MGE UPS Systems 1500 Rack, 1100 Rack, PULSAR 1500, 800 Rack, 500 Rack, 1100 User Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
www.mgeups.com
MGE UPSSYSTEMS
Pulsar Evolution
1500 /1500 Rack
1100 /1100 Rack
800/800 Rack
500 Rack
Installation and user
manual
English
Français
Deutsch
Italiano
Español
Nederlands
W
O
N
U
O
Y
P
O
T
S
L
L
I
W
G
N
I
H
T
O
N
3400711700/AB
www.mgeups.com
MGE UPSSYSTEMS
Pulsar Evolution
1500 /1500 Rack
1100 /1100 Rack
800/800 Rack
500 Rack
Installation and user
manual
W
O
N
U
O
Y
P
O
T
S
L
L
I
W
G
N
I
H
T
O
N
34007117EN/AB - Page 1
Page 2 - 34007117EN/AB
Introduction
Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
The Pulsar Evolution range has been designed with the utmost care. We recommend that you take the time to read this
manual to take full advantage of the many features of your UPS.
MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made PulsarEvolution a reference in environmental protection include:
◗ the eco-design approach used in product development,
◗ recycling of Pulsar Evolution at the end of its service life.
To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar Evolution range,
we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative.
Important: before installing and using the UPS, always read the safety instructions (document n° 3400722200).
34007117EN/AB - Page 3
Foreword
Using this document
Information may be found in two ways, using:
◗ the contents;
◗ the index.
Pictograms
Important instructions that must always be followed.
Information, advice, help.
Visual indication.
Action.
Audio indication.
Page 4 - 34007117EN/AB
In the illustrations on the following pages, the symbols below are used:
Outlets for direct connection of
protected equipment.
6
Programmable outlets (1 and 2).
7
Input circuit-breaker.
Socket for connection to AC-power
8
source.
Page 8 - 34007117EN/AB
Pulsar Evolution 1500 Rack
123845
7
1
2
6
1.3 Control panel
10
Iluminated ON/OFF button for the outlets.
11
Operation on battery power.
1. Presentation
12
UPS fault.
Battery fault.
Overload.
13
Group 1 programmable outlets supplied with power.
1
2
%
%
14
Group 2 programmable outlets supplied with power.
15
16
Booster or fader mode.
17
Bargraph indicating percent load at output.
18
Bargraph indicating the battery charge level.
76 to 100%.
51 to 75%.
26 to 50%.
0 to 25%.
34007117EN/AB - Page 9
2. Installation
2.1 Unpacking and parts check
Tower models
30
23
P U L S A R
Evolution
1 1 0 0
Two cords for connection of the protected equipment.
20
RS232 communications cable.
21
22
USB communications cable.
23
CD-ROM with the Solution-Pac and UPS Driver software.
24
Product documentation.
21
2220
24
Page 10 - 34007117EN/AB
Rack models
2. Installation
212220
2325
20
Two cords for connection of the protected equipment.
21
RS232 communications cable.
22
USB communications cable.
23
CD-ROM with the Solution-Pac and UPS Driver software.
24
Product documentation.
25
Telescopic rails for mounting in 19" bay with mounting hardware.
26
Securing system for equipment power cords.
24
P U L S A R
Evolution
1500 Rack
26
34007117EN/AB - Page 11
2. Installation
2.2 Installation
Tower models
P U L S A R
Evolution
1 1 0 0
P U L S A R
Evolution
1 1 0 0
Page 12 - 34007117EN/AB
800/1100/1500 Rack models
Follow steps 1 to 6 for rack mounting of the UPS on the rails.
2. Installation
2
1
6
2
2
4
2
P U L S A R
Evolution
1500 Rack
3
5
6
5
3
The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS.
34007117EN/AB - Page 13
2. Installation
500 Rack model
2
1
P U L S A R
Evolution
1500 Rack
3
1
3
Page 14 - 34007117EN/AB
P U L S A R
Evolution
1500 Rack
P U L S A R
Evolution
1500 Rack
2.3 Connecting the protected equipment
A PulsarEvolution 1500 tower UPS has been used below to illustrate the instructions. The principle is the same for all the
other tower and rack models.
Check that the indications on the rating plate on the back of the UPS correspond to your AC-power system and to
the actual electrical consumption of all the equipment to be connected to the UPS.
2
1
2. Installation
1 - Remove the power cord supplying the
equipment to be protected.
8
2 - Connect the power cord
from the equipment to the AC-power socket
␣ ␣ 8 , and then to the AC-power wall outlet.
3 - Connect the protected equipment to the
UPS using the two cords 20 .
Connect priority loads to the two standard
outlets ␣ 5 and any non-priority loads to the
two programmable outlets ␣ ␣ 6 (1 and 2).
If the UPS is connected to a
computer running MGE
communications software, it is
possible to program the
interruption of power to the
programmable outlets 6 during
operation on battery power, thus
6
5
4 - Lock the connections using the securing
20
system 26 (for rack models only).
reserving backup power for the
priority loads.
(1)
just removed
As soon as the UPS is energised, the battery begins charging. Eight hours are required to charge to the full rated
backup time.
(1) Make sure the cord has the following
characteristics: 250 V, 10 A, cross-sectional area
2
, type HO5.
1␣ mm
34007117EN/AB - Page 15
2. Installation
A PulsarEvolution 1500 tower UPS has been used below to illustrate the instructions. The principle is the same for all the
other tower and rack models.
2.4 Connection to the RS232 or USB communications port (optional)
21
1 - Connect the RS232 21 or USB 22
communications cable to the serial port or
RS232
2
the USB port on the computer.
22
1
2 - Connect the other end of the
communications cable 21 or 22 to the
RS232 2 or USB 1 communications
port on the UPS.
The UPS can now communicate with all
MGE UPS SYSTEMS supervision, set-up or
safety software.
The RS232 and USB
communications ports cannot
operate simultaneously.
2.5 Connection to the data-line protection port (optional)
The data-line protection function on the UPS
eliminates overvoltages flowing on the
computer-network lines.
Simply connect the line to be protected to
the UPS using the data-line protection
connectors (IN and OUT) as indicated
opposite (RJ45 cables not supplied).
Page 16 - 34007117EN/AB
RS232
INOUT
DATA LINE
PROTECTION
2.6 Installation of the communications-card option
2. Installation
4
Restricted-access slot for
the communications card
RS232
DATA LINE PROTECTION
IN
It is not necessary to shut down the UPS to install the communications card.
This operation must be carried out by qualified personnel.
OUT
1 - Remove the slot cover 4 secured by
two screws.
2 - Insert the card in the slot.
3 - Secure the cover with the two screws.
34007117EN/AB - Page 17
3. Operation
3.1 Start-up
Press the ON / OFF button 10 .
The buzzer beeps and all the LEDs come ON.
The buzzer beeps twice during the self-test, then button 10 remains
10
ON, indicating that the outlets are supplied with power.
- AC power is present: Only button 10 is ON. The protected
11
equipment is supplied by the AC-power source.
12
1
2
%
%
If button 10 or LED 11 are not ON or if LED 12 is ON, there is a fault (see section 4.1).
Note: The battery is charged as soon as the UPS is connected to the AC-power source, even if button 10 is in the OFF
position.
3.2 Shift to booster or fader mode
(during voltage variations in the AC-input power)
1
2
16
%
%
- AC power is absent: Button 10 and LED 11 are ON. The protected
equipment is supplied by the UPS, operating on battery power.
All the connected equipment is supplied with power.
The booster and fader functions maintain the output voltage supplied by
the UPS within close tolerances around the rated value even if
significant voltage variations occur in the AC-input power. This avoids
calling on battery power.
The values defining the voltage range may be set using the UPS Driver
software.
During operation in booster or fader mode, LED 16 is ON, signalling a
significant voltage variation in the AC-input power.
Page 18 - 34007117EN/AB
3. Operation
3.3 Operation on battery power (following failure of AC-input power)
Transfer to battery power
The AC-input power is out of tolerances, LED 11 goes ON.
During operation on battery power, the buzzer beeps every ten seconds.
The equipment connected to the UPS is supplied by the battery.
11
1
2
%
%
Threshold for the low-battery warning
When the threshold is reached, the buzzer beeps every three seconds.
The low-battery warning threshold can be set by the user, with the “UPS
Driver” software.
There is very little remaining battery backup time. Close all
11
applications because UPS automatic shutdown is imminent.
1
2
When the battery reaches the end of its backup time, the UPS shuts
down and all the LEDs go OFF.
%
%
The equipment is no longer supplied with power.
The UPS automatically restarts when power returns.
If the UPS does not restart, check that the “automatic restart when power returns” function has not been disabled (see
section 3.4 Personalisation).
34007117EN/AB - Page 19
3. Operation
3.4 Personalisation (optional)
Function
Personalisation parameters can be set and modified using the UPS Driver software installed on a computer that is
connected to the UPS (see section 2.4 Connection to the RS232 communications port).
Check that the RS232 21 communications cable is connected.
UPS Driver installation:
1 - Insert the Solution-Pac CD-ROM containing the UPS Driver software in the drive of a PC running Windows.
2 - Open the Windows File manager or Explorer and select the CD-ROM drive.
3 - Double-click "\Emb\Evolutio\Config\upsdriv.exe".
Once UPS Driver has been installed, UPS parameters can be modified in a window containing a number of tabs, each
presenting a set of parameters :
ON / OFF conditions tab
Battery tab
Page 20 - 34007117EN/AB
Configurable function
Automatic restart
Cold start
Forced reboot
Energy saving
UPS ON / OFF via software
Configurable function
Interval between automatic battery tests
Low-battery warning threshold
Protection against deep discharges
Default setting
Enabled
Enabled
Enabled
Disabled
Enabled
Default setting
Once a week
20% of the remaining battery
backup time
Enabled
Options
Disabled
Disabled
Disabled
Enabled
Disabled
Options
Every day
Once a month
No test
10 to 40% of the remaining battery
backup time
Disabled
Voltage-thresholds tab
3. Operation
Sensitivity tab
Configurable function
Output voltage on battery power
Upper threshold for transfer to battery power
Fader-mode cut-in threshold
Booster-mode cut-in threshold
Lower threshold for transfer to battery power
Maximum input-voltage range
(1) Lower threshold for transfer to battery power = 150 V
Configurable function
UPS sensitivity level
For more informations about these settings, refer to the Help function of the "UPS Driver" software.
Default setting
230 V
294 V
265 V
184 V
160 V
Disabled
Default setting
Normal
200 V - 220 V - 240 V
Options
271 to 294 V
244 to 265 V
184 to 207 V
160 to 180 V
Enabled
High or low
(1)
Options
34007117EN/AB - Page 21
4. Maintenance
4.1 Trouble-shooting
Troubleshooting not requiring MGE UPS SYSTEMS after-sales support (all versions)
Indication
LED 13 flashes and the
buzzer beeps once.
LED 12 flashes.
UPS overload. The power drawn by the connected
equipment exceeds UPS capacity.
A battery fault was detected during the automatic
battery test.
Signification
Troubleshooting requiring MGE UPS SYSTEMS after-sales support
Indication
LED 12 goes ON and
the buzzer sounds
continuously.
UPS electronics have detected a UPS fault.
◗ The connected equipment is no longer supplied.
The equipment connected to the UPS is no
longer protected.
Signification
Correction
Check the power drawn by the
equipment and disconnect any nonpriority devices.
Replace the battery module (see
section 4.2).
Correction
Call the after-sales support
department.
Page 22 - 34007117EN/AB
4.2 Replacement of the battery module
Safety rules
Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions
must be taken for all handling:
◗ remove all watches, rings, bracelets and any other metal objects;
◗ use tools with insulated handles.
Tower models
Removal of the battery module
This operation may be carried out with the UPS supplying power to the load.
C
P U L S A R
Evolution
1 5 0 0
4. Maintenance
A - Unclip the small plate with the MGE
logo on the front panel of the UPS.
B - Remove the two screws.
C - Remove the left-hand side of the front
panel by pulling it slightly up and then
forward.
B
A
D - Disconnect the battery module by
pulling apart the connectors (never pull on
the cables).
D
34007117EN/AB - Page 23
4. Maintenance
Installation of the new battery module
Carry out the above operation in reverse order.
◗ Caution: risk of electric arc when connecting the battery.
◗ To maintain an identical level of performance and safety, use a battery module identical to that previously
mounted in the UPS.
◗ Press the two parts of the battery connector tightly together to ensure proper connection.
E - Remove the battery module by pulling
on the plastic tab and proceed with
replacement.
E
Page 24 - 34007117EN/AB
Rack models
Removal of the battery module
This operation may be carried out with the UPS supplying power to the load.
PULSAR
Evolution
1 5 0 0
4. Maintenance
A - Unclip the small plate with the MGE
logo on the front panel of the UPS.
B - Remove the two screws.
C - Remove the left-hand side of the front
panel by pulling it forward.
B
C
A
D - Disconnect the battery module by
pulling apart the connectors (never pull on
the cables).
D
34007117EN/AB - Page 25
4. Maintenance
E - Remove the cover.
E
F - Remove the battery module by pulling
on the plastic tab and proceed with
replacement.
Page 26 - 34007117EN/AB
F
Installation of the new battery module
Carry out the above operation in reverse order.
◗ Caution: risk of electric arc when connecting the battery.
◗ To maintain an identical level of performance and safety, use a battery module identical to that previously
mounted in the UPS.
◗ Press the two parts of the battery connector tightly together to ensure proper connection.
5. Environment
This product has been designed to respect the environment:
It does not contain CFCs or HCFCs.
UPS recycling at the end of service life:
MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all
UPS products recovered at the end of their service life (contact your MGE branch office).
Packing:
UPS packing materials must be recycled in compliance with all applicable regulations.
Warning:
This product contains lead-acid batteries. Lead is a dangerous substance for the environment if it is not properly recycled
by specialised companies.
Web site: www.mgeups.com
34007117EN/AB - Page 27
6. Appendices
6.1 Technical data
Simplified diagram
Input
Booster / fader transformerFilter
Output
Inverter
Charger
Battery
Page 28 - 34007117EN/AB
Technical characteristics
6. Appendices
Pulsar Evolution500
Output rating
500 VA / 350 W
800 / 800 rack
800 VA / 560 W
AC-input power
◗ Voltage
◗ Frequency
47 Hz to 70 Hz (50 Hz system) or 56.5 Hz to 70 Hz
Single-phase, 160 V to 294 V
Output power (operation
on battery power)
◗ Voltage
◗ Frequency
Single-phase, 230 V
50/60 Hz +/- 0.1 Hz
Battery (sealed lead-acid,
maintenance free)
◗ Tower models
◗ Rack models
2 x 6 V - 9 Ah,
2 x 12 V - 7.2 Ah,
4 x 6 V - 7.2 Ah
Environment
◗ Noise level (operation on
<40 dBA
AC-input power)
◗ Operating temperature
◗ Relative humidity
(without condensation)
0 to 35° C
20 to 90%
(1) The upper and lower thresholds may be set using the UPS Driver software.
(2) Or 40 Hz in low-sensitivity mode (may be set using the UPS Driver software).
(3) Adjustable from 200 to 240 V using the UPS Driver software.
1100 / 1100 rack
1100 VA / 700 W
(1)
, 230V nominal.
(3)
(+ 6% / - 10%)
2 x 12 V - 9 Ah,
4 x 6 V - 9 Ah
1500 / 1500 rack
1500 VA / 1000 W
(2)
(60 Hz system)
3 x 12 V - 9 Ah,
6 x 6 V - 9 Ah
<40 dBA
0 to 40° C
20 to 90%
34007117EN/AB - Page 29
Loading...
+ 166 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.