
Lower Maximum panel weight:22 Pounds
Upper Panel
TKH
HOM
Panel Height
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Lower Panel
Upper Panel Notes
Width:17 3/4" in all cases
Thickness:Minimum 3/4" outside frame
Height:Determined using the following calculation:
Panel Height = HOC - TKH
HOC= Total height of cabinet or side panelTKH= Toe-kick height
Note:Finish back side of panels to insure appearance
Panel may extend above unit. This is notconsidered in height calculation
Maximum panel weight:143.3 Pounds
Miele
Fully Integrated
Freezer
TKH
HOC
Panel Height
These units do not come equipped with a front panel. They are designed to accept a custom door panel supplied bythe cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surroundingcabinets.
Panel size is determined in the following manner:
Panel Notes
If
Simply
18” MasterCool | F 2461 Vi / F 2471 Vi
CUSTOM PANEL INSTALLATIONS
CUSTOM PANEL INSTALLATIONS
cabinet maker. Miele has a unique panel integration system which allows the panels to align with the surrounding
.
size is determined in the following manner:
Miele
Fully Integrated
Freezer
Panel Height
Width:17 3/4" in all cases
Thickness:Minimum 3/4" outside frame
HOC
Height: Determined using the following calculation:
Panel Height = HOC - TKH
HOC = Total height of cabinet or side panel
Note:Finish back side of panels to insure appearance
Maximum panel weight:143.3 Pounds
TKH = Toe-kick height
Panel may extend above unit. This is not
considered in height calculation
17 3/4” (451 mm) in all cases
Minimum 3/4” (19 mm) outside frame
143 Pounds
the adjoining cabinets are taller than the height of machine (HOM) - the front panel may be extended accordingly.
maintain the toekick height and extend the panel the needed distance.
Adjoining cabinet
TKH
Extended Panel
Machine
Page 7 of 9
DOOR PANEL DIMENSIONS &
DISPENSER CUTOUT
KFP 1844 - Door Panel
Available as an accessory
for the following models:
• F 2461 Vi
• F 2471 Vi
Fully Integrated
18” MasterCool | F 2461 Vi / F 2471 Vi
Page 8 of 9
0-3/4"
1"
1-1/4"
1-1/2"
0-1/8"
F
ro
nt
Pa
n
el
0-3/4"
1-1/4"
1-1/2"
1-3/4"
1"
Cabinet Front
rooD°511rooD°09
snoitpossenkcihTsnoitpossenkcihT
HINGING DETAILS 115° OPENING
0-3/4"
1"
1-1/4"
1-1/2"
0-1/8"
F
ro
nt
Pa
n
el
0-3/4"
1-1/4"
1-1/2"
1-3/4"
1"
CabinetFront
rooD°511rooD°09
snoitpossenkcihTsnoitpossenkcihT
Door Swing
Available for the following models:
• F 24x1 Vi
1-1/4” (32 mm)
1-1/2” (38 mm)
1-3/4” (44 mm)
0-3/4” (19 mm)
1” (25 mm)
Fully Integrated
18” MasterCool
0-3/4” (19 mm)
2-5/8”
(67mm)
2-5/8”
(67mm)
2-1/3” (59mm)
2-1/3” (59mm)
2-1/24”(52mm)
2-1/24”(52mm)
1-3/8”(35mm)
1-3/8”(35mm)
1-1/6”
1-1/6”
17/24” (18mm)
17/24” (18mm)
(29.6mm)
(29.6mm)
1/4”(6.4mm)
1/4”(6.4mm)
1-3/4”(44.5mm)
1-3/4”(44.5mm)
3”(76.2mm)
3”(76.2mm)
0-1/8” (3 mm)
DOOR SWING AT 115° OPENING
1-1/2” (38 mm)
1” (25 mm)
1-1/4” (32 mm)
11 3/4”
16 7/8"
(298 mm)
MAX
Max
NOTE: Additional space needed depending on
thickness of front panels and handle used
Specification Sheets TRS 05202019
Page 9 of 9
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.