MGE UPS Systems 300 User Manual

www.mgeups.com
www.mgeups.com
1660 Scenic Avenue Costa Mesa, CA 92626
Compact UPS
for Home or Small Office Use
ellipse
UPS 300 - 1200 VA
MADE IN THE US from imported parts
Product Features & Benefits
Feature Benefit
• High frequency technology Reduces heat and interaction with monitor
• UPS and surge outlets Protects critical loads from outages and peripherals from surges
• Flat rotating input plug Improves flexibility in locating UPS by reducing space for plug
• Overload circuit breaker Provides overload protection
• Status LEDs Provides status of UPS and of faulty wiring
• Battery door on UPS Provides convenient battery replacement (exc.1200)
• USB and RS232 availability Provides automatic shutdown of critical load
with free downloadable software and monitoring of UPS by PC
MGE UPS Systems
Ellipse User’s Manual
page 1
Page
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . inside front cover
Product Features & Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
MGE UPS Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Why the Need for Uninterruptible Power? . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Battery Charger/Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Instructions for Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Set Up, Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
LED and Audible Alarm Operation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Getting Maximum Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Battery Replacement for 300/500/650/800 Models . . . . . . . . . . . . . . . . . . . . .4
Battery Replacement for Ellipse Model 1200 . . . . . . . . . . . . . . . . . . . . . . . . .5
Performance & Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Run Time Chart for Various Loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Model Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Service & Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Service and Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
UPS Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
US and Canada Domestic Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Maintenance Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Other Fine MGE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Contents
MGE UPS Systems
86-153506-00 Rev. A01
January 2000
Important Safety Instructions. Save These Instructions.
This manual contains important instructions for Ellipse that should be followed during installation and maintenance of the UPS and batteries.
This equipment can be operated by an
individual, with no previous training.
All repairs should be
performed by qualified personnel.
The UPS contains
voltages which are potentially hazardous.
CAUTION: Risk of electric shock, even with unit disconnected from AC power source. Hazardous voltage still may be present through operation from battery. The battery should be disconnected at the plus (+) and minus (-) terminals using the fast-on connectors of the battery when maintenance or service work inside the UPS is necessary.
Do not place Ellipse near water or in
environments of excessive humidity.
Do not allow liquids or any foreign objects to
get inside Ellipse.
Do not block air vents in front, in the back or
on the sides of Ellipse.
Do not plug household appliances such as
hair dryers to Ellipse receptacles.
Do not place Ellipse under direct sunlight or
close to heat-emitting sources.
The AC power receptacle shall be near the
equipment and easily accessible. To isolate Ellipse from AC input, remove the input power cord from the AC power receptacle.
If Ellipse is to be stored, it is recommended
to recharge the batteries (by connecting AC power source to Ellipse, switch "ON" or OFF"), once every 6 months for 8 hours to avoid a full battery discharge.
Ellipse contains batteries that should be
disposed of or recycled in accordance with local laws.
Prior to installation, store Ellipse in a dry
location.
Maximum ambient temperature f or operation
is between 32°F (0°C) and +96°F (+35°C).
Storage temperatures must be between
32°F (0°C) and +122°F (+50°C).
Servicing of batteries should be performed
or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
When replacing the batteries, use MGE P/N
3088201000 batteries (12V-5Ah lead acid), use of any other battery may present a risk of fire or explosion.
~: Alternating current supply symbol.
CAUTION: Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or willfully damage the battery or batteries, since the released electrolyte is harmful to the skin and eyes.It may be to xic. A battery can present a risk of high shor t circuit current.
The following precautions should be observed when working with batteries for disposal or replacement:
• Switch off the UPS (on/off switch) and disconnect it from utility power;
• Remove watches, rings or other metal objects,
• Use tools with insulated handles.
Federal Communication Commission (FCC) Statement
Note: This equipment has been tested and found to
comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in a residential environment.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.
Copyright © 1999 MGE UPS Systems.
All rights reserved.
Printed in U.S.A.