1. INTRODUCTION
Welcome to use
MicW
series professional microphones!
MicW
N101 has outstanding characteristics that make the microphone a valuable tool in
the studio, measurement and on the stage.
2. SAFETY INSTRUCTION
It is important to read all safety precautions and operating instructions before attempting to operate the unit. Keep all safety precautions and operating instructions for future reference.
Warning:
Condenser microphones are extremely moisture-sensitive. Never use your microphone in close proximity to water (e.g. bath tubs, wash basins, sinks, washing machines, pools, etc.). When doing voice recordings, always use the enclosed windscreen to safely protect the capsule from moisture.
Please don’t touch the vibration parts especially the diaphragm behind the protection grid. Don’t move the capsule when it is in operation. Take care not to drop your microphone as this can lead to severe damage.
MicW
assumes no liability for any
damage caused by the user. After each use, place it back into its protective casing. Then, lay the small bag
containing the moisture-absorbing crystals on top of the microphone head.
3. POWER SUPPLY
Phantom power (+48 V) is required to operate your microphone. We assume no liability for damage caused to your N101 through defective phantom power. Before activating phantom power, mute your playback system and connect the N101 to the microphone input of your mixing console. After activating phantom power, the N101 requires several seconds to stabilize itself.
4. APPLICATIONS
The
MicW
N101 is a state-of-the-art stereo kit. Therefore, it is particularly well-suited for stereo recordings. Regardless of whether you are milking an entire ensemble or a single sound source (e.g. drums, piano or background vocals), this microphone lets you achieve outstanding spatial impressions in every recording session.
Of course, you can use
MicW
N101-pair that feature two matched N101 microphones as well. Each pair is guaranteed to the sensitivity match within 0.5 dB and phase match within 5°.
The
MicW
M101 is a measurement microphone. Its frequency response meets IEC61672 Class 1 requirements. Each M101 microphone is individually calibrated and aged at high temperature for long-term stability and reliability. It is good choice for use in measurements.
5. MICROPHONE INSTALLATION
First screw a clamp onto the stand before attaching the microphone itself.
6. AUDIO CONNECTION
To connect the N101 to your equipment, use a balanced XLR microphone cable with the following pin assignment: Pin 1 = shielding, pin 2 = +, pin 3 = -. Since all contact points of the N101 are gold-plated, your microphone cable should feature gold-plated connectors, if possible.
7. Directional characteristic
The microphone features a capsule with Omni pickup pattern. Microphones with this polar pattern are most sensitive to sound coming from in each angle of the microphone.